Zhou X, Sakaie KE, Debbins JP, Kirsch JE, Tatsuoka C, Fox RJ, Lowe MJ. Quantitative quality assurance in a multicenter HARDI clinical trial at 3T. Magn Reson Imaging 2016; 35:81-90. [PMID: 27587227 DOI: 10.1016/j.mri.2016.08.022] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Revised: 08/23/2016] [Accepted: 08/24/2016] [Indexed: 12/28/2022]
Abstract
A phantom-based quality assurance (QA) protocol was developed for a multicenter clinical trial including high angular resolution diffusion imaging (HARDI). A total of 27 3T MR scanners from 2 major manufacturers, GE (Discovery and Signa scanners) and Siemens (Trio and Skyra scanners), were included in this trial. With this protocol, agar phantoms doped to mimic relaxation properties of brain tissue are scanned on a monthly basis, and quantitative procedures are used to detect spiking and to evaluate eddy current and Nyquist ghosting artifacts. In this study, simulations were used to determine alarm thresholds for minimal acceptable signal-to-noise ratio (SNR). Our results showed that spiking artifact was the most frequently observed type of artifact. Overall, Trio scanners exhibited less eddy current distortion than GE scanners, which in turn showed less distortion than Skyra scanners. This difference was mainly caused by the different sequences used on these scanners. The SNR for phantom scans was closely correlated with the SNR from volunteers. Nearly all of the phantom measurements with artifact-free images were above the alarm threshold, suggesting that the scanners are stable longitudinally. Software upgrades and hardware replacement sometimes affected SNR substantially but sometimes did not. In light of these results, it is important to monitor longitudinal SNR with phantom QA to help interpret potential effects on in vivo measurements. Our phantom QA procedure for HARDI scans was successful in tracking scanner performance and detecting unwanted artifacts.
Collapse
Affiliation(s)
- Xiaopeng Zhou
- Imaging Institute, Cleveland Clinic, Cleveland, OH, 44195, USA
| | - Ken E Sakaie
- Imaging Institute, Cleveland Clinic, Cleveland, OH, 44195, USA
| | - Josef P Debbins
- Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, 85013,USA
| | | | - Curtis Tatsuoka
- Department of Neurology, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Robert J Fox
- Neurological Institute, Cleveland Clinic, Cleveland, OH, 44195, USA
| | - Mark J Lowe
- Imaging Institute, Cleveland Clinic, Cleveland, OH, 44195, USA.
| |
Collapse
|
152
|
Baykara E, Gesierich B, Adam R, Tuladhar AM, Biesbroek JM, Koek HL, Ropele S, Jouvent E, Chabriat H, Ertl-Wagner B, Ewers M, Schmidt R, de Leeuw FE, Biessels GJ, Dichgans M, Duering M. A Novel Imaging Marker for Small Vessel Disease Based on Skeletonization of White Matter Tracts and Diffusion Histograms. Ann Neurol 2016; 80:581-92. [PMID: 27518166 DOI: 10.1002/ana.24758] [Citation(s) in RCA: 236] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 08/08/2016] [Accepted: 08/09/2016] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To establish a fully automated, robust imaging marker for cerebral small vessel disease (SVD) and related cognitive impairment that is easy to implement, reflects disease burden, and is strongly associated with processing speed, the predominantly affected cognitive domain in SVD. METHODS We developed a novel magnetic resonance imaging marker based on diffusion tensor imaging, skeletonization of white matter tracts, and histogram analysis. The marker (peak width of skeletonized mean diffusivity [PSMD]) was assessed along with conventional SVD imaging markers. We first evaluated associations with processing speed in patients with genetically defined SVD (n = 113). Next, we validated our findings in independent samples of inherited SVD (n = 57), sporadic SVD (n = 444), and memory clinic patients with SVD (n = 105). The new marker was further applied to healthy controls (n = 241) and to patients with Alzheimer's disease (n = 153). We further conducted a longitudinal analysis and interscanner reproducibility study. RESULTS PSMD was associated with processing speed in all study samples with SVD (p-values between 2.8 × 10(-3) and 1.8 × 10(-10) ). PSMD explained most of the variance in processing speed (R(2) ranging from 8.8% to 46%) and consistently outperformed conventional imaging markers (white matter hyperintensity volume, lacune volume, and brain volume) in multiple regression analyses. Increases in PSMD were linked to vascular but not to neurodegenerative disease. In longitudinal analysis, PSMD captured SVD progression better than other imaging markers. INTERPRETATION PSMD is a new, fully automated, and robust imaging marker for SVD. PSMD can easily be applied to large samples and may be of great utility for both research studies and clinical use. Ann Neurol 2016;80:581-592.
Collapse
Affiliation(s)
- Ebru Baykara
- Institute for Stroke and Dementia Research, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany
| | - Benno Gesierich
- Institute for Stroke and Dementia Research, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany
| | - Ruth Adam
- Institute for Stroke and Dementia Research, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany
| | - Anil Man Tuladhar
- Radboud University Medical Center, Donders Institute for Brain, Cognition, and Behavior, Department of Neurology, Nijmegen, the Netherlands
| | - J Matthijs Biesbroek
- Department of Neurology, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Huiberdina L Koek
- Department of Geriatrics, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Stefan Ropele
- Department of Neurology, Medical University of Graz, Graz, Austria
| | - Eric Jouvent
- Université Paris Diderot, Sorbonne Paris Cité, UMR-S 1161 National Institute for Health and Medical Research (INSERM), Paris, France.,Departement Hospitalo-Universitaire NeuroVasc Sorbonne Paris Cité, Paris, France.,Department of Neurology, Lariboisière Hospital, Assistance Publique - Hôpitaux de Paris, Paris, France
| | | | - Hugues Chabriat
- Université Paris Diderot, Sorbonne Paris Cité, UMR-S 1161 National Institute for Health and Medical Research (INSERM), Paris, France.,Departement Hospitalo-Universitaire NeuroVasc Sorbonne Paris Cité, Paris, France.,Department of Neurology, Lariboisière Hospital, Assistance Publique - Hôpitaux de Paris, Paris, France
| | - Birgit Ertl-Wagner
- Institute of Clinical Radiology, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany
| | - Michael Ewers
- Institute for Stroke and Dementia Research, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany
| | - Reinhold Schmidt
- Department of Neurology, Medical University of Graz, Graz, Austria
| | - Frank-Erik de Leeuw
- Radboud University Medical Center, Donders Institute for Brain, Cognition, and Behavior, Department of Neurology, Nijmegen, the Netherlands
| | - Geert Jan Biessels
- Department of Neurology, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Martin Dichgans
- Institute for Stroke and Dementia Research, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany.,Munich Cluster for Systems Neurology (SyNergy), Munich, Germany.,German Center for Neurodegenerative Diseases (DZNE), Munich, Germany
| | - Marco Duering
- Institute for Stroke and Dementia Research, Klinikum der Universität München, Ludwig-Maximilians-University LMU, Munich, Germany.
| |
Collapse
|
153
|
Lilja Y, Gustafsson O, Ljungberg M, Nilsson D, Starck G. Impact of region-of-interest method on quantitative analysis of DTI data in the optic tracts. BMC Med Imaging 2016; 16:42. [PMID: 27400959 PMCID: PMC4940685 DOI: 10.1186/s12880-016-0145-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 06/14/2016] [Indexed: 11/10/2022] Open
Abstract
Background To extract DTI parameters from a specific structure, a region of interest (ROI) must be defined. ROI selection in small structures is challenging; the final measurement results could be affected due to the significant impact of small geometrical errors. In this study the optic tracts were analyzed with the aim to assess differences in DTI parameters due to ROI method and to identify the most reliable method. Methods Images of 20 healthy subjects were acquired. Fractional anisotropy (FA) was extracted from the optic tracts by four different ROI methods. Manual tracing was performed in 1) the b0 image and 2) a T1-weighted image registered to the FA image. Semi-automatic segmentation was performed based on 3) tractography and 4) the FA-skeleton algorithm in the tract-based spatial statistics (TBSS) framework. Results were analyzed with regard to ROI method as well as to inter-scan, intra-rater and inter-rater reliability. Results The resulting FA values divided the ROI methods into two groups that differed significantly: 1) the FA-skeleton and the b0 methods showed higher FA values compared to 2) the tractography and the T1-weighted methods. The intra- and inter-rater variabilities were similar for all methods, except for the tractography method where the inter-rater variability was higher. The FA-skeleton method had a better reproducibility than the other methods. Conclusion Choice of ROI method was found to be highly influential on FA values when the optic tracts were analyzed. The FA-skeleton method performed the best, yielding low variability and high repeatability.
Collapse
Affiliation(s)
- Ylva Lilja
- Department of Clinical Neuroscience and Rehabilitation, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. .,Ear, Nose and Throat Clinic, Sahlgrenska University Hospital, Gröna stråket 5, 413 45, Göteborg, Sweden.
| | - Oscar Gustafsson
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maria Ljungberg
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Daniel Nilsson
- Department of Clinical Neuroscience and Rehabilitation, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Neurosurgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Göran Starck
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
154
|
Intravoxel Incoherent Motion Metrics as Potential Biomarkers for Survival in Glioblastoma. PLoS One 2016; 11:e0158887. [PMID: 27387822 PMCID: PMC4936699 DOI: 10.1371/journal.pone.0158887] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Accepted: 06/23/2016] [Indexed: 01/03/2023] Open
Abstract
Objective Intravoxel incoherent motion (IVIM) is an MRI technique with potential applications in measuring brain tumor perfusion, but its clinical impact remains to be determined. We assessed the usefulness of IVIM-metrics in predicting survival in newly diagnosed glioblastoma. Methods Fifteen patients with glioblastoma underwent MRI including spin-echo echo-planar DWI using 13 b-values ranging from 0 to 1000 s/mm2. Parametric maps for diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) were generated for contrast-enhancing regions (CER) and non-enhancing regions (NCER). Regions of interest were manually drawn in regions of maximum f and on the corresponding dynamic susceptibility contrast images. Prognostic factors were evaluated by Kaplan-Meier survival and Cox proportional hazards analyses. Results We found that fCER and D*CER correlated with rCBFCER. The best cutoffs for 6-month survival were fCER>9.86% and D*CER>21.712 x10−3mm2/s (100% sensitivity, 71.4% specificity, 100% and 80% positive predictive values, and 80% and 100% negative predictive values; AUC:0.893 and 0.857, respectively). Treatment yielded the highest hazard ratio (5.484; 95% CI: 1.162–25.88; AUC: 0.723; P = 0.031); fCER combined with treatment predicted survival with 100% accuracy. Conclusions The IVIM-metrics fCER and D*CER are promising biomarkers of 6-month survival in newly diagnosed glioblastoma.
Collapse
|
155
|
Samson RS, Lévy S, Schneider T, Smith AK, Smith SA, Cohen-Adad J, Gandini Wheeler-Kingshott CAM. ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies. PLoS One 2016; 11:e0155557. [PMID: 27171194 PMCID: PMC4865165 DOI: 10.1371/journal.pone.0155557] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Accepted: 04/29/2016] [Indexed: 12/02/2022] Open
Abstract
The purpose of this study was to develop and evaluate two spinal cord (SC) diffusion tensor imaging (DTI) protocols, implemented at multiple sites (using scanners from two different manufacturers), one available on any clinical scanner, and one using more advanced options currently available in the research setting, and to use an automated processing method for unbiased quantification. DTI parameters are sensitive to changes in the diseased SC. However, imaging the cord can be technically challenging due to various factors including its small size, patient-related and physiological motion, and field inhomogeneities. Rapid acquisition sequences such as Echo Planar Imaging (EPI) are desirable but may suffer from image distortions. We present a multi-centre comparison of two acquisition protocols implemented on scanners from two different vendors (Siemens and Philips), one using a reduced field-of-view (rFOV) EPI sequence, and one only using options available on standard clinical scanners such as outer volume suppression (OVS). Automatic analysis was performed with the Spinal Cord Toolbox for unbiased and reproducible quantification of DTI metrics in the white matter. Images acquired using the rFOV sequence appear less distorted than those acquired using OVS alone. SC DTI parameter values obtained using both sequences at all sites were consistent with previous measurements made at 3T. For the same scanner manufacturer, DTI parameter inter-site SDs were smaller for the rFOV sequence compared to the OVS sequence. The higher inter-site reproducibility (for the same manufacturer and acquisition details, i.e. ZOOM data acquired at the two Philips sites) of rFOV compared to the OVS sequence supports the idea that making research options such as rFOV more widely available would improve accuracy of measurements obtained in multi-centre clinical trials. Future multi-centre studies should also aim to match the rFOV technique and signal-to-noise ratios in all sequences from different manufacturers/sites in order to avoid any bias in measured DTI parameters and ensure similar sensitivity to pathological changes.
Collapse
Affiliation(s)
- Rebecca S. Samson
- NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, London, United Kingdom
- * E-mail:
| | - Simon Lévy
- Institute of Biomedical Engineering, Ecole Polytechnique de Montreal, Montreal, QC, Canada
- Functional Neuroimaging Unit, University of Montreal, Montreal, QC, Canada
| | - Torben Schneider
- NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, London, United Kingdom
- Philips Healthcare, Guilford, Surrey, United Kingdom
| | - Alex K. Smith
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, Tennessee, United States of America
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, United States of America
| | - Seth A. Smith
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, Tennessee, United States of America
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, United States of America
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee, United States of America
| | - Julien Cohen-Adad
- Institute of Biomedical Engineering, Ecole Polytechnique de Montreal, Montreal, QC, Canada
- Functional Neuroimaging Unit, University of Montreal, Montreal, QC, Canada
| | - Claudia A. M. Gandini Wheeler-Kingshott
- NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, London, United Kingdom
- Brain MRI 3T Center, C. Mondino National Neurological Institute, Pavia, Italy
- Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy
| |
Collapse
|
156
|
Zolal A, Juratli TA, Linn J, Podlesek D, Sitoci Ficici KH, Kitzler HH, Schackert G, Sobottka SB, Rieger B, Krex D. Enhancing tumor apparent diffusion coefficient histogram skewness stratifies the postoperative survival in recurrent glioblastoma multiforme patients undergoing salvage surgery. J Neurooncol 2016; 127:551-7. [DOI: 10.1007/s11060-016-2063-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2015] [Accepted: 01/22/2016] [Indexed: 11/30/2022]
|
157
|
Jafar MM, Parsai A, Miquel ME. Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility. World J Radiol 2016; 8:21-49. [PMID: 26834942 PMCID: PMC4731347 DOI: 10.4329/wjr.v8.i1.21] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 11/10/2015] [Accepted: 12/07/2015] [Indexed: 02/06/2023] Open
Abstract
There is considerable disparity in the published apparent diffusion coefficient (ADC) values across different anatomies. Institutions are increasingly assessing repeatability and reproducibility of the derived ADC to determine its variation, which could potentially be used as an indicator in determining tumour aggressiveness or assessing tumour response. In this manuscript, a review of selected articles published to date in healthy extra-cranial body diffusion-weighted magnetic resonance imaging is presented, detailing reported ADC values and discussing their variation across different studies. In total 115 studies were selected including 28 for liver parenchyma, 15 for kidney (renal parenchyma), 14 for spleen, 13 for pancreatic body, 6 for gallbladder, 13 for prostate, 13 for uterus (endometrium, myometrium, cervix) and 13 for fibroglandular breast tissue. Median ADC values in selected studies were found to be 1.28 × 10(-3) mm(2)/s in liver, 1.94 × 10(-3) mm(2)/s in kidney, 1.60 × 10(-3) mm(2)/s in pancreatic body, 0.85 × 10(-3) mm(2)/s in spleen, 2.73 × 10(-3) mm(2)/s in gallbladder, 1.64 × 10(-3) mm(2)/s and 1.31 × 10(-3) mm(2)/s in prostate peripheral zone and central gland respectively (combined median value of 1.54×10(-3) mm(2)/s), 1.44 × 10(-3) mm(2)/s in endometrium, 1.53 × 10(-3) mm(2)/s in myometrium, 1.71 × 10(-3) mm(2)/s in cervix and 1.92 × 10(-3) mm(2)/s in breast. In addition, six phantom studies and thirteen in vivo studies were summarized to compare repeatability and reproducibility of the measured ADC. All selected phantom studies demonstrated lower intra-scanner and inter-scanner variation compared to in vivo studies. Based on the findings of this manuscript, it is recommended that protocols need to be optimised for the body part studied and that system-induced variability must be established using a standardized phantom in any clinical study. Reproducibility of the measured ADC must also be assessed in a volunteer population, as variations are far more significant in vivo compared with phantom studies.
Collapse
|
158
|
Enlargement of choroid plexus in complex regional pain syndrome. Sci Rep 2015; 5:14329. [PMID: 26388497 PMCID: PMC4585686 DOI: 10.1038/srep14329] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Accepted: 08/20/2015] [Indexed: 01/05/2023] Open
Abstract
The choroid plexus, located in brain ventricles, has received surprisingly little attention in clinical neuroscience. In morphometric brain analysis, we serendipitously found a 21% increase in choroid plexus volume in 12 patients suffering from complex regional pain syndrome (CRPS) compared with age- and gender-matched healthy subjects. No enlargement was observed in a group of 8 patients suffering from chronic pain of other etiologies. Our findings suggest involvement of the choroid plexus in the pathogenesis of CRPS. Since the choroid plexus can mediate interaction between peripheral and brain inflammation, our findings pinpoint the choroid plexus as an important target for future research of central pain mechanisms.
Collapse
|