151
|
[Evaluation of the left ventricle with three-dimensional echocardiography: comparison with cardiac magnetic resonance]. RADIOLOGIA 2010; 52:534-40. [PMID: 20846703 DOI: 10.1016/j.rx.2010.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2009] [Revised: 05/28/2010] [Accepted: 06/04/2010] [Indexed: 11/22/2022]
Abstract
OBJECTIVE Three-dimensional echocardiography (3DE) is becoming increasingly common in clinical environments. However, the quality of the images depends on the acoustic window, and it can be difficult to identify the endocardial borders. The objective of this study was to evaluate the performance of 3DE in determining the volumes and left ventricular ejection fraction in unselected patients against the gold standard, cardiac magnetic resonance (CMR). MATERIAL AND METHODS In 47 unselected patients who underwent CMR, we performed 3DE using a real-time acquisition technique and semiautomatic border detection. RESULTS We excluded 4 patients (8.5%) because they had an extremely deficient acoustic window. In the remaining 43 patients, including those with a suboptimal acoustic window, we obtained the following correlations between 3DE and CMR: end-diastolic volume, 0.71; end-systolic volume, 0.77; ejection fraction, 0.74. Although the end-diastolic volume was systematically underestimated, no significant differences were observed in the ejection fraction. When the 11 patients with suboptimal acoustic windows were excluded, we observed a systematic underestimation of the end-diastolic and end-systolic volumes, which paradoxically gave rise to improved correlation coefficients (0.79, 0.92, and 0.84, respectively) and a more accurate ejection fraction. CONCLUSIONS Compared to CMR, 3DE systematically underestimates the ventricular volumes but enables adequate determination of the left ventricular ejection fraction regardless of the quality of the acoustic window.
Collapse
|
152
|
Kataoka A, Funabashi N, Takahashi A, Yajima R, Takahashi M, Uehara M, Takaoka H, Saito M, Yamaguchi C, Lee K, Nomura F, Komuro I. Quantitative evaluation of left atrial volumes and ejection fraction by 320-slice computed-tomography in comparison with three- and two-dimensional echocardiography: a single-center retrospective-study in 22 subjects. Int J Cardiol 2010; 153:47-54. [PMID: 20826014 DOI: 10.1016/j.ijcard.2010.08.036] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2010] [Revised: 06/24/2010] [Accepted: 08/07/2010] [Indexed: 12/25/2022]
Abstract
PURPOSE To evaluate efficacy and reproducibility of 320-slice computed tomography (CT) for measuring left atrial (LA) maximum (LAVmax) and minimum volume (LAVmin) during the cardiac cycle, we compared CT with three- and two-dimensional (3D and 2D) transthoracic echocardiogram (TTE). MATERIALS AND METHODS LAVmax and LAVmin (ml), and LA ejection fraction (LAEF) (%) were assessed in 22 consecutive subjects (15 males, 59.5 ± 15.1 years) using retrospective electrocardiogram gated 320-slice CT (Aquilion One, Toshiba Medical) and 3D-TTE (IE-33, Phillips). LAVmax and LAVmin were selected from the time volume curve. LAEF was calculated as (LAVmax-LAVmin)/LAVmax×100(%). RESULTS Mean ± standard deviation (SD) of LAVmax and LAV min were significantly larger by CT than 3D-TTE or 2D-TTE (both P<0.01). LAEF was 25.3 ± 13.1% by CT, 30.2 ± 6.8% by 3D-TTE (P=NS) and 33.9 ± 8.9% by 2D-TTE (P<0.05). The correlation coefficients (CCs) between CT and 3D-TTE in LAVmax, LAmin, and LAEF were 0.64, 0.68 and 0.57, respectively. Mean difference ± 1.96SD of LAVmax, LAVmin and LAEF by Bland and Altman analysis calculated from CT minus 3D-TTE were 48.8 ± 59.1 ml, 41.1 ± 63.2 ml, and -4.9 ± 21.1%, respectively. The CCs and mean difference ± 1.96SD between CT and 2D-TTE had similar tendencies. The CCs of interobserver variation were (for CT, 3D-TTE, 2D-TTE, respectively): 0.90, 0.95 and 0.94 (LAVmax), 0.97 and 0.97 and 0.93 (LAVmin), and 0.64, 0.77 and 0.34 (LAEF). CONCLUSIONS 320-slice CT enables direct LAV measurements and has high reproducibility and positive correlation with 3D and 2D TTE. Absolute value of LAV by CT was larger than that by 3D and 2D TTE.
Collapse
Affiliation(s)
- Akihisa Kataoka
- Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba 260-8670, Japan
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
153
|
Zheng M, Li X, Zhang P, Shentu W, Ashraf M, Imanbayev G, Streiff C, Ge S, Sahn DJ. Assessment of Interventricular Dyssynchrony by Real Time Three-Dimensional Echocardiography: An In Vitro Study in a Porcine Model. Echocardiography 2010; 27:709-15. [DOI: 10.1111/j.1540-8175.2009.01094.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
154
|
Walker J, Bhullar N, Fallah-Rad N, Lytwyn M, Golian M, Fang T, Summers AR, Singal PK, Barac I, Kirkpatrick ID, Jassal DS. Role of three-dimensional echocardiography in breast cancer: comparison with two-dimensional echocardiography, multiple-gated acquisition scans, and cardiac magnetic resonance imaging. J Clin Oncol 2010; 28:3429-36. [PMID: 20530277 DOI: 10.1200/jco.2009.26.7294] [Citation(s) in RCA: 133] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
PURPOSE In patients with breast cancer, the administration of doxorubicin and trastuzumab is associated with an increased risk of cardiotoxicity. Although multiple-gated acquisition (MUGA) scans and two-dimensional transthoracic echocardiography (TTE) are conventional methods for baseline and serial assessment of left ventricular ejection fraction (LVEF) in these patients, little is known about the use of real-time three-dimensional TTE (RT3D TTE) in this clinical setting. The aim of this study was to assess the accuracy of MUGA, 2D TTE, and RT3D TTE for determining LVEF in comparison to cardiac magnetic resonance imaging (CMR). METHODS Between 2007 and 2009 inclusive, 50 female patients with human epidermal growth factor receptor 2-positive breast cancer received adjuvant trastuzumab after doxorubicin. Serial MUGA, 2D TTE, RT3D TTE, and CMR were performed at baseline, 6, and 12 months after the initiation of trastuzumab. RESULTS A comparison of left ventricular end diastolic volume (LVEDV) demonstrated a modest correlation between 2D TTE and CMR (r = 0.64 at baseline; r = 0.69 at 12 months, respectively). A comparison of LVEDV between RT3D TTE and CMR demonstrated a stronger correlation (r = 0.87 at baseline; r = 0.95 at 12 months, respectively). Although 2D TTE demonstrated a weak correlation with CMR for LVEF assessment (r = 0.31 at baseline, r = 0.42 at 12 months, respectively), both RT3D TTE and MUGA showed a strong correlation when compared with CMR (r = 0.91 at baseline; r = 0.90 at 12 months, respectively). CONCLUSION As compared with conventional MUGA, RT3D TTE is a feasible, accurate, and reproducible alternate imaging modality for the serial monitoring of LVEF in patients with breast cancer.
Collapse
Affiliation(s)
- Jonathan Walker
- Institute of Cardiovascular Sciences, Cardiology Division, St Boniface General Hospital, University of Manitoba, Canada
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
155
|
Three-Dimensional Transesophageal Echocardiography Is a Major Advance for Intraoperative Clinical Management of Patients Undergoing Cardiac Surgery. Anesth Analg 2010; 110:1548-73. [DOI: 10.1213/ane.0b013e3181d41be7] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
156
|
de Agustín JA, Pérez de Isla L, Núñez-Gil IJ, Vivas D, Manzano MDC, Marcos-Alberca P, Fernández-Golfín C, Corros C, Almería C, Rodrigo JL, Aubele A, Herrera D, Rodríguez E, Macaya C, Zamorano J. Assessment of myocardial deformation: Predicting medium-term left ventricular dysfunction after surgery in patients with chronic mitral regurgitation. Rev Esp Cardiol 2010; 63:544-53. [PMID: 20450848 DOI: 10.1016/s1885-5857(10)70116-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION AND OBJECTIVES The development of left ventricular dysfunction after mitral valve replacement is a common problem in patients with chronic severe mitral regurgitation. Assessment of myocardial deformation enables myocardial contractility to be accurately estimated. Our aim was to compare the value of the preoperative strain and strain rate derived by either speckle-tracking echocardiography or tissue Doppler imaging (TDI) for predicting the medium-term decrease in left ventricular ejection fraction (LVEF) following surgery. METHODS This prospective study involved 38 consecutive patients with chronic severe mitral regurgitation who were scheduled for mitral valve replacement. The longitudinal strain and strain rate in the interventricular septum were measured preoperatively using speckle-tracking echocardiography and TDI. The LVEF was determined preoperatively and postoperatively using 3-dimensional echocardiography. Echocardiographic assessments were performed in the 48 hours prior to surgery and 6 months postoperatively. RESULTS The patients' mean age was 59.9+/-11.3 years and 10 (29.4%) were male. Both speckle-tracking echocardiography and TDI were found to be predictors of a >10% decrease in LVEF at 6 months. However, the predictive value of speckle-tracking echocardiography was greater than that of TDI. The longitudinal strain at baseline in the interventricular septum as measured by speckle-tracking echocardiography was the most powerful predictor; the area under the curve was 0.85 and the optimal cut-off value was -0.11. CONCLUSIONS Speckle-tracking echocardiography can be used to predict a decrease in LVEF over the medium term after mitral valve replacement. Moreover, the predictive accuracy of speckle-tracking echocardiography was greater than that of TDI.
Collapse
|
157
|
Teixeira R, Lourenço C, António N, Jorge E, Baptista R, Saraiva F, Mendes P, Monteiro S, Gonçalves F, Monteiro P, Freitas M, Providência LA. Can we improve outcomes in patients with previous coronary artery bypass surgery admitted for acute coronary syndrome? Rev Esp Cardiol 2010; 63:554-63. [PMID: 20450849 DOI: 10.1016/s1885-5857(10)70117-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION AND OBJECTIVES Prognosis and in-hospital management of patients with acute coronary syndrome (ACS) and a history of coronary artery bypass graft (CABG) surgery are still debated. The objective of this study was to characterize ACS patients with a CABG and to compare their in-hospital and postdischarge outcomes with those of patients without a CABG. METHODS This ongoing prospective observational study included 1,495 consecutive patients admitted for ACS to a coronary care unit and followed up for a mean of 19 months. There were two groups: group A (n=73), with CABGs; and group B (n=1,223), without CABGs. RESULTS Group A patients were more often male (86.3% versus 69.1%; P=.002), and more frequently had a history of diabetes, myocardial infarction and heart failure. Group B patients more frequently had ST-elevation myocardial infarction, and had a higher median ejection fraction (53% [interquartile range, 47%-60%] vs. 50% [42%-55%]; P< .01) and peak troponin-I concentration. There was no difference in the use of invasive techniques. Regarding medication, Group B patients were more likely to receive dual antiplatelet therapy at discharge. No significant difference was observed in in-hospital mortality (9.5% versus 5.9%; P=.2) or mortality at 1 month, 6 months or 1 year (9.8% versus 9.1%; log-rank test, P=.87) and the cumulative major adverse cardiac event rate was equally low in both groups. The presence of a CABG was associated with more readmissions for unstable angina (11.3% vs. 3.1%; P< .01). CONCLUSIONS In our ACS patients, the presence of a CABG had no significant influence on short- or medium-term outcomes, such as all-cause mortality and adverse cardiac events.
Collapse
Affiliation(s)
- Rogério Teixeira
- Unidad de Cuidados Coronarios, Hospital Universitario, Coimbra, Portugal.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
158
|
de Agustín JA, de Isla LP, Núñez-Gil IJ, Vivas D, Manzano MDC, Marcos-Alberca P, Fernández-Golfín C, Corros C, Almería C, Rodrigo JL, Aubele A, Herrera D, Rodríguez E, Macaya C, Zamorano J. Estudio de la deformación miocárdica: predictor de disfunción ventricular a medio plazo tras cirugía en pacientes con insuficiencia mitral crónica. Rev Esp Cardiol 2010. [DOI: 10.1016/s0300-8932(10)70116-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
159
|
Macron L, Lim P, Bensaid A, Nahum J, Dussault C, Mitchell-Heggs L, Dubois-Randé JL, Deux JF, Gueret P. Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance. Circ Cardiovasc Imaging 2010; 3:450-5. [PMID: 20435854 DOI: 10.1161/circimaging.109.925966] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Real-time 3-dimensional echocardiography (RT3DE) is superior to 2D echocardiography in assessing left ventricular (LV) volumes and ejection fraction (EF), but its feasibility is limited by multibeat acquisition, which requires an optimal breath-hold and a regular heart rhythm. We sought to evaluate the accuracy and feasibility of single- and 2-beat RT3DE for LV volume and EF assessment. METHODS AND RESULTS Sixty-six consecutive patients referred for cardiac magnetic resonance (CMR) underwent RT3DE and CMR on the same day. Of the 50 patients (age, 59+/-18 years; 68%men; 42% coronary artery disease; LVEF=49+/-14%; limits, 14% to 76%) with an adequate RT3DE image quality, accuracy for LV volumes and EF measurements of single- and 2-beat modalities were compared with the conventional 4-beat acquisition and CMR. Correlations with CMR for LV end-diastolic volume (161+/-59 mL, r=0.93 to 0.94) and end-systolic volume (86+/-56 mL, r=0.93 to 0.96) were excellent regardless of the number of cardiac cycles used. However, because of the low temporal resolution (7+/-2 volumes per second), single-beat underestimated LVEF (bias, -5+/-8%) with greater bias than 2-beat (bias, 1+/-6%, P<0.001) and 4-beat (bias, 3+/-7%, P<0.001) modalities. Interestingly, 2-beat provided accuracy similar to 4-beat for end-diastolic volume (bias, -17+/-21 mL versus -15+/-23 mL), end-systolic volume (bias, -9+/-16 mL versus -12+/-17 mL), and LVEF (bias, 1+/-6% versus 3+/-7%) measurements, but fewer stitching artifacts were observed with 2- than 4-beat modalities (3% versus 30%). CONCLUSIONS Compared with conventional multibeat acquisitions, 2-beat modality provides similar accuracy in LV volume and EF measurements and should be preferred due to fewer stitching artifacts. In contrast, the temporal resolution of single-beat modality appears insufficient to provide an accurate estimation of LVEF.
Collapse
Affiliation(s)
- Laurent Macron
- APHP, Henri Mondor University Hospital, Cardiovascular Department, and INSERM U841, 51 Av. de Lattre de Tassigny, Creteil, France
| | | | | | | | | | | | | | | | | |
Collapse
|
160
|
Aune E, Bækkevar M, Rødevand O, Otterstad JE. Reference values for left ventricular volumes with real-time 3-dimensional echocardiography. SCAND CARDIOVASC J 2010; 44:24-30. [DOI: 10.3109/14017430903114446] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
161
|
Leung KYE, Bosch JG. Automated border detection in three-dimensional echocardiography: principles and promises. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2010; 11:97-108. [PMID: 20139440 DOI: 10.1093/ejechocard/jeq005] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Several automated border detection approaches for three-dimensional echocardiography have been developed in recent years, allowing quantification of a range of clinically important parameters. In this review, the background and principles of these approaches and the different classes of methods are described from a practical perspective, as well as the research trends to achieve a robust method.
Collapse
Affiliation(s)
- K Y Esther Leung
- Thoraxcenter Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands
| | | |
Collapse
|
162
|
Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography. ACTA ACUST UNITED AC 2010; 11:359-68. [DOI: 10.1093/ejechocard/jep217] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
163
|
Hudaverdi M, Hamilton-Craig C, Platts D, Chan J, Burstow DJ. Echocardiography for the clinician: a practical update. Intern Med J 2010; 40:476-85. [PMID: 20059600 DOI: 10.1111/j.1445-5994.2010.02167.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Echocardiography is the mainstay of cardiovascular diagnostics, and is the most performed test for the evaluation of cardiac function. Critical and costly management decisions are based on quantification of left ventricular volumes and ejection fraction. Recent advances in echocardiography, such as microsphere contrast echocardiography for left ventricular opacification and perfusion imaging, three-dimensional transthoracic and trans-oesophageal imaging, strain and tissue Doppler imaging, all contribute to improving accuracy and reproducibility of these important measurements. Such techniques are now routinely available on standard echocardiography equipment in Australian centres for daily use. Hand-carried ultrasound devices have been developed, which are portable, are affordable and offer increased availability of echocardiography to the wider community. Clinicians should be actively encouraged to adopt these technologies to improve the diagnostic quality and reproducability of echocardiography for our patients. This article provides an overview of important recent advances in echocardiographic imaging with an emphasis on their role in clinical practice today.
Collapse
Affiliation(s)
- M Hudaverdi
- Department of Echocardiography, The Prince Charles Hospital, Brisbane, Queensland 4032, Australia
| | | | | | | | | |
Collapse
|
164
|
Claver E, Leta R, Pujadas S, Hidalgo A, Carreras F, Pons-Lladó G. Evaluation of the left ventricle with three-dimensional echocardiography: Comparison with cardiac magnetic resonance. RADIOLOGIA 2010. [DOI: 10.1016/s2173-5107(10)70027-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
165
|
Abstract
Patients with chronic kidney disease are well recognized to develop a wide range of cardiac structural and functional abnormalities. These changes may be progressive and relate directly to a grossly aggravated risk of cardiovascular events and reduced survival. Although conventional methods of cardiac assessment have been shown to be useful, they are limited by insufficient sensitivity and specificity, to fully appreciate the overall degree of myocardial distress that is common in these patients. This article aims to review the use of established and emerging cardiac imaging tools and, in particular, their application in patients with chronic kidney disease.
Collapse
|
166
|
Laser KT, Bunge M, Hauffe P, Argueta JRP, Kelter-Klopping A, Barth P, Sarikouch S, Burchert W, Kececioglu D, Korperich H. Left ventricular volumetry in healthy children and adolescents: comparison of two different real-time three-dimensional matrix transducers with cardiovascular magnetic resonance. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2009; 11:138-48. [DOI: 10.1093/ejechocard/jep185] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
167
|
Yu CM, Chan JYS, Zhang Q, Yip GW, Lam YY, Chan A, Burkhoff D, Lee PW, Fung JWH. Impact of Cardiac Contractility Modulation on Left Ventricular Global and Regional Function and Remodeling. JACC Cardiovasc Imaging 2009; 2:1341-9. [DOI: 10.1016/j.jcmg.2009.07.011] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2009] [Accepted: 07/07/2009] [Indexed: 11/15/2022]
|
168
|
Fang F, Chan JYS, Yip GWK, Xie JM, Zhang Q, Fung JWH, Lam YY, Yu CM. Prevalence and determinants of left ventricular systolic dyssynchrony in patients with normal ejection fraction received right ventricular apical pacing: a real-time three-dimensional echocardiographic study. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2009; 11:109-18. [DOI: 10.1093/ejechocard/jep171] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
169
|
Jenkins C, Marwick TH. Baseline and follow-up assessment of regional left ventricular volume using 3-Dimensional echocardiography: comparison with cardiac magnetic resonance. Cardiovasc Ultrasound 2009; 7:55. [PMID: 19925678 PMCID: PMC2787483 DOI: 10.1186/1476-7120-7-55] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2009] [Accepted: 11/19/2009] [Indexed: 11/10/2022] Open
Abstract
The assessment of regional volumes is an option for analysis of the response of LV segments to interventions such as revascularization or cell therapy. We sought to compare regional volumes from 3D-echocardiography (3DE) with cardiac magnetic resonance (CMR) over follow-up. CMR regional volumes were assessed at baseline and after one year follow-up in 30 unselected patients (28 men, 65 +/- 11 years) presenting for evaluation of cardiac function with previous infarction. 3DE images were also gathered over 4 cardiac cycles and measurements were performed off-line. CMR images were obtained using a 1.5 Tesla scanner and measured offline by method of landmarks and by centre of mass. Regional volumes were measured at end-diastole (rEDV) and end-systole (rESV) and the change in volume was compared for each over follow-up. There was good correlation between 3DE and both CMR methods at baseline and follow-up. Changes in rEDV with 3DE vs CMR(L) were comparable (0.11 +/- 3 ml vs 0.12 +/- 3 ml, p = 0.94), as was change in CMR(M) (0.26 +/- 2 ml, p = 0.69). However the change in regional volume by 3DE and CMR(L) correlated poorly (r = 0.03, p = 0.68), as did change in 3DE vs CMR(M) (r = 0.04, p = 0.65). Similarly, changes in rESV with 3DE and CMR(L) were similar (0.27 +/- 2 ml vs 0.36 +/- 2 ml, p = 0.70), as was change in CMR(M) (0.05 +/- 1 ml, p = 0.31). Again, correlations between rESV by 3DE vs CMR(L) were poor (r = 0.03, p = 0.72), as well as 3DE vs CMR(M) (r = 0.07, p = 0.40). Although global 3DE volumes compare well with CMR volumes, new developments in image quality and automated software will be needed before changes in regional volumes can be reliably followed with 3DE.
Collapse
Affiliation(s)
- Carly Jenkins
- Department of Medicine, University of Queensland, Brisbane, Australia.
| | | |
Collapse
|
170
|
Evaluation of intracardiac masses using three-dimensional echocardiography. CURRENT CARDIOVASCULAR IMAGING REPORTS 2009. [DOI: 10.1007/s12410-009-0041-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
171
|
Ren M, Tian JW, Leng XP, Wang HM, Wang Y, Wang ZZ. Assessment of global and regional left ventricular function after surgical revascularization in patients with coronary artery disease by real-time triplane echocardiography. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2009; 28:1175-1184. [PMID: 19710215 DOI: 10.7863/jum.2009.28.9.1175] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVE The purpose of this study was to evaluate the capability of real-time triplane echocardiography (RT3PE) for monitoring global and regional systolic function of the left ventricle (LV) after surgical revascularization and for evaluating the effect of surgery and predicting restenosis. METHODS Forty-nine patients underwent RT3PE before and at 10 days and 1, 3, and 6 months after coronary artery bypass grafting (CABG). The global systolic function of the LV was assessed with the parameters of end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and stroke volume (SV). The regional myocardial deformation was detected by triplane strain rate imaging. Recovery of myocardial function after surgery and the correlation between global and regional function were investigated. RESULTS In 41 of the 49 patients, the EDV and ESV decreased, and the EF and SV increased gradually and showed statistical significance at 3 and 6 months after surgery (P < .05; P < .01). The systolic strain rate (SR(sys)) and systolic strain (S(sys)) increased, and the postsystolic strain index (PSI) decreased progressively after CABG, with significant changes in almost all studied segments at 6 months (P < .05; P < .01). In addition, recovery of the SR(sys), S(sys), and PSI at each follow-up stage after surgery correlated well with EF improvement, with a positive correlation between the SR(sys), S(sys), and EF and a negative correlation between the PSI and EF. Restenosis was suspected in the other 8 patients. The sensitivity, specificity, and accuracy of RT3PE to predict restenosis were 75.00%, 89.47%, and 85.19%, respectively. CONCLUSIONS Real-time triplane echocardiography can be used to quantitatively assess global and regional myocardial function. It may represent a new, powerful method to monitor improvement of myocardial function after CABG and to predict restenosis.
Collapse
Affiliation(s)
- Min Ren
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, China
| | | | | | | | | | | |
Collapse
|
172
|
The use of real-time three-dimensional echocardiography for the quantification of left ventricular volumes and function. Curr Opin Cardiol 2009; 24:402-9. [DOI: 10.1097/hco.0b013e32832cbb8a] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
173
|
|
174
|
Flu WJ, van Kuijk JP, Bax JJ, Gorcsan J, Poldermans D. Three-dimensional speckle tracking echocardiography: a novel approach in the assessment of left ventricular volume and function? Eur Heart J 2009; 30:2304-7. [DOI: 10.1093/eurheartj/ehp343] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
|
175
|
San Román JA, Candell-Riera J, Arnold R, Sánchez PL, Aguadé-Bruix S, Bermejo J, Revilla A, Villa A, Cuéllar H, Hernández C, Fernández-Avilés F. Quantitative analysis of left ventricular function as a tool in clinical research. Theoretical basis and methodology. Rev Esp Cardiol 2009; 62:535-51. [PMID: 19406068 DOI: 10.1016/s1885-5857(09)71836-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The usefulness the left ventricular ejection fraction as a surrogate endpoint in clinical trials has been confirmed by numerous studies. However, if this approach is to be applied successfully, images must be acquired in a rigorously controlled manner, and it is advisable to use measurement units that have been specifically developed for quantitative analysis of the imaging parameters obtained with current imaging techniques. This review summarizes what is now known about the left ventricular ejection fraction and left ventricular volumes, discusses the importance of measurement units in image analysis, and describes the different imaging techniques available. Finally, there is a discussion of how to select the best imaging technique for specific clinical applications.
Collapse
|
176
|
Hare JL, Brown JK, Leano R, Jenkins C, Woodward N, Marwick TH. Use of myocardial deformation imaging to detect preclinical myocardial dysfunction before conventional measures in patients undergoing breast cancer treatment with trastuzumab. Am Heart J 2009; 158:294-301. [PMID: 19619708 DOI: 10.1016/j.ahj.2009.05.031] [Citation(s) in RCA: 149] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2009] [Accepted: 05/29/2009] [Indexed: 11/26/2022]
Abstract
BACKGROUND Trastuzumab prolongs survival in patients with human epidermal growth factor receptor type 2-positive breast cancer. Sequential left ventricular (LV) ejection fraction (EF) assessment has been mandated to detect myocardial dysfunction because of the risk of heart failure with this treatment. Myocardial deformation imaging is a sensitive means of detecting LV dysfunction, but this technique has not been evaluated in patients treated with trastuzumab. The aim of this study was to investigate whether changes in tissue deformation, assessed by myocardial strain and strain rate (SR), are able to identify LV dysfunction earlier than conventional echocardiographic measures in patients treated with trastuzumab. METHODS Sequential echocardiograms (n = 152) were performed in 35 female patients (51 +/- 8 years) undergoing trastuzumab therapy for human epidermal growth factor receptor type 2-positive breast cancer. Left ventricular EF was measured by 2- and 3-dimensional (2D and 3D) echocardiography, and myocardial deformation was assessed using tissue Doppler imaging and 2D-based (speckle-tracking) strain and SR. Change over time was compared every 3 months between baseline and 12 months. RESULTS There was no overall change in 3D-EF, 2D-EF, myocardial E-velocity, or strain. However, there were significant reductions seen in tissue Doppler imaging SR (P < .05), 2D-SR (P < .001), and 2D radial SR (P < .001). A drop > or =1 SD in 2D longitudinal SR was seen in 18 (51%) patients; 13 (37%) had a similar drop in radial SR. Of the 18 patients with reduced longitudinal SR, 3 had a concurrent reduction in EF > or =10%, and another 2 showed a reduction over 20 months follow-up. CONCLUSIONS Myocardial deformation identifies preclinical myocardial dysfunction earlier than conventional measures in women undergoing treatment with trastuzumab for breast cancer.
Collapse
|
177
|
Aune E, Baekkevar M, Rodevand O, Otterstad JE. The limited usefulness of real-time 3-dimensional echocardiography in obtaining normal reference ranges for right ventricular volumes. Cardiovasc Ultrasound 2009; 7:35. [PMID: 19580673 PMCID: PMC2713207 DOI: 10.1186/1476-7120-7-35] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2009] [Accepted: 07/06/2009] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND To obtain normal reference ranges and intraobserver variability for right ventricular (RV) volume indexes (VI) and ejection fraction (EF) from apical recordings with real-time 3-dimensional echocardiography (RT3DE), and similarly for RV area indexes (AI) and area fraction (AF) with 2-dimensional echocardiography (2DE). METHODS 166 participants; 79 males and 87 females aged between 29-79 years and considered free from clinical and subclinical cardiovascular disease. Normal ranges are defined as 95% reference values and reproducibility as coefficients of variation (CV) for repeated measurements. RESULTS None of the apical recordings with RT3DE and 2DE included the RV outflow tract. Upper reference values were 62 ml/m2 for RV end-diastolic (ED) VI and 24 ml/m2 for RV end-systolic (ES) VI. Lower normal reference value for RVEF was 41%. The respective reference ranges were 17 cm2/m2 for RVEDAI, 11 cm2/m2 for RVESAI and 27% for RVAF. Males had higher upper normal values for RVEDVI, RVESVI and RVEDAI, and a lower limit than females for RVEF and RVAF. Weak but significant negative correlations between age and RV dimensions were found with RT3DE, but not with 2DE. CVs for repeated measurements ranged between 10% and 14% with RT3DE and from 5% to 14% with 2DE. CONCLUSION Although the normal ranges for RVVIs and RVAIs presented in this study reflect RV inflow tract dimensions only, the data presented may still be regarded as a useful tool in clinical practice, especially for RVEF and RVAF.
Collapse
Affiliation(s)
- Erlend Aune
- Department of Cardiology, Vestfold Hospital Trust, Box 2168, NO-3103 Toensberg, Norway
| | - Morten Baekkevar
- Department of Cardiology, Vestfold Hospital Trust, Box 2168, NO-3103 Toensberg, Norway
| | - Olaf Rodevand
- Department of Cardiology, Feiringklinikken, Feiring, Norway
| | - Jan Erik Otterstad
- Department of Cardiology, Vestfold Hospital Trust, Box 2168, NO-3103 Toensberg, Norway
| |
Collapse
|
178
|
Cosyns B, Haberman D, Droogmans S, Warzée S, Mahieu P, Laurent E, Moonen M, Hernot S, Lancellotti P. Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function. Cardiovasc Ultrasound 2009; 7:27. [PMID: 19531259 PMCID: PMC2702292 DOI: 10.1186/1476-7120-7-27] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2009] [Accepted: 06/16/2009] [Indexed: 12/02/2022] Open
Abstract
Background In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 ± 65 mL and was underestimated by triplane contrast RT3DE (128 ± 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 ± 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 ± 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 ± 15%) and full-volume contrast RT3DE (45 ± 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease.
Collapse
Affiliation(s)
- Bernard Cosyns
- CHIREC, Cardiology department, Free University of Brussels, Belgium.
| | | | | | | | | | | | | | | | | |
Collapse
|
179
|
Delgado V, Bax JJ, van der Wall EE. Towards assessment of left ventricular mechanics in true three dimensions. Eur Heart J 2009; 30:1554-5. [PMID: 19487237 DOI: 10.1093/eurheartj/ehp218] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
180
|
Mor-Avi V, Jenkins C, Kühl HP, Nesser HJ, Marwick T, Franke A, Ebner C, Freed BH, Steringer-Mascherbauer R, Pollard H, Weinert L, Niel J, Sugeng L, Lang RM. Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error. JACC Cardiovasc Imaging 2009; 1:413-23. [PMID: 19356461 DOI: 10.1016/j.jcmg.2008.02.009] [Citation(s) in RCA: 254] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2008] [Revised: 01/25/2008] [Accepted: 02/06/2008] [Indexed: 12/17/2022]
Abstract
OBJECTIVES We sought to study: 1) the accuracy and reproducibility of real-time 3-dimensional echocardiographic (RT3DE) analysis of left ventricular (LV) volumes in a multicenter setting, 2) interinstitutional differences in relationship with the investigators' specific experience, and 3) potential sources of volume underestimation. BACKGROUND Reproducibility and accuracy of RT3DE evaluation of LV volumes has not been validated in multicenter studies, and LV volumes have been reported to be underestimated compared to cardiac magnetic resonance (CMR) standard. METHODS A total of 92 patients with a wide range of ejection fractions underwent CMR and RT3DE imaging at 4 different institutions. Images were analyzed to obtain LV end-systolic volume (ESV) and end-diastolic volume (EDV). Reproducibility was assessed using repeated analyses. The investigation of potential sources of error included: phantom imaging, intermodality analysis-related differences, and differences in LV boundary identification, such as inclusion of endocardial trabeculae and mitral valve plane in the LV volume. RESULTS The RT3DE-derived LV volumes correlated highly with CMR values (EDV: r = 0.91; ESV: r = 0.93), but were 26% and 29% lower consistently across institutions, with the magnitude of the bias being inversely related to the level of experience. The RT3DE measurements were less reproducible (4% to 13%) than CMR measurements (4% to 7%). Minimal changes in endocardial surface position (1 mm) resulted in significant differences in measured volumes (11%). Exclusion of trabeculae and mitral valve plane from the CMR reference eliminated the intermodality bias. CONCLUSIONS The RT3DE-derived LV volumes are underestimated in most patients because RT3DE imaging cannot differentiate between the myocardium and trabeculae. To minimize this difference, tracing the endocardium to include trabeculae in the LV cavity is recommended. With the understanding of these intermodality differences, RT3DE quantification of LV volume is a reliable tool that provides clinically useful information.
Collapse
Affiliation(s)
- Victor Mor-Avi
- University of Chicago Medical Center, Chicago, Illinois 60637, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
181
|
Nesser HJ, Mor-Avi V, Gorissen W, Weinert L, Steringer-Mascherbauer R, Niel J, Sugeng L, Lang RM. Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI. Eur Heart J 2009; 30:1565-73. [PMID: 19482868 DOI: 10.1093/eurheartj/ehp187] [Citation(s) in RCA: 193] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Although the utility of two-dimensional (2D) speckle tracking echocardiography (STE) to quantify left ventricular (LV) volume has been demonstrated, this methodology is limited by foreshortened views, geometric modelling, and the assumption that speckles can be tracked from frame to frame, despite their out of plane motion. To circumvent these limitations, a three-dimensional (3D) speckle tracking algorithm was recently developed. Our goal was to evaluate the accuracy of the new 3D-STE side by side with 2D-STE using cardiac magnetic resonance (CMR) as a reference. METHODS AND RESULTS Apical two- and four-chamber views (A2C and A4C) and real-time 3D datasets (Toshiba Artida 4D System) obtained in 43 patients with a wide range of LV size and function were analysed to measure LV end-systolic and end-diastolic volumes (ESV and EDV) using 2D and 3D-STE techniques. Short-axis CMR images (Siemens 1.5T scanner) acquired on the same day were analysed to obtain ESV and EDV reference values using the method of disks approximation. Reproducibility of both STE techniques was assessed using repeated measurements. While 2D-STE correlated well with CMR (r: 0.72-0.88), it underestimated LV volumes with relatively large biases (10-30 mL) and wide limits of agreement (SD: 36-51 mL), with A2C-derived measurements being worse than A4C values. The 3D-STE measurements showed higher correlation with CMR (0.87-0.92), and importantly smaller biases (1-16 mL) and narrower limits of agreement (SD: 28-37 mL). In addition, 3D-STE showed lower inter- and intra-observer variability (11-14% and 12-13%), than 2D-STE (16-17% and 12-16%, respectively). CONCLUSION This is the first study to validate the new 3D-STE technique for LV volume measurements and demonstrate its superior accuracy and reproducibility over previously used 2D-STE technique.
Collapse
|
182
|
|
183
|
Análisis cuantitativo de la función ventricular izquierda como herramienta para la investigación clínica. Fundamentos y metodología. Rev Esp Cardiol 2009. [DOI: 10.1016/s0300-8932(09)71034-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
184
|
Hansegård J, Urheim S, Lunde K, Malm S, Rabben SI. Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography. Cardiovasc Ultrasound 2009; 7:18. [PMID: 19379479 PMCID: PMC2678991 DOI: 10.1186/1476-7120-7-18] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2009] [Accepted: 04/20/2009] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Recent studies have shown that real-time three-dimensional (3D) echocardiography (RT3DE) gives more accurate and reproducible left ventricular (LV) volume and ejection fraction (EF) measurements than traditional two-dimensional methods. A new semi-automated tool (4DLVQ) for volume measurements in RT3DE has been developed. We sought to evaluate the accuracy and repeatability of this method compared to a 3D echo standard. METHODS LV end-diastolic volumes (EDV), end-systolic volumes (ESV), and EF measured using 4DLVQ were compared with a commercially available semi-automated analysis tool (TomTec 4D LV-Analysis ver. 2.2) in 35 patients. Repeated measurements were performed to investigate inter- and intra-observer variability. RESULTS Average analysis time of the new tool was 141s, significantly shorter than 261s using TomTec (p < 0.001). Bland Altman analysis revealed high agreement of measured EDV, ESV, and EF compared to TomTec (p = NS), with bias and 95% limits of agreement of 2.1 +/- 21 ml, -0.88 +/- 17 ml, and 1.6 +/- 11% for EDV, ESV, and EF respectively. Intra-observer variability of 4DLVQ vs. TomTec was 7.5 +/- 6.2 ml vs. 7.7 +/- 7.3 ml for EDV, 5.5 +/- 5.6 ml vs. 5.0 +/- 5.9 ml for ESV, and 3.0 +/- 2.7% vs. 2.1 +/- 2.0% for EF (p = NS). The inter-observer variability of 4DLVQ vs. TomTec was 9.0 +/- 5.9 ml vs. 17 +/- 6.3 ml for EDV (p < 0.05), 5.0 +/- 3.6 ml vs. 12 +/- 7.7 ml for ESV (p < 0.05), and 2.7 +/- 2.8% vs. 3.0 +/- 2.1% for EF (p = NS). CONCLUSION In conclusion, the new analysis tool gives rapid and reproducible measurements of LV volumes and EF, with good agreement compared to another RT3DE volume quantification tool.
Collapse
|
185
|
Tsai CT, Hung CL, Hou CJY, Hung TC, Yeh HI, Tsai CH. Real-Time Three-Dimensional Echocardiography in the Evaluation of Left Atrial Structure and Function in Normal, Aging, Hypertensive and Heart Failure Patients: New Insights into Left Atrial Adaptation and Remodeling. INT J GERONTOL 2009. [DOI: 10.1016/s1873-9598(09)70021-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
186
|
Real-time three-dimensional echocardiographic assessment of left ventricular remodeling index in patients with hypertensive heart disease and coronary artery disease. JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY. MEDICAL SCIENCES = HUA ZHONG KE JI DA XUE XUE BAO. YI XUE YING DE WEN BAN = HUAZHONG KEJI DAXUE XUEBAO. YIXUE YINGDEWEN BAN 2009; 29:122-6. [PMID: 19224178 DOI: 10.1007/s11596-009-0126-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2009] [Indexed: 01/19/2023]
Abstract
Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controls (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi ) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass /EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P<0.01). There was no significant difference in NC group (P>0.05), but significant difference in HHD and CAD intra-group (P<0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (r=0.69, P<0.01; r=0.68, P<0.01), but no significant correlation in CAD group (r=0.30, P>0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE.
Collapse
|
187
|
Solis J, Sitges M, Levine RA, Hung J. Ecocardiografía tridimensional. Nuevas perspectivas sobre la caracterización de la válvula mitral. Rev Esp Cardiol 2009. [DOI: 10.1016/s0300-8932(09)70161-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
188
|
Ballo P, Motto A, Mondillo S, Galderisi M. Three-dimensional echocardiography for optimization of cardiac resynchronization therapy. Eur Heart J 2009; 30:505; author reply 505-6. [PMID: 19168528 DOI: 10.1093/eurheartj/ehp001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
189
|
Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: insights from three-dimensional echocardiography and cardiac magnetic resonance imaging. J Am Soc Echocardiogr 2009; 21:990-7. [PMID: 18765174 DOI: 10.1016/j.echo.2008.07.009] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
BACKGROUND The accuracy of left ventricular (LV) volumes and ejection fraction (EF) on two-dimensional echocardiography (2DE) is limited by image position (IP), geometric assumption (GA), and boundary tracing (BT) errors. METHODS Real-time three-dimensional echocardiography (RT3DE) and cardiac magnetic resonance imaging (CMR) were used to determine the relative contribution of each error source in normal controls (n = 35) and patients with myocardial infarctions (MIs) (n = 34). LV volumes and EFs were calculated using (1) apical biplane disk summation on 2DE (IP + GA + BT errors), (2) biplane disk summation on RT3DE (GA + BT errors), (3) 4-multiplane to 8-multiplane surface approximation on RT3DE (GA + BT errors), (4) voxel-based surface approximation on RT3DE (BT error alone) and (5) CMR. By comparing each method with CMR, the absolute and relative contributions of each error source were determined. RESULTS IP error predominated in LV volume quantification on 2DE in normal controls, whereas GA error predominated in patients with MIs. Underestimation of volumes on 2DE was overcome by increasing the number of imaging planes on RT3DE. Although 4 equidistant image planes were acceptable, the best results were achieved with voxel-based RT3DE. For EF estimation, IP error predominated in normal controls, whereas BT error predominated in patients with MIs. Nevertheless, one third of the EF estimation error in patients with MIs was due to a combination of IP and GA errors, both of which may be addressed using RT3DE. CONCLUSIONS The relative contribution of each source of LV quantitation error on 2DE was defined and quantified. Each source of error differed depending on patient characteristics and LV geometry.
Collapse
|
190
|
Takeuchi M, Nishikage T, Mor-Avi V, Sugeng L, Weinert L, Nakai H, Salgo IS, Gerard O, Lang RM. Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and m-mode measurements. J Am Soc Echocardiogr 2009; 21:1001-5. [PMID: 18765176 DOI: 10.1016/j.echo.2008.07.008] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND The recent development of 3-dimensional (3D) surface detection algorithm of the endocardial and epicardial surfaces from real-time 3D echocardiographic (RT3DE) datasets allows direct semiautomated quantification of left ventricular mass (LVM). Our aims were to (1) evaluate the accuracy of RT3DE measurements of LVM using this algorithm against cardiac magnetic resonance (CMR) reference and (2) compare RT3DE LVM with conventional M-mode, 2-dimensional (2D), and RT3DE-guided biplane measurements. METHODS A total of 205 patients were studied in 2 protocols: (1) RT3DE and CMR imaging was performed on the same day in 55 subjects; (2) in an additional 150 subjects, RT3DE, 2D, and M-mode images were acquired. In both protocols, RT3DE endocardial and epicardial surfaces were semiautomatically identified at end diastole (QLab, Philips Medical Systems, Andover, MA) to calculate LVM. CMR, 2D, and M-mode-derived LVM were obtained using standard techniques. RESULTS A significant correlation (r = 0.95) was noted between RT3DE and CMR-derived LVM with a small bias of -2 g. M-mode-derived LVM measurements (175 +/- 64 g) were significantly larger than RT3DE LVM (123 +/- 39 g, bias: 52 g) with moderate correlation (r = 0.76). No significant differences in LVM were noted between 2D (125 +/- 42 g) and RT3DE values (bias: 1.2 g) with good correlation (r = 0.91, P < .001). However, the best correlation was noted between RT3DE and RT3DE-guided biplane LVM values (r = 0.95, P < .001, bias: -4.6 g). Intraobserver, interobserver variability, and test-retest variability of the RT3DE measurements were 9%, 12%, and 6%, respectively. CONCLUSION RT3DE imaging using the 3D surface detection algorithm allows accurate and reproducible measurements of LVM. RT3DE-guided biplane technique can be used as an accurate time-saving alternative in clinical practice.
Collapse
Affiliation(s)
- Masaaki Takeuchi
- Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
191
|
Nishikage T, Nakai H, Mor-Avi V, Lang RM, Salgo IS, Settlemier SH, Husson S, Takeuchi M. Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2009; 10:82-8. [DOI: 10.1093/ejechocard/jen166] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
192
|
Three-Dimensional Echocardiography. Echocardiography 2009. [DOI: 10.1007/978-1-84882-293-1_31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
193
|
Nucifora G, Badano LP, Dall'Armellina E, Gianfagna P, Allocca G, Fioretti PM. Fast Data Acquisition and Analysis with Real Time Triplane Echocardiography for the Assessment of Left Ventricular Size and Function: A Validation Study. Echocardiography 2009; 26:66-75. [DOI: 10.1111/j.1540-8175.2008.00762.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
194
|
Real Time Transthoracic Three-Dimensional Echocardiography: How Should it be Applied in the Clinical Setting? J Med Ultrasound 2009. [DOI: 10.1016/s0929-6441(09)60113-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
195
|
Three-dimensional echocardiography for management of structural heart disease. CURRENT CARDIOVASCULAR RISK REPORTS 2008. [DOI: 10.1007/s12170-008-0066-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
196
|
Anwar AM, Nosir YFM. Role of Real Time Three-Dimensional Echocardiography in Heart Failure. Echocardiography 2008; 25:983-92. [DOI: 10.1111/j.1540-8175.2008.00746.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
197
|
Three-dimensional echocardiography: What is next? CURRENT CARDIOVASCULAR IMAGING REPORTS 2008. [DOI: 10.1007/s12410-008-0008-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
198
|
Stanton T, Hawkins NM, Hogg KJ, Goodfield NE, Petrie MC, McMurray JJ. Three-dimensional echocardiography for optimization of cardiac resynchronization therapy: reply. Eur Heart J 2008. [DOI: 10.1093/eurheartj/ehp002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
199
|
Ma XJ, Huang GY, Liu F, Wu L, Sheng F, Tao ZY. The impacts of transcatheter occlusion for congenital atrial septal defect on atrial volume, function, and synchronicity in children: a three-dimensional echocardiography study. Echocardiography 2008; 25:1101-11. [PMID: 18771544 DOI: 10.1111/j.1540-8175.2008.00730.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVE To evaluate the impacts of transcatheter closure for atrial septal defect (ASD) on the atria. METHODS Thirty-four patients with ASD undergoing transcatheter occlusion were recruited in the study, and 34 patients undergoing surgical operation and 34 healthy children were age-matched as controls. A real time three-dimensional (RT3DE) echocardiography was used to measure the volume, function, and synchronicity of the atria. RESULTS There was no difference in the atrial volume and function between the transcatheter occlusion group and healthy control group (P > 0.05). However, the parameters reflecting the atrial asynchrony were larger in the transcatheter occlusion group (P < 0.05). Compared to the surgical repair group, the transcatheter occlusion group had smaller maximum volume of the left atrium (21.0 +/- 5.2 ml/m(2) vs 24.3 +/- 5.8 ml/m(2), P = 0.01), smaller total emptying volume of the left atrium (12.7 +/- 4.3 ml/m(2) vs 15.1 +/- 3.8 ml/m(2), P = 0.014), smaller total emptying volume of the right atrium (13.5 +/- 5.2 ml/m(2) vs 16.1 +/- 4.7 ml/m(2), P = 0.029), and larger atrial systolic asynchrony indices. CONCLUSIONS An atrial asynchrony is observed in patients with transcatheter closure of ASD, although little negative impacts on the atrial volume and function are demonstrated, which deserves more attention during follow-up of this specific population.
Collapse
Affiliation(s)
- Xiao-Jing Ma
- Department of Pediatrics, Pediatric Heart Center, Children's Hospital of Fudan University, Shanghai Medical School, Fudan University, Shanghai, People's Republic of China
| | | | | | | | | | | |
Collapse
|
200
|
|