201
|
Jiranek WA, Hanssen AD, Greenwald AS. Antibiotic-loaded bone cement for infection prophylaxis in total joint replacement. J Bone Joint Surg Am 2006; 88:2487-500. [PMID: 17079409 DOI: 10.2106/jbjs.e.01126] [Citation(s) in RCA: 230] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Use of antibiotic-loaded bone cement for prophylaxis against infection is not indicated for patients not at high risk for infection who are undergoing routine primary or revision joint replacement with cement. The mechanical and elution properties of commercially available premixed antibiotic-loaded bone-cement products are superior to those of hand-mixed preparations. Use of commercially available antibiotic-loaded bone-cement products has been cleared by the United States Food and Drug Administration only for use in the second stage of a two-stage total joint revision following removal of the original prosthesis and elimination of active periprosthetic infection. Use of antibiotic-loaded bone cement for prophylaxis against infection in the second stage of a two-stage total joint revision involves low doses of antibiotics. Active infection cannot be treated with commercially available antibiotic-loaded bone cement as such treatment requires higher doses of antibiotics.
Collapse
Affiliation(s)
- William A Jiranek
- Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, P.O. Box 980153, Richmond, VA 23298-0153, USA
| | | | | |
Collapse
|
202
|
JIRANEK WILLIAMA, HANSSEN ARLEND, GREENWALD ASETH. ANTIBIOTIC-LOADED BONE CEMENT FOR INFECTION PROPHYLAXIS IN TOTAL JOINT REPLACEMENT. J Bone Joint Surg Am 2006. [DOI: 10.2106/00004623-200611000-00024] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
203
|
Eskandari MM, Ozturk OG, Eskandari HG, Balli E, Yilmaz C. Cyanoacrylate adhesive provides efficient local drug delivery. Clin Orthop Relat Res 2006; 451:242-50. [PMID: 16760809 DOI: 10.1097/01.blo.0000224055.24743.c8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Biodegradable drug delivery systems have advanced treatment of a wide spectrum of musculoskeletal problems. However, their lack of availability and cost can restrict use. To find an easily available and inexpensive biodegradable implant, we tested a widely used tissue adhesive, n-butyl-2-cyanoacrylate, as a drug-trapping material. We tested vancomycin with commercially available absorbable gelatin-sponge pieces as the scaffold. We evaluated the in vitro and in vivo drug release profiles and in vivo inflammatory response. A mouse muscle pouch model was used for in vivo evaluations. The released vancomycin level was measured by fluorescence polarization immunoassay technique, and a leukocyte count-based grading system was used to evaluate inflammatory response. Our findings suggest the proposed implant provides effective drug release for as much as 42 days in vitro and 14 days in vivo. The presence of n-butyl-2-cyanoacrylate led to a local inflammatory response which decreased after 3 weeks in the group with less adhesive. These results showed that n-butyl-2-cyanoacrylate could efficiently trap and slowly release a drug when used in the structure of a biodegradable local drug delivery device.
Collapse
|
204
|
Kälicke T, Schierholz J, Schlegel U, Frangen TM, Köller M, Printzen G, Seybold D, Klöckner S, Muhr G, Arens S. Effect on infection resistance of a local antiseptic and antibiotic coating on osteosynthesis implants: an in vitro and in vivo study. J Orthop Res 2006; 24:1622-40. [PMID: 16779814 DOI: 10.1002/jor.20193] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to acquire information about the effect of an antibacterial and biodegradable poly-L-lactide (PLLA) coated titanium plate osteosynthesis on local infection resistance. For our in vitro and in vivo experiments, we used six-hole AO DC minifragment titanium plates. The implants were coated with biodegradable, semiamorphous PLLA (coating about 30 microm thick). This acted as a carrier substance to which either antibiotics or antiseptics were added. The antibiotic we applied was a combination of Rifampicin and fusidic acid; the antiseptic was a combination of Octenidin and Irgasan. This produced the following groups: Group I: six-hole AO DC minifragment titanium plate without PLLA; Group II: six-hole AO DC minifragment titanium plate with PLLA without antibiotics/antiseptics; Group III: six-hole AO DC minifragment titanium plate with PLLA + 3% Rifampicin and 7% fusidic acid; Group IV: six-hole AO DC minifragment titanium plate with PLLA + 2% Octenidin and 8% Irgasan. In vitro, we investigated the degradation and the release of the PLLA coating over a period of 6 weeks, the bactericidal efficacy of antibiotics/antiseptics after their release from the coating and the bacterial adhesion of Staphylococcus aureus to the implants. In vivo, we compared the infection rates in white New Zealand rabbits after titanium plate osteosynthesis of the tibia with or without antibacterial coating after local percutaneous bacterial inoculations at different concentrations (2 x 10(5)-2 x 10(8)): The plate, the contaminated soft tissues and the underlying bone were removed under sterile conditions after 28 days and quantitatively evaluated for bacterial growth. A stepwise experimental design with an "up-and-down" dosage technique was used to adjust the bacterial challenge in the area of the ID50 (50% infection dose). Statistical evaluation of the differences between the infection rates of both groups was performed using the two-sided Fisher exact test (p < 0.05). Over a period of 6 weeks, a continuous degradation of the PLLA coating of 13%, on average, was seen in vitro in 0.9% NaCl solution. The elution tests on titanium implants with antibiotic or antiseptic coatings produced average release values of 60% of the incorporated antibiotic or 62% of the incorporated antiseptic within the first 60 min. This was followed by a much slower, but nevertheless continuous, release of the incorporated antibiotic and antiseptic over days and weeks. At the end of the test period of 42 days, 20% of the incorporated antibiotic and 15% of the incorporated antiseptic had not yet been released from the coating. The antibacterial effect of the antibiotic/antiseptic is not lost by integrating it into the PLLA coating. The overall infection rate in the in vivo investigation was 50%. For Groups I and II the infection rate was both 83% (10 of 12 animals). In Groups III and IV with antibacterial coating, the infection rate was both 17% (2 of 12 animals). The ID50 in the antibacterial coated Groups III and IV was recorded as 1 x 10(8) CFU, whereas the ID50 values in the Groups I and II without antibacterial coating were a hundred times lower at 1 x 10(6) CFU, respectively. The difference between the groups with and without antibacterial coating was statistically significant (p = 0.033). Using an antibacterial biodegradable PLLA coating on titanium plates, a significant reduction of infection rate in an in vitro and in vivo investigation could be demonstrated. For the first time, to our knowledge, we were able to show, under standardized and reproducible conditions, that an antiseptic coating leads to the same reduction in infection rate as an antibiotic coating. Taking the problem of antibiotic-induced bacterial resistance into consideration, we thus regard the antiseptic coating, which shows the same level of effectiveness, as advantageous.
Collapse
Affiliation(s)
- Thomas Kälicke
- Berufsgenossenschaftliche Kliniken Bergmannsheil, Chirurgische Klinik und Poliklinik, Universitätsklinik, Bürkle-de-la-Camp-Platz 1, 44789 Bochum, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
205
|
Harris LG, Mead L, Müller-Oberländer E, Richards RG. Bacteria and cell cytocompatibility studies on coated medical grade titanium surfaces. J Biomed Mater Res A 2006; 78:50-8. [PMID: 16602121 DOI: 10.1002/jbm.a.30611] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Acute and chronic osteomyelitis caused by staphylococci can be difficult to treat by conventional means and often has marked consequences for the patient. Current methods of treatment involve the use of systemic antibiotics, the local implantation of nondegradable drug carriers, and surgical debridement. A possible solution that could prevent initial bacterial adhesion could be to modify the implant surface with an antimicrobial coating while maintaining biocompatibility to host cells. This study describes the cytocompatibility evaluation of different coatings (poly(D,L-lactide) (PDLLA), politerefate (PTF), calcium phosphate/anodic plasma-chemical treatment (CaP/APC), polyurethane (PU), and polyvinylpyrollidone (PVP) on titanium surfaces with and without chlorhexidine diacetate (CHA) to Staphylococcus aureus, Staphylococcus epidermidis, and hTERT human fibroblasts. Surface characterization of the coatings showed no significant variation in the roughness or hydrophobicity of the coated surfaces, except the CaP/APC surface that was porous yet the smoothest, and PVP, PVP+CHA, and CaP/APC+CHA that were more hydrophilic in nature than the others. On the surfaces without CHA, both staphylococcal strains and spread fibroblasts were observed, but on the CHA impregnated surfaces few bacteria and no intact fibroblasts were seen. Flow cytometry found fewer bacteria in the media and on the surfaces containing CHA in comparison to the surfaces without CHA. The release kinetics varied from slow (over 200 h) to burst release: PDLLA>PTF>PU>CaP/APC=PVP. This study showed that PDLLA and PTF have the best potential as coatings on implants for drug delivery, as they were cytocompatible to hTERT fibroblasts, eluted CHA effectively, and passed mechanical testing. The actual release kinetics of PDLLA and PTF are important, as the amount of CHA present should remain above the minimal inhibitory concentration value for a limited time before disappearing completely.
Collapse
Affiliation(s)
- L G Harris
- AO Research Institute, Clavadelerstrasse, 7270 Davos, Switzerland.
| | | | | | | |
Collapse
|
206
|
Orhan Z, Cevher E, Mülazimoglu L, Gürcan D, Alper M, Araman A, Ozsoy Y. The preparation of ciprofloxacin hydrochloride-loaded chitosan and pectin microspheres: their evaluation in an animal osteomyelitis model. ACTA ACUST UNITED AC 2006; 88:270-5. [PMID: 16434537 DOI: 10.1302/0301-620x.88b2.16328] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Ciprofloxacin hydrochloride-loaded microspheres were prepared by a spray-drying method using pectin and chitosan. The effects of different polymers and drug ratios were investigated. The most appropriate carriers were selected by in vitro testing. A rat methicillin-resistant Staphylococcus aureus osteomyelitis model was used to evaluate the effects of the loaded microspheres. The drug was released rapidly from the pectin carrier but this was more sustained in the chitosan formulation.Chitosan microspheres loaded with ciprofloxacin hydrochloride were more effective for the treatment of osteomyelitis than equivalent intramuscular antibiotics.
Collapse
Affiliation(s)
- Z Orhan
- Department of Orthopaedics, Abant Izzet Baysal University, Düzce, Turkey.
| | | | | | | | | | | | | |
Collapse
|
207
|
Abstract
Surfaces of internal fracture fixation implants are generally designed to encourage soft- and/or hard-tissue adherence, eventually leading to tissue or osseo integration. Unfortunately, this feature may also encourage bacterial adhesion. About half of the two million cases of nosocomial infections per year in the US are associated with indwelling devices. In the UK, implant-associated infections are estimated to cost pound 7-11 million per year, and with the rise in antibiotic-resistant bacteria, are an important issue. Soft-tissue infections and osteomyelitis are serious complications associated with implants, particularly open fractures, external fixation devices, and intramedullary nailing. Consequences of implant-associated infections include prolonged hospitalization with systemic antibiotic therapy, several revision procedures, possible amputation, and even death. This review discusses the issue of implant-associated infections and some of the methods used to prevent bacterial adhesion to osteosynthesis implants.
Collapse
|
208
|
Abstract
The local application of antibiotics is a well-known procedure that has been in successful clinical use for more than 20 years. The most frequently used carrier substance for the antibiotic or other antibacterial substances is polymethylmethacrylate (PMMA). However, because PMMA is not resorbable, as much as 70% of the antibiotic dose is permanently sequestered in the PMMA cement and therefore not available to combat bacterial colonization. Antibacterial coatings of metal implants represent an attractive solution to simplify the local application of an antibacterial substance in fracture care. Several coating technologies have been investigated, involving different carrier materials as well as different antibacterial substances. A fully resorbable coating containing gentamicin sulphate has yielded promising results in animal studies and intramedullary tibial nails with this coating have already been implanted successfully in a few patients. In the future, the main developmental focus for antibacterial coatings for implants will lie in tailoring the release characteristics and the antibacterial substance to minimize the risk of breeding resistant bacterial strains while maximizing the efficacy of the coating.
Collapse
|
209
|
Diefenbeck M, Mückley T, Hofmann GO. Prophylaxis and treatment of implant-related infections by local application of antibiotics. Injury 2006; 37 Suppl 2:S95-104. [PMID: 16651078 DOI: 10.1016/j.injury.2006.04.015] [Citation(s) in RCA: 144] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Despite the improvement in surgical technique and implant design in orthopedic and trauma surgery, implant-related infections are still a challenging problem for surgeons. The use of local prophylaxis to avoid infection, such as antibiotic-loaded cement in arthroplasty, gentamicin PMMA beads and gentamicin-collagen sponge in trauma surgery, and antibacterial coating of metal implants, is discussed in the first part of this article. The second part discusses the role of local antibiotics such as gentamicin PMMA beads, and gentamicin-collagen and antibiotic-loaded cement spacers in treating implant-related infections.
Collapse
Affiliation(s)
- Michael Diefenbeck
- Klinik für Unfall- und Wiederherstellungschirurgie, Berufsgenossenschaftliche Kliniken Bergmannstrost, Halle/Saale, Germany.
| | | | | |
Collapse
|
210
|
Schmidmaier G, Lucke M, Wildemann B, Haas NP, Raschke M. Prophylaxis and treatment of implant-related infections by antibiotic-coated implants: a review. Injury 2006; 37 Suppl 2:S105-12. [PMID: 16651063 DOI: 10.1016/j.injury.2006.04.016] [Citation(s) in RCA: 200] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Implant-related infection is a feared complication in orthopedic and trauma surgery with tremendous consequences for the patient. To reduce this risk, administration of perioperative antibiotic prophylaxis is a routine procedure in orthopedic surgery. A local delivery system for antibiotics based on a polymer implant coating has been developed to optimize the prophylaxis. In an animal experiment, the efficacy of local prophylaxis of gentamicin was compared to a systemic single shot of gentamicin and to a combination of both administrations. The medullary cavities of rat tibiae were contaminated with Staphylococcus aureus and titanium K-wires were implanted into the medullary canals. For local antibiotic therapy, the implants were coated with poly(D,L-Lactide) (PDLLA) loaded with gentamicin. All the animals not treated with local and systemic application of the antibiotic developed osteomyelitis and all cultures of the implants tested positive for S. aureus. Onset of infection was prevented in 80-90% of animals treated with gentamicin-coated K-wires, with and without systemic prophylaxis. Gentamicin-coated intramedullary tibial nails are CE-certified for Europe and Canada and several patients have already been treated for implant-related infection. Up to now, eight patients with open tibia fractures have been treated with an unreamed tibial nail (UTN) coated with PDLLA and gentamicin. In the 1-year follow up, none of the patients developed an infection. A prospective randomized clinical documentation is currently in progress. So far, the results suggest that a local application of gentamicin from PDLLA-coated implants might support systemic antibiotic prophylaxis in preventing implant-associated osteomyelitis.
Collapse
Affiliation(s)
- Gerhard Schmidmaier
- Centrum für Muskuloskeletale Chirurgie, Charité-Universitätsmedizin Berlin, Germany.
| | | | | | | | | |
Collapse
|
211
|
Harrell AG, Novitsky YW, Kercher KW, Foster M, Burns JM, Kuwada TS, Heniford BT. In vitro infectability of prosthetic mesh by methicillin-resistant Staphylococcus aureus. Hernia 2006; 10:120-4. [PMID: 16453077 DOI: 10.1007/s10029-005-0056-0] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2005] [Accepted: 11/16/2005] [Indexed: 10/25/2022]
Abstract
Although mesh use is important for effective herniorrhaphy in adults, prosthetic infections can cause serious morbidity. Bacterial adherence to the mesh is a known precursor to prosthetic infection. We compared the ability of common mesh prosthetics to resist bacterial adherence. The meshes studied included polypropylene (Marlex, expanded polytetrafluoroethylene (PTFE) with and without silver chlorhexidine coating (DualMesh Plus and Dualmesh) composite meshes (Composix E/X, Proceed, and Parietex Composite) and lightweight polypropylene meshes (TiMesh, Ultrapro, and Vypro). Fifteen samples of each mesh type were individually inoculated with a suspension of 10(8 )methicillin-resistant Staphylococcus aureus (MRSA) in tryptic soy broth. After incubation at 37 degrees C for 1 h, the mesh pieces were then removed and serially washed. The colony-forming units (CFU) of MRSA present in the initial inoculum, at the end of the 1-h warm-water bath (broth count), and the pooled washes (wash count), were determined using serial dilutions and spot plating. The bacteria not accounted for in the broth or wash counts were considered adhered to the mesh. Samples of each mesh type were also analyzed using scanning electron microscopy (SEM). Data are presented as the mean percentage adherence with ANOVA and Tukey's test used to determine significance (P<0.05). The DualMesh Plus mesh had no detectable MRSA in the broth or the pooled wash samples. Dualmesh had less adherence compared with Marlex, Proceed, and Vypro (P<0.05). Conversely, Vypro had a statistically higher adherence (96%, P<0.05) as compared to TiMesh, Ultrapro, Composix E/X, and Parietex Composite. SEM confirmed bacterial adherence to all the mesh types except DualMesh Plus. The ability of a biomaterial to resist infection has an important clinical significance. DualMesh Plus, due to its antimicrobial coating, is the only mesh type of the nine tested that demonstrated a bactericidal property. Standard PTFE (Dualmesh) also had less bacterial adherence. Vypro demonstrated an increase in bacterial adherence; this was possibly due to the multifilament polyglactin 910 weaved within the prolene component of the mesh.
Collapse
Affiliation(s)
- A G Harrell
- Carolinas Laparoscopic and Advanced Surgery Program, Department of General Surgery, Carolinas Medical Center, Charlotte, NC 28203, USA
| | | | | | | | | | | | | |
Collapse
|
212
|
Jose B, Antoci V, Zeiger AR, Wickstrom E, Hickok NJ. Vancomycin covalently bonded to titanium beads kills Staphylococcus aureus. ACTA ACUST UNITED AC 2006; 12:1041-8. [PMID: 16183028 DOI: 10.1016/j.chembiol.2005.06.013] [Citation(s) in RCA: 101] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2005] [Revised: 06/28/2005] [Accepted: 06/30/2005] [Indexed: 11/22/2022]
Abstract
Periprosthetic infections are life-threatening complications that occur in about 6% of medical device insertions. Stringent sterile techniques have reduced the incidence of infections, but many implant patients are at high risk for infection, especially the elderly, diabetic, and immune compromised. Moreover, because of low vascularity at the site of the new implant, antibiotic prophylaxis is often not effective. To address this problem, we designed a covalent modification to titanium implant surfaces to render them bactericidal. Specifically, we aminopropylated titanium, a widely used implant material and extended a tether by solid phase coupling of ethylene glycol linkers, followed by solid phase coupling of vancomycin. Vancomycin covalently attached to titanium still bound soluble bacterial peptidoglycan, reduced Staphylococcus aureus colony-forming units by 88% +/- 16% over 2 hr, and retained antibacterial activity upon a repeated challenge.
Collapse
Affiliation(s)
- Binoy Jose
- Department of Biochemistry and Molecular Biology, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
| | | | | | | | | |
Collapse
|
213
|
Duan K, Wang R. Surface modifications of bone implants through wet chemistry. ACTA ACUST UNITED AC 2006. [DOI: 10.1039/b517634d] [Citation(s) in RCA: 117] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
214
|
Partale K, Klein P, Schell H, Schmidmaier G, Wildemann B, Bail H, Schiller R, Bragulla H, Duda GN. Poly(D,L-lactide) coating is capable of enhancing osseous integration of Schanz screws in the absence of infection. J Biomed Mater Res B Appl Biomater 2005; 74:608-16. [PMID: 15909297 DOI: 10.1002/jbm.b.30254] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Pin loosening is a major complication in external fixation. Biological and mechanical conditions play an important role in the maintenance and enhancement of the implant-bone interface in fracture fixation. It is thought that biodegradable coatings may be capable of preventing pin track infection and pin loosening. The goal of this study was therefore to analyze the influence of a biodegradeable coating on the osseous integration of Schanz' screws during fracture treatment. Standardized osteotomies (3-mm fracture gap) of the right tibiae were performed on 16 sheep and stabilized by an AO mono-lateral external fixator. Additional, mechanically less loaded Schanz' screws were also mounted. All screws were randomly coated with biodegradable poly(D,L-lactide). The sheep were sacrificed after 9 weeks. All screws were removed and rolled on blood agar plates for microbiological analysis. Histological sections of the pin tracks were histochemically and morphometrically analyzed. Clinically, no signs of severe infection were visible. Microbiological analysis revealed 14.8% colonization by Staphylococcus aureus in the coated and 29% in the uncoated screws. Histomorphometry of the bone surrounding the Schanz' screws revealed that significantly more osseous integration had occurred on poly(D,L-lactide)-coated screws in the absence of bacterial colonization. Significantly more bone remodeling and a higher osteoclastic activity was seen near the screw-bone interface in the uncoated screw group. Up to a threefold increase in new bone formation and more severe remodeling was observed around the screw entry compared to the pin exit in all groups. Loaded screws showed significantly more callus formation around the exit sites than their less loaded counterparts. In the present study, poly(D,L-lactide) coating of Schanz' screws was found to enhance osseous integration in the absence of bacterial colonization in sheep by causing less cortical remodeling and less osteoclastic activity in the cortices compared to uncoated screws. Additionally, the coating appeared to reduce the instances of pin track infections. Mechanical loading showed an adverse effect on bone formation and remodeling. It has been shown that both biological and mechanical factors play an important role in the maintenance of osseous integrity of the pin-bone interface. Poly(D,L-lactide) coating of Schanz' screws does not prevent osseous destruction and severe bacterial colonization along the pin tracts, but can improve osseous integration of Schanz' screws in the absence of infection.
Collapse
Affiliation(s)
- K Partale
- Center for Musculoskeletral Surgery, Charité, University Medicine Berlin Free and Humboldt-University of Berlin, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
215
|
Gollwitzer H, Thomas P, Diehl P, Steinhauser E, Summer B, Barnstorf S, Gerdesmeyer L, Mittelmeier W, Stemberger A. Biomechanical and allergological characteristics of a biodegradable poly(D,L-lactic acid) coating for orthopaedic implants. J Orthop Res 2005; 23:802-9. [PMID: 16022993 DOI: 10.1016/j.orthres.2005.02.003] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Revised: 01/26/2005] [Accepted: 01/26/2005] [Indexed: 02/04/2023]
Abstract
A poly(D,L-lactic acid) surface coating (PDLLA) has been developed to optimize interactions at the implant-tissue interface. Mechanical and allergological characteristics were evaluated in the present study to elucidate possible indications and limitations prior to clinical application. Implants of stainless steel and Ti-6Al-4V and Co-Cr-Mo alloys were coated with PDLLA, and mechanical stability was studied during intramedullary implantation into rat and human cadaver bones and during dilation of coronary artery stents. Elongation resistance was examined on AlMgSi alloy specimens. Furthermore, proliferation of peripheral blood mononuclear cells of nickel-allergic donors and controls and interleukin-4 and interferon-gamma levels were measured in the presence of coated/uncoated implants and after stimulation with phytohemagglutinin or NiSO4. PDLLA remained stable on the implants with a minimum of 96% of the original coating mass and tolerated lengthening of at least 8%. Further lengthening was followed by microcracking and cohesive failure within the coating. PDLLA exerted no suppressive effect upon spontaneous and pan-T-cell mitogen inducible T-cell proliferation. Furthermore, specific proliferation to nickel in cells of nickel-allergic blood donors and production of interleukin-4 and IFN-gamma were not influenced by the coating. PDLLA coating proved high mechanical stability on different orthopaedic implants and did not influence in vitro T-cell reactivity towards specific biomaterials.
Collapse
Affiliation(s)
- Hans Gollwitzer
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Technische Universität München, Ismaninger Str. 22, 81675 München, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
216
|
Wildemann B, Sander A, Schwabe P, Lucke M, Stöckle U, Raschke M, Haas NP, Schmidmaier G. Short term in vivo biocompatibility testing of biodegradable poly(D,L-lactide)—growth factor coating for orthopaedic implants. Biomaterials 2005; 26:4035-40. [PMID: 15626449 DOI: 10.1016/j.biomaterials.2004.10.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2004] [Accepted: 10/02/2004] [Indexed: 11/28/2022]
Abstract
Fracture healing can be stimulated by exogenous application of growth factors. Using porcine and rat models the efficacy of locally delivered IGF-I and TGF-beta1 from an implant coating has been demonstrated. A thin and biomechanical stable biodegradable poly(D,L-lactide) was used to coat implants and serve as a drug carrier. Due to reports of possible foreign body reactions caused by polymer materials in orthopedic surgery, this study investigated the biocompatibility of the polylactide implant coating and the locally released growth factors during the time course of rat tibial fracture healing (days 5, 10, 15, and 28 after fracture). Monocytes/macrophages and osteoclast were detected using an monoclonal antibody against ED1 (comparable to CD68 in mice and human). The antibody ED1 stains monocytes, macrophages and osteoclast in the bone marrow and in the newly formed fracture callus. A moderate density of the monocytes/macrophages was seen in the proximal part of the medullary canal, but almost no cells were detectable in the region distal to the fracture. The amount of stained cells increased during the observation time with a maximum at days 10 and 15 followed by a decrease at day 28. No differences were detectable between the investigated groups from day 5 to 15 post fracture indicating, that the used poly(D,L-lactide) or the incorporated growth factors do not evoke an elevated immunological response compared to the uncoated titanium implant at the investigated time points. A significantly higher amount of ED1 positive cells was measured 28 days after fracture in the control group compared to the groups with the coated implants. In conclusion, no indication of a foreign body reaction due to the use of the polylactide or the growth factors was found indicating a good short-term biocompatibility of this bioactive coating.
Collapse
Affiliation(s)
- Britt Wildemann
- Center for Musculoskeletal Surgery, Charité, University Medicine, Augustenburger Platz 1, Berlin D-13353, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
217
|
Mäkinen TJ, Veiranto M, Knuuti J, Jalava J, Törmälä P, Aro HT. Efficacy of bioabsorbable antibiotic containing bone screw in the prevention of biomaterial-related infection due to Staphylococcus aureus. Bone 2005; 36:292-9. [PMID: 15780955 DOI: 10.1016/j.bone.2004.11.009] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2004] [Revised: 11/09/2004] [Accepted: 11/10/2004] [Indexed: 11/18/2022]
Abstract
Impregnation of antimicrobial agents within biodegradable orthopedic implants provides a possibility for local antimicrobial prophylaxis of biomaterial-related infections. The objective of this study was to evaluate the efficacy of a bioabsorbable ciprofloxacin containing bone screw (Ab-PLGA) in the prevention of biomaterial-related infection due to Staphylococcus aureus in a rabbit model. Animals in Group I (n=8) received a Ab-PLGA screw contaminated with S. aureus, while animals in Group II (n=8) received a stainless steel (SS) screw contaminated with S. aureus. In two negative control groups, the animals received a Ab-PLGA screw (Group III, n=4) or a SS screw (Group IV, n=4) without bacterial contamination. 18F-FDG-PET imaging, performed at 6 weeks, was applied as a novel quantitative in vivo imaging modality of implant-related infection. Infection was verified by swab cultures, direct cultures of the retrieved implant, and quantitative cultures of pulverized bone. The concentrations of ciprofloxacin in serum and local bone tissue were determined by a high performance liquid chromatographic (HPLC) method with fluorescence (FLD) detection. In the group of contaminated Ab-PLGA screws, all cultures were negative. In the group of contaminated SS screws, all cultures of retrieved implants and six cultures out of eight of pulverized bone were positive for inoculated S. aureus. In negative control groups, all cultures were negative except one contaminant (S. cohnii) found in a SS screw culture. Verified infection of contaminated SS screws was collaborated by the increased 18F-FDG-PET uptake (P=0.004 compared with the group of contaminated Ab-PLGA screws). The mean bone tissue concentration of ciprofloxacin varied from 2.54 to 0.83 microg/g bone as a function of distance from the implantation site. The serum concentration of ciprofloxacin remained undetectable and below the resolution of the analytic method (<5.0 ng/ml). This study confirmed the in vivo efficacy of bioabsorbable antibiotic containing bone screw in the prevention of biomaterial-related infection due to S. aureus.
Collapse
Affiliation(s)
- T J Mäkinen
- Department of Orthopaedic Surgery and Traumatology, Orthopaedic Research Unit, University of Turku, FIN-20520, Turku, Finland
| | | | | | | | | | | |
Collapse
|
218
|
Carbonell AM, Matthews BD, Dréau D, Foster M, Austin CE, Kercher KW, Sing RF, Heniford BT. The susceptibility of prosthetic biomaterials to infection. Surg Endosc 2004; 19:430-5. [PMID: 15580439 DOI: 10.1007/s00464-004-8810-4] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2004] [Accepted: 08/25/2004] [Indexed: 02/08/2023]
Abstract
BACKGROUND Despite the use of a sterile technique and the administration of prophylactic antibiotics during surgical procedures, mesh infection continues to complicate the use of biomaterials. The purpose of this study was to compare the susceptibility to infection of prosthetic biomaterials in a live-animal model. METHODS The following seven prosthetic mesh biomaterials were used in this study. Expanded polytetrafluoroethylene (ePTFE) with silver/chlorhexidine (DM+), ePTFE (DM), porcine intestinal submucosa (S), polypropylene (M), ePTFE/polypropylene (X), hyaluronate/carboxymethylcellulose/polypropylene (SM), and human acellular dermal matrix (A). Lewis rats (n = 108) underwent creation of a single ventral hernia; 105 of them were repaired with a different mesh (2-cm2 piece). Twelve pieces of each mesh were inoculated at the time of hernia repair with 10(8) Staphylococcus aureus (n = 84). Three pieces of each mesh were placed without bacterial inoculation (n = 21). In three animals, no mesh was placed; instead, the peritoneum of the hernia defect was inoculated (n = 3). After 5 days, the animals were killed and the mesh was explanted (peritoneum for the nonmesh control). The mesh was vortex-washed and incubated in tryptic soy broth. Bacterial counts were determined using serial dilutions and spot plates and quantified in colony-forming units (CFU) per square centimeter of mesh present in the vortex wash fluid (wash count) and the soy broth (broth count). Data are presented as the mean log(10), with analysis of variance (ANOVA) and Tukey's test used to determine significance (p < 0.05). RESULTS The DM+ material had no detectable live bacteria in the wash or broth counts in 10 of 12 tested samples (p = 0.05). Of the samples that showed bacterial growth, the peritoneum control group had a lower wash count than A (p = 0.05) and the lowest broth count of all the materials except for DM+ (p = 0.05). In addition, SM had a significantly lower wash count than A (p = 0.05), with no broth count difference. In regard to wash and broth counts, DM, M, X, SM, S, and A were no different (p = NS). CONCLUSIONS The DM+ material was the least susceptible to infection. Impregnation with silver/chlorhexidine killed the inoculated bacteria, preventing their proliferation on the mesh surface. Other than DM+, native peritoneal tissue appears to be the least susceptible to infection. Silver/chlorhexidine appears to be an effective bactericidal agent for use with mesh biomaterials.
Collapse
Affiliation(s)
- A M Carbonell
- Department of General Surgery, Carolinas Medical Center, 1000 Blythe Boulevard, MEB #601, Charlotte, NC 28203, USA
| | | | | | | | | | | | | | | |
Collapse
|
219
|
Alt V, Pfefferle HJ, Kreuter J, Stahl JP, Pavlidis T, Meyer C, Mockwitz J, Wenisch S, Schnettler R. Effect of glycerol-l-lactide coating polymer on bone ingrowth of bFGF-coated hydroxyapatite implants. J Control Release 2004; 99:103-11. [PMID: 15342184 DOI: 10.1016/j.jconrel.2004.06.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2004] [Accepted: 06/22/2004] [Indexed: 11/24/2022]
Abstract
Basic fibroblast growth factor (bFGF)-coated hydroxyapatite (HA) cylinders showed good bony incorporation in a previously conducted animal study. However, some cylinders exhibited focal inhomogeneous bone ingrowth. The purpose of the current study was to test whether glycerol-L-lactide polymer coating could improve release properties and bone incorporation of bFGF-coated HA implants. bFGF-coated HA cylinders with or without coating polymer were investigated for in vitro release of bFGF by an immuno-ligand-assay and also for bone ingrowth in miniature pigs after 42 and 84 days. Release from bFGF polymer composites was lower for the first 3 days compared to the other group but was more homogenous and detectable amounts were still found after 20 days. There was significant delay in bone ingrowth of the polymer implants in which even after 84 days bone ingrowth was not completed, whereas in the other group incorporation after 42 days occurred. Detailed histology revealed filling of the HA pores with the polymer, making ingrowth of the surrounding host bone impossible. Only after 84 days starting resorption of the polymer accompanied by bone ingrowth was found. The current study showed that glycerol-L-lactide is not suitable for coating of HA implants due to polymer induced "locking" of HA pores.
Collapse
Affiliation(s)
- Volker Alt
- Department of Trauma Surgery, Justus-Liebig-University Giessen, Rudolf-Buchheim-Str. 7, 35385 Giessen, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|