201
|
Panaich SS, Badheka AO, Arora S, Patel NJ, Thakkar B, Patel N, Singh V, Chothani A, Deshmukh A, Agnihotri K, Jhamnani S, Lahewala S, Manvar S, Panchal V, Patel A, Patel N, Bhatt P, Savani C, Patel J, Savani GT, Solanki S, Patel S, Kaki A, Mohamad T, Elder M, Kondur A, Cleman M, Forrest JK, Schreiber T, Grines C. Variability in utilization of drug eluting stents in United States: Insights from nationwide inpatient sample. Catheter Cardiovasc Interv 2015; 87:23-33. [DOI: 10.1002/ccd.25977] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 03/25/2015] [Accepted: 04/04/2015] [Indexed: 11/10/2022]
Affiliation(s)
| | - Apurva O. Badheka
- Department of Cardiology, Yale School of Medicine; New Haven Connecticut
| | - Shilpkumar Arora
- Department of Internal Medicine, Mount Sinai St. Luke's Roosevelt Hospital; New York New York
| | - Nileshkumar J. Patel
- Department of Internal Medicine; Staten Island University Hospital; Staten Island New York
| | - Badal Thakkar
- Department of Internal Medicine; Tulane School of Public Health & Tropical Medicine; New Orleans Louisiana
| | - Nilay Patel
- Department of Internal Medicine; Saint Peter's University Hospital; New Brunswick New Jersey
| | - Vikas Singh
- Department of Cardiology; University of Miami Miller School of Medicine; Miami Florida
| | - Ankit Chothani
- Department of Internal Medicine; MedStar Washington Hospital Center; Washington District of Columbia
| | | | - Kanishk Agnihotri
- Department of Internal Medicine; Saint Peter's University Hospital; New Brunswick New Jersey
| | - Sunny Jhamnani
- Department of Cardiology, Yale School of Medicine; New Haven Connecticut
| | - Sopan Lahewala
- Department of Internal Medicine; Icahn School of Medicine at Mount Sinai; New York New York
| | | | - Vinaykumar Panchal
- Department of Internal Medicine; Tulane School of Public Health & Tropical Medicine; New Orleans Louisiana
| | - Achint Patel
- Department of Internal Medicine; Icahn School of Medicine at Mount Sinai; New York New York
| | - Neil Patel
- Department of Internal Medicine; Icahn School of Medicine at Mount Sinai; New York New York
| | - Parth Bhatt
- Department of Internal Medicine; Tulane School of Public Health & Tropical Medicine; New Orleans Louisiana
| | - Chirag Savani
- Department of Internal Medicine; New York Medical College; Valhalla New York
| | - Jay Patel
- Detroit Medical Center; Detroit Michigan
| | | | - Shantanu Solanki
- Department of Internal Medicine; Icahn School of Medicine at Mount Sinai; New York New York
| | - Samir Patel
- Department of Internal Medicine, Western Reserve Health System; Youngstown Ohio
| | - Amir Kaki
- Detroit Medical Center; Detroit Michigan
| | | | | | | | - Michael Cleman
- Department of Cardiology, Yale School of Medicine; New Haven Connecticut
| | - John K. Forrest
- Department of Cardiology, Yale School of Medicine; New Haven Connecticut
| | | | | |
Collapse
|
202
|
Chow CL, Scott P, Farouque O, Clark DJ. Drug-coated balloons: a novel advance in the percutaneous treatment of coronary and peripheral artery disease. Interv Cardiol 2015. [DOI: 10.2217/ica.15.4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
203
|
Wijns W, Vrolix M, Verheye S, Schoors D, Slagboom T, Gosselink M, Benit E, Donohoe D, Knape C, Attizzani GF, Lansky AJ, Ormiston J. Randomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial. EUROINTERVENTION 2015; 10:1383-90. [DOI: 10.4244/eijy14m05_03] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
204
|
Palmerini T, Sangiorgi D, Valgimigli M, Biondi-Zoccai G, Feres F, Abizaid A, Costa RA, Hong MK, Kim BK, Jang Y, Kim HS, Park KW, Mariani A, Della Riva D, Genereux P, Leon MB, Bhatt DL, Bendetto U, Rapezzi C, Stone GW. Short- Versus Long-Term Dual Antiplatelet Therapy After Drug-Eluting Stent Implantation. J Am Coll Cardiol 2015; 65:1092-102. [PMID: 25790880 DOI: 10.1016/j.jacc.2014.12.046] [Citation(s) in RCA: 141] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Accepted: 12/18/2014] [Indexed: 02/05/2023]
Affiliation(s)
- Tullio Palmerini
- Dipartimento Cardio-Toraco-Vascolare, University of Bologna, Bologna, Italy
| | - Diego Sangiorgi
- Dipartimento Cardio-Toraco-Vascolare, University of Bologna, Bologna, Italy
| | - Marco Valgimigli
- Erasmus Medical Center, Thoraxcenter, Rotterdam, the Netherlands
| | - Giuseppe Biondi-Zoccai
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; VCU Pauley Heart Center, Virginia Commonwealth University, Richmond, Virginia
| | - Fausto Feres
- Istituto Dante Pazzanese de Cardiologia, Sao Paulo, Brazil
| | | | | | - Myeong-Ki Hong
- Severance Cardiovascular Hospital and Science Institute, Yonsei University College of Medicine, Seoul, South Korea
| | - Byeong-Keuk Kim
- Severance Cardiovascular Hospital and Science Institute, Yonsei University College of Medicine, Seoul, South Korea
| | - Yangsoo Jang
- Severance Cardiovascular Hospital and Science Institute, Yonsei University College of Medicine, Seoul, South Korea
| | - Hyo-Soo Kim
- Department of Internal Medicine, Seoul National University Hospital, Seoul, South Korea
| | - Kyung Woo Park
- Department of Internal Medicine, Seoul National University Hospital, Seoul, South Korea
| | - Andrea Mariani
- Dipartimento Cardio-Toraco-Vascolare, University of Bologna, Bologna, Italy
| | - Diego Della Riva
- Dipartimento Cardio-Toraco-Vascolare, University of Bologna, Bologna, Italy
| | - Philippe Genereux
- Columbia University Medical Center/New York-Presbyterian Hospital and the Cardiovascular Research Foundation, New York, New York
| | - Martin B Leon
- Columbia University Medical Center/New York-Presbyterian Hospital and the Cardiovascular Research Foundation, New York, New York
| | - Deepak L Bhatt
- Brigham and Women's Hospital Heart and Vascular Center and Harvard Medical School, Boston, Massachusetts
| | | | - Claudio Rapezzi
- Dipartimento Cardio-Toraco-Vascolare, University of Bologna, Bologna, Italy
| | - Gregg W Stone
- Columbia University Medical Center/New York-Presbyterian Hospital and the Cardiovascular Research Foundation, New York, New York.
| |
Collapse
|
205
|
Gao Z, Zhang R, Xu B, Yang Y, Ma C, Li H, Chen S, Han Y, Yuan Z, Lansky AJ, Guan C, Leon MB, Gao R. Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent for the treatment of de novo coronary lesions: two-year results from a prospective patient-level pooled analysis of TARGET trials. Catheter Cardiovasc Interv 2015; 85 Suppl 1:734-43. [PMID: 25678281 DOI: 10.1002/ccd.25861] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Accepted: 01/08/2015] [Indexed: 11/07/2022]
Abstract
OBJECTIVES We aimed to evaluate the safety and effectiveness of the novel abluminal groove-filled biodegradable polymer-coated sirolimus-eluting FIREHAWK stent (MicroPort Medical, Shanghai, China) in a large cohort of patients. BACKGROUND Trials on the FIREHAWK stent allowing targeted sirolimus release were not individually powered to reliably estimate low-frequency safety endpoints such as stent thrombosis (ST) or to examine long-term safety and efficacy. Additionally, the China Food and Drug Administration requires an objective performance criterion (OPC) study for new drug-eluting stents. METHODS The primary endpoint, target lesion failure (TLF), was defined as the composite of cardiac death, target vessel myocardial infarction (MI), or clinically indicated target lesion revascularization at 12 months. Patient-level data from 1,007 patients with de novo native coronary lesions exclusively treated with the FIREHAWK stent in the TARGET serial studies (I and II) were prospectively collected, pooled and analyzed throughout a 2-year follow-up. RESULTS The 12-month rate of TLF in 1,003 patients (follow-up rate, 99.6%) was 3.9% (upper 95% confidence interval (CI): 5.3%), which was significantly lower than the performance goal of 9.0% (P < 0.0001). The 24-month rates of TLF, PoCE (a composite of all-cause death, all MI, or any revascularization), and ARC definite or probable ST were 4.6%, 7.8% and 0.1%, respectively. In subgroup analysis, long lesion (≥ 30 mm) was an independent predictor of TLF within 2 years (hazard ratio [95%CI]: 2.44 [1.32, 4.53], P < 0.01). CONCLUSIONS This pooled, patient-level analysis indicates that the FIREHAWK stent exhibits a promising 2-year efficacy and safety profile.
Collapse
Affiliation(s)
- Zhan Gao
- Department of Cardiology, Fu Wai Hospital, National Center for Cardiovascular Diseases, Beijing, China
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
206
|
Wiemer M, Danzi GB, West N, Voudris V, Koning R, Hoffmann S, Lombardi M, Mauri J, Babic R, Witherow F. Drug-eluting stents with biodegradable polymer for the treatment of patients with diabetes mellitus: clinical outcome at 2 years in a large population of patients. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2015; 8:153-60. [PMID: 25737640 PMCID: PMC4342370 DOI: 10.2147/mder.s67399] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective This study investigates the safety and efficacy of a third-generation drug-eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus (DM). Clinical trial registration ISRCTN81649913. Background Percutaneous coronary interventions in patients with DM are associated with a higher incidence of death, restenosis, and stent thrombosis as compared to non-diabetic patients. The use of a DES has been shown to improve outcomes in diabetic patients. Methods Out of 3,067 patients, enrolled in 126 centers worldwide in the NOBORI 2 registry, 888 patients suffered from DM, 213 of them (14%) being insulin-dependent DM (IDDM). Two years’ follow-up has been completed in this study. Results At 1- and 2-year follow-up, 97% and 95% of the patients, respectively, were available. The reported target lesion failure (TLF) rates at 1- and 2-year follow-up were 6.0% and 7.2% in the DM group, respectively, and 3.0% and 4.2% in the non-DM group, respectively (P<0.001 for both years). Inside the DM group, the TLF rates of 9.9% and 11.7% at the 1- and 2-year follow-ups, respectively, in patients with IDDM were significantly higher than the TLF rates of 4.7% and 5.8%, respectively, in the non-IDDM subgroup (P<0.01 for both years). The rate of stent thrombosis at the 2-year follow-up was 1.0% in the DM group and 0.7% in non-DM patients. There were no cases of late, or very late stent thrombosis in IDDM patients. Conclusion The Nobori DES performed well in patients with DM. As expected, patients with DM, particularly those with IDDM, had worse outcomes. However, the absence of late, and very late stent thrombosis in IDDM patients merits further investigation, as this finding might have significant clinical value.
Collapse
Affiliation(s)
- Marcus Wiemer
- Department of Cardiology, Heart and Diabetes Center North Rhine-Westphalia, Ruhr University Bochum, Bad Oeynhausen, Germany
| | | | | | | | | | | | | | - Josepa Mauri
- Hospital Universitari Germans Trias i Pujol, Badalona, Spain
| | - Rade Babic
- Institute for Cardiovascular Diseases Dedinje, Belgrade, Serbia
| | | |
Collapse
|
207
|
Dual antiplatelet therapy in patients with a long coronary artery lesion over 30 mm: Determinants and impact on prognosis. Arch Cardiovasc Dis 2015; 108:235-43. [PMID: 25682548 DOI: 10.1016/j.acvd.2014.11.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2014] [Revised: 10/08/2014] [Accepted: 11/27/2014] [Indexed: 11/22/2022]
Abstract
BACKGROUND The ideal duration of dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) is under debate. Lesion length is a well-recognized predictor of PCI complexity and long-term outcome. AIM To evaluate the determinants and impact on outcome of long-term DAPT in a retrospective cohort of patients treated for a long coronary lesion. METHODS Patients (n=460) who underwent PCI for a long lesion (>30 mm) were divided into two groups according to antiplatelet regimen at 1 year: patients who stopped DAPT before 1 year (single antiplatelet therapy group; n=168) and patients who continued DAPT for longer than 1 year (n=292). RESULTS Mean lesion length was 35.7±7.1 mm. The proportion of patients who continued DAPT after 1 year was 63.5%. The main determinants of long-term DAPT were initial presentation as myocardial infarction and implantation of a drug-eluting stent. Median follow-up was 37.4 (23-51) months after the 1-year period following the index PCI. Long-term DAPT was highly associated with a lower risk of all-cause and cardiovascular mortality by multivariable analysis and after adjustment for other predictors: hazard ratios 0.11 (95% confidence interval 0.03-0.32) and 0.15 (95% confidence interval 0.04-0.62), respectively. No increase in major bleeding was noted. CONCLUSION In a contemporary practice, nearly two-thirds of patients who undergo PCI for a long lesion are treated with DAPT for several years. Our results suggest that long-term DAPT is beneficial in this subset of patients identified as being at high risk.
Collapse
|
208
|
Kang HJ. Can improvements in our physiological understanding yield information on the utility of endothelial progenitor cell capture stents? Korean J Intern Med 2015; 30:27-8. [PMID: 25589831 PMCID: PMC4293559 DOI: 10.3904/kjim.2015.30.1.27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 12/04/2014] [Indexed: 11/27/2022] Open
Affiliation(s)
- Hyun-Jae Kang
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|
209
|
Gogas BD. Bioresorbable scaffolds for percutaneous coronary interventions. Glob Cardiol Sci Pract 2014; 2014:409-27. [PMID: 25780795 PMCID: PMC4355515 DOI: 10.5339/gcsp.2014.55] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2014] [Accepted: 12/11/2014] [Indexed: 12/23/2022] Open
Abstract
Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease remains a precipitating factor for sustained local inflammation, in-stent neo-atherosclerosis and impaired vasomotor function increasing the risk for late complications attributed to late or very late stent thrombosis and late target lesion revascularization (TLR) (late catch-up). The quest for optimal coronary stenting continues by further innovations in stent design and by using biocompatible materials other than cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding, local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics have been recently developed. These devices have been utilized in selected clinical applications so far providing preliminary evidence of safety showing comparable performance with current generation drug-eluting stents (DES). Herein we provide a comprehensive overview of the current status of these technologies, we elaborate on the potential benefits of transient coronary scaffolds over permanent stents in the context of vascular reparation therapy, and we further focus on the evolving challenges these devices have to overcome to compete with current generation DES. Condensed Abstract:: The quest for optimizing percutaneous coronary interventions continues by iterative innovations in device materials beyond cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding; local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics were recently developed. These devices have been utilized in selected clinical applications providing preliminary evidence of safety showing comparable intermediate term clinical outcomes with current generation drug-eluting stents.
Collapse
Affiliation(s)
- Bill D Gogas
- Andreas Gruentzig Cardiovascular Center, Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, GA
| |
Collapse
|
210
|
Stojkovic S, Neskovic AN, Mehmedbegovic Z, Kafedzic S, Ostojic M, Nedeljkovic M, Orlic D, Ilisic B, Ilic I, Aleksic A, Cerovic M, Nikolajevic I, Vlahovic-Stipac A, Stajic Z, Putnikovic B, Hamilos M. Reduced sirolimus systemic exposure and improved bioresorbable polymer properties: new allies for the treatment of patients with coronary artery disease. Fundam Clin Pharmacol 2014; 29:95-105. [PMID: 25223651 DOI: 10.1111/fcp.12092] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Revised: 04/29/2014] [Accepted: 08/25/2014] [Indexed: 11/29/2022]
Abstract
This prospective, first-in-man, open-label multicenter study sought to assess the pharmacokinetics of sirolimus after Ultimaster drug-eluting stent implantation (coated with sirolimus and bioabsorbable co-polymer) in patients with de novo coronary artery disease (the TCD-10023 PK study). The primary endpoint was sirolimus concentration in peripheral whole blood at 28 days after stent implantation. In addition, safety, tolerability, therapeutic outcome and vasomotor response after stent implantation were studied. Twenty patients were enrolled in the study. Blood samples for the measurements of sirolimus concentration were collected at eight time points during first 48 h, at 7 days and 28 days after stent implantation. Patients underwent 6-month angiographic and up to 12 months clinical follow-up. At 28 days, only two of 20 patients had sirolimus concentrations above lower limit of quantification (20.0 pg/mL). The highest sirolimus blood concentration was 105 pg/mL. The median maximum concentration was 36.8 pg/mL (range 22.9-41.5 pg/mL) for stent 3.0 × 15 mm and 87.2 pg/mL (range 60.0-105.0 pg/mL) for 3 × 28 mm stent. The median systemic exposure, as measured by the area under the time-concentration curve, was 8.3 ng h/mL (range 6.47-28.0 ng h/mL). At 6 months, endothelial function was well preserved, and up to 12 months, there were no signs of sirolimus toxicity nor any other safety concerns. Our results demonstrate that implantation of Ultimaster stent resulted in almost nondetectable sirolimus in blood after 28 days. These findings were translated into exceptional safety profile, without any sign of systemic toxicity.
Collapse
Affiliation(s)
- Sinisa Stojkovic
- Clinic for Cardiology, Clinical Center of Serbia, Faculty of Medicine, University of Belgrade, 8 Dr Subotica, Belgrade, Serbia
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
211
|
Valgimigli M, Sabaté M, Kaiser C, Brugaletta S, de la Torre Hernandez JM, Galatius S, Cequier A, Eberli F, de Belder A, Serruys PW, Ferrante G. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis. BMJ 2014; 349:g6427. [PMID: 25378023 PMCID: PMC4220288 DOI: 10.1136/bmj.g6427] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. DESIGN Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. DATA SOURCES AND STUDY SELECTION Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. RESULTS The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.
Collapse
Affiliation(s)
- Marco Valgimigli
- Thoraxcenter, Erasmus Medical Center, 3015 CE Rotterdam, Netherlands
| | - Manel Sabaté
- University Hospital Clinic, IDIBAPS, Cardiology Department, 08036 Barcelona, Spain
| | | | - Salvatore Brugaletta
- University Hospital Clinic, IDIBAPS, Cardiology Department, 08036 Barcelona, Spain
| | | | | | - Angel Cequier
- University Hospital of Bellvitge, 08907 Barcelona, Spain
| | | | - Adam de Belder
- Brighton and Sussex University Hospitals NHS Trust, Brighton BN1 6AG, UK
| | - Patrick W Serruys
- Thoraxcenter, Erasmus Medical Center, 3015 CE Rotterdam, Netherlands
| | - Giuseppe Ferrante
- Interventional Cardiology, Humanitas Clinical and Research Institute IRCCS, 20089 Rozzano, Milan, Italy
| |
Collapse
|
212
|
Abstract
The duration of dual antiplatelet therapy (DAPT) after percutaneous coronary interventions (PCI) depends on the type of intervention and the clinical situation of the patient. After angioplasty alone (plain old balloon angioplasty, POBA) DAPT is not yet established but does, however, make sense to continue for 4 weeks. The duration of DAPT after placement of bare metal stents (BMS) is 4 weeks, after drug-eluting stents (DES) 6 months, after bioresorbable vascular scaffold (BVS) systems 6-12 months and after drug-coated balloon catheters (DCB) without a new implant 4 weeks.
Collapse
Affiliation(s)
- B Scheller
- Klinik für Innere Medizin III - Klinische und Experimentelle Interventionelle Kardiologie , Universitätsklinikum des Saarlandes, Gebäude 40, Kirrberger Str., 66421, Homburg/Saar, Deutschland,
| |
Collapse
|
213
|
Abstract
Though coronary bypass graft surgery (CABG) has traditionally been the cornerstone of therapy in patients with unprotected left main coronary artery (ULMCA) disease, recent evidence supports the use of percutaneous coronary intervention in appropriate patients. Indeed in patients with ULMCA disease, drug-eluting stents (DES) have shown similar incidence of hard end points, fewer periprocedural complications and lower stroke rates compared with CABG, though at the cost of increased revascularization with time. Furthermore, the availability of newer efficacious and safer DES as well as improvements in diagnostic tools, percutaneous techniques and, importantly, a better patient selection, allowed percutaneous coronary intervention a viable alternative to CABG of left main-patients with low disease complexity; however, even in this interventional era characterized by efficacious DES, patients with ULMCA disease remain a challenging high-risk population where outcomes strongly depend on clinical characteristics, anatomical disease complexity and extension and operator's experience. This review summarizes the role of DES in ULMCA disease patients.
Collapse
Affiliation(s)
- Chiara Bernelli
- Interventional Cardiology Unit, Azienda Ospedaliera Papa Giovanni XXIII, Piazza OMS 1, Bergamo, Italy
| |
Collapse
|
214
|
Ughi GJ, Verjans J, Fard AM, Wang H, Osborn E, Hara T, Mauskapf A, Jaffer FA, Tearney GJ. Dual modality intravascular optical coherence tomography (OCT) and near-infrared fluorescence (NIRF) imaging: a fully automated algorithm for the distance-calibration of NIRF signal intensity for quantitative molecular imaging. Int J Cardiovasc Imaging 2014; 31:259-68. [PMID: 25341407 DOI: 10.1007/s10554-014-0556-z] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Accepted: 10/18/2014] [Indexed: 01/09/2023]
Abstract
Intravascular optical coherence tomography (IVOCT) is a well-established method for the high-resolution investigation of atherosclerosis in vivo. Intravascular near-infrared fluorescence (NIRF) imaging is a novel technique for the assessment of molecular processes associated with coronary artery disease. Integration of NIRF and IVOCT technology in a single catheter provides the capability to simultaneously obtain co-localized anatomical and molecular information from the artery wall. Since NIRF signal intensity attenuates as a function of imaging catheter distance to the vessel wall, the generation of quantitative NIRF data requires an accurate measurement of the vessel wall in IVOCT images. Given that dual modality, intravascular OCT-NIRF systems acquire data at a very high frame-rate (>100 frames/s), a high number of images per pullback need to be analyzed, making manual processing of OCT-NIRF data extremely time consuming. To overcome this limitation, we developed an algorithm for the automatic distance-correction of dual-modality OCT-NIRF images. We validated this method by comparing automatic to manual segmentation results in 180 in vivo images from six New Zealand White rabbit atherosclerotic after indocyanine-green injection. A high Dice similarity coefficient was found (0.97 ± 0.03) together with an average individual A-line error of 22 µm (i.e., approximately twice the axial resolution of IVOCT) and a processing time of 44 ms per image. In a similar manner, the algorithm was validated using 120 IVOCT clinical images from eight different in vivo pullbacks in human coronary arteries. The results suggest that the proposed algorithm enables fully automatic visualization of dual modality OCT-NIRF pullbacks, and provides an accurate and efficient calibration of NIRF data for quantification of the molecular agent in the atherosclerotic vessel wall.
Collapse
Affiliation(s)
- Giovanni J Ughi
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA,
| | | | | | | | | | | | | | | | | |
Collapse
|
215
|
Foin N, Lee RD, Torii R, Guitierrez-Chico JL, Mattesini A, Nijjer S, Sen S, Petraco R, Davies JE, Di Mario C, Joner M, Virmani R, Wong P. Impact of stent strut design in metallic stents and biodegradable scaffolds. Int J Cardiol 2014; 177:800-8. [PMID: 25449502 DOI: 10.1016/j.ijcard.2014.09.143] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 08/25/2014] [Accepted: 09/27/2014] [Indexed: 10/24/2022]
Abstract
Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients.
Collapse
Affiliation(s)
| | | | - Ryo Torii
- Department of Mechanical Engineering, University College London, UK
| | | | - Alessio Mattesini
- Biomedical Research Unit, Royal Brompton & Harefield NHS Trust, London, UK
| | - Sukhjinder Nijjer
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Sayan Sen
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Ricardo Petraco
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Justin E Davies
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Carlo Di Mario
- Biomedical Research Unit, Royal Brompton & Harefield NHS Trust, London, UK
| | | | | | | |
Collapse
|
216
|
Nakazawa G, Shinke T, Ijichi T, Matsumoto D, Otake H, Torii S, Hiranuma N, Ohsue T, Otsuka F, Shite J, Hirata KI, Ikari Y. Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model. EUROINTERVENTION 2014; 10:717-23. [DOI: 10.4244/eijv10i6a124] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
217
|
O'Mahony C, Rothman M, Mathur A. A clinical update on the use of resolute stents with dual anti-platelet therapy interruption. Interv Cardiol 2014. [DOI: 10.2217/ica.14.47] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
218
|
Lemesle G, Lamblin N, Meurice T, Tricot O, Lallemant R, Nugue O, Delomez M, Equine O, Tondeux S, Bauters C. Dual antiplatelet therapy in patients with stable coronary artery disease in modern practice: prevalence, correlates, and impact on prognosis (from the Suivi d'une cohorte de patients COROnariens stables en region NORd-Pas-de-Calais study). Am Heart J 2014; 168:479-86. [PMID: 25262257 DOI: 10.1016/j.ahj.2014.06.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Accepted: 06/15/2014] [Indexed: 11/26/2022]
Abstract
BACKGROUND The prevalence and correlates of dual-antiplatelet therapy (DAPT) use in stable coronary artery disease (CAD) are unknown. In addition, whether prolonged DAPT may impact prognosis in stable CAD has not been studied in real-life conditions. METHODS We studied 3,691 patients included in a prospective registry on stable CAD. The patients were divided in 2 groups according to their antiplatelet therapy regimen at inclusion: patients treated with DAPT were compared with those treated with single-antiplatelet therapy (SAPT). The primary outcome was a composite of cardiovascular death, myocardial infarction, or stroke. RESULTS Altogether, 868 (24%) patients received DAPT. Factors positively associated with DAPT use were persistent angina at inclusion, body mass index, myocardial infarction since 1 to 3 years, myocardial revascularization since 1 to 3 years, multivessel CAD, prior drug-eluting stent implantation, and prior aortic or peripheral intervention. Factors negatively associated with DAPT use were age, prior coronary bypass, and left ventricular ejection fraction. The rate of the primary outcome at 2 years was similar whether patients were treated with SAPT (4.6%) or DAPT (5.5%) (P = .301). Similar rates were also observed after propensity score matching: 5.7% when treated with SAPT versus 5.5% when treated with DAPT (P = .886). The rate of bleeding was similar between groups. CONCLUSIONS Our study shows that a significant proportion of stable CAD patients are treated with DAPT in modern practice. Several correlates of DAPT were identified. Although no increase in bleeding was observed, our results do not support the prescription of prolonged DAPT.
Collapse
|
219
|
Otsuki S, Sabaté M. Drug-eluting stents and acute myocardial infarction: A lethal combination or friends? World J Cardiol 2014; 6:929-938. [PMID: 25276295 PMCID: PMC4176803 DOI: 10.4330/wjc.v6.i9.929] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Revised: 03/12/2014] [Accepted: 07/17/2014] [Indexed: 02/06/2023] Open
Abstract
Primary percutaneous coronary intervention is the preferred reperfusion strategy for patients presenting with ST-segment elevation myocardial infarction (STEMI). First generation drug-eluting stents (DES), (sirolimus drug-eluting stents and paclitaxel drug-eluting stents), reduce the risk of restenosis and target vessel revascularization compared to bare metal stents. However, stent thrombosis emerged as a major safety concern with first generation DES. In response to these safety issues, second generation DES were developed with different drugs, improved stent platforms and more biocompatible durable or bioabsorbable polymeric coating. This article presents an overview of safety and efficacy of the first and second generation DES in STEMI.
Collapse
|
220
|
Loh JP, Barbash IM, Waksman R. The current status of drug-coated balloons in percutaneous coronary and peripheral interventions. EUROINTERVENTION 2014; 9:979-88. [PMID: 24384294 DOI: 10.4244/eijv9i8a164] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Through continued innovation, percutaneous treatment of coronary and peripheral stenoses has evolved rapidly since balloon angioplasty was first introduced three decades ago. Significant advances were made with the introduction of bare metal stents and subsequently drug-eluting stents, which expanded the possibility of successful revascularisation in complicated lesions. Despite these advantages, efforts are still ongoing to improve patient outcomes further. In recent years, drug-coated balloons have emerged as an exciting technology developed to overcome the limitations faced by drug-eluting stents, such as stent thrombosis and dependency on prolonged dual antiplatelet therapy, and may prove efficacious in complex subsets such as small vessels and diffuse lesions where stent results are suboptimal. Several drug-coated balloons developed for coronary and peripheral applications were evaluated recently in preclinical and clinical studies with encouraging results. Drug-coated balloons have proven effective in treating in-stent restenosis; however, there is accumulating evidence on their utility in other clinical scenarios. We present a timely review of the mechanisms of action, key preclinical studies, emerging clinical indications, current clinical trial results, and future perspectives of this novel drug-coated balloon technology as it seeks to establish its role in percutaneous intervention.
Collapse
Affiliation(s)
- Joshua P Loh
- Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | | | | |
Collapse
|
221
|
Polymer-free drug-eluting stent in unselected patient population: A single center experience. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2014; 15:350-3. [DOI: 10.1016/j.carrev.2014.08.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Revised: 08/24/2014] [Accepted: 08/29/2014] [Indexed: 11/18/2022]
|
222
|
Costa JR, Oliveira BA, Abizaid A, Costa R, Perin M, Abizaid A, Chamié D, Fernando Tanajura L, Sousa A, Sousa JEM. Clinical, angiographic, and intravascular ultrasound results of the VestSaync II trial. Catheter Cardiovasc Interv 2014; 84:1073-9. [DOI: 10.1002/ccd.24909] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Revised: 02/11/2013] [Accepted: 02/26/2013] [Indexed: 11/10/2022]
Affiliation(s)
- J. Ribamar Costa
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - Breno A. Oliveira
- Department of Invasive Cardiology; Hospital Santa Marcelina; São Paulo Brasil
| | - Alexandre Abizaid
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - Ricardo Costa
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - Marco Perin
- Department of Invasive Cardiology; Hospital Santa Marcelina; São Paulo Brasil
| | - Andréa Abizaid
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - Daniel Chamié
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - Luiz Fernando Tanajura
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - Amanda Sousa
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| | - J. Eduardo M.R. Sousa
- Department of Invasive Cardiology; Instituto Dante Pazzanese de Cardiologia; São Paulo Brasil
| |
Collapse
|
223
|
Navarese EP, Kowalewski M, Kandzari D, Lansky A, Górny B, Kołtowski L, Waksman R, Berti S, Musumeci G, Limbruno U, van der Schaaf RJ, Kelm M, Kubica J, Suryapranata H. First-generation versus second-generation drug-eluting stents in current clinical practice: updated evidence from a comprehensive meta-analysis of randomised clinical trials comprising 31 379 patients. Open Heart 2014; 1:e000064. [PMID: 25332803 PMCID: PMC4189321 DOI: 10.1136/openhrt-2014-000064] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 05/15/2014] [Accepted: 07/15/2014] [Indexed: 12/14/2022] Open
Abstract
Background First-generation drug-eluting stents (DES) have become the most widely used devices worldwide for management of coronary artery disease. As remote follow-up data were becoming available, concerns emerged in regard to their long-term safety. Second-generation DES were designed to overcome safety issues, but the results of randomised clinical trials remain conflicting. Methods We compared the safety and efficacy of first-generation versus second-generation Food and Drug Administration approved DES; the following devices were included: first-generation sirolimus-eluting stent (SES) and paclitaxel-eluting stents (PES); second-generation everolimus-eluting stent (EES), zotarolimus-eluting stent Endeavor and ZES-Resolute (ZES-R). Prespecified safety end points comprised ≤1 and >1 year: overall and cardiac mortality, myocardial infarction (MI), definite/definite or probable ST; efficacy end points were target lesion revascularisation and target vessel revascularisation. Composite end points were analysed as well. Results 33 randomised controlled trials involving 31 379 patients with stable coronary artery disease or acute coronary syndrome undergoing DES implantation were retrieved. No differences in mortality among devices were found. In the overall class comparison, second-generation DES were associated with a 22% reduction of odds of MI at short-term OR 0.77 (95% CI 0.68 to 0.89) p=0.0002; EES reduced the odds of definite-probable ST compared with PES: OR 0.33 (95% CI 0.15 to 0.73) p=0.006; First-generation SES along with second-generation EES and ZES-R showed similar efficacy in decreasing the odds of repeat revascularisation. Conclusions Second-generation EES and ZES-R offer similar levels of efficacy compared with first-generation SES, but are more effective than PES; however, only second-generation EES significantly reduced the incidence of MI and ST, and therefore should be perceived as the safest DES to date.
Collapse
Affiliation(s)
- Eliano Pio Navarese
- Invasive Cardiology, National Research Council Institute of Clinical Physiology (CNR-IFC), Pisa , Italy ; Department of Internal Medicine, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich-Heine-University, Düsseldorf , Germany ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Mariusz Kowalewski
- 10th Military Research Hospital and Polyclinic, Bydgoszcz , Poland ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - David Kandzari
- Piedmont Heart Institute, Atlanta, Georgia , USA ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Alexandra Lansky
- Department of Cardiology, Yale Medical School, New Haven, Connecticut , USA
| | - Bartosz Górny
- 10th Military Research Hospital and Polyclinic, Bydgoszcz , Poland ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Lukasz Kołtowski
- 1st Department of Cardiology, Teaching Hospital, Medical University of Warsaw, Warsaw , Poland ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Ron Waksman
- Division of Cardiology, MedStar Washington Hospital Center, Washington DC , USA
| | - Sergio Berti
- Invasive Cardiology, National Research Council Institute of Clinical Physiology (CNR-IFC), Pisa , Italy ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Giuseppe Musumeci
- Department of Cardiology, Ospedali Riuniti di Bergamo, Bergamo , Italy ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Ugo Limbruno
- Department of Cardiology, Ospedale della Misericordia, Grosseto , Italy
| | | | - Malte Kelm
- Department of Internal Medicine, Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich-Heine-University, Düsseldorf , Germany ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Jacek Kubica
- Department of Cardiology and Internal Medicine, Ludwik Rydygier Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz , Poland ; Systematic Investigation and Research on Interventions and Outcomes (SIRIO) MEDICINE Research Network
| | - Harry Suryapranata
- Department of Cardiology, Radboud University Nijmegen Medical Center, Nijmegen , The Netherlands
| |
Collapse
|
224
|
Saito S, Valdes-Chavarri M, Richardt G, Moreno R, Iniguez Romo A, Barbato E, Carrie D, Ando K, Merkely B, Kornowski R, Eltchaninoff H, James S, Wijns W. A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system: the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trial. Eur Heart J 2014; 35:2021-31. [PMID: 24847155 PMCID: PMC4200026 DOI: 10.1093/eurheartj/ehu210] [Citation(s) in RCA: 142] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2014] [Revised: 04/26/2014] [Accepted: 05/01/2014] [Indexed: 12/26/2022] Open
Abstract
AIM The aim of this study was to establish safety and efficacy of a new sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES). Sirolimus-eluting stent with bioresorbable polymer was compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in the frame of a CENTURY II clinical trial designed to make global clinical data compliant with regulatory requirements in Europe and Japan. METHODS AND RESULTS The CENTURY II is a prospective, multicentre, randomized (1 : 1), single blind, controlled, non-inferiority clinical trial conducted at 58 study sites in Japan, Europe, and Korea. A total of 1123 patients requiring a percutaneous coronary intervention (PCI) procedure, with implantation of drug-eluting stent (DES), were enrolled [total population (TP)]. Randomization of patients was stratified for the subset of patients matching requirements for DES in Japan (Cohort JR, n = 722). Baseline patient demographic and angiographic characteristics were similar in both study arms, with minimal differences between the TP and Cohort JR. The primary endpoint, freedom from target lesion failure (TLF) at 9 months-TLF [composite of cardiac death, target-vessel-related myocardial infarction (MI) and target lesion revascularization]-was 95.6% with BP-SES and 95.1% with PP-EES (Pnon-inferiority<0.0001). Composite of cardiac death and MI rate was 2.9 and 3.8% (P = 0.40) and target vessel revascularization was 4.5% with BP-SES and 4.2% with PP-EES (P = 0.77). The stent thrombosis rate was 0.9% in both arms. In Cohort JR, freedom from TLF was 95.9 and 94.6% (Pnon-inferiority < 0.0005) with BP-SES and PP-EES, respectively. CONCLUSION The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting stent at 9-month follow-up. STUDY REGISTRATION NUMBER UMIN000006940.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Kenji Ando
- Kokura Memorial Hospital, Fukuoka, Japan
| | - Bela Merkely
- Semmelweis University Hospital, Budapest, Hungary
| | | | | | | | - William Wijns
- Cardiovascular Centre Aalst, OLV Hospital, Aalst, Belgium Cardiovascular Centre Aalst, OLV Hospital, Moorselbaan 165, 9301 Aalst, Belgium
| |
Collapse
|
225
|
Gogas BD, McDaniel M, Samady H, King SB. Novel drug-eluting stents for coronary revascularization. Trends Cardiovasc Med 2014; 24:305-13. [PMID: 25240980 DOI: 10.1016/j.tcm.2014.07.004] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Revised: 07/29/2014] [Accepted: 07/29/2014] [Indexed: 11/19/2022]
Abstract
Over the past decades, there has been significant evolution in coronary stents used in percutaneous coronary intervention. The current novel drug-eluting stents available in the United States represent significant advancements compared to angioplasty, bare-metal stents, and the first generation of drug-eluting stents (DES). The Xience everolimus-eluting stents, Promus everolimus-eluting stents, and Resolute zotarolimus-eluting stents currently demonstrate the optimal balance of safety and efficacy. Endeavor zotarolimus-eluting stents have shorter drug-elution courses, and recent evidence suggests that 3 months of dual antiplatelet therapy appears safe, making Endeavor preferred when early discontinuation of dual antiplatelet therapy is warranted. Despite these advances in stent design, the permanent polymer and metallic stent remain in the vessel wall and may precipitate sustained inflammation, persistent vasomotor dysfunction, and in-stent neo-atherosclerosis. Bioresorbable platforms with biodegradable polymers have been developed to overcome the aforementioned limitations, and the outcomes of ongoing clinical trials are eagerly anticipated to determine if these novel stents will further improve clinical outcomes.
Collapse
Affiliation(s)
- Bill D Gogas
- Andreas Gruentzig Cardiovascular Center, Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, GA
| | - Michael McDaniel
- Andreas Gruentzig Cardiovascular Center, Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, GA
| | - Habib Samady
- Andreas Gruentzig Cardiovascular Center, Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, GA
| | - Spencer B King
- Andreas Gruentzig Cardiovascular Center, Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, GA.
| |
Collapse
|
226
|
Aytürk M, Sunman H, Yeter E. A persisting dilemma for triple antithrombotic therapy: are we close to finding the correct answer? J Am Coll Cardiol 2014; 64:231. [PMID: 24509279 DOI: 10.1016/j.jacc.2013.10.089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2013] [Accepted: 10/07/2013] [Indexed: 11/28/2022]
|
227
|
Costopoulos C, Latib A, Naganuma T, Sticchi A, Figini F, Basavarajaiah S, Carlino M, Chieffo A, Montorfano M, Naim C, Kawaguchi M, Giannini F, Colombo A. The role of drug-eluting balloons alone or in combination with drug-eluting stents in the treatment of de novo diffuse coronary disease. JACC Cardiovasc Interv 2014; 6:1153-9. [PMID: 24262615 DOI: 10.1016/j.jcin.2013.07.005] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 06/07/2013] [Accepted: 07/03/2013] [Indexed: 11/18/2022]
Abstract
OBJECTIVES This study sought to investigate the role of drug-eluting balloons (DEB) alone or in combination with drug-eluting stents (DES) in the treatment of diffuse de novo coronary artery disease (CAD) (>25 mm). BACKGROUND The use of DEB in diffuse CAD, either alone or in combination with DES, offers an alternative to stenting alone. Data regarding DEB in this context are limited. METHODS We retrospectively evaluated all patients treated with DEB for diffuse CAD between June 2009 and October 2012. Endpoints analyzed were major adverse cardiac events, defined as all-cause death, myocardial infarction, and target vessel revascularization (TVR), as well as TVR and target lesion revascularization separately. Results were compared with those obtained from a cohort of patients with similar characteristics treated with DES alone. RESULTS A total of 69 patients (93 lesions) were treated with DEB ± DES, and 93 patients with DES alone (93 lesions). A high proportion of patients were diabetic (46.4% vs. 44.1%, p = 0.77). Of the DEB-treated lesions, 56.0% were treated with DEB alone, 7.4% with DEB and DES as bail out, and 36.6% with DES and DEB as part of a hybrid approach for very long disease. Outcome rates with DEB ± DES were comparable to those with DES alone at 2-year follow-up (major adverse cardiac events = 20.8% vs. 22.7%, p = 0.74; TVR = 14.8% vs. 11.5%, p = 0.44; target lesion revascularization = 9.6% vs. 9.3%, p = 0.84). CONCLUSIONS DEB may have a role in the treatment of diffuse de novo CAD, either alone in smaller vessels or in combination with DES in very long disease.
Collapse
Affiliation(s)
- Charis Costopoulos
- Interventional Cardiology Unit, San Raffaele Scientific Institute, Milan, Italy; Interventional Cardiology Unit, EMO-GVM Centro Cuore Columbus, Milan, Italy; Imperial College London, London, United Kingdom
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
228
|
Strauss BH, Shuvy M. Stent thrombosis following drug-eluting stents in STEMI: "Much ado about nothing?". J Am Coll Cardiol 2014; 64:25-7. [PMID: 24998124 DOI: 10.1016/j.jacc.2014.04.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Accepted: 04/27/2014] [Indexed: 11/30/2022]
Affiliation(s)
- Bradley H Strauss
- Schulich Heart Center, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Ontario, Canada.
| | - Mony Shuvy
- Schulich Heart Center, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
229
|
Bangalore S, Gupta N, Guo Y, Feit F. Trend in the use of drug eluting stents in the United States. Int J Cardiol 2014; 175:108-19. [DOI: 10.1016/j.ijcard.2014.04.269] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 04/22/2014] [Accepted: 04/30/2014] [Indexed: 11/28/2022]
|
230
|
Yin Y, Zhang Y, Zhao X. Safety and efficacy of biodegradable drug-eluting vs. bare metal stents: a meta-analysis from randomized trials. PLoS One 2014; 9:e99648. [PMID: 24945816 PMCID: PMC4063774 DOI: 10.1371/journal.pone.0099648] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Accepted: 05/18/2014] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Biodegradable polymeric coatings have been proposed as a promising strategy to enhance biocompatibility and improve the delayed healing in the vessel. However, the efficacy and safety of biodegradable polymer drug-eluting stents (BP-DES) vs. bare metal stents (BMS) are unknown. The aim of this study was to perform a meta-analysis of randomized controlled trials (RCTs) comparing the outcomes of BP-DES vs. BMS. METHODS AND RESULTS PubMed, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched for randomized clinical trials, until December 2013, that compared any of approved BP-DES and BMS. Efficacy endpoints were target-vessel revascularization (TVR), target-lesion revascularization (TLR) and in-stent late loss (ISLL). Safety endpoints were death, myocardial infarction (MI), definite stent thrombosis (DST). The meta-analysis included 7 RCTs with 2,409 patients. As compared with BMS, there was a significantly reduced TVR (OR [95% CI] = 0.37 [0.28-0.50]), ISLL (OR [95% CI] = -0.41 [-0.48-0.34]) and TLR (OR [95% CI] = 0.38 [0.27-0.52]) in BP-DES patients. However, there were no difference for safety outcomes between BP-DES and BMS. CONCLUSIONS BP-DES is more effective in reducing ISLL, TVR and TLR, as safe as standard BMS with regard to death, ST and MI. Further large RCTs with long-term follow-up are warranted to better define the relative merits of BP-DES.
Collapse
Affiliation(s)
- Yangguang Yin
- Cardiovascular Disease Research Center, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Yao Zhang
- The Evidence Based Medicine and Clinic Epidemiology Center, Third Military Medical University, Chongqing, China
| | - Xiaohui Zhao
- Cardiovascular Disease Research Center, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| |
Collapse
|
231
|
Palhais N, Arroyo D, Lehmann S, Togni M, Kaufmann U, Puricel SG, Stauffer JC, Goy JJ, Cook S. Ten-year clinical follow-up after sirolimus-eluting stent implantation. Am Heart J 2014; 167:893-9. [PMID: 24890540 DOI: 10.1016/j.ahj.2013.12.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2013] [Accepted: 12/25/2013] [Indexed: 11/17/2022]
Abstract
BACKGROUND Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. METHODS AND RESULTS We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. CONCLUSION Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease.
Collapse
Affiliation(s)
| | | | | | - Mario Togni
- University and Hospital, Fribourg, Switzerland
| | | | | | | | | | | |
Collapse
|
232
|
Hamilos M, Ribichini F, Ostojic MC, Ferrero V, Orlic D, Vassanelli C, Karanovic N, Sarno G, Cuisset T, Vardas PE, Wijns W. Coronary Vasomotion One Year after Drug-Eluting Stent Implantation: Comparison of Everolimus-Eluting and Paclitaxel-Eluting Coronary Stents. J Cardiovasc Transl Res 2014; 7:406-12. [DOI: 10.1007/s12265-014-9568-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2014] [Accepted: 04/14/2014] [Indexed: 10/25/2022]
|
233
|
Muramatsu T, Onuma Y, van Geuns RJ, Chevalier B, Patel TM, Seth A, Diletti R, García-García HM, Dorange CC, Veldhof S, Cheong WF, Ozaki Y, Whitbourn R, Bartorelli A, Stone GW, Abizaid A, Serruys PW. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials. JACC Cardiovasc Interv 2014; 7:482-93. [PMID: 24746650 DOI: 10.1016/j.jcin.2014.01.155] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 12/30/2013] [Accepted: 01/04/2014] [Indexed: 01/12/2023]
Abstract
OBJECTIVES The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). BACKGROUND Clinical outcomes of diabetic patients after BVS implantation have been unreported. METHODS This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. RESULTS The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). CONCLUSIONS In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and diabetic patients treated with EES at 1-year follow-up. (ABSORB Clinical Investigation, Cohort B; NCT00856856; ABSORB EXTEND Clinical Investigation; NCT01023789; Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT FIRST]; NCT00180453; A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT II]; NCT00180310; Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System [EECSS] [SPIRIT III]; NCT00180479; Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT IV Clinical Trial]; NCT00307047).
Collapse
Affiliation(s)
- Takashi Muramatsu
- Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands; Department of Cardiology, Fujita Health University Hospital, Toyoake, Japan
| | - Yoshinobu Onuma
- Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands
| | | | | | | | - Ashok Seth
- Fortis Escorts Heart Institute, New Delhi, India
| | - Roberto Diletti
- Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands
| | | | | | | | | | - Yukio Ozaki
- Department of Cardiology, Fujita Health University Hospital, Toyoake, Japan
| | - Robert Whitbourn
- Cardiovascular Research Center, St. Vincent's Hospital, Melbourne, Victoria, Australia
| | | | - Gregg W Stone
- Columbia University Medical Center/New York-Presbyterian Hospital and Cardiovascular Research Foundation, New York, New York
| | | | | |
Collapse
|
234
|
Takimura CK, Campos CAHM, Melo PHMC, Campos JC, Gutierrez PS, Borges TFC, Curado L, Morato SP, Laurindo FRM, Lemos Neto PA. Preclinical study of a biodegradable polymer-based stent with abluminal sirolimus release. Arq Bras Cardiol 2014; 102:432-40. [PMID: 24759951 PMCID: PMC4051445 DOI: 10.5935/abc.20140044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Accepted: 11/13/2013] [Indexed: 11/20/2022] Open
Abstract
Background Bioabsorbable polymer stents with drug elution only on the abluminal surface may
be safer than durable polymer drug-eluting stents. Objective To report the experimental findings with the InspironTM stent - a
bioabsorbable polymer-coated stent with sirolimus release from the abluminal
surface only, recently approved for clinical use. Methods 45 stents were implanted in the coronary arteries of 15 pigs. On day 28 after
implantation, angiographic, intracoronary ultrasonographic and histomorphological
data were collected. Five groups were analyzed: Group I (nine bare-metal stents);
Group II (nine coated with bioabsorbable polymer on the luminal and abluminal
surfaces); Group III (eight stents coated with bioabsorbable polymer on the
abluminal surface); Group IV (nine stents with bioabsorbable polymer and sirolimus
on the luminal and abluminal surfaces); and Group V (ten stents with bioabsorbable
polymer and sirolimus only on the abluminal surface). Results The following results were observed for Groups I, II, III, IV and V, respectively:
percentage stenosis of 29 ± 20; 36 ± 14; 33 ± 19; 22 ± 13 and 26 ± 15 (p = 0.443);
late lumen loss (in mm) of 1.02 ± 0.60; 1.24 ± 0.48; 1.11 ± 0.54; 0.72 ± 0.44 and
0.78 ± 0.39 (p = 0.253); neointimal area (in mm2) of 2.60 ± 1.99; 2.74
± 1.51; 2.74 ± 1.30; 1.30 ± 1.14 and 0.97 ± 0.84 (p = 0.001; Groups IV and V
versus Groups I, II and III); and percentage neointimal area of 35 ± 25; 38 ± 18;
39 ± 19; 19 ± 18 and 15 ± 12 (p = 0.001; Groups IV and V versus Groups I, II and
III). Injury and inflammation scores were low and with no differences between the
groups. Conclusion The InspironTM stent proved to be safe and was able to significantly
inhibit the neointimal hyperplasia observed on day 28 after implantation in
porcine coronary arteries.
Collapse
Affiliation(s)
- Celso Kiyochi Takimura
- Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil
| | - Carlos Augusto Homem M Campos
- Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil
| | | | - Julliana Carvalho Campos
- Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil
| | - Paulo Sampaio Gutierrez
- Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil
| | | | | | | | | | - Pedro Alves Lemos Neto
- Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil
| |
Collapse
|
235
|
Kwong JSW, Yu CM. Clinical outcomes of biodegradable polymer drug-eluting stents for percutaneous coronary intervention: an updated meta-analysis of randomized controlled trials. Clin Cardiol 2014; 37:440-53. [PMID: 24723467 DOI: 10.1002/clc.22285] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Revised: 03/11/2014] [Indexed: 01/25/2023] Open
Abstract
Biodegradable polymer drug-eluting stents (DES) are innovative concepts in the era of percutaneous coronary intervention. We systematically reviewed the latest randomized evidence on the efficacy and safety of biodegradable polymer DES as compared to durable polymer DES. MEDLINE, Embase, and the Cochrane database were searched in August 2013 for eligible randomized controlled trials (RCTs) comparing biodegradable polymer DES with durable polymer DES. Clinical outcomes of interest were mortality, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis. A total of 20 RCTs randomizing 20 021 participants were included, of whom 11 045 were allocated to biodegradable polymer DES and 8976 to durable polymer DES. Treatment of biodegradable polymer DES was not associated with a significant reduction of any of the clinical outcomes (all-cause mortality, odds ratio [OR]: 0.94, 95% confidence interval [CI]: 0.80 to 1.10, P = 0.42; cardiovascular mortality, OR: 0.97, 95% CI: 0.79 to 1.19, P = 0.74; MI, OR: 1.07, 95% CI: 0.91 to 1.26, P = 0.41; TLR, OR: 0.87, 95% CI: 0.69 to 1.08, P = 0.20; TVR, OR: 1.05, 95% CI: 0.85 to 1.28, P = 0.67; definite/probable stent thrombosis, OR: 0.80, 95% CI: 0.59 to 1.07, P = 0.14). Current randomized data indicate that clinical efficacy and safety profiles of biodegradable polymer DES are comparable to those of durable polymer DES. Findings from large-scale studies with rigorous methodology and long follow-up duration are needed.
Collapse
Affiliation(s)
- Joey S W Kwong
- Institute of Vascular Medicine, Li Ka Shing Institute of Health Sciences, S.H. Ho Cardiovascular Disease and Stroke Centre, Heart Education And Research Training (HEART) Centre, and Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong
| | | |
Collapse
|
236
|
Camenzind E, Boersma E, Wijns W, Mauri L, Rademaker-Havinga T, Ordoubadi FF, Suttorp MJ, Al Kurdi M, Steg PG. Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type. Eur Heart J 2014; 35:1932-48. [PMID: 24627416 DOI: 10.1093/eurheartj/ehu084] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
AIM To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). METHODS AND RESULTS Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). CONCLUSION A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957).
Collapse
Affiliation(s)
- Edoardo Camenzind
- University of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva, Switzerland
| | - Eric Boersma
- Erasmus Medical Center, Rotterdam, the Netherlands
| | | | - Laura Mauri
- Brigham and Women's Hospital, Boston, MA, USA
| | | | | | | | - Mohammad Al Kurdi
- Prince Salman Cardiac Center, King Fahd Medical City, Riyad, Saudi Arabia
| | - Ph Gabriel Steg
- Université Paris-Diderot, Sorbonne-Paris Cité, Paris, France INSERM U-698, Paris, France Département Hospitalo-Universitaire FIRE, Hôpital Bichat, Assistance Publique - Hôpitaux de Paris, Paris, France NHLI Imperial College, ICMS, Royal Brompton Hospital, London, UK
| | | |
Collapse
|
237
|
Jiménez JM, Prasad V, Yu MD, Kampmeyer CP, Kaakour AH, Wang PJ, Maloney SF, Wright N, Johnston I, Jiang YZ, Davies PF. Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression. J R Soc Interface 2014; 11:20131079. [PMID: 24554575 DOI: 10.1098/rsif.2013.1079] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Drug eluting stents are associated with late stent thrombosis (LST), delayed healing and prolonged exposure of stent struts to blood flow. Using macroscale disturbed and undisturbed fluid flow waveforms, we numerically and experimentally determined the effects of microscale model strut geometries upon the generation of prothrombotic conditions that are mediated by flow perturbations. Rectangular cross-sectional stent strut geometries of varying heights and corresponding streamlined versions were studied in the presence of disturbed and undisturbed bulk fluid flow. Numerical simulations and particle flow visualization experiments demonstrated that the interaction of bulk fluid flow and stent struts regulated the generation, size and dynamics of the peristrut flow recirculation zones. In the absence of endothelial cells, deposition of thrombin-generated fibrin occurred primarily in the recirculation zones. When endothelium was present, peristrut expression of anticoagulant thrombomodulin (TM) was dependent on strut height and geometry. Thinner and streamlined strut geometries reduced peristrut flow recirculation zones decreasing prothrombotic fibrin deposition and increasing endothelial anticoagulant TM expression. The studies define physical and functional consequences of macro- and microscale variables that relate to thrombogenicity associated with the most current stent designs, and particularly to LST.
Collapse
Affiliation(s)
- Juan M Jiménez
- Department of Pathology and Laboratory Medicine, University of Pennsylvania, , Philadelphia, PA 19104, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
238
|
Chen SC, Hsiao FY, Lee CM, Hsu WWY, Gau CS. Duration of dual antiplatelet therapy following percutaneous coronary intervention on re-hospitalization for acute coronary syndrome. BMC Cardiovasc Disord 2014; 14:21. [PMID: 24533683 PMCID: PMC3974105 DOI: 10.1186/1471-2261-14-21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 01/28/2014] [Indexed: 11/10/2022] Open
Abstract
Background The optimal duration of dual antiplatelet therapy after percutaneous coronary intervention (PCI) remains uncertain. The objective of this study was to examine the association between duration of dual antiplatelet therapy and re-hospitalization for acute coronary syndrome (ACS) in ACS patients who underwent PCI. Methods We identified 975 newly diagnosed ACS patients who underwent PCI between July, 2007 and June, 2009, at a medical center in Taiwan. Cox proportional hazard models were used to examine the association between duration of dual antiplatelet therapy (9 months, 12 months and 15 months) and risks of re-hospitalization for ACS. Results At a mean follow-up of 2.3 years, we found that use of clopidogrel for ≥ 12 months was associated with a decreased risk of re-hospitalization for ACS (adjusted HR 0.59, 95% CI 0.36-0.95; p = 0.03). However, use of clopidogrel for ≥ 15 months was not associated with a decreased risk of re-hospitalization for ACS (adjusted HR 0.57, 95% CI 0.29-1.13; p = 0.11). Similar results were found in patients who implanted drug-eluting stents (DES), for whom at least 12 months of clopidogrel therapy is especially critical. Conclusion The benefit of ≥ 12 months of clopidogrel use in reducing the risk of re-hospitalization for ACS was significant among ACS patients who underwent PCI and was especially critical for those who implanted DES.
Collapse
Affiliation(s)
| | - Fei-Yuan Hsiao
- Graduate Institute of Clinical Pharmacy, College of Medicine, National Taiwan University, 33, Linsen South Road, Taipei, Taiwan.
| | | | | | | |
Collapse
|
239
|
Silber S, Kirtane AJ, Belardi JA, Liu M, Brar S, Rothman M, Windecker S. Lack of association between dual antiplatelet therapy use and stent thrombosis between 1 and 12 months following resolute zotarolimus-eluting stent implantation. Eur Heart J 2014; 35:1949-56. [DOI: 10.1093/eurheartj/ehu026] [Citation(s) in RCA: 102] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
|
240
|
Shellock FG, Giangarra CJ. In vitro assessment of 3-T MRI issues for a bioabsorbable, coronary artery scaffold with metallic markers. Magn Reson Imaging 2014; 32:163-7. [DOI: 10.1016/j.mri.2013.10.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2013] [Revised: 07/22/2013] [Accepted: 10/10/2013] [Indexed: 10/26/2022]
|
241
|
Shin DH, Hong MK. Optimal duration of dual antiplatelet therapy after drug-eluting stent implantation. Expert Rev Cardiovasc Ther 2014. [DOI: 10.1586/erc.12.113] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
242
|
Garg S, Serruys P. Benefits of and safety concerns associated with drug-eluting coronary stents. Expert Rev Cardiovasc Ther 2014; 8:449-70. [DOI: 10.1586/erc.09.138] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
243
|
Giannini F, Naim C, Costopoulos C, Latib A, Colombo A. Drug-coated balloons in interventional cardiology. Expert Rev Cardiovasc Ther 2014; 11:1379-91. [DOI: 10.1586/14779072.2013.837758] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
244
|
Karjalainen PP, Ylitalo A, Airaksinen JKE, Nammas W. Titanium-nitride-oxide-coated Titan-2 bioactive coronary stent: a new horizon for coronary intervention. Expert Rev Med Devices 2014; 7:599-604. [DOI: 10.1586/erd.10.44] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
245
|
Rossini R, Musumeci G, Aprile A, Valsecchi O. Long-term outcomes in patients undergoing percutaneous coronary intervention with drug-eluting stents. Expert Rev Pharmacoecon Outcomes Res 2014; 10:49-61. [DOI: 10.1586/erp.10.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
246
|
Lambert ND, Applegate RJ. The comparative safety of bare-metal and drug-eluting intracoronary stents. Expert Rev Med Devices 2014; 7:611-24. [DOI: 10.1586/erd.10.39] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
247
|
Kandzari DE. Development and performance of the zotarolimus-eluting Endeavor®coronary stent. Expert Rev Med Devices 2014; 7:449-59. [DOI: 10.1586/erd.10.31] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
248
|
Valgimigli M, Tebaldi M, Borghesi M, Vranckx P, Campo G, Tumscitz C, Cangiano E, Minarelli M, Scalone A, Cavazza C, Marchesini J, Parrinello G. Two-Year Outcomes After First- or Second-Generation Drug-Eluting or Bare-Metal Stent Implantation in All-Comer Patients Undergoing Percutaneous Coronary Intervention. JACC Cardiovasc Interv 2014; 7:20-8. [DOI: 10.1016/j.jcin.2013.09.008] [Citation(s) in RCA: 80] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2013] [Accepted: 09/28/2013] [Indexed: 10/25/2022]
|
249
|
Gao RL, Xu B, Lansky AJ, Yang YJ, Ma CS, Han YL, Chen SL, Li H, Zhang RY, Fu GS, Yuan ZY, Jiang H, Huo Y, Li W, Zhang YJ, Leon MB. A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial. EUROINTERVENTION 2013; 9:75-83. [PMID: 23685298 DOI: 10.4244/eijv9i1a12] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
AIMS The study sought to evaluate the safety and efficacy of FIREHAWK, a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent (SES) for treating patients with single de novo coronary lesions compared with the durable polymer everolimus-eluting stent (EES) XIENCE V. METHODS AND RESULTS A total of 458 patients with single de novo native coronary lesions ≤24 mm in length and a coronary artery ≥2.25 to ≤4.0 mm in diameter were enrolled in the TARGET I study, a prospective, randomised, non-inferiority trial. The primary endpoint was in-stent late lumen loss (LLL) at nine-month follow-up. The secondary endpoint, target lesion failure (TLF), was defined as the composite of cardiac death, target vessel myocardial infarction (TVMI), or ischaemia-driven target lesion revascularisation (iTLR). Patients were centrally randomised to treatment with either biodegradable polymer SES (n=227) or durable polymer EES (n=231). The nine-month in-stent LLL of the biodegradable polymer SES was comparable to the EES group (0.13 ± 0.24 mm vs. 0.13 ± 0.18 mm, p=0.94; difference and 95% confidence interval 0.00 [-0.04, 0.04] mm; p for non-inferiority <0.0001). Cardiac death (0.4% vs. 0.0%), TVMI (1.3% vs. 1.7%), iTLR (0.4% vs. 0.4%) and TLF (2.2% vs. 2.2%) were similar between the biodegradable polymer SES and durable polymer EES groups at 12-month follow-up (all p>0.05). No definite/probable stent thrombosis was observed in both of these groups. CONCLUSIONS In the multicentre TARGET I trial, the novel abluminal groove-filled biodegradable polymer SES FIREHAWK was non-inferior to the durable polymer EES XIENCE V with respect to the primary endpoint of in-stent LLL at nine months for treating patients with single de novo coronary lesions. The incidences of clinical endpoints were low in both of the stents at 12-month follow-up. (ClinicalTrials.gov identifier: NCT01196819).
Collapse
Affiliation(s)
- Run-Lin Gao
- Fu Wai Hospital, National Center for Cardiovascular Diseases of China, Beijing, China.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
250
|
Foerst J, Vorpahl M, Engelhardt M, Koehler T, Tiroch K, Wessely R. Evolution of Coronary Stents: From Bare-Metal Stents to Fully Biodegradable, Drug-Eluting Stents. ACTA ACUST UNITED AC 2013. [DOI: 10.1007/s13556-013-0005-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|