201
|
Dora C, Burckhardt K, Székely G, Rousson V, Hodler J, Gerber C. A computerized analysis-by-synthesis algorithm improves precision of linear wear measurements in total hip replacements. J Orthop Res 2008; 26:1121-6. [PMID: 18327802 DOI: 10.1002/jor.20643] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Precision is important if small polyethylene wear rates are to be detected early and in small sample sizes. Using an automatic, computerized algorithm relying on a synthetic X-ray generated from a computer-assisted design (CAD) model of the implant may significantly improve precision of linear wear measurements. We compared this method to provide improved in vivo precision compared to the widely used Hip Analysis Suite software (version 8.0.1.7). Two anterior-posterior pelvic X-rays were taken on the same day of 18 total hip implants, and wear was measured by three observers using the two methods. Expected real wear was zero and defined as a reference value. Two sources of variability were estimated: one due to the instrument, and one due to different operators. A Wilcoxon Signed Rank Test was used for statistical comparisons. The overall precision (instrument variability and multioperator variability) given a 95% precision limit was significantly higher (p < 0.001) using the proposed method (+/-0.15 mm) when compared to the Hip Analysis Suite (+/-0.84 mm). Due to the availability of the full CAD data of the implant and to further automation of the measuring process, the newly proposed method provided improved precision in measuring polyethylene wear.
Collapse
Affiliation(s)
- Claudio Dora
- Department of Orthopedics, University of Zurich, Balgrist, Forchstrasse 340, CH-8008 Zurich, Switzerland.
| | | | | | | | | | | |
Collapse
|
202
|
Hurschler C, Seehaus F, Emmerich J, Kaptein BL, Windhagen H. Accuracy of model-based RSA contour reduction in a typical clinical application. Clin Orthop Relat Res 2008; 466:1978-86. [PMID: 18509712 PMCID: PMC2584241 DOI: 10.1007/s11999-008-0287-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2007] [Accepted: 04/22/2008] [Indexed: 01/31/2023]
Abstract
Marker-based roentgen stereophotogrammetric analysis (RSA) is an accurate method for measuring in vivo implant migration, which requires attachment of tantalum markers to the implant. Model-based RSA allows migration measurement without implant markers; digital pose estimation, which can be thought of as casting a shadow of a surface model of the implant into the stereoradiographs, is used instead. The number of surface models required in a given clinical study depends on the number of implanted sizes and design variations of prostheses. Contour selection can be used to limit pose estimation to areas of the prosthesis that do not vary with design, reducing the number of surface models required. The effect of contour reduction on the accuracy of the model-based method was investigated using three different contour selection schemes on tibial components in 24 patients at 3 and 6 month followup. The agreement interval (mean +/- 2 standard deviations), which bounds the differences between the marker-based and model-based methods with contour reduction was smaller than -0.028 +/- 0.254 mm. The data suggest that contour reduction does not result in unacceptable loss of model-based RSA accuracy, and that the model-based method can be used interchangeably with the marker-based method for measuring tibial component migration.
Collapse
Affiliation(s)
- Christof Hurschler
- Department of Orthopaedics, Laboratory for Biomechanics and Biomaterials, Hannover Medical School, Anna-von-Borries-Str 1-7, 30625 Hannover, Germany
| | - Frank Seehaus
- Department of Orthopaedics, Laboratory for Biomechanics and Biomaterials, Hannover Medical School, Anna-von-Borries-Str 1-7, 30625 Hannover, Germany
| | - Judith Emmerich
- Department of Orthopaedics, Laboratory for Biomechanics and Biomaterials, Hannover Medical School, Anna-von-Borries-Str 1-7, 30625 Hannover, Germany
| | - Bart L. Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands ,Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Henning Windhagen
- Department of Orthopaedics, Laboratory for Biomechanics and Biomaterials, Hannover Medical School, Anna-von-Borries-Str 1-7, 30625 Hannover, Germany
| |
Collapse
|
203
|
Hansson U, Ryd L, Toksvig-Larsen S. A randomised RSA study of Peri-Apatite HA coating of a total knee prosthesis. Knee 2008; 15:211-6. [PMID: 18329882 DOI: 10.1016/j.knee.2008.01.013] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2007] [Revised: 01/07/2008] [Accepted: 01/10/2008] [Indexed: 02/02/2023]
Abstract
BACKGROUND In total knee replacement, sound early fixation of the prosthesis is crucial for achieving a good long-term result and for minimising the risk of loosening. Various types of prosthetic material, different surface textures and shapes and the incorporation of screws or pegs have been used to achieve good fixation, particularly in the uncemented knee. Hydroxyapatite (HA) coating of prosthetic joint components is another technique used to enhance early stability and so to improve the longevity of the prosthesis-bone fixation. HA ceramic coatings are mostly plasma sprayed onto the fixation surface of the implant. Plasma spraying is largely a 'line of sight' technique and as such there are difficulties involved when covering three-dimensional planes, such as porous beaded fixation surfaces typically found on several knee prostheses. The objective of this study was to assess the clinical performance of the solution-deposited HA coating, Peri-Apatite , with regard to its ability to stimulate an endurable and stable implant fixation. PATIENTS AND METHODS We randomised 60 patients into two groups; one group received the porous coated prosthesis with solution-deposited HA, and the other group received a prosthesis without HA. Radiostereometric examination was used as the primary tool for measuring migration in the prosthetic components. RESULTS There was a lower incidence of early subsidence in the Peri-Apatite group. At 24 months there were no differences in clinical scorings or maximal total point motion. CONCLUSION Addition of solution-deposited HA coating appears to provide better early stable fixation in a porous coated knee prosthesis.
Collapse
Affiliation(s)
- Ulrik Hansson
- Department of Orthopaedics, Lund University Hospital, 22185 Lund, Sweden.
| | | | | |
Collapse
|
204
|
Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelines. J Orthop Traumatol 2008; 9:63-7. [PMID: 19384618 PMCID: PMC2656955 DOI: 10.1007/s10195-008-0008-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2007] [Accepted: 01/25/2008] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND Bioactive coating of uncemented total knee arthroplasty (TKA) is believed to increase bone ingrowth and enhance early fixation of the TKA. In a prospective randomized study using radiostereometric analysis (RSA) we examined migrations of the tibial implant, in an uncemented TKA with and without bioactive coating. The study was performed according to new RSA guidelines, and focus was put on some important methodological issues. MATERIALS AND METHODS Twenty-three patients with osteoarthrosis of the knee received an uncemented Duracon TKA either with bioactive (hydroxyapatite or periapatite) coating (+HA) or without bioactive coating (-HA). Patients had RSA examinations postoperatively and at 3, 6 and 12 months. Nine patients were excluded during the study resulting in 14 knees for final analysis. RESULTS At 12 months follow-up we found no significant differences in migrations between the two groups. However, in general the -HA group migrated more than the +HA group, and we found a significant larger variation in migration pattern in the -HA group. In the +HA group the tibia component stabilized after 6 months, whereas the -HA group showed continuous migration. Subsidence and posterior tilt were the main migration patterns in both groups. CONCLUSIONS Bioactive coating of TKA seems to enhance early stabilization of the tibia component. Similar results are found in previous studies.
Collapse
|
205
|
Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. J Biomech 2008; 41:1616-22. [PMID: 18394629 DOI: 10.1016/j.jbiomech.2008.01.034] [Citation(s) in RCA: 166] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2007] [Revised: 12/21/2007] [Accepted: 01/24/2008] [Indexed: 11/23/2022]
Abstract
The accurate measurement of the in vivo knee joint kinematics in six degrees-of-freedom (6DOF) remains a challenge in biomedical engineering. We have adapted a dual fluoroscopic imaging system (DFIS) to investigate the various in vivo dynamic knee joint motions. This paper presents a thorough validation of the accuracy and repeatability of the DFIS system when used to measure 6DOF dynamic knee kinematics. First, the validation utilized standard geometric spheres made from different materials to demonstrate the capability of the DFIS technique to determine the object positions under changing speeds. The translational pose of the spheres could be recreated to less than 0.15+/-0.09 mm for velocities below 300 mm/s. Next, tantalum beads were inserted into the femur and tibia of two fresh frozen cadaver knees to compare the dynamic kinematics measured by matching knee models to the kinematics from the tantalum bead matching-a technique similar to Roentgen stereophotogrammetric analysis (RSA). Each cadaveric knee was attached to the crosshead of a tensile testing machine and vertically translated at a rate of 16.66 mm/s while images were captured with the DFIS. Subsequently, the tibia was held fixed and the femur manually flexed from full extension to 90 degrees of flexion, as the DFIS acquired images. In vitro translation of the cadaver knee using the tensile testing machine deviated from predicted values by 0.08+/-0.14 mm for the matched knee models. The difference between matching the knee and tantalum bead models during the dynamic flexion-extension motion of the knee was 0.1+/-0.65 degrees /s in flexion speed; 0.24+/-0.16 mm in posterior femoral translation; and 0.16+/-0.61 degrees in internal-external tibial rotation. Finally, we applied the method to investigate the knee kinematics of a living subject during a step ascent and treadmill gait. High repeatability was demonstrated for the in vivo application. Thus, the DFIS provides an easy and powerful tool for accurately determining 6DOF positions of the knee when performing daily functional activities.
Collapse
|
206
|
The B, Flivik G, Diercks RL, Verdonschot N. A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs. Clin Orthop Relat Res 2008; 466:684-90. [PMID: 18264857 PMCID: PMC2505227 DOI: 10.1007/s11999-007-0077-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2007] [Accepted: 11/12/2007] [Indexed: 01/31/2023]
Abstract
Wear curves from individual patients often show unexplained irregular wear curves or impossible values (negative wear). We postulated errors of two-dimensional wear measurements are mainly the result of radiographic projection differences. We tested a new method that makes two-dimensional wear measurements less sensitive for radiograph projection differences of cemented THAs. The measurement errors that occur when radiographically projecting a three-dimensional THA were modeled. Based on the model, we developed a method to reduce the errors, thus approximating three-dimensional linear wear values, which are less sensitive for projection differences. An error analysis was performed by virtually simulating 144 wear measurements under varying conditions with and without application of the correction: the mean absolute error was reduced from 1.8 mm (range, 0-4.51 mm) to 0.11 mm (range, 0-0.27 mm). For clinical validation, radiostereometric analysis was performed on 47 patients to determine the true wear at 1, 2, and 5 years. Subsequently, wear was measured on conventional radiographs with and without the correction: the overall occurrence of errors greater than 0.2 mm was reduced from 35% to 15%. Wear measurements are less sensitive to differences in two-dimensional projection of the THA when using the correction method.
Collapse
Affiliation(s)
- Bertram The
- Department of Orthopaedic Surgery, University Medical Center Groningen, Hanzeplein 1, 9700 RB Groningen, The Netherlands
| | - Gunnar Flivik
- Department of Orthopaedic Surgery, Lund University Hospital, Lund, Sweden
| | - Ron L. Diercks
- Department of Orthopaedic Surgery, University Medical Center Groningen, Hanzeplein 1, 9700 RB Groningen, The Netherlands
| | - Nico Verdonschot
- Department of Orthopaedic Biomechanics, Radboud University Nijmegen, Nijmegen, The Netherlands
| |
Collapse
|
207
|
Hazle CR, Nitz AJ. Evidence-based assessment and diagnosis of pelvic girdle disorders: a proposal for an alternate diagnostic category. PHYSICAL THERAPY REVIEWS 2008. [DOI: 10.1179/174328808x251975] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
208
|
Abstract
Prospective, randomized clinical wear studies have shown significant wear reduction when highly cross-linked, e-beamed, melted polyethylene was compared with conventional polyethylene sterilized by gamma irradiation in air. More complete assessment of wear-induced osteolysis in the general total hip arthroplasty patient population must rely on registries with follow-up of large populations of patients through radiographic evaluation of wear-related factors, such as suboptimal placement of the implant components, osteolytic defects, and aseptic loosening. Follow-up radiographs should be obtained in the early postoperative period and at 1, 5, and 10 years postoperatively, and then every 1 to 5 years, thereafter depending on radiographic findings of osteolysis and its progression. When pathologic findings are present, further examinations, such as oblique Judet views and magnetic resonance imaging (MRI) with artifact minimization should be considered to provide a better determination of the extent of the osteolysis. Because conventional radiographs underestimate the prevalence and extent of osteolysis in many instances, diagnosis and surveillance should be performed with radiographic edge detection, spiral computed tomography (CT), MRI, radiostereometric analysis, and quantitation of wear and osteolysis, including bone and soft-tissue lesions. Helical CT has demonstrated excellent specificity in identifying and quantifying the extent of osteolysis. MRI can more accurately localize both osseous and soft-tissue particulate disease, and detect granuloma and compression on adjacent nerves and vessels.
Collapse
|
209
|
Russo A, Bragonzoni L, Trozzi C, Zaffagnini S, Neri MP, Bruni D, Marcacci M. Recurrence of varus/valgus deformity after TKR at 3 years' follow-up. Knee 2008; 15:20-5. [PMID: 18053725 DOI: 10.1016/j.knee.2007.09.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2007] [Revised: 09/03/2007] [Accepted: 09/25/2007] [Indexed: 02/02/2023]
Abstract
We assessed 30 patients with a cemented TKR implant (Interax ISA, Stryker Orthopaedics) at 1 and 3 years follow-up. We wanted to ascertain whether knee alignment was maintained during the critical period of follow-up in meniscal-bearing PCL-retaining TKR patients and test if correlations exist between alignment variations in the coronal plane and preoperative varus/valgus deformity or tibial component position and migration with respect to the tibia. Lower limb alignment was evaluated by measuring the angle between the tibia and femur anatomical axis directly from the antero-posterior radiographs and the tibial component position with respect to the tibial anatomical axis. The tibial component varus/valgus migration in the tibia was measured by roentgen stereophotogrammetric analysis. The results showed that at 3 years follow-up 40% of patients presented an alignment variation of over 3 degrees . The recurrent deformity was not correlated with the preoperative deformity, nor with the tibial component position with respect to the tibial shaft nor with its migration. After total knee arthroplasty coronal axial variation is a common finding and it depends on the overall limb muscles and ligaments adaptation to prosthetic constraints.
Collapse
|
210
|
de Bruin PW, Kaptein BL, Stoel BC, Reiber JHC, Rozing PM, Valstar ER. Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D–3D image registration. J Biomech 2008; 41:155-64. [PMID: 17706656 DOI: 10.1016/j.jbiomech.2007.07.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2007] [Revised: 07/01/2007] [Accepted: 07/02/2007] [Indexed: 10/22/2022]
Abstract
Image-based Roentgen stereophotogrammetric analysis (IBRSA) integrates 2D-3D image registration and conventional RSA. Instead of radiopaque RSA bone markers, IBRSA uses 3D CT data, from which digitally reconstructed radiographs (DRRs) are generated. Using 2D-3D image registration, the 3D pose of the CT is iteratively adjusted such that the generated DRRs resemble the 2D RSA images as closely as possible, according to an image matching metric. Effectively, by registering all 2D follow-up moments to the same 3D CT, the CT volume functions as common ground. In two experiments, using RSA and using a micromanipulator as gold standard, IBRSA has been validated on cadaveric and sawbone scapula radiographs, and good matching results have been achieved. The accuracy was: |mu |< 0.083 mm for translations and |mu| < 0.023 degrees for rotations. The precision sigma in x-, y-, and z-direction was 0.090, 0.077, and 0.220 mm for translations and 0.155 degrees , 0.243 degrees , and 0.074 degrees for rotations. Our results show that the accuracy and precision of in vitro IBRSA, performed under ideal laboratory conditions, are lower than in vitro standard RSA but higher than in vivo standard RSA. Because IBRSA does not require radiopaque markers, it adds functionality to the RSA method by opening new directions and possibilities for research, such as dynamic analyses using fluoroscopy on subjects without markers and computer navigation applications.
Collapse
Affiliation(s)
- P W de Bruin
- Orthopaedics Department, Leiden University Medical Center, Leiden, The Netherlands
| | | | | | | | | | | |
Collapse
|
211
|
Cai R, Yuan X, Rorabeck C, Bourne RB, Holdsworth DW. Development of an RSA calibration system with improved accuracy and precision. J Biomech 2007; 41:907-11. [PMID: 18096170 DOI: 10.1016/j.jbiomech.2007.11.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2007] [Revised: 11/12/2007] [Accepted: 11/13/2007] [Indexed: 10/22/2022]
Abstract
In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict the performance of the designed cage before it was actually fabricated; and an experimental phantom test was finally conducted to verify the actual performance of the new cage and compare with two currently widely used cages. Accuracy was calculated as the 95% prediction intervals from regression analyses between the measured and actual displacements, and precision was defined as the standard deviation of repeated measurements. The final experimental phantom tests showed that the accuracy and precision of the new calibration cage were improved by about 40% over an existing biplanar cage and by about 70% compared to a uniplanar cage design. This new cage can be used with any skeletal joints, in either static or kinematic examination, which is helpful for the standardization of the RSA application.
Collapse
Affiliation(s)
- Rongyi Cai
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada N6A 5K8
| | | | | | | | | |
Collapse
|
212
|
Digas G, Kärrholm J, Thanner J, Herberts P. 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop 2007; 78:746-54. [PMID: 18236180 DOI: 10.1080/17453670710014518] [Citation(s) in RCA: 147] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Laboratory tests and early clinical studies have shown that highly cross-linked polyethylene (PE) markedly improves wear resistance compared to conventional PE. We evaluated this type of PE in two randomized clinical studies using radiostereometric analysis (RSA). The 2- and 3-year follow-up of these studies have already been reported. We found a lower penetration rate for the highly cross-linked PE than for conventional PE. We now report the outcome after 5 years. PATIENTS AND METHODS 60 patients (61 hips) with a median age of 55 years were randomized to receive either highly cross-linked PE (Durasul) or conventional cemented all-polyethylene sockets of the same design. 55 patients (56 hips) were followed for 5 years. In the second study, 32 patients (64 hips) with a median age of 48 years and with bilateral primary or secondary osteoarthritis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked PE (Longevity) on one side and conventional PE on the other. 23 patients in this study have passed the 5-year follow-up. RESULTS Bedding-in and creep for the Durasul all-PE was reached by 2 years, and by 1 year for the Longevity liners. In both control groups with conventional PE, this was reached by 6 months. The steady-state wear rate was close to zero in the two study groups and 0.06 mm/year for the conventional PE in the two control groups. INTERPRETATION We found that use of highly crosslinked PE instead of conventional PE reduced the wear by more than 95%, which supports continued use of this type of PE in young, active patients.
Collapse
Affiliation(s)
- Georgios Digas
- Department of Orthopedics, Institute of Surgical Science, Sahlgrenska University Hospital, Göteborg University, Göteborg, Sweden.
| | | | | | | |
Collapse
|
213
|
Ström H, Nilsson O, Milbrink J, Mallmin H, Larsson S. The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 2007; 22:1122-9. [PMID: 18078880 DOI: 10.1016/j.arth.2006.11.015] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2005] [Revised: 08/09/2006] [Accepted: 11/26/2006] [Indexed: 02/01/2023] Open
Abstract
Forty-two patients (younger than 65 years) with osteoarthritis were operated on with an uncemented CLS stem and randomized to early unrestricted weight bearing combined with intensive physiotherapy or to partial weight bearing combined with self-training. Radiostereometric analysis showed 1.2 (+0.11 to -6.76) mm subsidence of the stem at 24 months in both groups. There was no significant difference in the migration pattern between the unrestricted and partial weight bearing groups. Actual loading on the operated leg, measured with the F-scan system, did not influence the migration of the stem. There was a strong correlation between the average subsidence at 3 and 24 months (r = 0.96). Early full weight bearing and active rehabilitation can be used for the uncemented CLS stem without increased risk of early loosening.
Collapse
Affiliation(s)
- Håkan Ström
- Department of Orthopaedics, University of Uppsala, Uppsala, Sweden
| | | | | | | | | |
Collapse
|
214
|
Axelsson P, Johnsson R, Strömqvist B. Adjacent segment hypermobility after lumbar spine fusion: no association with progressive degeneration of the segment 5 years after surgery. Acta Orthop 2007; 78:834-9. [PMID: 18236192 DOI: 10.1080/17453670710014635] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND AND PURPOSE Increased intradiscal pressure and relative segmental hypermobility are in vitro observations supporting the idea of increased postoperative load being a reason for progressive degeneration of the free mobile segment adjacent to a lumbar fusion. These mechanisms have been difficult to confirm in clinical studies, and an alternative theory claims instead that the adjacent segment degeneration follows a natural degenerative course in patients who are predisposed. We examined 9 patients 5 years after lumbar fusion, to assess whether relative hypermobility of the segment adjacent to fusion could be correlated to progressive degeneration of the same segment. PATIENTS AND METHODS The 9 patients, all of whom had been treated with a lumbar fusion after a preoperative intervertebral mobility assessment by spinal RSA, were re-examined 5 years after surgery. The intervertebral translations of the vertebra proximal to the fusion were determined by RSA and compared to the mobility of the same lumbar segment before fusion. The disc height and any progressive reduction at the two levels proximal to the one fused were measured on conventional radiographs. RESULTS Adjacent segment mobility 5 years after fusion--expressed as mean transverse, vertical, and sagittal translation of the vertebra proximal to fusion--was not significantly changed compared to the mobility measured before surgery. Increased mobility of the segment seen in 5 individual patients was not associated with progressive degeneration of the same segment or to a poor clinical outcome. INTERPRETATION Hypermobility of the segment adjacent to fusion is not a general finding. Increased mobility that can be seen in certain individuals does not impair the 5-year result. The significance of mechanical alterations in adjacent segment degeneration is uncertain, and it is possibly overestimated.
Collapse
Affiliation(s)
- Paul Axelsson
- Department of Orthopedics, Lund University Hospital, Lund, Sweden.
| | | | | |
Collapse
|
215
|
|
216
|
The B, Hosman A, Kootstra J, Kralj-Iglic V, Flivik G, Verdonschot N, Diercks R. Association between contact hip stress and RSA-measured wear rates in total hip arthroplasties of 31 patients. J Biomech 2007; 41:100-5. [PMID: 17942102 DOI: 10.1016/j.jbiomech.2007.07.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2007] [Revised: 06/23/2007] [Accepted: 07/11/2007] [Indexed: 02/08/2023]
Abstract
BACKGROUND The main concern in the long run of total hip replacements is aseptic loosening of the prosthesis. Optimization of the biomechanics of the hip joint is necessary for optimization of long-term success. A widely implementable tool to predict biomechanical consequences of preoperatively planned reconstructions still has to be developed. A potentially useful model to this purpose has been developed previously. The aim of this study is to quantify the association between the estimated hip joint contact force by this biomechanical model and RSA-measured wear rates in a clinical setting. METHODS Thirty-one patients with a total hip replacement were measured with RSA, the gold standard for clinical wear measurements. The reference examination was done within 1 week of the operation and the follow-up examinations were done at 1, 2 and 5 years. Conventional pelvic X-rays were taken on the same day. The contact stress distribution in the hip joint was determined by the computer program HIPSTRESS. The procedure for the determination of the hip joint contact stress distribution is based on the mathematical model of the resultant hip force in the one-legged stance and the mathematical model of the contact stress distribution. The model for the force requires as input data, several geometrical parameters of the hip and the body weight, while the model for stress requires as input data, the magnitude and direction of the resultant hip force. The stress distribution is presented by the peak stress-the maximal value of stress on the weight-bearing area (p(max)) and also by the peak stress calculated with respect to the body weight (p(max)/W(B)) which gives the effect of hip geometry. Visualization of the relations between predicted values by the model and the wear at different points in the follow-up was done using scatterplots. Correlations were expressed as Pearson r values. RESULTS The predicted p(max) and wear were clearly correlated in the first year post-operatively (r = 0.58, p = 0.002), while this correlation is weaker after 2 years (r = 0.19, p = 0.337) and 5 years (r = 0.24, p = 0.235). The wear values at 1, 2 and 5 years post-operatively correlate with each other in the way that is expected considering the wear velocity curve of the whole group. The correlation between the predicted p(max) values of two observers who were blinded for each other's results was very good (r = 0.93, p < 0.001). CONCLUSION We conclude that the biomechanical model used in this paper provides a scientific foundation for the development of a new way of constructing preoperative biomechanical plans for total hip replacements.
Collapse
Affiliation(s)
- Bertram The
- Orthopaedic Surgery, University Medical Center Groningen, Hanzeplein 1, Postbus 30.001, 9700 RB Groningen, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
217
|
Abstract
Intervertebral instability of the lumbar spine is thought to be a possible pathomechanical mechanism underlying low back pain and sciatica and is often an important factor in determining surgical indication for spinal fusion and decompression. Instability of the lumbar spine, however, remains a controversial and poorly understood topic. At present, much controversy exists regarding the proper definition of the condition, the best diagnostic methods, and the most efficacious treatment approaches. Clinical presentation is not specific, and the relationship between radiologic evidence of instability and its symptoms is controversial. Because of its simplicity, low expense, and pervasive availability, functional flexion-extension radiography is the most thoroughly studied and the most widely used method in the imaging diagnosis of lumbar intervertebral instability. In this article, we provide an overview of the current concepts of vertebral instability, focusing on degenerative lumbar intervertebral instability, and review the different imaging modalities most indicated in diagnosing vertebral instability.
Collapse
Affiliation(s)
- Antonio Leone
- Department of Radiology, Catholic University, School of Medicine, Largo A. Gemelli 8, 00168 Rome, and Department of Radiology, Scientific Institute Hospital Casa Sollievo della Sofferenza, San Giovanni Rotondo, Italy.
| | | | | | | |
Collapse
|
218
|
Koning OHJ, Kaptein BL, Garling EH, Hinnen JW, Hamming JF, Valstar ER, van Bockel JH. Assessment of three-dimensional stent-graft dynamics by using fluoroscopic roentgenographic stereophotogrammetric analysis. J Vasc Surg 2007; 46:773-9. [PMID: 17764877 DOI: 10.1016/j.jvs.2007.05.054] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2007] [Accepted: 05/23/2007] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To validate the use of fluoroscopic roentgenographic stereophotogrammetric analysis (FRSA) for its feasibility and accuracy for measuring the three-dimensional dynamic motion of stent grafts. METHODS A digital biplane fluoroscopy setup was calibrated (Siemens Axiom Artis dBc). Stereo images were acquired of a static aortic model with a stent graft in different axial positions, imposed by a micromanipulator. The three-dimensional measurement error of FRSA was determined by comparing FRSA measurements with the micromanipulator. An aortic model with a stent graft was constructed and connected to an artificial circulation with a physiological flow and pressure profile. Markers were added to the spine (tantalum spherical markers; diameter 1 mm) and stent (welding tin; diameter 1 mm). The three-dimensional measurement precision was determined by measuring the position of a single (stable) spine marker during two pulsatile cycles. Finally, three-dimensional stent marker motion was analyzed with a frame rate of 30 images per second, including three-dimensional marker position (change), diameter change, and center of circle position change. RESULTS The mean error of FRSA measurement of displacement was 0.003 mm (SD, 0.019 mm; maximum error, 0.058 mm). A very high precision of position measurement was found (SD, 0.009-0.015 mm). During pulsatile motion, the position (changes) of the markers could be assessed in the x, y, and z directions, as well as the stent diameter change and center of circle position change. CONCLUSIONS FRSA has proven to be a method with very high accuracy and temporal resolution to measure three-dimensional stent-graft motion in a pulsatile environment. This technique has the potential to contribute significantly to the knowledge of stent-graft behavior after endovascular aneurysm repair and improvements in stent-graft design. The technique is ready for clinical testing.
Collapse
Affiliation(s)
- Olivier H J Koning
- Department of Surgery, Division of Vascular Surgery, Leiden University Medical Center, Leiden, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
219
|
Khan RT, Lie DT, Cashman PM, Thomas RW, Amis AA. Measurement of laxity in the anterior cruciate ligament-deficient knee: A comparison of three different methods in vitro. Proc Inst Mech Eng H 2007; 221:653-63. [DOI: 10.1243/09544119jeim182] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The aim of this study was to compare in-vitro measurements of anteroposterior laxity in the anterior cruciate ligament (ACL)-deficient knee using three different methods: an Instron materials-testing machine, then a KT-2000 arthrometer, and finally by Roentgen stereophotogrammetric analysis (RSA). Eight ACL-deficient human cadaver knees were used. Total displacement was measured between 90 N anterior and 90 N posterior tibiofemoral drawer forces at both 20° and 90° knee flexion. Laxity ranged from 11.5 to 27.6 mm at 20° and from 8.7 to 23.9 mm at 90°. A statistically significant difference was not found between the mean RSA and KT-2000 measurements. However, the mean Instron measurements of laxity were significantly (3-4 mm) higher than both RSA and KT-2000 measurements. The clinical methods of RSA and the KT-2000 measurements agreed well but appeared to underestimate tibiofemoral anteroposterior laxity compared with the materials-testing machine. These findings may be helpful in the future comparison of different studies.
Collapse
Affiliation(s)
- R T Khan
- Musculoskeletal Surgery, Imperial College London, London, UK
| | - D T Lie
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - P M Cashman
- Department of Bioengineering, Imperial College London, London, UK
| | - R W Thomas
- Musculoskeletal Surgery, Imperial College London, London, UK
| | - A A Amis
- Musculoskeletal Surgery, Imperial College London, London, UK
- Department of Mechanical Engineering, Imperial College London, London, UK
| |
Collapse
|
220
|
Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H. Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty 2007; 22:125-9. [PMID: 17823030 DOI: 10.1016/j.arth.2007.03.009] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2007] [Accepted: 03/07/2007] [Indexed: 02/01/2023] Open
Abstract
This study used radiostereometric analysis (RSA) to compare the femoral head penetration of 28- vs 36-mm-diameter femoral heads into highly cross-linked polyethylene in 2 groups of total hip arthroplasty patients. Thirty patients were enrolled in this RSA study using highly cross-linked polyethylene (Longevity, Zimmer Inc, Warsaw, Idaho) against either 28- or 36-mm-diameter cobalt chrome femoral heads. At 3-year follow-up, there was no significant difference in the total average femoral head penetration, including both creep and wear, using 3 methods of RSA measurement between the 2 groups. Importantly, after bedding-in, there was no further significant increase in the amount of femoral head penetration (ie, wear) with either head size between years 1 and 3. There were no radiographic signs of lysis or radiolucencies at a minimum 3-year follow-up.
Collapse
Affiliation(s)
- Charles R Bragdon
- Orthopaedic Biomechanics and Biomaterials Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, USA
| | | | | | | | | |
Collapse
|
221
|
Baad-Hansen T, Kold S, Kaptein BL, Søballe K. High-precision measurements of cementless acetabular components using model-based RSA: an experimental study. Acta Orthop 2007; 78:463-9. [PMID: 17965999 DOI: 10.1080/17453670710014095] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years, new software systems have been developed to solve this problem. We compared the precision of 3 RSA systems in migration analysis of the acetabular component. MATERIAL AND METHODS A hemispherical and a non-hemispherical acetabular component were mounted in a phantom. Both acetabular components underwent migration analyses with 3 different RSA systems: conventional RSA using tantalum markers, an RSA system using a hemispherical cup algorithm, and a novel model-based RSA system. RESULTS We found narrow confidence intervals, indicating high precision of the conventional marker system and model-based RSA with regard to migration and rotation. The confidence intervals of conventional RSA and model-based RSA were narrower than those of the hemispherical cup algorithm-based system regarding cup migration and rotation. INTERPRETATION The model-based RSA software combines the precision of the conventional RSA software with the convenience of the hemispherical cup algorithm-based system. Based on our findings, we believe that these new tools offer an improvement in the measurement of acetabular component migration.
Collapse
|
222
|
Abstract
STUDY DESIGN Prospective, radiostereometric study of the Bryan Cervical Disc prosthesis (Medtronic Sofamor Danek, Memphis, TN) for the treatment of a single-level disc disease of the cervical spine. OBJECTIVE To study the stability of the titanium endplates of the disc prosthesis at the interface between the bone and prosthesis. SUMMARY OF BACKGROUND DATA Cervical disc prosthesis is a motion-sparing technology in which the longevity is dependent on initial fixation as well as secondary fixation with bone ingrowth into the surface of the device. Little is known regarding the stability of this fixation with the currently studied prosthesis. METHODS Eleven patients with symptomatic cervical radiculopathy underwent implantation of a radiostereometry modified Bryan prosthesis after a standard anterior cervical discectomy. The adjacent vertebrae were perioperatively marked with tantalum markers. The patients were then frequently studied with radiostereometric radiographs and evaluated for pain, and neurologic and physical function for 2 years. RESULTS Both titanium endplates of the device were immediately stable in 5 patients. Small but measurable changes (micromotions) were recorded in 4 patients until the 3-month examination and in 2 patients at the 3-6-month time period. All prostheses continued to be stable after 6 months until the final assessment at 2 years after surgery. The recorded micromotions did not influence the clinical results. CONCLUSIONS The Bryan prosthesis is immediately stable in many patients and is securely fixed to the bone within 3-6 months in all patients. The result of this study suggests that there is sufficient bone ingrowth on the coated surface of the Bryan prosthesis endplates to stabilize securely the prosthesis.
Collapse
Affiliation(s)
- Bengt Lind
- Department of Orthopaedics, Sahlgrenska University Hospital, Göteborg, Sweden.
| | | | | |
Collapse
|
223
|
Lind BI, Zoega B, Rosén H. Autograft versus interbody fusion cage without plate fixation in the cervical spine: a randomized clinical study using radiostereometry. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2007; 16:1251-6. [PMID: 17342510 PMCID: PMC2200784 DOI: 10.1007/s00586-007-0337-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2005] [Revised: 02/28/2006] [Accepted: 02/11/2007] [Indexed: 10/23/2022]
Abstract
A primary object with a fusion cage is avoidance of graft collapse with subsequent subsidence and malalignment of the cervical spine that is observed after bone grafting alone. No randomized studies exist that demonstrate the difference between these two methods in terms of graft subsidence and angulation of the fused segment. The size of the study population was calculated to be 24 patients to reach a significant difference at the 95% CI level. Patients with one-level cervical radiculopathy scheduled for surgery were randomized to anterior discectomy and fusion (ACDF) with autograft or to fusion cage, both without plate fixation. Tantalum markers were inserted in the two adjacent vertebrae at the end of surgery. Radiostereometry was performed immediately postoperatively and at regular intervals for 2 years. Questionnaires were used to evaluate the clinical outcome and an unbiased observer graded the outcome after 2 years. No significant differences were found between the two methods after 2 years in regard of narrowing of the disc space (mean 1.7 and 1.4 mm, respectively) or deformation of the fused segment into flexion (mean 7.7 degrees and 4.6 degrees , respectively). Patients in the cage group had a significantly better clinical outcome. The findings of subsidence and flexion deformation of the fused segment after 2 years seem to be of no clinical importance after one-level cervical disc surgery. However, in multi-level surgery using the same methods, an additive effect of the deformations of the fused segments may affect the clinical outcome.
Collapse
Affiliation(s)
- Bengt I Lind
- Department of Orthopaedics, Sahlgrenska University Hospital, Gröna stråket 8, 41345 Göteborg, Sweden.
| | | | | |
Collapse
|
224
|
Munro NA, Downing MR, Meakin JR, Lee AJ, Ashcroft GP. A hydroxyapatite graft substitute reduces subsidence in a femoral impaction grafting model. Clin Orthop Relat Res 2007; 455:246-52. [PMID: 16967033 DOI: 10.1097/01.blo.0000238828.65434.b0] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Synthetic bone graft substitutes have been developed for impaction grafting revision hip surgery in response to concerns about the availability and potential infection risk of allograft. We performed an in vitro experiment to determine whether a synthetic porous hydroxyapatite material might improve resistance to cumulative subsidence and cyclic (elastic) movement on loading. We impacted different ratios of hydroxyapatite and allograft (0%, 50%, 70%, and 90% hydroxyapatite) into composite femoral models (eight per group) and implanted tapered, polished stems with cement. Models were loaded for 18,000 cycles on a servohydraulic materials testing machine. Migration of the femoral prostheses and the distal cement was determined using radiostereometric analysis, and cyclic movement was measured mechanically by the testing machine. Hydroxyapatite decreased overall subsidence and subsidence at the prosthesis-cement interface, but there was no difference at the cement-femur interface. This decrease may have occurred because the hydroxyapatite-containing graft was more rigid, or because it resulted in a thicker cement mantle. Cyclic prosthesis movement also was lower with hydroxyapatite. While the biologic response to porous hydroxyapatite remains to be determined, its mechanical properties appear promising.
Collapse
Affiliation(s)
- Niall A Munro
- Orthopaedic Research Centre, Woodend Hospital, Aberdeen, UK.
| | | | | | | | | |
Collapse
|
225
|
Uvehammer J, Kärrholm J, Carlsson L. Cemented versus hydroxyapatite fixation of the femoral component of the Freeman-Samuelson total knee replacement. ACTA ACUST UNITED AC 2007; 89:39-44. [PMID: 17259414 DOI: 10.1302/0301-620x.89b1.17974] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We have carried out a radiostereometric study of 50 patients (54 knees) with osteoarthritis of the knee who were randomly allocated to receive a cemented or a hydroxyapatite-coated femoral component for total knee replacement. The patients were also stratified to receive one of three types of articulating surface (standard, rotating platform, Freeman-Samuelson (FS)1000) all based on the Freeman-Samuelson design. The tibial components were cemented in all cases. Radiostereometry was performed post-operatively and at 3, 12 and 24 months. The analysis was restricted to rotation of the femoral component over time. After two years, rotation of the femoral components in the transverse, longitudinal and sagittal planes did not differ between the cemented and the hydroxyapatite-coated implants (p = 0.2 to 0.9). In total knee replacements with a rotating platform, the femoral component tended to tilt more posteriorly than in the other two designs, regardless of the choice of fixation (cemented or hydroxyapatite-coated, p = 0.04). The standard version of the femoral component, whether cemented or hydroxyapatite-coated, rotated more into valgus than was observed with the rotating-platform and FS1000 designs (p = 0.005). The increased constraint provided by the FS1000 component did not appear to have any adverse effect on fixation of the femoral component.
Collapse
Affiliation(s)
- J Uvehammer
- Department of Orthopaedics, Lidköping Hospital, Lidköping, Sweden.
| | | | | |
Collapse
|
226
|
Beardsley CL, Paller DJ, Peura GD, Brattbakk B, Beynnon BD. The effect of coordinate system choice and segment reference on RSA-based knee translation measures. J Biomech 2007; 40:1417-22. [PMID: 16797021 DOI: 10.1016/j.jbiomech.2006.05.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2005] [Accepted: 05/07/2006] [Indexed: 11/26/2022]
Abstract
Roentgen stereophotogrammetric analysis (RSA) can be utilized to accurately describe joint kinematics, but even when measuring small displacements within radiographically discernible structures, standardized reference frames are imperative for useful comparison across patients and across studies. In the current paper, accurately controlled laboratory models demonstrated the considerable influence that a mere 1.9-cm offset of the origin of the coordinate system from the rotation axes could exert on translation measures when rotations were occurring. In addition, the use of two different coordinate systems to gauge translation on a radiographic anterior-posterior (A-P) knee laxity exam resulted in a significant correlation (R(2)=0.562) between the two systems; however, differences of up 9.28 mm were found between corresponding measurements. This implies that clinical conclusions can potentially be upheld or refuted, based on the same data set, subject to coordinate system definition. Although the data analyzed presently involved the knee joint, similar issues surround the RSA motion analysis of other joints as well.
Collapse
Affiliation(s)
- Christina L Beardsley
- McClure Musculoskeletal Research Center, University of Vermont, Stafford Hall, Burlington, VT 05405, USA.
| | | | | | | | | |
Collapse
|
227
|
Ström H, Nilsson O, Milbrink J, Mallmin H, Larsson S. Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res 2007; 454:127-32. [PMID: 16936584 DOI: 10.1097/01.blo.0000238785.98606.9d] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
We performed this investigation to determine the possible migration starting immediately after surgery and the effect of different weightbearing regimens on the migration pattern of an uncemented hip stem (CLS). Stem migration was determined with radiostereometry analysis with baseline when the patients still were anesthetized. Subsequent examinations were done up to 1 year. Twenty-nine patients (mean age, 55 years; range, 26-63 years) were randomized to either unrestricted weightbearing combined with intensive physiotherapy from the first day after surgery or to partial weightbearing and a conservative training regimen for the first 3 months after surgery. At 1 week, subsidence was -0.03 mm in the unrestricted weightbearing group and 0.01 mm in the partial weightbearing group. At 1 year, subsidence was 1.01 mm in the unrestricted weightbearing group and 0.51 mm in the partial weightbearing group. One patient in the unrestricted weightbearing group had revision surgery because of aseptic loosening at 1.5 years after surgery. The CLS stem did not have any migration from the end the surgery until 1 week, but there was small migration from 1 week to 3 months after which the stem remained stable. The degree of early weightbearing did not affect the migration pattern.
Collapse
Affiliation(s)
- Håkan Ström
- Department of Orthopaedics, University of Uppsala, Uppsala, Sweden
| | | | | | | | | |
Collapse
|
228
|
Küpper JC, Loitz-Ramage B, Corr DT, Hart DA, Ronsky JL. Measuring knee joint laxity: a review of applicable models and the need for new approaches to minimize variability. Clin Biomech (Bristol, Avon) 2007; 22:1-13. [PMID: 17056168 DOI: 10.1016/j.clinbiomech.2006.08.003] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2006] [Revised: 08/17/2006] [Accepted: 08/21/2006] [Indexed: 02/07/2023]
Abstract
Knee joint laxity can result from soft tissue injury, such as a ligament tear, or from genetic factors such as joint hypermobility syndrome and various forms of Ehlers-Danlos Syndrome. The location of a subject's passive knee laxity along a continuous spectrum is dependent on the mechanical properties of the existing structures, and the increased motion that often follows joint injury. At a threshold along the spectrum, a patient will be at risk for joint instability and further injury to joint structures. Links between instability and laxity may be better understood if laxity can be reliably and accurately quantified. Current measures of laxity have not been compared to a 'gold standard' in all cases, and when they have, were found to overestimate the laxity values. This is attributed to soft tissue deformation. Consequently, a noninvasive measure of laxity with improved accuracy and repeatability would be useful clinically and in the research sector. In this review, current clinical measures of laxity are critiqued, criteria for a measure of laxity are identified, and three theoretical models of knee laxity are outlined. These include contact, lumped parameter, and finite element models, with emphasis on applicability, strengths, and limitations of each. The long term goal is to develop a model and method able to differentiate subjects along a spectrum of laxity, and understand the functional implications of altered joint integrity. This would allow careful scrutiny of clinical interventions aimed at improving joint health and provide a valuable research tool to study joint injury, healing, and degeneration.
Collapse
Affiliation(s)
- J C Küpper
- Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada
| | | | | | | | | |
Collapse
|
229
|
Lauge-Pedersen H, Hägglund G, Johnsson R. Radiostereometric analysis for monitoring percutaneous physiodesis. A preliminary study. ACTA ACUST UNITED AC 2006; 88:1502-7. [PMID: 17075098 DOI: 10.1302/0301-620x.88b11.17730] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Percutaneous physiodesis is an established technique for treating mild leg-length discrepancy and problems of expected extreme height. Angular deformities resulting from incomplete physeal arrest have been reported, and little is known about the time interval from percutaneous physiodesis to actual physeal arrest. This procedure was carried out in ten children, six with leg-length discrepancy and four with expected extreme height. Radiostereometric analysis was used to determine the three-dimensional dynamics of growth retardation. Errors of measurement of translation were less than 0.05 mm and of rotation less than 0.06 degrees. Physeal arrest was obtained in all but one child within 12 weeks after physiodesis and no clinically-relevant angular deformities occurred. This is a suitable method for following up patients after percutaneous physiodesis. Incomplete physeal arrest can be detected at an early stage and the procedure repeated before corrective osteotomy is required.
Collapse
Affiliation(s)
- H Lauge-Pedersen
- Department of Orthopaedics, Lund University Hospital, S-22185 Lund, Sweden.
| | | | | |
Collapse
|
230
|
Abstract
Surgical treatment of fractures close to joints, especially in osteoporotic patients, is often associated with problems to obtain adequate strength of the bone-implant construct as well as sufficient purchase for screws in the weak bone. One way to address this increasing problem is through the development of new metal implants specifically designed for fixation of fractures in osteopenic bone. An alternative strategy is to develop methods for augmentation of the weak bone that surrounds the metal implant. In most instances augmentation is achieved by using injectable cement to reinforce the bone. Conventional PMMA provides good strength but due to several drawbacks it has never gained general acceptance for fracture augmentation. More recently several injectable cements based on calcium-phosphate, calcium-sulphate or bioglass has been developed for augmentation of fractures in the extremities as well as for vertebral compressive fractures in the spine. On the basis of biomechanical studies and the clinical experience so far, cement augmentation will enable faster rehabilitation, as the strength of the cement makes it possible to allow full weight-bearing earlier than conventional metal implants alone. More clinical studies are needed in order to refine the surgical technique, develop cement types aimed for fracture treatment and define the most appropriate indications and limitations of augmentation for fracture repair. The purpose of this article is to review the possible use of augmentation as a technique in the treatment of fractures in the extremities as well as in the spine.
Collapse
Affiliation(s)
- S Larsson
- Department of Orthopedics, Uppsala University Hospital, Uppsala, Sweden.
| |
Collapse
|
231
|
Hamadouche M. [Clinical evaluation tools of total hip arthroplasties]. ACTA ACUST UNITED AC 2006; 92:581-9. [PMID: 17088755 DOI: 10.1016/s0035-1040(06)75916-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Total hip arthroplasty is one of the most efficient hip surgery procedures enabling improved function in the vast majority of operated patients. The major long-term complication is aseptic loosening due to an inflammatory response to particle wear debris coming from the bearings. Polyethylene is the key culprit. Currently two solutions are proposed: eliminating polyethylene from the prosthetic articulation or reducing material wear. This leads to the need for reliable tools for evaluating short-term results, predictive of long-term outcome. When the innovation concerns reduction of polyethylene wear, short-term wear should be measured with software methods or radiostereometry. If the innovation concerns improvement of polyethyleneless implants, then short-term migration should be measured with EBRA or radiostereometry. In addition, the long-term retrospective evaluation of large series of patients remains of major interest provided that it is performed with survival analysis. These different methods are detailed in this study, indicating the pros and cons for each solution.
Collapse
Affiliation(s)
- M Hamadouche
- Centre de Recherches Orthopédiques Cliniques, CHU Cochin Port-Royal (AP-HP), Université Paris V, 27 rue du Faubourg-Saint-Jacques, 75014 Paris.
| |
Collapse
|
232
|
Isberg J, Faxén E, Brandsson S, Eriksson BI, Kärrholm J, Karlsson J. Early active extension after anterior cruciate ligament reconstruction does not result in increased laxity of the knee. Knee Surg Sports Traumatol Arthrosc 2006; 14:1108-15. [PMID: 16955299 DOI: 10.1007/s00167-006-0138-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2005] [Accepted: 03/13/2006] [Indexed: 01/28/2023]
Abstract
If permission of full active and passive extension immediately after an anterior cruciate ligament (ACL) reconstruction will increase the post-operative laxity of the knee has been a subject of discussion. We investigated whether a post-operative rehabilitation protocol including active and passive extension without any restrictions in extension immediately after an ACL reconstruction would increase the post-operative anterior-posterior knee laxity (A-P laxity). Our hypothesis was that full active and passive extension immediately after an ACL reconstruction would have no effect on the A-P laxity and clinical results up to 2 years after the operation. Twenty-two consecutive patients (14 men, 8 women, median age 21 years, range 17-41) were included. All the patients had a unilateral ACL rupture and no other ligament injuries or any other history of previous knee injuries. The surgical procedure was identical in all patients and one experienced surgeon operated on all the patients, using the bone-patellar tendon-bone autograft. The post-operative rehabilitation programme was identical in both groups, except for extension training during the first 4 weeks post-operatively. The patients were randomly allocated to post-operative rehabilitation programmes either allowing (Group A, n=11) or not allowing [Group B (30 to -10 degrees ), n=11] full active and passive extension immediately after the operation. They were evaluated pre-operatively and at 6 months and 2 years after the reconstruction. To evaluate the A-P knee laxity, radiostereometric analysis (RSA) and KT-1000 arthrometer (KT-1000) measurements were used, range of motion, Lysholm score, Tegner activity level, the International Knee Documentation Committee (IKDC) evaluation system and one-leg-hop test quotient were used. Pre-operatively, the RSA measurements revealed side-to-side differences in Group A of 8.6 mm (2.3-15.4), median (range) and in Group B of 7.2 mm (2.2-17.4) (n.s.). The corresponding KT-1000 values were for Group A, 2.0 mm (0-8.0) and Group B, 4.0 mm (0-10.0) (n.s.). At 2 years, the differences between the two groups were minimal, regardless of the method that had been used. The RSA measurements in Group A were 2.7 mm (0-10.7) and in Group B 2.8 (-1.8 to 9.5). The KT-1000 values were for Group A, 1.0 mm (-1.5 to 3.5), and for Group B, 0.5 mm (-1.0 to 4.0), without any significant differences between the groups. Nor did the Lysholm score, Tegner activity level, IKDC or one-leg-hop test differ. Early active and passive extension training, without any restrictions in extension, immediately after an ACL reconstruction using bone-patellar tendon-bone graft did not increase post-operative knee laxity up to 2 years after the ACL reconstruction.
Collapse
Affiliation(s)
- Jonas Isberg
- Department of Orthopaedics, Sahlgrenska University Hospital, 416 85 Goteborg, Sweden.
| | | | | | | | | | | |
Collapse
|
233
|
Madanat R, Moritz N, Aro HT. Three-dimensional computer simulation of radiostereometric analysis (RSA) in distal radius fractures. J Biomech 2006; 40:1855-61. [PMID: 17034797 DOI: 10.1016/j.jbiomech.2006.07.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2006] [Accepted: 07/20/2006] [Indexed: 10/24/2022]
Abstract
Physical phantom models have conventionally been used to determine the accuracy and precision of radiostereometric analysis (RSA) in various orthopaedic applications. Using a phantom model of a fracture of the distal radius it has previously been shown that RSA is a highly accurate and precise method for measuring both translation and rotation in three-dimensions (3-D). The main shortcoming of a physical phantom model is its inability to mimic complex 3-D motion. The goal of this study was to create a realistic computer model for preoperative planning of RSA studies and to test the accuracy of RSA in measuring complex movements in fractures of the distal radius using this new model. The 3-D computer model was created from a set of tomographic scans. The simulation of the radiographic imaging was performed using ray-tracing software (POV-Ray). RSA measurements were performed according to standard protocol. Using a two-part fracture model (AO/ASIF type A2), it was found that for simple movements in one axis, translations in the range of 25microm-2mm could be measured with an accuracy of +/-2microm. Rotations ranging from 16 degrees to 2 degrees could be measured with an accuracy of +/-0.015 degrees . Using a three-part fracture model the corresponding values of accuracy were found to be +/-4microm and +/-0.031 degrees for translation and rotation, respectively. For complex 3-D motion in a three-part fracture model (AO/ASIF type C1) the accuracy was +/-6microm for translation and +/-0.120 degrees for rotation. The use of 3-D computer modelling can provide a method for preoperative planning of RSA studies in complex fractures of the distal radius and in other clinical situations in which the RSA method is applicable.
Collapse
Affiliation(s)
- Rami Madanat
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, University of Turku, Turku, Finland
| | | | | |
Collapse
|
234
|
Ornstein E, Franzén H, Johnsson R, Stefánsdóttir A, Sundberg M, Tägil M. Five-year follow-up of socket movements and loosening after revision with impacted morselized allograft bone and cement: a radiostereometric and radiographic analysis. J Arthroplasty 2006; 21:975-84. [PMID: 17027539 DOI: 10.1016/j.arth.2005.11.009] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2001] [Revised: 10/28/2005] [Accepted: 11/02/2005] [Indexed: 02/01/2023] Open
Abstract
In 1999, we reported on the 2-year results of a series of 21 first-time socket revisions using impacted morselized allograft bone. Seven still migrated between 1.5 and 2 years. Seventeen remained for the current 5-year follow-up. No socket had been rerevised. Five sockets showed signs of radiographic loosening. These 5 cases also exhibited radiographic signs of allograft resorption as well as high rates of socket migration and rotation as measured by radiostereometric analysis. Of the 6 remaining sockets that had migrated between 1.5 and 2 years, 3 stabilized and 3 were among those with signs of radiographic loosening. Fifteen patients (15 hips) revealed pain reduction at the 5-year follow-up. Three had slight pain on walking that disappeared immediately at rest (pain score 4). All the others revealed either no pain (pain score 6) or slight pain that disappeared with activity (pain score 5). No pattern of early socket migration according to radiostereometric analysis could be identified, predicting later socket migration or loosening. The rate of cases with signs of radiographic loosening (29%, 5/17) was comparable to that reported by the Nijmegen group but the follow-up was shorter in the current study. The rate of cases with signs of radiographic loosening was comparable to both conventionally cemented socket revisions and cementless revisions. The future will show if further sockets loosen and if the loose sockets up to date will end up in rerevisions.
Collapse
Affiliation(s)
- Ewald Ornstein
- Department of Orthopedics, Hässleholm-Kristianstad County Hospital, Hässleholm, Sweden
| | | | | | | | | | | |
Collapse
|
235
|
Leardini A, Belvedere C, Astolfi L, Fantozzi S, Viceconti M, Taddei F, Ensini A, Benedetti MG, Catani F. A new software tool for 3D motion analyses of the musculo-skeletal system. Clin Biomech (Bristol, Avon) 2006; 21:870-9. [PMID: 16684581 DOI: 10.1016/j.clinbiomech.2006.03.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2005] [Revised: 02/10/2006] [Accepted: 03/15/2006] [Indexed: 02/07/2023]
Abstract
BACKGROUND Many clinical and biomechanical research studies, particularly in orthopaedics, nowadays involve forms of movement analysis. Gait analysis, video-fluoroscopy of joint replacement, pre-operative planning, surgical navigation, and standard radiostereometry would require tools for easy access to three-dimensional graphical representations of rigid segment motion. Relevant data from this variety of sources need to be organised in structured forms. Registration, integration, and synchronisation of segment position data are additional necessities. With this aim, the present work exploits the features of a software tool recently developed within a EU-funded project ('Multimod') in a series of different research studies. METHODS Standard and advanced gait analysis on a normal subject, in vivo fluoroscopy-based three-dimensional motion of a replaced knee joint, patellar and ligament tracking on a knee specimen by a surgical navigation system, stem-to-femur migration pattern on a patient operated on total hip replacement, were analysed with standard techniques and all represented by this innovative software tool. Segment pose data were eventually obtained from these different techniques, and were successfully imported and organised in a hierarchical tree within the tool. FINDINGS Skeletal bony segments, prosthesis component models and ligament links were registered successfully to corresponding marker position data for effective three-dimensional animations. These were shown in various combinations, in different views, from different perspectives, according to possible specific research interests. INTERPRETATION Bioengineering and medical professionals would be much facilitated in the interpretation of the motion analysis measurements necessary in their research fields, and would benefit therefore from this software tool.
Collapse
Affiliation(s)
- A Leardini
- Movement Analysis Laboratory, Istituti Ortopedici Rizzoli, 40139 Bologna, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
236
|
Nuttall D, Haines JF, Trail II. A study of the micromovement of pegged and keeled glenoid components compared using radiostereometric analysis. J Shoulder Elbow Surg 2006; 16:S65-70. [PMID: 17493557 DOI: 10.1016/j.jse.2006.01.015] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2005] [Accepted: 01/20/2006] [Indexed: 02/01/2023]
Abstract
In a prospective, randomized study between 2000 and 2004, 20 patients with primary osteoarthritis of the shoulder had a total shoulder arthroplasty with radiostereometric analysis, 10 with keeled and 10 with pegged glenoid components. The relative movement of the glenoid component with respect to the scapula was measured over a 24-month period. Three keeled and five pegged glenoids needed reaming for erosion. The largest translations occurred along the longitudinal axis (mean of 1.35 mm for keeled eroded components) (P = .017 for keeled vs pegged components and P = .013 for eroded vs non-eroded components). Both of the other translation axes showed no significant differences. The highest maximum total point movement at 24 months was 2.57 mm for keeled eroded components and 1.64 mm for pegged eroded components (P = .029 for keeled vs pegged components and P = .023 for eroded vs non-eroded components). The largest rotation was anteversion, with mean values of 5.5 degrees for keeled eroded components and 4.8 degrees for pegged eroded components (P = .658 for keeled vs pegged components and P = .90 for eroded vs non-eroded components). The mean varus tilt was 4.5 degrees for keeled eroded components compared with 2.3 degrees for pegged eroded components (P = .004 for keeled vs pegged components and P = .016 for eroded vs non-eroded components), and finally, anterior-posterior rotation mean values were 3.5 degrees for keeled eroded components and 1.1 degrees for pegged eroded components (P = .022 for keeled vs pegged components and P = .04 for eroded vs non-eroded components). In conclusion, whereas all components moved, radiostereometric analysis revealed increased migration with keeled components, exacerbated by glenoid erosion. Furthermore, a distinctive pattern of migration was identified over the 2-year period.
Collapse
Affiliation(s)
- David Nuttall
- Hand and Upper Limb Research Unit, Wrightington Hospital, Appley Bridge, Wigan, England
| | | | | |
Collapse
|
237
|
Koning OHJ, Oudegeest OR, Valstar ER, Garling EH, van der Linden E, Hinnen JW, Hamming JF, Vossepoel AM, van Bockel JH. Roentgen Stereophotogrammetric Analysis: An Accurate Tool to Assess Stent-Graft Migration. J Endovasc Ther 2006; 13:468-75. [PMID: 16928160 DOI: 10.1583/06-1842mr.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
PURPOSE To evaluate in an in vitro model the feasibility and accuracy of Roentgen stereophotogrammetric analysis (RSA) versus computed tomography (CT) for the ability to detect stent-graft migration. METHODS An aortic model was constructed from a 22-mm-diameter Plexiglas tube with 6-mm polytetrafluoroethylene inlays to mimic the renal arteries. Six tantalum markers were placed in the wall of the aortic tube proximal to the renal arteries. Another 6 markers were added to a Gianturco stent, which was cast in Plexiglas and placed inside the aorta and fixed to a micromanipulator to precisely control displacement of the stent along the longitudinal axis. Sixteen migrations were analyzed with RSA software and compared to the micromanipulator. Thirty-two migrations were measured by 3 observers from CT images acquired with 16x0.5-mm beam collimation and reconstructed with a 0.5-mm slice thickness and a 0.4-mm reconstruction interval. Measurements were made with Vitrea postprocessing software using a standard clinical protocol and central lumen line reconstruction. Results of CT were also compared to the micromanipulator. RESULTS The mean RSA measurement error compared to the micromanipulator was 0.002+/-0.044 mm, and the maximum error was 0.10 mm. There was no statistically significant interobserver variability for CT (p=0.17). The pooled mean (maximum) measurement error of CT was 0.14+/-0.29 (1.00) mm, which was significantly different from the RSA measurement error (p<0.0001). CONCLUSION Detection of endograft migration by RSA is feasible and was significantly more accurate than CT in this nonpulsatile in vitro model.
Collapse
Affiliation(s)
- Olivier H J Koning
- Department of Surgery, Division of Vascular Surgery, Leiden University Medical Center, Leiden, The Netherlands.
| | | | | | | | | | | | | | | | | |
Collapse
|
238
|
von Schewelov T, Carlsson A, Dahlberg L. Cross-linked N-telopeptide of type I collagen (NTx) in urine as a predictor of periprosthetic osteolysis. J Orthop Res 2006; 24:1342-8. [PMID: 16718682 DOI: 10.1002/jor.20152] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Periprosthetic osteolysis is often nonsymptomatic and hard to visualize by conventional radiography. Cross-linked N-telopeptide of type I collagen (NTx), a marker of osteoclast mediated bone resorption, has been suggested to evaluate local particulate-induced osteolysis in patients operated on with a total hip prosthesis. Urine specimens were sampled after hip joint replacement in 160 patients. NTx was analyzed by a commercially available ELISA kit. Osteolysis was identified in the acetabulum and confirmed at operation. Using analysis of covariance to correct for differences in age, gender, and time after operation, NTx (mean SD) was 36+/-12 BCE/nM creatinine in patients with osteolysis (n=33) and 27+/-13 BCE/nM creatinine in patients without osteolysis (n=127) (p=0.003). Eighteen hips of 38 (47%), demonstrating an annual wear of more than 0.2 mm and an NTx value above 29 BCE/nM creatinine, had been revised due to osteolysis. The osteolysis prevalence in this group was increased 10 times (CI 4-23, p<0.05). Indeed, NTx release and annual wear were both associated with increased prevalence of osteolysis, however, independently of each other. NTx seems a feasible marker of periprosthetic osteolysis. A preoperative baseline NTx level is likely needed for its use as a predictor of periprosthetic osteolysis in individual cases.
Collapse
Affiliation(s)
- Thord von Schewelov
- Department of Orthopedics, Lund University, Malmö University Hospital, SE-205 02 Malmö, Sweden.
| | | | | |
Collapse
|
239
|
Kaptein BL, Valstar ER, Spoor CW, Stoel BC, Rozing PM. Model-based RSA of a femoral hip stem using surface and geometrical shape models. Clin Orthop Relat Res 2006; 448:92-7. [PMID: 16826102 DOI: 10.1097/01.blo.0000224010.04551.14] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Roentgen stereophotogrammetry (RSA) is a highly accurate three-dimensional measuring technique for assessing micromotion of orthopaedic implants. A drawback is that markers have to be attached to the implant. Model-based techniques have been developed to prevent using special marked implants. We compared two model-based RSA methods with standard marker-based RSA techniques. The first model-based RSA method used surface models, and the second method used elementary geometrical shape (EGS) models. We used a commercially available stem to perform experiments with a phantom as well as reanalysis of patient RSA radiographs. The data from the phantom experiment indicated the accuracy and precision of the elementary geometrical shape model-based RSA method is equal to marker-based RSA. For model-based RSA using surface models, the accuracy is equal to the accuracy of marker-based RSA, but its precision is worse. We found no difference in accuracy and precision between the two model-based RSA techniques in clinical data. For this particular hip stem, EGS model-based RSA is a good alternative for marker-based RSA.
Collapse
Affiliation(s)
- Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, The Netherlands.
| | | | | | | | | |
Collapse
|
240
|
Khan RJK, Fick D, Alakeson R, Haebich S, de Cruz M, Nivbrant B, Wood D. A constrained acetabular component for recurrent dislocation. ACTA ACUST UNITED AC 2006; 88:870-6. [PMID: 16798987 DOI: 10.1302/0301-620x.88b7.17644] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis. The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were four acetabular revisions, three for aseptic loosening and one for deep infection. Another acetabular component was radiologically loose with progressive radiolucent lines in all Gruen zones and was awaiting revision. The overall rate of aseptic loosening was 11.8% (4 of 34). Roentgen stereophotogrammetric analysis in the non-revised components confirmed migration of up to 1.06 mm of translation and 2.32° of rotation at 24 months. There was one case of dislocation and dissociation of the component in the same patient. Of the 34 patients, 33 (97.1%) had no further episodes of dislocation. The constrained acetabular component reported in our study was effective in all but one patient with instability of the hip, but the rate of aseptic loosening was higher than has been reported previously and requires further investigation.
Collapse
Affiliation(s)
- R J K Khan
- University of Western Australia, Nedlands, Perth 6009, Western Australia.
| | | | | | | | | | | | | |
Collapse
|
241
|
Abstract
Roentgen stereophotogrammetry allows one to localize the position of an object in space using roentgen rays. For orthopaedic purposes it was developed 35 years ago by Göran Selvik, and since that time many investigators have refined the radiostereometric calculations and evaluative software. Many uses and mathematical algorithms have been developed, and advancements in computer programs and digital radiography continue to expand its capabilities. Despite these advances, improvements in the technical accuracy and type of kinematic analyses possible have been relatively modest. However, radiostereometric analysis is now easier and less time consuming to use, with a resolution in clinical practice almost equal to what could only previously be obtained under ideal laboratory conditions. The ability to measure skeletal and implant movements with high resolution in vivo images was an important progressive step for the orthopaedic community. Radiostereometric analysis has helped develop new fields in clinical orthopaedic research and continues to improve advancements in orthopaedic health care.
Collapse
Affiliation(s)
- Johan Kärrholm
- Department of Orthopaedics, Sahlgrenska University Hospital, Göteborg, Sweden.
| | | | | |
Collapse
|
242
|
Abstract
UNLABELLED Mobile bearings were introduced to improve wear and knee kinematics. By uncoupling the forces generated at the articulation from the implant-bone interface this would, theoretically, also improve the fixation of the implant to bone. We did this study to evaluate whether mobile bearings improve the fixation of the tibial component to bone. Fifty-two consecutive knees in 47 patients (average age, 72 years; range, 62-84 years) with primary osteoarthrosis were randomized into two groups to receive a cemented total knee arthroplasty with either a fixed-bearing or mobile-bearing tibial component. The quality of fixation was analyzed with radiostereometric analysis for up to 2 years. Mobile bearings did not improve fixation. Both magnitudes and directions of component rotations were similar, and the number of implants with continuous migration was almost identical. Both implant types had a combination of subsidence and lift-off, but where the mobile bearing implants displayed more of subsidence, the fixed bearing knees showed more lift-off. It might be that the somewhat stiffer cobalt-chromium baseplate or the different joint conformity used in the mobile-bearing knees counteracts any potential effects of the mobile bearing. LEVEL OF EVIDENCE Therapeutic Level I. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Anders Henricson
- Department of Orthopaedics, Falu General Hospital, Falun, Sweden
| | | | | |
Collapse
|
243
|
Nilsson KG, Henricson A, Norgren B, Dalén T. Uncemented HA-coated implant is the optimum fixation for TKA in the young patient. Clin Orthop Relat Res 2006; 448:129-39. [PMID: 16826107 DOI: 10.1097/01.blo.0000224003.33260.74] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
UNLABELLED Fixation of the tibial component in total knee arthroplasty in younger patients remains controversial. We evaluate the results of three different types of fixation of the Profix total knee arthroplasty in a randomized controlled trial of 97 consecutive knees (85 patients) with osteoarthrosis or inflammatory arthritis with 2-year followup of all patients. We randomized patients to three different types of fixation of the tibial component: cemented, uncemented (HA coated) with screws, or uncemented (HA coated) without screws. We performed clinical evaluations and radiostereometric analysis at 6 weeks, and 3, 6, 12 and 24 months postoperatively. The knees in the uncemented groups migrated more than those in the cemented group during the first 3 months, but at 2 years we observed no differences. The uncemented implants displayed all migration within the first 3 months. The cemented implants did not stabilize but had continuously increasing migration during the followup. Cementless implants without screws did not migrate more than implants with screws and displayed similar pattern of migration, indicating screws do not improve fixation. Uncemented fixation using hydroxyapatite-coated implants without screws seems to be the best solution for the younger patient. LEVEL OF EVIDENCE Therapeutic Level I. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Kjell G Nilsson
- Department of Orthopaedics, Umeå University Hospital, Sweden.
| | | | | | | |
Collapse
|
244
|
Bragonzoni L, Russo A, Girolami M, Albisinni U, Visani A, Mazzotti N, Marcacci M. The distal tibiofibular syndesmosis during passive foot flexion. RSA-based study on intact, ligament injured and screw fixed cadaver specimens. Arch Orthop Trauma Surg 2006; 126:304-8. [PMID: 16568290 DOI: 10.1007/s00402-006-0131-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2004] [Indexed: 10/24/2022]
Abstract
INTRODUCTION The aim of the study was to investigate the kinematics of the distal tibiofibular syndesmosis in intact and ligament injured ankles and to assess how effective is the syndesmotic screw in restraining mortise width variations during passive foot flexion. MATERIALS AND METHODS The trials were carried out on seven fresh frozen cadaver specimens. The distal tibiofibular syndesmosis widening was investigated using Roentgen stereophotogrammetric analysis, in intact and ligament injured ankles and after the fixation of the syndesmotic screw. The AO-ASIF recommendations were followed for screw implant. RESULTS Injury to the syndesmotic and deltoid ligaments of the ankle did not result in a significant variation of the syndesmosis behavior during passive foot flexion. The 4.5-mm diameter cortical screw used in this study proved effective in restraining mortise width variation during foot flexion. The recorded mortise widening in the flexion arc extending from the neutral to the maximally dorsiflexed position was negligible in intact and ligament injured joints. CONCLUSION The result does not endorse the recommendation of placing the foot in full dorsal flexion during screw implantation. The choice of screw fixation as a treatment for ankle syndesmosis disruption should be carefully evaluated.
Collapse
Affiliation(s)
- Laura Bragonzoni
- Biomechanics Laboratory, Centro di Ricerca Codivilla-Putti, Istituti Ortopedici Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy.
| | | | | | | | | | | | | |
Collapse
|
245
|
|
246
|
Rahme H, Mattsson P, Wikblad L, Larsson S. Cement and press-fit humeral stem fixation provides similar results in rheumatoid patients. Clin Orthop Relat Res 2006; 448:28-32. [PMID: 16826092 DOI: 10.1097/01.blo.0000224007.25636.85] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
UNLABELLED It is unclear whether humeral stems should be fixed with or without cement. We question whether press-fit fixation would provide similar results to cemented stem fixation. We prospectively randomized 26 shoulders in 24 patients with rheumatoid arthritis (20 women, 4 men) to have either a cemented or press-fit stem. In the press-fit group, stems were matched to the medullary canal, while lavage, pressurizing and distal plugging were used in the cemented group. We followed patients with conventional radiographs and radiostereometric analysis (RSA) at 5 to 7 days, 4 months, 1 year, and 2 years after surgery. One patient died from unrelated causes before the 1-year followup, while the remaining patients were followed according to the protocol. All but two patients were very satisfied or satisfied at 2 years. No stem was radiographically loose. There was no difference in micromotion between groups. The average rotation for all axes was less than 0.25 degrees for both groups and the average translation was less than 0.32 mm for all three axes including subsidence, which was less than 0.1 mm for the uncemented stems. We concluded at 2 years these stems provided similar fixation in rheumatoid shoulders. LEVEL OF EVIDENCE Therapeutic Level I. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Hans Rahme
- Department of Orthopedics, Uppsala University Hospital, Sweden.
| | | | | | | |
Collapse
|
247
|
Flivik G, Kristiansson I, Kesteris U, Ryd L. Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study. Clin Orthop Relat Res 2006; 448:164-72. [PMID: 16826112 DOI: 10.1097/01.blo.0000203479.27044.d3] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
UNLABELLED There is uncertainty regarding whether and how the subchondral bone plate should be treated during acetabular preparation for cemented cup fixation in a total hip arthroplasty. We hypothesized that removing the bone plate would improve the cement-bone interface without jeopardizing the initial cup stability, and therefore, be advantageous to long-term cup survival. We randomized 50 patients with primary osteoarthritis into two groups, one for removal and one for retention of the subchondral bone plate. The patients were evaluated during 2 years followup using repeated radiostereometric examinations, analyses of radiolucent lines, and clinical followups. Patient scoring was done using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12, and the Harris hip score. Removal of the subchondral bone plate resulted in a superior cement-bone interface with less development of radiolucent lines. The radiostereometry results showed small migrations in both groups. We found no differences in cup stability between groups, although a difference was observed in rotational behavior with the removal group stabilizing in a slightly vertical position whereas the retention group showed slight but progressive rotation into a more horizontal position. No differences were found during clinical followups. Removing the subchondral bone plate, where possible, improves the cement-bone interface without jeopardizing the stability, implying better long-term cup survival. However, it is a more demanding surgical technique. LEVEL OF EVIDENCE Therapeutic study, Level I (high quality randomized controlled trial with statistically significant difference or no statistically significant difference but narrow confidence intervals). See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Gunnar Flivik
- Department of Orthopedics, Lund University Hospital, Sweden.
| | | | | | | |
Collapse
|
248
|
Isberg J, Faxèn E, Brandsson S, Eriksson BI, Kärrholm J, Karlsson J. KT-1000 records smaller side-to-side differences than radiostereometric analysis before and after an ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 2006; 14:529-35. [PMID: 16607565 DOI: 10.1007/s00167-006-0061-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2005] [Accepted: 08/26/2005] [Indexed: 10/24/2022]
Abstract
The KT-1000 and similar non-invasive arthrometers are used as a complement to clinical examination in the diagnosis of anterior cruciate ligament (ACL) rupture and during the follow-up after surgery. We compared the two methods, KT-1000 and Radiostereometric analysis (RSA), when used to measure anterior-posterior knee laxity (A-P laxity) in patients with ACL rupture, before and after the reconstruction of this ligament, in a prospective, comparative study. Twenty-two consecutive patients (14 men, 8 women) with a median age of 24 years (range 16-41) were studied. All the patients had a unilateral ACL rupture and an intact contralateral knee. The patients were operated on by one experienced surgeon using the bone-patellar tendon-bone (BTB) autograft. Preoperatively and 2 years after the reconstruction, all the patients were evaluated using KT-1000 and RSA measurements of A-P laxity. The side-to-side differences between the injured and the intact knees, that is, total A-P laxity for both knees, are presented. Preoperatively, the median side-to-side differences using the two methods (KT-1000/RSA) were 4.0 (0-10)/7.4 mm (2.2-17.4) (P<0.0001). The total A-P laxity on the injured side was 11.0 (6.0-18.0)/10.9 mm (6.2-19.6) (n.s), while it was 8.0 (6.0-10.0)/3.1 mm (0.2-8.6) on the intact side (P<0.0001). A side-to-side difference of more than 3.0 mm was defined as the cut-off value for indicating ACL rupture. Using the KT-1000, 11 of 22 (50%) patients had a cut-off value above 3.0 mm, while the corresponding figure for RSA was 21/22 (95%) patients. At the 2-year follow-up, the median side-to-side differences using the two methods (KT-1000/RSA) were 0.5 (-1.5 to 4.0)/2.8 mm (-1.8 to 10.7) (P<0.0001). The total A-P laxity on the operated side was 9.5 (7.5-14.0)/6.5 mm (2.4-14.1) (P<0.0001). We conclude that the KT-1000 recorded significantly smaller side-to-side differences than did the RSA, both before and after the reconstruction of the ACL using a BTB autograft. Before it was mainly an effect of larger A-P laxity recordings with KT-1000 on the intact side, and after the reconstruction, the KT-1000 still recorded larger A-P laxity on the intact side and also larger A-P laxity on the reconstructed side than RSA.
Collapse
Affiliation(s)
- Jonas Isberg
- Department of Orthopaedics, Sahlgrenska University Hospital, Göteborg University, 41685, Göteborg, Sweden.
| | | | | | | | | | | |
Collapse
|
249
|
Sundfeldt M, Carlsson LV, Johansson CB, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop 2006; 77:177-97. [PMID: 16752278 DOI: 10.1080/17453670610045902] [Citation(s) in RCA: 392] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Today, aseptic loosening is the most common cause of revision of major arthroplasties. Aseptic loosening accounts for more than two-thirds of hip revisions and almost one-half of knee revisions in Sweden. Several theories on the cause of aseptic loosening have been proposed. Most of these theories, however, are based on empiric observations, experimental animal models or anecdotal cases. In this review, we discuss the most common theories concerning aseptic loosening. It emerges from this review that aseptic loosening has a multifactorial etiology and cannot be explained by a single theory.
Collapse
Affiliation(s)
- Mikael Sundfeldt
- Department of Biomaterials/Handicap Research, Sahlgrenska University Hospital, University of Gothenburg, Sweden.
| | | | | | | | | |
Collapse
|
250
|
Carlsson LV, Albrektsson BEJ, Regnér LR. Minimally invasive surgery vs conventional exposure using the Miller-Galante unicompartmental knee arthroplasty: a randomized radiostereometric study. J Arthroplasty 2006; 21:151-6. [PMID: 16520199 DOI: 10.1016/j.arth.2005.06.014] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2004] [Revised: 02/27/2005] [Accepted: 06/05/2005] [Indexed: 02/01/2023] Open
Abstract
Forty-one patients were randomized to a cemented Miller-Galante unicompartmental (Zimmer, Warsaw, Ind) knee arthroplasty inserted with either minimally invasive surgery or with a standard exposure. Clinical data and conventional radiographs were recorded and patients were followed with radiostereometric analysis to measure migration rate of the tibial component. The rehabilitation of patients operated through a small incision was faster, and there was a significant difference in days of hospitalization (P = .03). No statistical significant difference was found between the 2 groups regarding clinical or radiographic data. The Hospital for Special Surgery score was 96 and 92, respectively, for the minimally invasive surgery and conventional group at 2 years. The limb alignment was equal in both groups with a mean femorotibial axis of 182 degrees after surgery. The rate of migration for tibial components was very small, with a maximal total point motion of 0.8 mm for both groups after 2 years follow-up.
Collapse
Affiliation(s)
- Lars V Carlsson
- Department of Orthopaedics, Sahlgrenska University Hospital/Sahlgrenska, Gothenburg, Sweden
| | | | | |
Collapse
|