301
|
Rezk AR, Qi A, Friend JR, Li WH, Yeo LY. Uniform mixing in paper-based microfluidic systems using surface acoustic waves. LAB ON A CHIP 2012; 12:773-9. [PMID: 22193520 DOI: 10.1039/c2lc21065g] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Paper-based microfluidics has recently received considerable interest due to their ease and low cost, making them extremely attractive as point-of-care diagnostic devices. The incorporation of basic fluid actuation and manipulation schemes on paper substrates, however, afford the possibility to extend the functionality of this simple technology to a much wider range of typical lab-on-a-chip operations, given its considerable advantages in terms of cost, size and integrability over conventional microfluidic substrates. We present a convective actuation mechanism in a simple paper-based microfluidic device using surface acoustic waves to drive mixing. Employing a Y-channel structure patterned onto paper, the mixing induced by the 30 MHz acoustic waves is shown to be consistent and rapid, overcoming several limitations associated with its capillary-driven passive mixing counterpart wherein irreproducibilities and nonuniformities are often encountered in the mixing along the channel--capillary-driven passive mixing offers only poor control, is strongly dependent on the paper's texture and fibre alignment, and permits backflow, all due to the scale of the fibres being significant in comparison to the length scales of the features in a microfluidic system. Using a novel hue-based colourimetric technique, the mixing speed and efficiency is compared between the two methods, and used to assess the effects of changing the input power, channel tortuousity and fibre/flow alignment for the acoustically-driven mixing. The hue-based technique offers several advantages over grayscale pixel intensity analysis techniques in facilitating quantification without limitations on the colour contrast of the samples, and can be used, for example, for quantification in on-chip immunochromatographic assays.
Collapse
Affiliation(s)
- Amgad R Rezk
- Micro/Nanophysics Research Laboratory, School of Electrical & Computer Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | | | | | | | | |
Collapse
|
302
|
Najah M, Griffiths AD, Ryckelynck M. Teaching single-cell digital analysis using droplet-based microfluidics. Anal Chem 2012; 84:1202-9. [PMID: 22229495 DOI: 10.1021/ac202645m] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Microfluidics allows the manipulation of small quantities of reagents in a high-throughput manner and is therefore highly amenable to single cell characterization and more generally to digital analysis, with applications in fields as varied as genomics, diagnostics, directed evolution, and drug screening. The growing place of microfluidics in biology laboratories encouraged us to develop a teaching method where advanced undergraduate or first-year graduate-level students are taught to fabricate droplet-based microfluidic devices, characterize them, and finally use them to perform a digital analysis of bacterial samples based on a phenotypic marker.
Collapse
Affiliation(s)
- Majdi Najah
- Institut de Science et d'Ingénierie Supramoléculaires (ISIS), Université de Strasbourg, CNRS UMR 7006, 8 allée Gaspard Monge, 67083 Strasbourg Cedex, France
| | | | | |
Collapse
|
303
|
Gubala V, Harris LF, Ricco AJ, Tan MX, Williams DE. Point of Care Diagnostics: Status and Future. Anal Chem 2011; 84:487-515. [DOI: 10.1021/ac2030199] [Citation(s) in RCA: 832] [Impact Index Per Article: 64.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Vladimir Gubala
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Leanne F. Harris
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Antonio J. Ricco
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Ming X. Tan
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - David E. Williams
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| |
Collapse
|
304
|
Orloff ND, Dennis JR, Cecchini M, Schonbrun E, Rocas E, Wang Y, Novotny D, Simmonds RW, Moreland J, Takeuchi I, Booth JC. Manipulating particle trajectories with phase-control in surface acoustic wave microfluidics. BIOMICROFLUIDICS 2011; 5:44107-441079. [PMID: 22662059 PMCID: PMC3364806 DOI: 10.1063/1.3661129] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2011] [Accepted: 10/27/2011] [Indexed: 05/05/2023]
Abstract
We present a 91 MHz surface acoustic wave resonator with integrated microfluidics that includes a flow focus, an expansion region, and a binning region in order to manipulate particle trajectories. We demonstrate the ability to change the position of the acoustic nodes by varying the electronic phase of one of the transducers relative to the other in a pseudo-static manner. The measurements were performed at room temperature with 3 μm diameter latex beads dispersed in a water-based solution. We demonstrate the dependence of nodal position on pseudo-static phase and show simultaneous control of 9 bead streams with spatial control of -0.058 μm/deg ± 0.001 μm/deg. As a consequence of changing the position of bead streams perpendicular to their flow direction, we also show that the integrated acoustic-microfluidic device can be used to change the trajectory of a bead stream towards a selected bin with an angular control of 0.008 deg/deg ± 0.000(2) deg/deg.
Collapse
|
305
|
Che Z, Nguyen NT, Wong TN. Analysis of chaotic mixing in plugs moving in meandering microchannels. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2011; 84:066309. [PMID: 22304192 DOI: 10.1103/physreve.84.066309] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2011] [Indexed: 05/31/2023]
Abstract
Droplets moving in meandering microchannels can serve as a passive and robust strategy to produce chaotic mixing of species in droplet-based microfluidics. In this paper, a simplified theoretical model is proposed for plug-shaped droplets moving in meandering microchannels at Stokes flow. With this model to provide the velocity field, particle tracking, which requires a large computation time, is performed directly and easily without interpolation. With this convenience, a broad survey of the parameter space is carried out to investigate chaotic mixing in plugs, including the channel curvature, the Peclet number, the viscosity ratio, and the plug length. The results show that in order to achieve rapid mixing in plugs in meandering microchannels, a large curvature, a small Peclet number, a moderate viscosity ratio, and a moderate plug length are preferred.
Collapse
Affiliation(s)
- Zhizhao Che
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
| | | | | |
Collapse
|
306
|
Meng L, Cai F, Zhang Z, Niu L, Jin Q, Yan F, Wu J, Wang Z, Zheng H. Transportation of single cell and microbubbles by phase-shift introduced to standing leaky surface acoustic waves. BIOMICROFLUIDICS 2011; 5:44104-4410410. [PMID: 22662056 PMCID: PMC3364803 DOI: 10.1063/1.3652872] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Accepted: 09/27/2011] [Indexed: 05/04/2023]
Abstract
A microfluidic device was developed to precisely transport a single cell or multiple microbubbles by introducing phase-shifts to a standing leaky surface acoustic wave (SLSAW). The device consists of a polydimethyl-siloxane (PDMS) microchannel and two phase-tunable interdigital transducers (IDTs) for the generation of the relative phase for the pair of surface acoustic waves (SAW) propagating along the opposite directions forming a standing wave. When the SAW contacts the fluid medium inside the microchannel, some of SAW energy is coupled to the fluid and the SAW becomes the leaky surface wave. By modulating the relative phase between two IDTs, the positions of pressure nodes of the SLSAW in the microchannel change linearly resulting in the transportation of a single cell or microbubbles. The results also reveal that there is a good linear relationship between the relative phase and the displacement of a single cell or microbubbles. Furthermore, the single cell and the microbubbles can be transported over a predetermined distance continuously until they reach the targeted locations. This technique has its distinct advantages, such as precise position-manipulation, simple to implement, miniature size, and noninvasive character, which may provide an effective method for the position-manipulation of a single cell and microbubbles in many biological and biomedical applications.
Collapse
|
307
|
Ghaemmaghami AM, Hancock MJ, Harrington H, Kaji H, Khademhosseini A. Biomimetic tissues on a chip for drug discovery. Drug Discov Today 2011; 17:173-81. [PMID: 22094245 DOI: 10.1016/j.drudis.2011.10.029] [Citation(s) in RCA: 248] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2011] [Revised: 10/04/2011] [Accepted: 10/31/2011] [Indexed: 01/09/2023]
Abstract
Developing biologically relevant models of human tissues and organs is an important enabling step for disease modeling and drug discovery. Recent advances in tissue engineering, biomaterials and microfluidics have led to the development of microscale functional units of such models also referred to as 'organs on a chip'. In this review, we provide an overview of key enabling technologies and highlight the wealth of recent work regarding on-chip tissue models. In addition, we discuss the current challenges and future directions of organ-on-chip development.
Collapse
Affiliation(s)
- Amir M Ghaemmaghami
- Division of Immunology, School of Molecular Medical Sciences, Queen's Medical Centre, University of Nottingham, Nottingham NG7 2UH, UK
| | | | | | | | | |
Collapse
|
308
|
Vannoy CH, Tavares AJ, Noor MO, Uddayasankar U, Krull UJ. Biosensing with quantum dots: a microfluidic approach. SENSORS (BASEL, SWITZERLAND) 2011; 11:9732-63. [PMID: 22163723 PMCID: PMC3231262 DOI: 10.3390/s111009732] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2011] [Revised: 10/04/2011] [Accepted: 10/17/2011] [Indexed: 01/09/2023]
Abstract
Semiconductor quantum dots (QDs) have served as the basis for signal development in a variety of biosensing technologies and in applications using bioprobes. The use of QDs as physical platforms to develop biosensors and bioprobes has attracted considerable interest. This is largely due to the unique optical properties of QDs that make them excellent choices as donors in fluorescence resonance energy transfer (FRET) and well suited for optical multiplexing. The large majority of QD-based bioprobe and biosensing technologies that have been described operate in bulk solution environments, where selective binding events at the surface of QDs are often associated with relatively long periods to reach a steady-state signal. An alternative approach to the design of biosensor architectures may be provided by a microfluidic system (MFS). A MFS is able to integrate chemical and biological processes into a single platform and allows for manipulation of flow conditions to achieve, by sample transport and mixing, reaction rates that are not entirely diffusion controlled. Integrating assays in a MFS provides numerous additional advantages, which include the use of very small amounts of reagents and samples, possible sample processing before detection, ultra-high sensitivity, high throughput, short analysis time, and in situ monitoring. Herein, a comprehensive review is provided that addresses the key concepts and applications of QD-based microfluidic biosensors with an added emphasis on how this combination of technologies provides for innovations in bioassay designs. Examples from the literature are used to highlight the many advantages of biosensing in a MFS and illustrate the versatility that such a platform offers in the design strategy.
Collapse
Affiliation(s)
- Charles H. Vannoy
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Rd. North, Mississauga, Ontario L5L 1C6, Canada; E-Mails: (C.H.V.); (A.J.T.); (M.O.N.); (U.U.)
| | | | | | | | - Ulrich J. Krull
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Rd. North, Mississauga, Ontario L5L 1C6, Canada; E-Mails: (C.H.V.); (A.J.T.); (M.O.N.); (U.U.)
| |
Collapse
|
309
|
|
310
|
Shin H, Mahto SK, Kim JH, Rhee SW. Exposure of BALB/3T3 fibroblast cells to temporal concentration profile of toxicant inside microfluidic device. BIOCHIP JOURNAL 2011. [DOI: 10.1007/s13206-011-5304-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
311
|
Ho J, Tan MK, Go DB, Yeo LY, Friend JR, Chang HC. Paper-Based Microfluidic Surface Acoustic Wave Sample Delivery and Ionization Source for Rapid and Sensitive Ambient Mass Spectrometry. Anal Chem 2011; 83:3260-6. [DOI: 10.1021/ac200380q] [Citation(s) in RCA: 103] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Jenny Ho
- Center for Microfluidics and Medical Diagnostics, Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, 46556, Indiana, United States
- MicroNano Physics Research Laboratory, Department of Mechanical Engineering, Monash University and the Melbourne Centre for Nanofabrication, Melbourne, 3800, Victoria, Australia
| | - Ming K. Tan
- Center for Microfluidics and Medical Diagnostics, Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, 46556, Indiana, United States
- Small Scale Transport Research Laboratory, Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, 46556, Indiana, United States
| | - David B. Go
- Small Scale Transport Research Laboratory, Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, 46556, Indiana, United States
| | - Leslie Y. Yeo
- MicroNano Physics Research Laboratory, Department of Mechanical Engineering, Monash University and the Melbourne Centre for Nanofabrication, Melbourne, 3800, Victoria, Australia
| | - James R. Friend
- MicroNano Physics Research Laboratory, Department of Mechanical Engineering, Monash University and the Melbourne Centre for Nanofabrication, Melbourne, 3800, Victoria, Australia
| | - Hsueh-Chia Chang
- Center for Microfluidics and Medical Diagnostics, Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, 46556, Indiana, United States
| |
Collapse
|
312
|
Oliveira J. Magnificent seven. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2011; 7:3-4. [PMID: 21188702 DOI: 10.1002/smll.201002161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
|