301
|
Hassan N, McCarville K, Morinaga K, Mengatto CM, Langfelder P, Hokugo A, Tahara Y, Colwell CS, Nishimura I. Titanium biomaterials with complex surfaces induced aberrant peripheral circadian rhythms in bone marrow mesenchymal stromal cells. PLoS One 2017; 12:e0183359. [PMID: 28817668 PMCID: PMC5560683 DOI: 10.1371/journal.pone.0183359] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 08/02/2017] [Indexed: 01/08/2023] Open
Abstract
Circadian rhythms maintain a high level of homeostasis through internal feed-forward and -backward regulation by core molecules. In this study, we report the highly unusual peripheral circadian rhythm of bone marrow mesenchymal stromal cells (BMSCs) induced by titanium-based biomaterials with complex surface modifications (Ti biomaterial) commonly used for dental and orthopedic implants. When cultured on Ti biomaterials, human BMSCs suppressed circadian PER1 expression patterns, while NPAS2 was uniquely upregulated. The Ti biomaterials, which reduced Per1 expression and upregulated Npas2, were further examined with BMSCs harvested from Per1::luc transgenic rats. Next, we addressed the regulatory relationship between Per1 and Npas2 using BMSCs from Npas2 knockout mice. The Npas2 knockout mutation did not rescue the Ti biomaterial-induced Per1 suppression and did not affect Per2, Per3, Bmal1 and Clock expression, suggesting that the Ti biomaterial-induced Npas2 overexpression was likely an independent phenomenon. Previously, vitamin D deficiency was reported to interfere with Ti biomaterial osseointegration. The present study demonstrated that vitamin D supplementation significantly increased Per1::luc expression in BMSCs, though the presence of Ti biomaterials only moderately affected the suppressed Per1::luc expression. Available in vivo microarray data from femurs exposed to Ti biomaterials in vitamin D-deficient rats were evaluated by weighted gene co-expression network analysis. A large co-expression network containing Npas2, Bmal1, and Vdr was observed to form with the Ti biomaterials, which was disintegrated by vitamin D deficiency. Thus, the aberrant BMSC peripheral circadian rhythm may be essential for the integration of Ti biomaterials into bone.
Collapse
Affiliation(s)
- Nathaniel Hassan
- Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Oral Biology & Medicine, UCLA School of Dentistry, Los Angeles, California, United States of America
| | - Kirstin McCarville
- Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Oral Biology & Medicine, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Advanced Prosthodontics, UCLA School of Dentistry, Los Angeles, California, United States of America
| | - Kenzo Morinaga
- Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Advanced Prosthodontics, UCLA School of Dentistry, Los Angeles, California, United States of America
- Department of Oral Rehabilitation, Section of Oral Implantology, Fukuoka Dental College, Fukuoka, Japan
| | - Cristiane M. Mengatto
- Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, California, United States of America
- Department of Conservative Dentistry, School of Dentistry Federal University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Peter Langfelder
- Department of Human Genetics, David Geffen School of Medicine at UCLA, Los Angeles, California, United States of America
| | - Akishige Hokugo
- Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Plastic Surgery, David Geffen School of Medicine at UCLA, Los Angeles, California, United States of America
| | - Yu Tahara
- Department of Psychiatry & Biobehavioral Science, David Geffen School of Medicine at UCLA, Los Angeles, California, United States of America
| | - Christopher S. Colwell
- Department of Psychiatry & Biobehavioral Science, David Geffen School of Medicine at UCLA, Los Angeles, California, United States of America
| | - Ichiro Nishimura
- Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Oral Biology & Medicine, UCLA School of Dentistry, Los Angeles, California, United States of America
- Division of Advanced Prosthodontics, UCLA School of Dentistry, Los Angeles, California, United States of America
- * E-mail:
| |
Collapse
|
302
|
Sanz-Martin I, Vignoletti F, Nuñez J, Permuy M, Muñoz F, Sanz-Esporrín J, Fierravanti L, Shapira L, Sanz M. Hard and soft tissue integration of immediate and delayed implants with a modified coronal macrodesign: Histological, micro-CT and volumetric soft tissue changes from a pre-clinical in vivo study. J Clin Periodontol 2017; 44:842-853. [DOI: 10.1111/jcpe.12747] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/20/2017] [Indexed: 11/28/2022]
Affiliation(s)
- Ignacio Sanz-Martin
- Section of Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| | - Fabio Vignoletti
- Section of Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| | - Javier Nuñez
- Section of Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| | - Maria Permuy
- Faculty of Veterinary Lugo; University of Santiago de Compostela; Lugo Spain
| | - Fernando Muñoz
- Faculty of Veterinary Lugo; University of Santiago de Compostela; Lugo Spain
| | - Javier Sanz-Esporrín
- Section of Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| | - Ludovica Fierravanti
- Section of Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| | - Lior Shapira
- Department of Periodontology; Hebrew University - Hadassah Faculty of Dental Medicine; Jerusalem Israel
| | - Mariano Sanz
- Section of Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| |
Collapse
|
303
|
Smargiassi A, Bertacchini J, Checchi M, Cavani F, Ferretti M, Palumbo C. Biocompatibility Analyses of Al₂O₃-Treated Titanium Plates Tested with Osteocyte and Fibroblast Cell Lines. Biomedicines 2017; 5:E32. [PMID: 28621746 PMCID: PMC5489818 DOI: 10.3390/biomedicines5020032] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Revised: 05/31/2017] [Accepted: 06/13/2017] [Indexed: 01/01/2023] Open
Abstract
Osseointegration of a titanium implant is still an issue in dental/orthopedic implants durable over time. The good integration of these implants is mainly due to their surface and topography. We obtained an innovative titanium surface by shooting different-in-size particles of Al₂O₃ against the titanium scaffolds which seems to be ideal for bone integration. To corroborate that, we used two different cell lines: MLO-Y4 (murine osteocytes) and 293 (human fibroblasts) and tested the titanium scaffolds untreated and treated (i.e., Al₂O₃ shot-peened titanium surfaces). Distribution, density, and expression of adhesion molecules (fibronectin and vitronectin) were evaluated under scanning electron microscope (SEM) and confocal microscope (CM). DAPI and fluorochrome-conjugated antibodies were used to highlight nuclei, fibronectin, and vitronectin, under CM; cell distribution was analyzed after gold-palladium sputtering of samples by SEM. The engineered biomaterial surfaces showed under SEM irregular morphology displaying variously-shaped spicules. Both SEM and CM observations showed better outcome in terms of cell adhesion and distribution in treated titanium surfaces with respect to the untreated ones. The results obtained clearly showed that this kind of surface-treated titanium, used to manufacture devices for dental implantology: (i) is very suitable for cell colonization, essential prerequisite for the best osseointegration, and (ii) represents an excellent solution for the development of further engineered implants with the target to obtain recovery of stable dental function over time.
Collapse
Affiliation(s)
- Alberto Smargiassi
- Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze, Sezione di Morfologia Umana, Università di Modena e R.E, 41124 Modena, Italy.
| | - Jessika Bertacchini
- Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze, Sezione di Morfologia Umana, Università di Modena e R.E, 41124 Modena, Italy.
| | - Marta Checchi
- Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze, Sezione di Morfologia Umana, Università di Modena e R.E, 41124 Modena, Italy.
| | - Francesco Cavani
- Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze, Sezione di Morfologia Umana, Università di Modena e R.E, 41124 Modena, Italy.
| | - Marzia Ferretti
- Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze, Sezione di Morfologia Umana, Università di Modena e R.E, 41124 Modena, Italy.
| | - Carla Palumbo
- Dipartimento di Scienze Biomediche, Metaboliche e Neuroscienze, Sezione di Morfologia Umana, Università di Modena e R.E, 41124 Modena, Italy.
| |
Collapse
|
304
|
Millot S, Lesclous P, Colombier ML, Radoi L, Messeca C, Ballanger M, Charrier JL, Tramba P, Simon S, Berrebi A, Doguet F, Lansac E, Tribouilloy C, Habib G, Duval X, Iung B. Position paper for the evaluation and management of oral status in patients with valvular disease: Groupe de Travail Valvulopathies de la Société Française de Cardiologie, Société Française de Chirurgie Orale, Société Française de Parodontologie et d'Implantologie Orale, Société Française d'Endodontie et Société de Pathologie Infectieuse de Langue Française. Arch Cardiovasc Dis 2017. [PMID: 28629781 DOI: 10.1016/j.acvd.2017.01.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Oral health is of particular importance in patients with heart valve diseases because of the risk of infective endocarditis. Recommendations for antibiotic prophylaxis before dental procedures have been restricted, but the modalities of oral evaluation and dental care are not detailed in guidelines. Therefore, a multidisciplinary working group reviewed the literature to propose detailed approaches for the evaluation and management of buccodental status in patients with valvular disease. Simple questions asked by a non-dental specialist may draw attention to buccodental diseases. Besides clinical examination, recent imaging techniques are highly sensitive for the detection of inflammatory bone destruction directly related to oral or dental infection foci. The management of buccodental disease before cardiac valvular surgery should be adapted to the timing of the intervention. Simple therapeutic principles can be applied even before urgent intervention. Restorative dentistry and endodontic and periodontal therapy can be performed before elective valvular intervention and during the follow-up of patients at high risk of endocarditis. The detection and treatment of buccodental foci of infection should follow specific rules in patients who present with acute endocarditis. Implant placement is no longer contraindicated in patients at intermediate risk of endocarditis, and can also be performed in selected high-risk patients. The decision for implant placement should follow an analysis of general and local factors increasing the risk of implant failure. The surgical and prosthetic procedures should be performed in optimal safety conditions. It is therefore now possible to safely decrease the number of contraindicated dental procedures in patients at risk of endocarditis.
Collapse
Affiliation(s)
- Sarah Millot
- Department of oral surgery, Montpellier university hospital, 34295 Montpellier, France; Inserm 1149, 75018 Paris, France
| | - Philippe Lesclous
- Department of oral surgery, Nantes hospital, university of Nantes, Inserm U791, LIOAD, 44093 Nantes, France
| | - Marie-Laure Colombier
- Department of periodontology, Louis-Mourier hospital, AP-HP, university of Paris Descartes, 92700 Colombes, France
| | - Loredana Radoi
- Department of oral surgery, Louis-Mourier hospital, AP-HP, university of Paris Descartes, Inserm U1018, 92700 Colombes, France
| | - Clément Messeca
- Odontology department, Bichat hospital, AP-HP, 75018 Paris, France
| | - Mathieu Ballanger
- Department of oral surgery, Pitié-Salpétrière hospital, AP-HP, university of Paris Descartes, 75013 Paris, France
| | - Jean-Luc Charrier
- Department of oral surgery, Bretonneau hospital, AP-HP, university of Paris Descartes, 75018 Paris, France
| | - Philippe Tramba
- Department of implantology and prosthetics, Pitié Salpétrière hospital, AP-HP, university of Paris Descartes, 75013 Paris, France
| | - Stéphane Simon
- Endodontics department, Pitié-Salpétrière hospital, AP-HP, Paris-Diderot university, 75013 Paris, France
| | - Alain Berrebi
- Department of cardiology, Georges Pompidou european hospital, AP-HP, institut mutualiste Montsouris, 75014 Paris, France
| | - Fabien Doguet
- Department of thoracic and cardiovascular surgery, Rouen university hospital, Inserm U1096, 76000 Rouen, France
| | - Emmanuel Lansac
- Department of cardiac surgery, institut mutualiste Montsouris, 75014 Paris, France
| | - Christophe Tribouilloy
- Department of cardiology, university hospital of Amiens, Inserm U1088, Jules-Verne university of Picardie, 80480 Amiens, France
| | - Gilbert Habib
- Department of cardiology, La Timone hospital, Aix-Marseille university, 13385 Marseille, France
| | - Xavier Duval
- Centre of clinical investigations, Inserm 1425, Bichat hospital, AP-HP, Paris-Diderot university, Inserm U1137, AEPEI, 75018 Paris, France
| | - Bernard Iung
- Department of cardiology, Bichat hospital, AP-HP, DHU FIRE, Paris-Diderot university, 46, rue Henri-Huchard, 75018 Paris, France.
| |
Collapse
|
305
|
Abstract
Aim To evaluate the primary and secondary stability of implants in the posterior maxilla. Methods Patients were allocated into three groups: (A) native bone, (B) partially regenerated bone, and (C) nearly totally regenerated bone. Insertion torque (IT) and implant stability quotient (ISQ) were measured at placement, to evaluate whether satisfactory high primary stability (IT ≥ 45 N/cm; ISQ ≥ 60) was achieved; ISQ was measured 15, 30, 45, and 60 days after placement, to investigate the evolution to secondary stability. Results 133 implants (Anyridge®, Megagen) were installed in 59 patients: 55 fixtures were placed in Group A, 57 in Group B, and 21 in Group C. Fifty-two implants had satisfactory high primary stability (IT ≥ 45 N/cm; ISQ ≥ 60). A positive correlation was found between all variables (IT, ISQ at t = 0, t = 60), and statistically higher IT and ISQ values were found for implants with satisfactory high primary stability. Significant differences were found for IT and ISQ between the groups (A, B, and C); however, no drops were reported in the median ISQ values during the healing period. Conclusions The evaluation of the primary and secondary implant stability may contribute to higher implant survival/success rates in critical areas, such as the regenerated posterior maxilla. The present study is registered in the ISRCTN registry with ID ISRCTN33469250.
Collapse
|
306
|
Immediate Loading of Single Implants in the Anterior Maxilla: A 1-Year Prospective Clinical Study on 34 Patients. Int J Dent 2017; 2017:8346496. [PMID: 28611844 PMCID: PMC5458381 DOI: 10.1155/2017/8346496] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 03/13/2017] [Indexed: 01/10/2023] Open
Abstract
Purpose To present the outcomes of immediately loaded single implants placed in the anterior maxilla. Methods Over a 2-year period, all patients referred to a private clinic were considered for enrolment in this study. Inclusion criteria were single-tooth placement in postextraction sockets or healed sites of the anterior maxilla. All implants were immediately loaded and followed for a period of 1 year after the placement of definitive crowns. The outcome measures were implant stability, survival, and success. Results 34 patients were selected and 43 tapered implants with a knife-edge thread design and a nanostructured, calcium-incorporated surface (Anyridge®, Megagen, Gyeongsang, Korea) were installed. Two implants were not sufficiently stable at placement (ISQ < 60) and were considered failed for immediate loading; 41 implants had an ISQ ≥ 60 at placement and were immediately loaded. One year after the placement of definitive crowns, no implant failures were reported, for a survival rate of 100%. No biological complications were found, but 2 implants had their prosthetic abutments loosened: the implant success rate was 95.2%. Conclusions In the present study on the immediate loading of single implants in the anterior maxilla, positive outcomes were reported, with high survival (100%) and success (95.2%) rates (the present study has been registered in the ISRCTN registry, a publicly available trial register recognized by WHO and ICMJE, with number ISRCTN12935478).
Collapse
|
307
|
Ye L. [Current dental implant design and its clinical importance]. HUA XI KOU QIANG YI XUE ZA ZHI = HUAXI KOUQIANG YIXUE ZAZHI = WEST CHINA JOURNAL OF STOMATOLOGY 2017; 35:18-28. [PMID: 28326723 DOI: 10.7518/hxkq.2017.01.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The development of clinical implant dentistry was intensively affected by dental implant design improvement and innovation, which brought about new concept, even milestone-like changes of clinical protocol. The current improvements of dental implant design and their clinical importance could be highlighted as followings: 1) The implant apical design influences the implant preliminary stability in immediate implant. The apical 3-5 mm design of implant makes implant stable in immediate implant, because this part would be screwed into alveolar bone through fresh socket, the other part of implant could not be tightly screwed in the socket because of smaller implant diameter. Implant apical form, screw design, self-taping of apical part would be essential for immediate implant. 2) The enough preliminary stability of implant makes immediate prosthesis possible. When osseointegration does not occur, the implant stability comes from a mechanical anchorage, which depends on implant form, screw thread and self-taping design. 3) Implant neck design may have influence for soft tissue recession in esthetic zone. The implant with large shoulder would not be selected for the esthetic area. The platform design may be more favorable in the area. 4) The connection design between implant and abutment is thought a very important structure in implant long-term stability. Moose taper and "tube in tube" were well documented structure design in 20-year clinical practice in Peking University. 5) In last 15 years, the plenty studies showed the platform design of implant had positive influence in implant marginal bone level. Whatever in single implant restoration or multi-implant prosthesis. 6) The digital technology makes clinical work more precise and high-tech. This would be a trend in implant dentistry. New generation of chair-side digital computer-aided design/computer-aided manufacturing makes immediate prosthesis without conventional impression possible. 7) New abutment design have changed clinical protocol greatly. The All-on-four concept and Weldone concept benefit both from the abutment innovation, which were large angulated abutment and special welding abutment materials.
Collapse
Affiliation(s)
- Lin Ye
- Dept. of Oral Implant, School and Hospital of Stomatology, Peking University, Beijing 100081, China
| |
Collapse
|
308
|
Civantos A, Martínez-Campos E, Ramos V, Elvira C, Gallardo A, Abarrategi A. Titanium Coatings and Surface Modifications: Toward Clinically Useful Bioactive Implants. ACS Biomater Sci Eng 2017; 3:1245-1261. [DOI: 10.1021/acsbiomaterials.6b00604] [Citation(s) in RCA: 182] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Ana Civantos
- Tissue
Engineering Group, Institute of Biofunctional Studies, Associated
Unit to the Institute of Polymer Science and Technology (CSIC), Pharmacy
Faculty, Complutense University of Madrid (UCM), Paseo Juan XXIII 1, 28040 Madrid, Spain
- Polymer
Functionalization Group, Institute of Polymer Science and Technology, ICTP-CSIC, Juan de la Cierva, 3, 28006 Madrid, Spain
| | - Enrique Martínez-Campos
- Tissue
Engineering Group, Institute of Biofunctional Studies, Associated
Unit to the Institute of Polymer Science and Technology (CSIC), Pharmacy
Faculty, Complutense University of Madrid (UCM), Paseo Juan XXIII 1, 28040 Madrid, Spain
- Polymer
Functionalization Group, Institute of Polymer Science and Technology, ICTP-CSIC, Juan de la Cierva, 3, 28006 Madrid, Spain
| | - Viviana Ramos
- Tissue
Engineering Group, Institute of Biofunctional Studies, Associated
Unit to the Institute of Polymer Science and Technology (CSIC), Pharmacy
Faculty, Complutense University of Madrid (UCM), Paseo Juan XXIII 1, 28040 Madrid, Spain
- Noricum S.L., San Sebastián
de los Reyes, Av. Fuente Nueva, 14, 28703 Madrid, Spain
| | - Carlos Elvira
- Polymer
Functionalization Group, Institute of Polymer Science and Technology, ICTP-CSIC, Juan de la Cierva, 3, 28006 Madrid, Spain
| | - Alberto Gallardo
- Polymer
Functionalization Group, Institute of Polymer Science and Technology, ICTP-CSIC, Juan de la Cierva, 3, 28006 Madrid, Spain
| | - Ander Abarrategi
- Haematopoietic
Stem Cell Laboratory, The Francis Crick Institute, 1 Midland
Road, NW1 1AT London, U.K
| |
Collapse
|
309
|
Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study. BIOMED RESEARCH INTERNATIONAL 2017; 2017:4170537. [PMID: 28246595 PMCID: PMC5303578 DOI: 10.1155/2017/4170537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 01/04/2017] [Indexed: 11/18/2022]
Abstract
Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program. The final outcomes were implant survival, peri-implant bone loss, biologic/prosthetic complications, and “complication-free” survival of restorations. Results. Twenty-four patients were selected. Overall, 215 implants were inserted (130 maxilla, 85 mandible), 144 in extraction sockets and 71 in healed ridges. Thirty-six FFAs were delivered (21 maxilla, 15 mandible): 27 were immediately loaded and 9 were conventionally loaded. The follow-up ranged from 1 to 3 years. Two fixtures failed, yielding an implant survival rate of 95.9% (patient-based). A few complications were registered, for a “complication-free” survival of restorations of 88.9%. Conclusions. FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface are successful in the short term, with high survival and low complication rates; long-term studies are needed to confirm these outcomes.
Collapse
|
310
|
Early Bone Formation around Immediately Loaded Transitional Implants Inserted in the Human Posterior Maxilla: The Effects of Fixture Design and Surface. BIOMED RESEARCH INTERNATIONAL 2017; 2017:4152506. [PMID: 28280731 PMCID: PMC5322419 DOI: 10.1155/2017/4152506] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2016] [Accepted: 01/18/2017] [Indexed: 11/17/2022]
Abstract
Aim. To evaluate the effects of fixture design and surface on the early bone formation around immediately loaded implants inserted in the human posterior maxilla. Materials and Methods. Ten totally edentulous subjects received two transitional implants: one tapered implant with knife-edge threads/nanostructured calcium-incorporated surface (test: Anyridge®, Megagen, Gyeongbuk, South Korea) and one cylindrical implant with self-tapping threads/sandblasted surface (control: EZPlus®, Megagen). The implants were placed according to a split-mouth design and immediately loaded to support an interim complete denture; after 8 weeks, they were removed for histologic/histomorphometric analysis. The bone-to-implant contact (BIC%) and the bone density (BD%) were calculated. The Wilcoxon test was used to evaluate the differences. Results. With test implants, a mean BIC% and BD% of 35.9 (±9.1) and 31.8 (±7.5) were found. With control implants, a mean BIC% and BD% of 29.9 (±7.6) and 32.5 (±3.9) were found. The mean BIC% was higher with test implants, but this difference was not significant (p = 0.16). Similar BD% were found in the two groups (p = 0.9). Conclusions. In the posterior maxilla, under immediate loading conditions, implants with a knife-edge thread design/nanostructured calcium-incorporated surface seem to increase the peri-implant endosseous healing properties, when compared to implants with self-tapping thread design/sandblasted surface.
Collapse
|
311
|
One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study. BIOMED RESEARCH INTERNATIONAL 2016; 2016:6792972. [PMID: 28058261 PMCID: PMC5183747 DOI: 10.1155/2016/6792972] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 10/17/2016] [Accepted: 11/08/2016] [Indexed: 11/17/2022]
Abstract
Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, placed in the jaws and femurs of domestic sheep. Ten New Zealand mixed breed sheep were used. A One-piece prototype Ti (control) and one Zr (test) implant were placed in the mandible, and one of each implant (Ti and Zr) was placed into the femoral epicondyle of each animal. The femur implants were submerged and unloaded; the mandibular implants were placed using a one-stage transgingival protocol and were nonsubmerged. After a healing period of 12 weeks, %BIC was measured. The overall survival rate for mandibular and femur implants combined was 87.5%. %BIC was higher for Zr implants versus Ti implants in the femur (85.5%, versus 78.9%) (p = 0.002). Zirconia implants in the mandible showed comparable %BIC to titanium implants (72.2%, versus 60.3%) (p = 0.087). High failure rate of both Zr and Ti one-piece implants in the jaw could be attributed to the one-piece design and surface characteristics of the implant that could have influenced osseointegration. Further clinical trials are recommended to evaluate the performance of zirconia implants under loading conditions.
Collapse
|