1
|
Alberto Cortés J, Enrique Gómez J, Ignacio Silva P, Arévalo L, Arévalo Rodríguez I, Isabel Alvarez M, Beltrán S, Fernanda Corrales I, Angel Muller E, Ruiz G, Iván Gómez P. Guía de atención integral para la prevención, detección temprana y tratamiento de las complicaciones del embarazo, parto y puerperio: sección toxoplasmosis en el embarazo. INFECTIO 2012. [DOI: 10.1016/s0123-9392(12)70018-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
2
|
Prospective study of congenital toxoplasmosis screening with use of IgG avidity and multiplex nested PCR methods. J Clin Microbiol 2011; 49:2552-6. [PMID: 21543572 DOI: 10.1128/jcm.02092-10] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Acute infection with Toxoplasma gondii during pregnancy can cause congenital toxoplasmosis. The aim of this study was to evaluate whether screening with the use of IgG avidity and multiplex nested PCR methods was effective to detect a high-risk pregnancy. In a prospective study, serum T. gondii IgG avidity was measured in consecutive 146 pregnant women testing positive for T. gondii antibody and either positive or equivocal for IgM. Multiplex nested PCR for T. gondii DNA on amniotic fluid, maternal blood, and umbilical cord blood were performed with informed consent. A total of 51 (34.9%) women presented with low IgG avidity (<30%), 15 (10.3%) presented with borderline avidity (30 to 35%), and 80 (54.8%) presented with high avidity (>35%) indices. Amniotic fluid obtained at amniocentesis or birth yielded positive PCR results in nine women with low IgG avidity indices. Of these nine women, three had congenital toxoplasmosis. None of women with high or border line IgG avidity indices had a positive PCR result in the amniotic fluid or congenital toxoplasmosis. No congenital toxoplasmosis was detected in women whose amniotic fluids yielded negative PCR results. Ingestion of raw or undercooked meat was found to be the main risk factor for acute T. gondii infection. Congenital toxoplasmosis screening with a combination of IgG avidity in the maternal blood and multiplex nested PCR in the amniotic fluid was useful for detecting a high risk pregnancy and diagnosing congenital toxoplasmosis.
Collapse
|
3
|
Nishikawa A, Yamada H, Yamamoto T, Mizue Y, Akashi Y, Hayashi T, Nihei T, Nishiwaki M, Nishihira J. A case of congenital toxoplasmosis whose mother demonstrated serum low IgG avidity and positive tests for multiplex-nested PCR in the amniotic fluid. J Obstet Gynaecol Res 2009; 35:372-8. [DOI: 10.1111/j.1447-0756.2008.00953.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
4
|
Thalib L, Gras L, Romand S, Prusa A, Bessieres MH, Petersen E, Gilbert RE. Prediction of congenital toxoplasmosis by polymerase chain reaction analysis of amniotic fluid. BJOG 2005; 112:567-74. [PMID: 15842278 DOI: 10.1111/j.1471-0528.2005.00486.x] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To determine the accuracy of polymerase chain reaction (PCR) analysis of amniotic fluid for fetal toxoplasmosis according to clinical predictors of outcome and study centre. DESIGN Prospective cohort study. SETTING Nine European centres. POPULATION Women with suspected toxoplasma infection identified by prenatal screening. METHODS Logistic regression was used to examine the effects of gestational age at maternal seroconversion, treatment and timing of amniocentesis, on PCR accuracy, and to calculate the post-test probability of congenital toxoplasmosis. MAIN OUTCOME MEASURES Infants had congenital toxoplasmosis if specific IgG persisted beyond 11.5 months. Uninfected infants had undetectable IgG in the absence of anti-toxoplasma treatment. RESULTS Of 593 PCR results, 64 were positive (57 confirmed infected), and 529 were negative (23 confirmed infected). The likelihood ratio for a positive PCR result decreased significantly with trimester at seroconversion, but did not change significantly for a negative result. Weak associations were detected between sensitivity and, inversely, with specificity, and gestational age at maternal seroconversion. There was no significant association between sensitivity and centre, type or duration of treatment, or timing of amniocentesis. Specificity differed significantly between centres (P < 0.001). The change in pre- to post-test probability of infection was maximal for a positive PCR after first trimester seroconversion, affecting 1% of women tested, and a negative PCR after third trimester seroconversion, affecting half the women tested. CONCLUSIONS Prediction of the risk of congenital toxoplasmosis should combine estimates of test accuracy and maternal-fetal transmission, which take account of the gestational age at which the mother seroconverted. Local laboratory standards will affect the generalisability of these results.
Collapse
Affiliation(s)
- L Thalib
- Department of Community Medicine and Behavioural Sciences, Faculty of Medicine, Kuwait University, Kuwait
| | | | | | | | | | | | | |
Collapse
|
5
|
Antsaklis A, Daskalakis G, Papantoniou N, Mentis A, Michalas S. Prenatal diagnosis of congenital toxoplasmosis. Prenat Diagn 2002; 22:1107-11. [PMID: 12454967 DOI: 10.1002/pd.476] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Ninety-three pregnant women with Toxoplasma gondii seroconversion during pregnancy underwent prenatal diagnosis of fetal toxoplasmosis. The following tests were used: (1). amniocentesis for mouse inoculation (93 subjects), (2). amplification of T. gondii DNA by polymerase chain reaction (PCR) (79 subjects), and (3). cordocentesis for the detection of T. gondii-specific IgM antibodies (13 subjects). All patients had serial ultrasonographic scans to detect those fetuses with abnormalities that could be associated with congenital toxoplasmosis. Eighteen pregnancies (19.4%) had evidence of vertical transmission. A total of 11/18 (61.1%) had positive amniotic mouse inoculation test, while 10/12 (83.3%) had positive PCR results. The combination of both tests allowed the prenatal diagnosis in 17/18 infected fetuses (94.4%). All patients who underwent cordocentesis for the detection of T. gondii-specific IgM antibodies had negative results. However, in two of the above cases fetal toxoplasmosis was detected by amniotic fluid studies. In five of the infected fetuses there were abnormal ultrasonographic findings. All pregnancies with evidence of vertical transmission were terminated, whereas the remaining pregnancies proceeded normally to term. The present data showed that amniotic fluid studies, preferably PCR amplification of T. gondii DNA, are the best diagnostic tools for the detection of vertical transmission in pregnancies with seroconversion during pregnancy.
Collapse
Affiliation(s)
- Aris Antsaklis
- First Department of Obstetrics and Gynaecology, Fetal Medicine Unit, Alexandra Hospital, University of Athens, Athens, Greece
| | | | | | | | | |
Collapse
|
6
|
Abstract
Toxoplasmosis is an anthropozoonotic disease endemic world-wide, caused by the apicomplexan Toxoplasma gondii. Although the course of infection is generally benign, it can cause significant morbidity and mortality in the developing fetus and in immunocompromised individuals. Biological diagnosis classically relies upon serology and direct detection of the parasite by inoculation to laboratory animals. In the past decade, the use of the polymerase chain reaction (PCR) has made a significant improvement in both the prenatal diagnosis of congenital toxoplasmosis and the detection of acute disease in the immunocompromised patient. Nevertheless, like many 'in-house' PCR assays, the PCR-Toxoplasma suffers from lack of standardization and variable performance according to the laboratory. A wide variety of primers has been used in different assays, but few comparative tests have been performed. Moreover, in contrast to other parasitic diseases, PCR-Toxoplasma has not yet attained a sufficient level of sensitivity, regardless of the clinical condition considered. These drawbacks are discussed, together with the undoubted gain that PCR has brought to this difficult diagnosis.
Collapse
Affiliation(s)
- Patrick Bastien
- CNRS UMR 5093 Gènome des Protozoaires Parasites, Laboratoire de Parasitologie-Mycologie, Centre Hospitalier Universitaire, Faculté de Médecine, 163 Rue A. Broussonet, 34090 Montpellier, France.
| |
Collapse
|
7
|
Nield LE, Silverman ED, Taylor GP, Smallhorn JF, Mullen JBM, Silverman NH, Finley JP, Law YM, Human DG, Seaward PG, Hamilton RM, Hornberger LK. Maternal anti-Ro and anti-La antibody-associated endocardial fibroelastosis. Circulation 2002; 105:843-8. [PMID: 11854125 DOI: 10.1161/hc0702.104182] [Citation(s) in RCA: 174] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Maternal anti-Ro and anti-La antibodies are associated with congenital heart block (CHB). Although endocardial fibroelastosis (EFE) has been described in isolated cases of autoantibody-mediated CHB, the natural history and pathogenesis of this disease are poorly understood. METHODS AND RESULTS We retrospectively reviewed the clinical history, echocardiography, and pathology of fetuses and children with EFE associated with CHB born to mothers positive for anti-Ro or anti-La antibodies at 5 centers. Thirteen patients were identified, 6 with a prenatal and 7 with a postnatal diagnosis. Six mothers were positive for anti-Ro and anti-La antibodies, and 7 were positive for anti-Ro antibodies only. Only 1 mother had autoimmune disease. Severe ventricular dysfunction was seen in all fetal and postnatal cases. Four fetal and 3 postnatal cases had EFE at initial presentation. However, 2 fetal and 4 postnatal cases developed EFE 6 to 12 weeks and 7 months to 5 years from CHB diagnosis, respectively, even despite ventricular pacing in 6 postnatal cases. Eleven (85%) either died (n=9) or underwent cardiac transplantation (n=2) secondary to the EFE. Pathologic assessment of the explanted heart, available in 10 cases, revealed moderate to severe EFE in 7 and mild EFE in 3 cases, predominantly involving the left ventricle. Immunohistochemistry in 4 cases (including 3 fetuses) demonstrated deposition of IgG in 4 and IgM in 3 and T-cell infiltrates in 3 cases, suggesting an immune response by the affected fetus or child. CONCLUSIONS EFE occurs in the presence of autoantibody-mediated CHB despite adequate ventricular pacing. Autoantibody-associated EFE has a very high mortality rate, whether developing in fetal or postnatal life.
Collapse
Affiliation(s)
- Lynne E Nield
- Department of Paediatrics, Division of Cardiology, The Hospital for Sick Children, University of Toronto Faculty of Medicine, Toronto, Ontario, Canada
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Ambroise-Thomas P, Schweitzer M, Thiebaugeorges O, Schweitzer JM. La prévention de la toxoplasmose congénitale en France. Évaluation des risques. Résultats et perspectives du dépistage anténatal et du suivi du nouveau-né. BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE 2001. [DOI: 10.1016/s0001-4079(19)34515-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
9
|
Costa JM, Ernault P, Gautier E, Bretagne S. Prenatal diagnosis of congenital toxoplasmosis by duplex real-time PCR using fluorescence resonance energy transfer hybridization probes. Prenat Diagn 2001; 21:85-8. [PMID: 11241531 DOI: 10.1002/1097-0223(200102)21:2<85::aid-pd18>3.0.co;2-1] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The diagnosis of congenital toxoplasmosis frequently relies on PCR tests of amniotic fluid (AF). A duplex real-time quantitative PCR test based on fluorescence resonance energy transfer was developed to quantify the parasite load and to decrease the risk of contamination. An internal control based on the detection of 10 pg mouse DNA added to the AF was included to check for PCR efficiency. The relationship between the parasite load and the occurrence of ultrasonographic abnormalities in 87 samples of AF was analyzed. Seven AF (8%) had a parasitic load > 10(3); 14 (16%) had > 10(2)-< or =10(3); 26 (30%) had > 10-< or = 10(2); and 40 (46%) had < or = 10 parasites/ml. Four of the six AF with cerebral ventriculomegaly had >10(3) parasites/ml. The other two had 130 and 24 parasites/ml, respectively. No parasitic loads of > 10(3) parasites/ml and no ultrasonographic abnormalities were observed in the 11 AF with maternal toxoplasmosis in the third trimester. Therefore, there is a trend to associate high parasite count with ultrasonographic abnormality, but the main concern remains early maternal infection. The importance of quantification should be better evaluated with postnatal studies. The duplex LightCycler PCR test currently provides rapid and safe results.
Collapse
Affiliation(s)
- J M Costa
- Laboratoire de Biologie Moléculaire, Hôpital Américain, BP 109, 92202 Neuilly, France.
| | | | | | | |
Collapse
|
10
|
Zufferey J, Hohlfeld P, Bille J, Fawer CL, Blanc D, Pinon JM, Vaudaux B. Value of the comparative enzyme-linked immunofiltration assay for early neonatal diagnosis of congenital Toxoplasma infection. Pediatr Infect Dis J 1999; 18:971-5. [PMID: 10571432 DOI: 10.1097/00006454-199911000-00007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The transplacental transfer of specific maternal IgG antibodies makes the diagnosis of congenital Toxoplasma infection quite difficult in the neonate. The enzyme-linked immunofiltration assay (ELIFA), comparing at delivery the immunologic profile of the mother's antibody response and that of her child, allows discrimination between IgG antibodies of maternal origin and IgGs synthesized by the fetus. OBJECTIVE To evaluate the diagnostic reliability of the comparative ELIFA for diagnosing congenital Toxoplasma infection as well as the reliability of testing for IgM- and IgA-specific antibodies in cord blood. METHODS From November, 1991, to December, 1995, an ELIFA was prospectively performed at delivery on blood samples obtained from 227 women with primary Toxoplasma infection during pregnancy and from their infants. For each child the ELIFA result was evaluated in relation to the serologic follow-up: disappearance of specific anti-Toxoplasma gondii IgG antibodies in the absence of treatment before 12 months of age indicating an uninfected child, as opposed to persistence beyond 12 months of age indicative of a congenital infection. RESULTS Of 227 children 139 were lost to follow-up. Among the 88 children available for follow up, the ELIFA was negative in 70 infants, 69 of whom were confirmed to be uninfected. Thirteen of these 69 cord blood ELIFA-negative samples were positive for anti-T. gondii IgM and/or IgA detected by means of a conventional immunosorbent agglutination assay. Of the remaining 18 children (representing 75% of all new cases of congenital toxoplasmosis diagnosed during the study period at our institution), the ELIFA was positive in 16, negative in 1 and inconclusive in 1. CONCLUSIONS The ELIFA test is a valuable tool for diagnosing congenital T. gondii infection and in differentiating between true neonatal infection and cord blood contamination. In our experience the diagnostic sensitivity of the ELIFA test was 94.1% and the specificity was 98.6%. The cord blood was contaminated by specific maternal anti-T. gondii IgA and/or IgM in as many as 20% of the cases.
Collapse
Affiliation(s)
- J Zufferey
- Department of Microbiology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
11
|
Foulon W, Pinon JM, Stray-Pedersen B, Pollak A, Lappalainen M, Decoster A, Villena I, Jenum PA, Hayde M, Naessens A. Prenatal diagnosis of congenital toxoplasmosis: a multicenter evaluation of different diagnostic parameters. Am J Obstet Gynecol 1999; 181:843-7. [PMID: 10521739 DOI: 10.1016/s0002-9378(99)70311-x] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE Our purpose was to evaluate different methods of diagnosing congenital toxoplasmosis prenatally by amniocentesis and cordocentesis. STUDY DESIGN In a retrospective multicenter study, we investigated consecutive women who had seroconversion for Toxoplasma gondii during pregnancy and who underwent either amniocentesis or cordocentesis or both to obtain a prenatal diagnosis of fetal toxoplasmosis. Data were obtained from 122 patients recruited in 6 different European Toxoplasma reference centers. Infants born to these mothers were followed up until 1 year of age to confirm or exclude congenital toxoplasmosis. Sensitivity, specificity, positive predictive value, and negative predictive value were measured for the following parameters: (1) detection of the parasite in amniotic fluid by mouse inoculation, (2) detection of the parasite in amniotic fluid by in vitro cell culture, (3) detection of Toxoplasma deoxyribonucleic acid in amniotic fluid by a polymerase chain reaction assay, (4) detection of the parasite in fetal blood by mouse inoculation, (5) detection of specific immunoglobulin M antibodies in fetal blood, and (6) detection of specific immunoglobulin A antibodies in fetal blood. RESULTS The polymerase chain reaction test performed on amniotic fluid had the highest level of sensitivity (81%) and also a high level of specificity (96%). The combination of the polymerase chain reaction test and mouse inoculation of amniotic fluid increased sensitivity to 91%. The sensitivity of immunoglobulins M and A in fetal blood was 47% and 38%, respectively. In congenitally infected fetuses a negative correlation was observed between positive serologic parameters and gestational age at the time of maternal infection and at prenatal diagnosis. CONCLUSION Congenital toxoplasmosis is best predicted by prenatal examination with the combination of T gondii polymerase chain reaction and mouse inoculation of amniotic fluid. The role of cordocentesis in the diagnosis of congenital toxoplasmosis is limited.
Collapse
Affiliation(s)
- W Foulon
- Department of Obstetrics, Academisch Ziekenhuis, Free University of Brussels, Belgium
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Faure AK, Fricker-Hidalgo H, Pelloux H, Bost-Bru C, Goullier-Fleuret A, Ambroise-Thomas P. Lack of value of specific IgA detection in the postnatal diagnosis of congenital toxoplasmosis. J Clin Lab Anal 1999; 13:27-30. [PMID: 10025734 PMCID: PMC6808018 DOI: 10.1002/(sici)1098-2825(1999)13:1<27::aid-jcla5>3.0.co;2-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
To improve the performance of the postnatal diagnosis of congenital toxoplasmosis, we assessed the detection of IgA antibodies to Toxoplasma gondii by ELISA, compared with that of IgM by ELISA, ISAGA, and IFAT and neosynthesized antibodies using Western blot. From 1993 to 1996, IgA antibodies were detected using the Toxo IgA test (SFRI, Société Française de Recherches et d'Investissements, Bordeaux, France), in 195 serum and cord blood samples from 63 infants born to mothers who seroconverted during pregnancy. Eighteen infants had proven congenital toxoplasmosis (confirmed by the presence of IgG after 12 months of life) and 45 had no congenital toxoplasmosis (negativity of IgG after 6-12 months of life). The sensitivity of IgA detection by ELISA on serum and cord blood samples was 38.9 and 54.5% respectively, which is low when compared with the sensitivity of IgM detection by ISAGA (66.7% on serum samples, 90.9% on cord blood), ELISA (61.1% on sera, 81.8% on cord blood) and Western blot (83.3% on sera, 72.7% on cord blood). IgA antibodies were never detected by ELISA earlier than IgM or neosynthesized Ig (antibodies synthesized by infants). Thus, the detection of IgA antibodies by Toxo IgA is not useful in improving the diagnosis of congenital toxoplasmosis.
Collapse
Affiliation(s)
- A K Faure
- Département de Parasitologie, Mycologie Médicale et Moléculaire, Centre Hospitalier Universitaire, Grenoble, France
| | | | | | | | | | | |
Collapse
|
13
|
Faure AK, Fricker-Hidalgo H, Pelloux H, Bost-Bru C, Goullier-Fleuret A, Ambroise-Thomas P. Lack of value of specific IgA detection in the postnatal diagnosis of congenital toxoplasmosis. J Clin Lab Anal 1999. [DOI: 10.1002/(sici)1098-2825(1999)13:1%3c27::aid-jcla5%3e3.0.co;2-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
14
|
Fricker-Hidalgo H, Pelloux H, Racinet C, Grefenstette I, Bost-Bru C, Goullier-Fleuret A, Ambroise-Thomas P. Detection of Toxoplasma gondii in 94 placentae from infected women by polymerase chain reaction, in vivo, and in vitro cultures. Placenta 1998; 19:545-9. [PMID: 9778129 DOI: 10.1016/s0143-4004(98)91049-9] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The biological diagnosis of congenital toxoplasmosis at birth is important to determine the infant's treatment. The aim of this study was to evaluate the placenta results in the congenital toxoplasmosis diagnosis and to compare them with those obtained with other samples collected at birth (cord blood and newborn blood). A total of 94 placentas, of which 33 came from fetuses suspected of or with proven congenital toxoplasmosis (CT+) and 61 from definitely or probably non-infected fetuses (CT-), was analysed by in vitro culture, mouse inoculation and polymerase chain reaction (PCR). The PCR sensitivity was higher (60.9 per cent) than that of cell culture (29.6 per cent) and mouse inoculation (51.5 per cent) but the number of PCR positive results in CT - patients was also higher (9.5 per cent). The presence of Toxoplasma gondii in the placenta tissues was the only argument at birth (IgM and neosynthesized Ig were negative) in three out of the 33 CT+ cases. The detection of IgM by ELISA and ISAGA and the detection of neosynthesized Ig by immunoblotting were more satisfactory to diagnose congenital toxoplasmosis but the placenta analysis was important to improve the sensitivity of the diagnosis at birth, especially when the prenatal diagnosis was negative or not performed.
Collapse
Affiliation(s)
- H Fricker-Hidalgo
- Département de Parasitologie-Mycologie, Centre Hospitalier Universitaire, Grenoble, France
| | | | | | | | | | | | | |
Collapse
|