1
|
Cordelli E, Ardoino L, Benassi B, Consales C, Eleuteri P, Marino C, Sciortino M, Villani P, Brinkworth MH, Chen G, McNamee JP, Wood AW, Belackova L, Verbeek J, Pacchierotti F. Effects of Radiofrequency Electromagnetic Field (RF-EMF) exposure on pregnancy and birth outcomes: A systematic review of experimental studies on non-human mammals. ENVIRONMENT INTERNATIONAL 2023; 180:108178. [PMID: 37729852 DOI: 10.1016/j.envint.2023.108178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 08/24/2023] [Accepted: 08/29/2023] [Indexed: 09/22/2023]
Abstract
BACKGROUND The World Health Organization is coordinating an international project aimed at systematically reviewing the evidence regarding the association between radiofrequency electromagnetic field (RF-EMF) exposure and adverse health effects. Within the project, 6 topics have been prioritized by an expert group, which include reproductive health outcomes. OBJECTIVES According to the protocol published in 2021, a systematic review and meta-analyses on the adverse effects of RF-EMF exposure during pregnancy in offspring of experimental animals were conducted. METHODS Three electronic databases (PubMed, Scopus and EMF Portal) were last searched on September 8 or 17, 2022. Based on predefined selection criteria, the obtained references were screened by two independent reviewers. Studies were included if they met the following criteria: 1) original, sham controlled experimental study on non-human mammals exposed in utero, published in peer-reviewed journals, 2) the experimental RF-EMF exposure was within the frequency range 100 kHz-300 GHz, 3) the effects of RF-EMF exposure on fecundity (litter size, embryonic/fetal losses), on the offspring health at birth (decrease of weight or length, congenital malformations, changes of sex ratio) or on delayed effects (neurocognitive alterations, female infertility or early-onset cancer) were studied. Study characteristics and outcome data were extracted by two reviewers. Risk of bias (RoB) was assessed using the Office of Health Assessment and Translation (OHAT) guidelines. Study results were pooled in a random effects meta-analysis comparing average exposure to no-exposure and in a dose-response meta-analysis using all exposure doses, after exclusion of studies that were rated at "high concern" for RoB. Subgroup analyses were conducted for species, Specific Absorption Rate (SAR) and temperature increase. The certainty of the evidence was assessed using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach. RESULTS Eighty-eight papers could be included in this review. Effects on fecundity. The meta-analysis of studies on litter size, conducted at a whole-body average SAR of 4.92 W/kg, did not show an effect of RF-EMF exposure (MD 0.05; 95% CI -0.21 to 0.30). The meta-analysis of studies on resorbed and dead fetuses, conducted at a whole-body average SAR of 20.26 W/kg, showed a significant increase of the incidence in RF-EMF exposed animals (OR 1.84; 95% CI 1.27 to 2.66). The results were similar in the dose-response analysis. Effects on the offspring health at birth. The meta-analysis of studies on fetal weight, conducted at a whole-body average SAR of 9.83 W/kg, showed a small decrease in RF-EMF exposed animals (SMD 0.31; 95% CI 0.15 to 0.48). The meta-analysis of studies on fetal length, conducted at a whole-body average SAR of 4.55 W/kg, showed a moderate decrease in length at birth (SMD 0.45; 95% CI 0.07 to 0.83). The meta-analysis of studies on the percentage of fetuses with malformations, conducted at a whole-body average SAR of 6.75 W/kg, showed a moderate increase in RF-EMF exposed animals (SMD -0.45; 95% CI -0.68 to -0.23). The meta-analysis of studies on the incidence of litters with malformed fetuses, conducted at a whole-body average SAR of 16.63 W/kg, showed a statistically significant detrimental RF-EMF effect (OR 3.22; 95% CI 1.9 to 5.46). The results were similar in the dose-response analyses. Delayed effects on the offspring health. RF-EMF exposure was not associated with detrimental effects on brain weight (SMD 0.10; 95% CI -0.09 to 0.29) and on learning and memory functions (SMD -0.54; 95% CI -1.24 to 0.17). RF-EMF exposure was associated with a large detrimental effect on motor activity functions (SMD 0.79; 95% CI 0.21 to 1.38) and a moderate detrimental effect on motor and sensory functions (SMD -0.66; 95% CI -1.18 to -0.14). RF-EMF exposure was not associated with a decrease of the size of litters conceived by F2 female offspring (SMD 0.08; 95% CI -0.39 to 0.55). Notably, meta-analyses of neurobehavioural effects were based on few studies, which suffered of lack of independent replication deriving from only few laboratories. DISCUSSION There was high certainty in the evidence for a lack of association of RF-EMF exposure with litter size. We attributed a moderate certainty to the evidence of a small detrimental effect on fetal weight. We also attributed a moderate certainty to the evidence of a lack of delayed effects on the offspring brain weight. For most of the other endpoints assessed by the meta-analyses, detrimental RF-EMF effects were shown, however the evidence was attributed a low or very low certainty. The body of evidence had limitations that did not allow an assessment of whether RF-EMF may affect pregnancy outcomes at exposure levels below those eliciting a well-known adverse heating impact. In conclusion, in utero RF-EMF exposure does not have a detrimental effect on fecundity and likely affects offspring health at birth, based on the meta-analysis of studies in experimental mammals on litter size and fetal weight, respectively. Regarding possible delayed effects of in utero exposure, RF-EMF probably does not affect offspring brain weight and may not decrease female offspring fertility; on the other hand, RF-EMF may have a detrimental impact on neurobehavioural functions, varying in magnitude for different endpoints, but these last findings are very uncertain. Further research is needed on the effects at birth and delayed effects with sample sizes adequate for detecting a small effect. Future studies should use standardized endpoints for testing prenatal developmental toxicity and developmental neurotoxicity (OECD TG 414 and 426), improve the description of the exposure system design and exposure conditions, conduct appropriate dosimetry characterization, blind endpoint analysis and include several exposure levels to better enable the assessment of a dose-response relationship. PROTOCOL REGISTRATION AND PUBLICATION The protocol was published in Pacchierotti et al., 2021 and registered in PROSPERO CRD42021227746 (https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=227746).
Collapse
Affiliation(s)
- Eugenia Cordelli
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy.
| | - Lucia Ardoino
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - Barbara Benassi
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - Claudia Consales
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - Patrizia Eleuteri
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - Carmela Marino
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | | | - Paola Villani
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - Martin H Brinkworth
- School of Chemistry and Bioscience, Faculty of Life Sciences, University of Bradford, Bradford, UK
| | - Guangdi Chen
- Bioelectromagnetics Laboratory, Zhejiang University School of Medicine, Hangzhou, China
| | - James P McNamee
- Non-Ionizing Radiation Health Sciences Division, Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Canada
| | - Andrew W Wood
- Department of Health Sciences and Biostatistics, Swinburne University of Technology, Hawthorn, Australia
| | - Lea Belackova
- University Medical Centers Amsterdam, Coronel Institute of Occupational Health, Cochrane Work, Amsterdam, The Netherlands
| | - Jos Verbeek
- University Medical Centers Amsterdam, Coronel Institute of Occupational Health, Cochrane Work, Amsterdam, The Netherlands
| | - Francesca Pacchierotti
- Division Health Protection Technologies, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy.
| |
Collapse
|
2
|
Lai H, Levitt BB. The roles of intensity, exposure duration, and modulation on the biological effects of radiofrequency radiation and exposure guidelines. Electromagn Biol Med 2022; 41:230-255. [PMID: 35438055 DOI: 10.1080/15368378.2022.2065683] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
In this paper, we review the literature on three important exposure metrics that are inadequately represented in most major radiofrequency radiation (RFR) exposure guidelines today: intensity, exposure duration, and signal modulation. Exposure intensity produces unpredictable effects as demonstrated by nonlinear effects. This is most likely caused by the biological system's ability to adjust and compensate but could lead to eventual biomic breakdown after prolonged exposure. A review of 112 low-intensity studies reveals that biological effects of RFR could occur at a median specific absorption rate of 0.0165 W/kg. Intensity and exposure duration interact since the dose of energy absorbed is the product of intensity and time. The result is that RFR behaves like a biological "stressor" capable of affecting numerous living systems. In addition to intensity and duration, man-made RFR is generally modulated to allow information to be encrypted. The effects of modulation on biological functions are not well understood. Four types of modulation outcomes are discussed. In addition, it is invalid to make direct comparisons between thermal energy and radiofrequency electromagnetic energy. Research data indicate that electromagnetic energy is more biologically potent in causing effects than thermal changes. The two likely functionthrough different mechanisms. As such, any current RFR exposure guidelines based on acute continuous-wave exposure are inadequate for health protection.
Collapse
Affiliation(s)
- Henry Lai
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | | |
Collapse
|
3
|
Verma S, Keshri GK, Karmakar S, Mani KV, Chauhan S, Yadav A, Sharma M, Gupta A. Effects of Microwave 10 GHz Radiation Exposure in the Skin of Rats: An Insight on Molecular Responses. Radiat Res 2021; 196:404-416. [PMID: 34407201 DOI: 10.1667/rade-20-00155.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 08/06/2021] [Indexed: 11/03/2022]
Abstract
Microwave (MW) radiation poses the risk of potential hazards on human health. The present study investigated the effects of MW 10 GHz exposure for 3 h/day for 30 days at power densities of 5.23 ± 0.25 and 10.01 ± 0.15 mW/cm2 in the skin of rats. The animals exposed to 10 mW/cm2 (corresponded to twice the ICNIRP-2020 occupational reference level of MW exposure for humans) exhibited significant biophysical, biochemical, molecular and histological alterations compared to sham-irradiated animals. Infrared thermography revealed an increase in average skin surface temperature by 1.8°C and standard deviation of 0.3°C after 30 days of 10 mW/cm2 MW exposure compared to the sham-irradiated animals. MW exposure also led to oxidative stress (ROS, 4-HNE, LPO, AOPP), inflammatory responses (NFkB, iNOS/NOS2, COX-2) and metabolic alterations [hexokinase (HK), lactate dehydrogenase (LDH), citrate synthase (CS) and glucose-6-phospahte dehydrogenase (G6PD)] in 10 mW/cm2 irradiated rat skin. A significant alteration in expression of markers associated with cell survival (Akt/PKB) and HSP27/p38MAPK-related stress-response signaling cascade was observed in 10 mW/cm2 irradiated rat skin compared to sham-irradiated rat skin. However, MW-irradiated groups did not show apoptosis, evident by unchanged caspase-3 levels. Histopathological analysis revealed a mild cytoarchitectural alteration in epidermal layer and slight aggregation of leukocytes in 10 mW/cm2 irradiated rat skin. Altogether, the present findings demonstrated that 10 GHz exposure in continuous-wave mode at 10 mW/cm2 (3 h/day, 30 days) led to significant alterations in molecular markers associated with adaptive stress-response in rat skin. Furthermore, systematic scientific studies on more prevalent pulsed-mode of MW-radiation exposure for prolonged duration are warranted.
Collapse
Affiliation(s)
- Saurabh Verma
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Gaurav K Keshri
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Santanu Karmakar
- Microwave Tube Research and Development Centre (MTRDC), DRDO, Bangalore, India
| | - Kumar Vyonkesh Mani
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Satish Chauhan
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Anju Yadav
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Manish Sharma
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| | - Asheesh Gupta
- Defence Institute of Physiology and Allied Sciences (DIPAS), DRDO, Delhi, India
| |
Collapse
|
4
|
Bhartiya P, Mumtaz S, Lim JS, Kaushik N, Lamichhane P, Nguyen LN, Jang JH, Yoon SH, Choi JJ, Kaushik NK, Choi EH. Pulsed 3.5 GHz high power microwaves irradiation on physiological solution and their biological evaluation on human cell lines. Sci Rep 2021; 11:8475. [PMID: 33875781 PMCID: PMC8055702 DOI: 10.1038/s41598-021-88078-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Accepted: 04/07/2021] [Indexed: 02/02/2023] Open
Abstract
Microwave (MW) radiation is increasingly being used for several biological applications. Many investigations have focused on understanding the potential influences of pulsed MW irradiation on biological solutions. The current study aimed to investigate the effects of 3.5 GHz pulsed MW radiation-irradiated liquid solutions on the survival of human cancer and normal cells. Different physiological solutions such as phosphate buffer saline, deionized water, and Dulbecco's modified Eagle medium (DMEM) for cell culture growth were irradiated with pulsed MW radiation (45 shots with the energy of 1 mJ/shot). We then evaluated physiological effects such as cell viability, metabolic activity, mitochondrial membrane potential, cell cycle, and cell death in cells treated with MW-irradiated biological solutions. As MW irradiation with power density ~ 12 kW/cm2 mainly induces reactive nitrogen oxygen species in deionized water, it altered the cell cycle, membrane potential, and cell death rates in U373MG cells due to its high electric field ~ 11 kV/cm in water. Interestingly, MW-irradiated cell culture medium and phosphate-buffered saline did not alter the cellular viability and metabolic energy of cancer and normal cells without affecting the expression of genes responsible for cell death. Taken together, MW-irradiated water can alter cellular physiology noticeably, whereas irradiated media and buffered saline solutions induce negligible or irrelevant changes that do not affect cellular health.
Collapse
Affiliation(s)
- Pradeep Bhartiya
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Sohail Mumtaz
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Jun Sup Lim
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Neha Kaushik
- College of Engineering, Department of Biotechnology, University of Suwon, Hwaseong, 18323, Korea
| | - Pradeep Lamichhane
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Linh Nhat Nguyen
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Jung Hyun Jang
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Sang Ho Yoon
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Jin Joo Choi
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea
| | - Nagendra Kumar Kaushik
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea.
| | - Eun Ha Choi
- Plasma Bioscience Research Center/Applied Plasma Medicine Center, Department of Plasma Bio Display, Department of Electrical and Biological Physics, Kwangwoon University, Seoul, 01897, Korea.
| |
Collapse
|
5
|
Qi XY, Qiu XS, Jiang JY, Chen YX, Tang LM, Shi HF. Microwaves increase the effectiveness of systemic antibiotic treatment in acute bone infection: experimental study in a rat model. J Orthop Surg Res 2019; 14:286. [PMID: 31488167 PMCID: PMC6729059 DOI: 10.1186/s13018-019-1342-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Accepted: 08/21/2019] [Indexed: 12/28/2022] Open
Abstract
Background Osteomyelitis is a challenge for orthopedic surgeons due to its protracted treatment process. Microwaves (MWs) can increase blood perfusion due to their thermal effect. Furthermore, MWs demonstrated significant bactericidal effects in vitro. In the present study, we assumed that the application of a 2450-MHz-frequency MW together with systemic antibiotic treatment would provide synergy for the treatment of acute osteomyelitis. Methods The medullary cavity of the right tibia was inoculated with 107 CFU of methicillin-sensitive Staphylococcus aureus (MSSA-ATCC 29213) in 40 rats, and the rats were randomly divided into four groups according to treatment: group I, saline (control); group II, saline + MW therapy; group III, systemic cefuroxime; and group IV, systemic cefuroxime + MW therapy. MWs were applied for 20 min per day to the infected limbs, and all rats were sacrificed on the 7th day. The severity of tibial osteomyelitis was assessed by quantitative culture analysis. Results Bacterial counts in groups III and IV were significantly reduced compared with those in the control (p = 0.001 and < 0.001, respectively). Furthermore, significant differences were detected between groups III and IV (p = 0.033). However, the difference between groups I and II was nonsignificant (p = 0.287). Conclusion Our experimental model suggests that MW therapy provides a significant synergy for systemic antibiotic treatment. However, further clinical trials are required to safely use this treatment modality in patients.
Collapse
Affiliation(s)
- Xiao-Yang Qi
- Department of Orthopaedics, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, 321 Zhongshan Road, Nanjing, China.,Department of Surgery, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, 68 Gehu Road, Changzhou, China
| | - Xu-Sheng Qiu
- Department of Orthopaedics, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, 321 Zhongshan Road, Nanjing, China. .,Department of Orthopaedics, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, 321 Zhongshan Road, Nanjing, China.
| | - Jiang-Yun Jiang
- Department of Orthopaedics, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, 321 Zhongshan Road, Nanjing, China
| | - Yi-Xin Chen
- Department of Orthopaedics, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, 321 Zhongshan Road, Nanjing, China. .,Department of Orthopaedics, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, 321 Zhongshan Road, Nanjing, China.
| | - Li-Ming Tang
- Department of Surgery, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, 68 Gehu Road, Changzhou, China
| | - Hong-Fei Shi
- Department of Orthopaedics, Nanjing Drum Tower Hospital, Clinical College of Nanjing Medical University, 321 Zhongshan Road, Nanjing, China.,Department of Orthopaedics, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, 321 Zhongshan Road, Nanjing, China
| |
Collapse
|
6
|
Tan S, Wang H, Xu X, Zhao L, Zhang J, Dong J, Yao B, Wang H, Zhou H, Gao Y, Peng R. Study on dose-dependent, frequency-dependent, and accumulative effects of 1.5 GHz and 2.856 GHz microwave on cognitive functions in Wistar rats. Sci Rep 2017; 7:10781. [PMID: 28883530 PMCID: PMC5589914 DOI: 10.1038/s41598-017-11420-9] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Accepted: 08/24/2017] [Indexed: 12/18/2022] Open
Abstract
Many studies have revealed the cognitive decline induced by microwave radiation. However, the systematic study on dose-dependent, frequency-dependent and accumulative effects of microwave exposure at different frequencies was lacking. Here, we studied the relationship between the effects and the power and frequency of microwave and analyzed the accumulative effects of two different frequency microwaves with the same average power density. After microwave radiation, declines in spatial learning and memory and fluctuations of brain electric activities were found in the 10 mW/cm2 single frequency exposure groups and accumulative exposure groups. Meanwhile, morphological evidences in hippocampus also supported the cognitive dysfunction. Moreover, the decrease of Nissl contents in neurons indicated protein-based metabolic disorders in neurons. By detecting the key functional proteins of cholinergic transmitter metabolism, cytokines, energy metabolism and oxidative stress in the hippocampus, we found that microwave could lead to multiple metabolic disorders. Our results showed that microwave-induced cognitive decline was largely determined by its power rather than frequency. Injury effects were also found in accumulative exposure groups. We particularly concerned about the safety dose, injury effects and accumulative effects of microwaves, which might be very valuable in the future.
Collapse
Affiliation(s)
- Shengzhi Tan
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Hui Wang
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China.
| | - Xinping Xu
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Li Zhao
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Jing Zhang
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Ji Dong
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Binwei Yao
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Haoyu Wang
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Hongmei Zhou
- Division of Radiation Protection and Health Physics, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Yabing Gao
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China
| | - Ruiyun Peng
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, P. R. China.
| |
Collapse
|
7
|
Wang C, Wang X, Zhou H, Dong G, Guan X, Wang L, Xu X, Wang S, Chen P, Peng R, Hu X. Effects of pulsed 2.856 GHz microwave exposure on BM-MSCs isolated from C57BL/6 mice. PLoS One 2015; 10:e0117550. [PMID: 25658708 PMCID: PMC4319787 DOI: 10.1371/journal.pone.0117550] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2014] [Accepted: 12/29/2014] [Indexed: 12/23/2022] Open
Abstract
The increasing use of microwave devices over recent years has meant the bioeffects of microwave exposure have been widely investigated and reported. However the exact biological fate of bone marrow MSCs (BM-MSCs) after microwave radiation remains unknown. In this study, the potential cytotoxicity on MSC proliferation, apoptosis, cell cycle, and in vitro differentiation were assayed following 2.856 GHz microwave exposure at a specific absorption rate (SAR) of 4 W/kg. Importantly, our findings indicated no significant changes in cell viability, cell division and apoptosis after microwave treatment. Furthermore, we detected no significant effects on the differentiation ability of these cells in vitro, with the exception of reduction in mRNA expression levels of osteopontin (OPN) and osteocalcin (OCN). These findings suggest that microwave treatment at a SAR of 4 W/kg has undefined adverse effects on BM-MSCs. However, the reduced-expression of proteins related to osteogenic differentiation suggests that microwave can the influence at the mRNA expression genetic level.
Collapse
Affiliation(s)
- Changzhen Wang
- Beijing Institute of Radiation Medicine, Beijing, China
- * E-mail: (CW); (XH)
| | - Xiaoyan Wang
- Beijing Institute of Basic Medical Sciences, Beijing, China
| | - Hongmei Zhou
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Guofu Dong
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Xue Guan
- NO. 281 Hospital of People’s Liberation Army, Qinhuangdao, China
| | - Lifeng Wang
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Xinping Xu
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Shuiming Wang
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Peng Chen
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Ruiyun Peng
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Xiangjun Hu
- Beijing Institute of Radiation Medicine, Beijing, China
- * E-mail: (CW); (XH)
| |
Collapse
|
8
|
Sagioglou NE, Manta AK, Giannarakis IK, Skouroliakou AS, Margaritis LH. Apoptotic cell death duringDrosophilaoogenesis is differentially increased by electromagnetic radiation depending on modulation, intensity and duration of exposure. Electromagn Biol Med 2014; 35:40-53. [DOI: 10.3109/15368378.2014.971959] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
9
|
Homenko A, Kapilevich B, Kornstein R, Firer MA. Effects of 100 GHz radiation on alkaline phosphatase activity and antigen-antibody interaction. Bioelectromagnetics 2009; 30:167-75. [PMID: 19051324 DOI: 10.1002/bem.20466] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Equipment that generates microwave radiation (MWR) spanning the frequency range of 300 MHz-100 GHz is becoming more common. While MWR lacks sufficient energy to break chemical bonds, the disagreement as to whether MWR exposure is detrimental to cellular dysfunction may be difficult to clarify using complex systems such as whole animals, cells, or cell extracts. Recently, the high frequency range of terahertz (THz) radiation has been explored and sources of radiation and its detectors have been developed. THz radiation is associated with the frequency interval from 100 GHz to 20 THz and constitutes the next frontier in imaging science and technology. In the present study, we investigated the effect of radiation in the low frequency THz range (100 GHz) on two defined molecular interactions. First, the interaction of soluble or immobilized calf alkaline phosphatase with the substrate p-nitrophenylphosphate and second, the interaction between an antibody (mouse monoclonal anti-DNP) and its antigen (DNP). Irradiation of enzyme either prior to addition of substrate or during the enzymatic reaction resulted in small but significant reductions in enzyme activity. These differences were not observed if the enzyme had previously been immobilized onto plastic microwells. Exposure of immobilized antigen to radiation did not influence the ability of the antigen to interact with antibody. However, irradiation appeared to decrease the stability of previously formed antigen-antibody complexes. Our data suggest that 100 GHz radiation can induce small but statistically significant alterations in the characteristics of these two types of biomolecular interactions.
Collapse
Affiliation(s)
- A Homenko
- Faculty of Medicine, Department of Physiology and Pharmacology, Tel-Aviv University, Tel-Aviv, Israel
| | | | | | | |
Collapse
|
10
|
Cotgreave IA. Biological stress responses to radio frequency electromagnetic radiation: are mobile phones really so (heat) shocking? Arch Biochem Biophys 2005; 435:227-40. [PMID: 15680925 DOI: 10.1016/j.abb.2004.12.004] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2004] [Revised: 12/03/2004] [Indexed: 11/19/2022]
Abstract
Cells phenotypically adapt to alterations in their intra- and extracellular environment via organised alterations to gene and protein expression. Many chemical and physical stimuli are known to drive such responses, including the induction of oxidative stress and heat shock. Increasing use of mobile telephones in our society, has brought focus on the potential for radio frequency (microwave) electromagnetic radiation to elicit biological stress responses, in association with potentially detrimental effects of this to human health. Here we review evidence suggesting altered gene and protein expression in response to such emissions, with particular focus on heat shock proteins. Non-thermal induction of heat shock proteins has been claimed by a number of investigations in in vitro cellular systems, and appears pleiotropic for many other regulatory events. However, many of these studies are flawed by inconsistencies in exposure models, cell types used and the independent reproducibility of the findings. Further, the paucity of evidence from in vivo experimentation is largely contradictory. Therefore, the validity of these effects in human health risk assessment remain unsubstantiated. Where possible, suggestions for further experimental clarification have been provided.
Collapse
Affiliation(s)
- Ian A Cotgreave
- Division of Biochemical Toxicology, Institute of Environmental Medicine, Karolinska Institute, Box 210, S-17177 Stockholm, Sweden.
| |
Collapse
|