1
|
Dykstra AB, Flick TG, Lee B, Blue LE, Angell N. Chip-Based Capillary Zone Electrophoresis Mass Spectrometry for Rapid Resolution and Quantitation of Critical Quality Attributes in Protein Biotherapeutics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1952-1963. [PMID: 33730487 DOI: 10.1021/jasms.0c00424] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The aspiration of the multi-attribute method (MAM) is to utilize a single mass spectrometry-based method that can measure multiple attributes simultaneously, thus enabling data-driven decisions more quickly and efficiently. However, challenges associated with identifying and quantitating critical quality attributes such as asparagine deamidation and isoaspartic acid using conventional ultrahigh-pressure liquid chromatography (UHPLC) coupled to mass spectrometry have necessitated long gradients to ensure sufficient separation for quantitation. Microfluidic chip-based capillary zone electrophoresis mass spectrometry (CZE-MS) shows potential to enable rapid charge-based separation of peptide mixtures, and this approach was evaluated using multipeptide mixtures of synthetic peptides as well as digested protein therapeutics. In these experiments, repeatability, linearity, and peak-to-peak resolution of several peptide families containing asparagine deamidation and/or isoaspartic acid were demonstrated. In addition, a comparison of peptide map results acquired with both UHPLC-MS and CZE-MS for two enzymatically digested biological therapeutics showed comparable sequence coverage and quantitation results between the two approaches. As MAM becomes increasingly utilized for analysis of biological therapeutics, MS instrument demand will rapidly increase, resulting in a bottleneck. A CZE-based separation shows potential to alleviate this bottleneck by drastically increasing MAM throughput while providing results comparable to those acquired using conventional UHPLC separations.
Collapse
Affiliation(s)
- Andrew B Dykstra
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Tawnya G Flick
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Burton Lee
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Laura E Blue
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Nic Angell
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| |
Collapse
|
2
|
Langan TJ, Holland LA. Capillary electrophoresis coupled to electrospray mass spectrometry through a coaxial sheath flow interface and semi-permanent phospholipid coating for the determination of oligosaccharides labeled with 1-aminopyrene-3,6,8-trisulfonic acid. Electrophoresis 2012; 33:607-13. [DOI: 10.1002/elps.201100449] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
3
|
Pantůčková P, Gebauer P, Boček P, Křivánková L. Electrolyte systems for on-line CE-MS: Detection requirements and separation possibilities. Electrophoresis 2009; 30:203-14. [DOI: 10.1002/elps.200800262] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
4
|
Herrero M, Ibañez E, Cifuentes A. Capillary electrophoresis-electrospray-mass spectrometry in peptide analysis and peptidomics. Electrophoresis 2008; 29:2148-60. [DOI: 10.1002/elps.200700404] [Citation(s) in RCA: 107] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
5
|
18 Coupling CE and microchip-based devices with mass spectrometry. ACTA ACUST UNITED AC 2008. [DOI: 10.1016/s0149-6395(07)00018-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
6
|
Schappler J, Guillarme D, Prat J, Veuthey JL, Rudaz S. Coupling CE with atmospheric pressure photoionization MS for pharmaceutical basic compounds: Optimization of operating parameters. Electrophoresis 2007; 28:3078-87. [PMID: 17724698 DOI: 10.1002/elps.200700012] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The use of CE coupled with MS (CE-MS) has evolved as a useful tool to analyze charged species in small sample volumes. Because of its sensitivity, versatility and ease of implementation, the ESI interface is currently the method of choice to hyphenate CE to MS. An alternative can be the atmospheric pressure photoionization (APPI) source, however, numerous parameters must be optimized for its coupling to CE. After evaluation of the sheath liquid composition and the CE capillary outlet position, an experimental design methodology was assessed for optimizing other ionization source parameters, such as sheath liquid flow rate, drying gas flow rate and temperature, nebulizing gas pressure, vaporizer temperature, and capillary voltage. For this purpose, a fractional factorial design (FFD) was selected as a screening procedure to identify factors which significantly influence sensitivity and efficiency. A face-centered central composite design (CCD) was then used to predict and optimize sensitivity, taking into account the most relevant variables. Sensitivity was finally evaluated with the optimized conditions and height-to-noise ratios (H/N) around 10 were achieved for an injection of 200 ng/mL of each analyte.
Collapse
Affiliation(s)
- Julie Schappler
- Laboratory of Analytical Pharmaceutical Chemistry, School of Pharmaceutical Sciences, EPGL, University of Geneva, University of Lausanne, Geneva, Switzerland
| | | | | | | | | |
Collapse
|
7
|
Snovida SI, Chen VC, Krokhin O, Perreault H. Isolation and Identification of Sialylated Glycopeptides from Bovine α1-Acid Glycoprotein by Off-Line Capillary Electrophoresis MALDI-TOF Mass Spectrometry. Anal Chem 2006; 78:6556-63. [PMID: 16970334 DOI: 10.1021/ac060738k] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Sialylated glycopeptides contained in liquid chromatographic fractions of bovine alpha1-glycoprotein tryptic digests were isolated from asialo peptides using capillary electrophoresis (CE). CE effluents were deposited directly onto a metallic target and analyzed using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. This method allowed the characterization of four N-glycosylation sites in the glycoprotein, and each site was observed as a set of sialylated peptide glycoforms. Tandem mass spectrometry was used to confirm peptide sequences and glycan content in glycoforms. The CE method developed for this study resulted in a very clear separation of the sialylated from the asialo content of glycoprotein digests and proved very useful in the determination of the nature and location of sialylated glycans along the protein chain. This article is the first report describing the use of on-target CE fraction collection using a MALDI removable sample concentrator.
Collapse
Affiliation(s)
- Sergei I Snovida
- Department of Chemistry, University of Manitoba, Winnipeg, Manitoba, Canada R3T 2N2
| | | | | | | |
Collapse
|
8
|
Stutz H. Advances in the analysis of proteins and peptides by capillary electrophoresis with matrix-assisted laser desorption/ionization and electrospray-mass spectrometry detection. Electrophoresis 2005; 26:1254-90. [PMID: 15776483 DOI: 10.1002/elps.200410130] [Citation(s) in RCA: 135] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE-MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE-MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on-line preconcentration techniques (transient capillary isotachophoresis, solid-phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision-induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2-D on-line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE-ESI-MS in proteomics, in the clinical and diagnostic field, and in the food sector.
Collapse
Affiliation(s)
- Hanno Stutz
- University of Salzburg, Department of Molecular Biology, Division of Chemistry, Salzburg, Austria.
| |
Collapse
|
9
|
Prange A, Pröfrock D. Application of CE–ICP–MS and CE–ESI–MS in metalloproteomics: challenges, developments, and limitations. Anal Bioanal Chem 2005; 383:372-89. [PMID: 16158292 DOI: 10.1007/s00216-005-3420-0] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2005] [Revised: 06/30/2005] [Accepted: 06/30/2005] [Indexed: 11/25/2022]
Abstract
Application of capillary electrophoresis (CE) as a high-resolution separation technique in metalloproteomics research is critically reviewed. The focus is on the requirements and challenges involved in coupling CE to sensitive element and molecule-specific detection techniques such as inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionisation mass spectrometry (ESI-MS). The complementary application of both detection techniques to the structural and functional characterisation of metal-binding proteins and their structural metal-binding moieties is emphasised. Beneficial aspects and limitations of mass spectrometry hyphenated to CE are discussed, on the basis of the literature published in this field over the last decade. Recent metalloproteomics applications of CE are reviewed to demonstrate its potential and limitations in modern biochemical speciation analysis and to indicate future directions of this technique.
Collapse
Affiliation(s)
- Andreas Prange
- Department of Marine Bioanalytical Chemistry, GKSS Research Centre, Institute for Coastal Research, Max-Planck Str. 1, 21502 Geesthacht, Germany.
| | | |
Collapse
|
10
|
Mass spectrometry detection in capillary electrophoresis. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/s0166-526x(05)45009-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
11
|
Monton MRN, Terabe S. Recent Developments in Capillary Electrophoresis-Mass Spectrometry of Proteins and Peptides. ANAL SCI 2005; 21:5-13. [PMID: 15675508 DOI: 10.2116/analsci.21.5] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Many researchers have invested considerable efforts toward improving capillary electrophoresis (CE)-mass spectrometry (MS) systems so they can be applied better to standard analyses. This review highlights the developments in CE-MS of proteins and peptides over the last five years. It includes the developments in interfaces, sample-enrichment techniques, microfabricated devices, and some applications, largely in capillary zone electrophoresis (CZE), capillary isoelectric focusing (CIEF) and capillary isotachophoresis formats.
Collapse
Affiliation(s)
- Maria Rowena N Monton
- Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297, Japan.
| | | |
Collapse
|
12
|
Monton MRN, Terabe S. Field-enhanced sample injection for high-sensitivity analysis of peptides and proteins in capillary electrophoresis–mass spectrometry. J Chromatogr A 2004; 1032:203-11. [PMID: 15065797 DOI: 10.1016/j.chroma.2003.10.038] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Field-enhanced sample injection (FESI) was used to improve the concentration sensitivity of a capillary electrophoresis (CE)-mass spectrometry (MS) system with sheath flow configuration. Using some bioactive peptides, more than 3000-fold improvement in signal was obtained, permitting analysis in the low nM (fmol/microl) levels. The system was further evaluated for analysis of complex peptide mixtures by using low concentration tryptic digests of standard proteins. Rapid identification of the original protein was obtained by database searching using the observed molecular masses of the peptides, and by comparison of actual MS-MS spectra of selected peptides with the predicted fragmentation patterns.
Collapse
Affiliation(s)
- Maria Rowena N Monton
- Graduate School of Science, Himeji Institute of Technology, Kamigori, Hyogo 678-1297, Japan.
| | | |
Collapse
|
13
|
Janini GM, Zhou M, Yu LR, Blonder J, Gignac M, Conrads TP, Issaq HJ, Veenstra TD. On-Column Sample Enrichment for Capillary Electrophoresis Sheathless Electrospray Ionization Mass Spectrometry: Evaluation for Peptide Analysis and Protein Identification. Anal Chem 2003; 75:5984-93. [PMID: 14588041 DOI: 10.1021/ac0301548] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-separated analyte zones. Capillaries with different inside and outside diameters were evaluated to optimize the performance of the CE-MS system, resulting in a mass limit of detection of 500 amol for tandem MS analysis of a standard peptide using a 20-microm-i.d. capillary. The improved design incorporates an efficient method to preconcentrate a sample directly within the CE capillary followed by its electrophoretic separation and detection using a true zero dead-volume sheathless CE-MS interface. Testing of this novel CE-MS system showed its ability to characterize proteomic samples such as protein digests, in-gel-digested proteins, and hydrophobic peptides as well as to quantitate ICAT-labeled peptides.
Collapse
Affiliation(s)
- George M Janini
- Laboratory of Proteomics and Analytical Technologies and Image Analysis Laboratory, SAIC-Frederick, Inc., National Cancer Institute at Frederick, P.O. Box B, Frederick, Maryland 21702, USA.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Jarman JL, Todebush RA, de Haseth JA. Glass nebulizer interface for capillary electrophoresis-Fourier transform infrared spectrometry. J Chromatogr A 2002; 976:19-26. [PMID: 12462592 DOI: 10.1016/s0021-9673(02)01160-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A capillary electrophoresis system has been successfully interfaced to a Fourier transform infrared spectrometer. The design of the interface is a custom-designed glass microconcentric nebulizer. Typical deposit characteristics include reproducible circular deposits of uniform thickness that lack any splatter as found in earlier designs. Interface performance is demonstrated in that there is no loss of electrical current during operation and spectra of analytes can be readily produced. Furthermore, it has been shown that the interface maintains the plug flow characteristic of capillary electrophoresis.
Collapse
|
15
|
Neusüss C, Pelzing M, Macht M. A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometry. Electrophoresis 2002; 23:3149-59. [PMID: 12298087 DOI: 10.1002/1522-2683(200209)23:18<3149::aid-elps3149>3.0.co;2-8] [Citation(s) in RCA: 84] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) approach has been developed for routine application in proteomic studies. Robustness of the coupling is achieved by using a standard coaxial sheath-flow sprayer. Thereby, greater stability than nanoelectrospray ionization-mass spectrometry coupling of sheathless capillary electrophoresis or nanoliquid chromatography (nano-LC) is achieved, resulting in stable operation for several weeks and unattended overnight sequences. The applied sheath flow is reduced to 1-2 microL/min in order to increase sensitivity. Standard peptides and those of digests of standard proteins and gel-separated proteins can be detected in the low femtomole range (full scan and MS/MS). Detection limits are found to be as low as 500 amol. Low femtomole amounts are required for unequivocal identification by MS/MS experiments in the ion trap and subsequent database search. By applying a simple pH-mediated stacking the concentration sensitivity can be lowered to some tens of fmol/microL (nM), depending on capillary size. This sensitivity is close to published values for sheathless CE-MS and nano-LC-MS, respectively (a comparison to reference values is presented). Moreover, with capillaries of about 50 cm in length separations in less than 10 min are possible resulting in a throughput of up to four analyses per hour. This is a factor of 4-12 times faster than nano-LC separation, being the state-of-the-art techniques for proteomic studies.
Collapse
|
16
|
Affiliation(s)
- Shen Hu
- Department of Chemistry, University of Washington, Seattle 98195-1700, USA
| | | |
Collapse
|
17
|
Hille JM, Freed AL, Wätzig H. Possibilities to improve automation, speed and precision of proteome analysis: a comparison of two-dimensional electrophoresis and alternatives. Electrophoresis 2001; 22:4035-52. [PMID: 11824628 DOI: 10.1002/1522-2683(200111)22:19<4035::aid-elps4035>3.0.co;2-9] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Proteome analysis requires fast methods with high separation efficiencies in order to screen the various cell and tissue types for their proteome expression and monitor the effect of environmental conditions and time on this expression. The established two-dimensional gel electrophoresis (2-DE) is by far too slow for a consequential screening. Moreover, it is not precise enough to observe changes in protein concentrations. There are various approaches that promise faster, automated proteome analysis. This article concentrates on capillary (CT isoelectric focusing coupled to mass spectrometry (CIEF-MSn) and preparative IEF followed by size-exclusion chromatography, hyphenated with MS (PIEF-SEC-MS). These two approaches provide a similar separation pattern as the established 2-DE technique and therefore allow for the continued use of data based on this traditional approach. Their performances have been discussed and compared to 2-DE, evaluating 169 recent articles. Data on analysis time, automation, the detection limit, quantitation, peak capacity, mass and pI accuracy, as well as on the required sample amount are compared in a table.
Collapse
Affiliation(s)
- J M Hille
- Institute of Pharmaceutical Chemistry, University of Braunschweig, Germany
| | | | | |
Collapse
|
18
|
Abstract
The article gives a comprehensive review on the recent developments in the applications of high-performance capillary electromigration methods, including zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography, to analysis, preparation and physicochemical characterization of peptides. The article presents new approaches to the theoretical description and experimental verification of electromigration behavior of peptides, and covers the methodological aspects of capillary electroseparations of peptides, such as strategy and rules for the rational selection of separation mode and experimental conditions, sample treatment, suppression of peptide adsorption to the inner capillary wall, new developments in individual separation modes and new designs of detection systems. Several types of applications of capillary electromigration methods to peptide analysis are presented: conventional qualitative and quantitative analysis for determination of purity, determination in biomatrices, monitoring of physical and chemical changes and enzymatic conversions, amino acid and sequence analysis and peptide mapping of proteins. Some examples of micropreparative peptide separations are given and capabilities of capillary electromigration techniques to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- V Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague.
| |
Collapse
|
19
|
Patrick JS, Lagu AL. Review applications of capillary electrophoresis to the analysis of biotechnology-derived therapeutic proteins. Electrophoresis 2001; 22:4179-96. [PMID: 11824636 DOI: 10.1002/1522-2683(200111)22:19<4179::aid-elps4179>3.0.co;2-8] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The number of proteins produced by recombinant DNA technology continues to grow at a rapid pace. In this review, the emphasis is on proteins that are of therapeutic interest. Aspects of protein analysis, such as glycoform separation of proteins produced in mammalian cells and the separation of oligosaccharides for structure elucidation, are covered. The use of antibodies as therapeutic proteins is growing and currently antibodies are the largest class of proteins produced by biotechnology. This has merited a separate section on analysis of antibodies by capillary electrophoresis (CE). Applications of mass spectrometry as an ancillary technique, used in conjunction with CE, are also covered briefly. This review covers the literature since 1999.
Collapse
Affiliation(s)
- J S Patrick
- Lilly Research Laboratories, A Division of Eli Lilly and Co., Indianapolis, IN 46285, USA
| | | |
Collapse
|
20
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2000; 35:1148-1155. [PMID: 11006610 DOI: 10.1002/1096-9888(200009)35:9<1148::aid-jms982>3.0.co;2-r] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of mass spectrometry. Each bibliography is divided into 11 sections: 1 Books, Reviews & Symposia; 2 Instrumental Techniques & Methods; 3 Gas Phase Ion Chemistry; 4 Biology/Biochemistry: Amino Acids, Peptides & Proteins; Carbohydrates; Lipids; Nucleic Acids; 5 Pharmacology/Toxicology; 6 Natural Products; 7 Analysis of Organic Compounds; 8 Analysis of Inorganics/Organometallics; 9 Surface Analysis; 10 Environmental Analysis; 11 Elemental Analysis. Within each section, articles are listed in alphabetical order with respect to author (3 Weeks journals - Search completed at 28th. June 2000)
Collapse
|