1
|
Lopes D, Morés L, da Silva M, Schneider M, Merib J, Carasek E. Determination of hormones in urine by hollow fiber microporous membrane liquid-liquid extraction associated with 96-well plate system and HPLC-FLD detection. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1207:123406. [PMID: 35944416 DOI: 10.1016/j.jchromb.2022.123406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/11/2022] [Accepted: 08/01/2022] [Indexed: 10/16/2022]
Abstract
In this work, hollow-fiber microporous membrane liquid-liquid extraction (HF-MMLLE) was associated with a 96-well plate system for the determination of estrone, 17-β-estradiol, estriol and 17-α-ethinylestradiol in urine samples. This method exhibited some advantages, such as low cost, easy application, high-throughput and environmentally-friendly aspects. The type of organic solvent to fill the membrane, ionic strength effect, sample dilution, extraction and desorption time, and desorption solvent were examined. After the optimizations, the conditions were comprised of 45 min of extraction, 1-octanol as organic solvent and 15% (w/v) of NaCl; methanol was used as desorption solvent, and the desorption time was fixed at 10 min. The dilution of the sample increased the sensitivity due to the reduction of matrix effects; thus, urine samples were diluted 40-fold. The limits of detection ranged from 0.03 μg L-1 for 17-β-estradiol to 15 μg L-1 for estrone, and the limits of quantification ranged from 0.1 μg L-1 for 17-β-estradiol to 10 μg L-1 for estrone. The intra-day precision varied from 1.0% for estriol to 13.3% for 17-α-ethinylestradiol, and inter-day precision varied from 7.3% for estrone to 18.1% for estriol. The relative recoveries varied from 82 to 118%.
Collapse
Affiliation(s)
- Daniela Lopes
- Departamento de Química, Universidade Federal de Santa Catarina, SC 88040-900, Brazil
| | - Lucas Morés
- Departamento de Química, Universidade Federal de Santa Catarina, SC 88040-900, Brazil
| | - Mayara da Silva
- Departamento de Química, Universidade Federal de Santa Catarina, SC 88040-900, Brazil
| | - Mauana Schneider
- Departamento de Química, Universidade Federal de Santa Catarina, SC 88040-900, Brazil
| | - Josias Merib
- Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, RS 90050-170, Brazil
| | - Eduardo Carasek
- Departamento de Química, Universidade Federal de Santa Catarina, SC 88040-900, Brazil.
| |
Collapse
|
2
|
Pierri ME, Morés L, Bernardi G, Carasek E. Multiclass determination of endocrine disruptors in urine by hollow fiber microporous membrane and liquid chromatography. Anal Biochem 2022; 652:114725. [PMID: 35597269 DOI: 10.1016/j.ab.2022.114725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 05/04/2022] [Accepted: 05/06/2022] [Indexed: 11/16/2022]
Abstract
A simple and rapid methodology was developed using hollow fiber membrane microporous and a 96-well plate system for a high throughput multiclass determination of endocrine disruptors in human urine (diclofenac, diazepam, carbamazepine, ibuprofen, naproxen, carbofuran, methyl parathion, 17-α-ethynyl estradiol, bisphenol A and benzophenone). The quantification and detection of the chemicals were carried out by an HPLC-diode array detector. The fixed conditions for carrying out the method optimization were 1.5 mL of sample and 300 μL of solvent desorption. Multivariate and univariate models were applied to optimize the parameters of the method, achieving the following conditions: 20% diluted urine, 1-octanol of extraction solvent impregnated in the microporous membrane, 70 min extraction in pH 3.0 and 30 min with a mixture of 75% methanol and 25% acetonitrile (v/v) for the desorption. The R2 were ≤ 0.9973 for ibuprofen. The LOD ranged from 3.3 to 16.7 ng mL-1 and the LOQ from 10 to 50 ng mL-1. Relative recoveries ranged from 71% to 126%. The repeatability (n = 3) ranged from 0.22% to 12.01%, and the intermediate precision (n = 9) ranged from 0.13% to 17.76%. The method presents a good alternative for the determination of different classes of compounds in human urine.
Collapse
Affiliation(s)
- Maria Eduarda Pierri
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil
| | - Lucas Morés
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil
| | - Gabrieli Bernardi
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil
| | - Eduardo Carasek
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil.
| |
Collapse
|
3
|
Hou X, Tang S, Wang J. Recent advances and applications of graphene-based extraction materials in food safety. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.07.014] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
4
|
Chen K, Wang J, Li S, Wang Y, Zhang Y, Shen Q. High‐throughput 96‐well solid‐phase extraction for preparation of tetracycline followed by liquid chromatography and mass spectrometry analysis. Electrophoresis 2018; 40:555-562. [DOI: 10.1002/elps.201800473] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Revised: 12/01/2018] [Accepted: 12/02/2018] [Indexed: 11/07/2022]
Affiliation(s)
- Kang Chen
- The Joint Key Laboratory of Aquatic Products Processing of Zhejiang ProvinceInstitute of SeafoodZhejiang Gongshang University Hangzhou Zhejiang Province P. R. China
| | - Jie Wang
- The Joint Key Laboratory of Aquatic Products Processing of Zhejiang ProvinceInstitute of SeafoodZhejiang Gongshang University Hangzhou Zhejiang Province P. R. China
| | - Shiyan Li
- Aquatic Products Quality Inspection Center of Zhejiang Province Hangzhou P. R. China
| | - Yang Wang
- Aquatic Products Quality Inspection Center of Zhejiang Province Hangzhou P. R. China
| | - Yiqi Zhang
- The Joint Key Laboratory of Aquatic Products Processing of Zhejiang ProvinceInstitute of SeafoodZhejiang Gongshang University Hangzhou Zhejiang Province P. R. China
| | - Qing Shen
- The Joint Key Laboratory of Aquatic Products Processing of Zhejiang ProvinceInstitute of SeafoodZhejiang Gongshang University Hangzhou Zhejiang Province P. R. China
| |
Collapse
|
5
|
Hollow-fiber renewal liquid membrane extraction coupled with 96-well plate system as innovative high-throughput configuration for the determination of endocrine disrupting compounds by high-performance liquid chromatography-fluorescence and diode array detection. Anal Chim Acta 2018; 1040:33-40. [PMID: 30327111 DOI: 10.1016/j.aca.2018.07.032] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 07/09/2018] [Accepted: 07/16/2018] [Indexed: 11/23/2022]
Abstract
This paper describes a new configuration of the hollow fiber renewal liquid membrane (HFRLM) procedure for the high-throughput determination of the endocrine disrupting compounds 4-nonylphenol, 4-octylphenol, 4-tert-octylphenol, methylparaben, ethylparaben and bisphenol A using a 96-well plate system and high-performance liquid chromatography. In this configuration, cylindrical blades were adapted as a support for polypropylene membranes used as supported liquid membranes in the HFRLM approach. The proposed configuration exhibited important advantages including high-throughput, low solvent and sample consumption, and good analytical performance. The optimized extraction conditions were achieved with the use of a mixture comprised of 50:50 v/v 1-octanol:hexane as the supported liquid membrane, sample pH 5, extraction solvent 15 μL (hexane) and extraction time 45 min. The limits of quantification varied from 0.5 μg L-1 for 4-octylphenol to 15 μg L-1 for methylparaben and ethylparaben and the r2 ranged from 0.9908 for methylparaben to 0.9992 for 4-tert-octylphenol. HFRLM combined with the use of a 96-well plate provides an environmentally-friendly configuration. It offers good accuracy when applied to analyze water samples, with relative recoveries ranging from 72 to 130%, for 4-octylphenol and 4-nonylphenol, respectively, and precision varying from 1 to 14.3%, for 4-nonylphenol at 1.0 μg L-1 and bisphenol A at 8.0 μg L-1, respectively.
Collapse
|
6
|
The capillary gap sampler, a new microfluidic platform for direct coupling of automated solid-phase microextraction with ESI-MS. Anal Bioanal Chem 2017; 409:6873-6883. [DOI: 10.1007/s00216-017-0652-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 09/13/2017] [Accepted: 09/18/2017] [Indexed: 10/18/2022]
|
7
|
Rainville PD, Simeone JL, Root DS, Mallet CR, Wilson ID, Plumb RS. A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS. Analyst 2015; 140:1921-31. [DOI: 10.1039/c4an02090a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This methodology provides increased assay sensitivity and facilitates small volume biofluid analysis in high percent organic samples.
Collapse
Affiliation(s)
- Paul D. Rainville
- Waters Corporation
- Milford
- USA
- King's College London
- Micro Separations Group
| | | | | | | | - Ian D. Wilson
- Imperial College
- Division of Surgery and Cancer
- London
- UK
| | - Robert S. Plumb
- Waters Corporation
- Milford
- USA
- Imperial College
- Division of Surgery and Cancer
| |
Collapse
|
8
|
Hasnain MS, Rao S, Singh MK, Vig N, Singh MK, Budakoti SK, Ansari A. Development and validation of an improved LC-MS/MS method for the quantification of desloratadine and its metabolite in human plasma using deutrated desloratadine as internal standard. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2013; 5:74-9. [PMID: 23559828 PMCID: PMC3612343 DOI: 10.4103/0975-7406.106571] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2012] [Revised: 07/19/2012] [Accepted: 08/01/2012] [Indexed: 11/06/2022] Open
Abstract
Purpose: For the determination of desloratadine (DES) and 3-OH desloratadine (3-OHD) in human plasma using deutrated desloratadine (DESD5) as internal standard (IS), a novel stability indicating liquid chromatography-tandem mass spectrometric method was developed and validated to support the clinical advancement. Materials and Methods: The solid-phase extraction method used for sample preparation and calibration range was 100-11,000 pg/ml, for which a quadratic regression (1/x2) was best fitted. The blank plasma was screened and observed free from any endogenous interference. Results: The accuracy (% nominal) at low limit of quantification LLOQ level for DES and 3-OHD was 100.4% and 99.9% whereas precision (%CV) was 4.6 and 5.1%. They (DES and 3-OHD) were stable in human plasma after five freeze-thaw cycles, at room temperature for 23.8 hour, bench top stability for 6.4 hour. Conclusion: This method fulfills all the regulatory requirements for selectivity, sensitivity, precision, accuracy, stability, goodness of fit, and ruggedness of the method for the determination of DES and 3-OHD in human plasma.
Collapse
Affiliation(s)
- M Saquib Hasnain
- Department of Pharmaceutical Chemistry, Seemanta Institute of Pharmaceutical Sciences, Orissa, India
| | | | | | | | | | | | | |
Collapse
|
9
|
Rapid determination of sumatriptan in human plasma by ultra performance liquid chromatography–tandem mass spectrometry and its application to clinical pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 919-920:38-42. [DOI: 10.1016/j.jchromb.2013.01.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2012] [Revised: 12/20/2012] [Accepted: 01/03/2013] [Indexed: 11/19/2022]
|
10
|
Li S, Hao Q, Gounarides J, Wang YK. Full utilization of a mass spectrometer using on-demand sharing with multiple LC units. JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:1074-1082. [PMID: 22899517 DOI: 10.1002/jms.3061] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The applicability of liquid chromatography-mass spectrometry (LC/MS) is often limited by throughput. The sharing of a mass spectrometer with multiple LCs significantly improves throughput; however, the reported systems have not been designed to fully utilize the MS duty cycle, and as a result to achieve maximum throughput. To fully utilize the mass spectrometer, the number of LC units that a MS will need to recruit is application dependent and could be significantly larger than the current commercial or published implementations. For the example of a single analyte, the number may approach the peak capacity to a first degree approximation. Here, the construction of a MS system that flexibly recruits any number of LC units demanded by the application is discussed, followed by the method to port a previously developed LC/MS method to the system to fully utilize a mass spectrometer. To demonstrate the performance and operation, a prototypical MS system of eight LC units was constructed. When 1-min chromatographic separations were performed in parallel on the eight LCs of the system, the average LC/MS analysis time per sample was 10.5 s when applied to the analysis of samples in 384-well plate format. This system has been successfully used to conduct large-volume biochemical assays with the analysis of a variety of molecular entities in support of drug discovery efforts. Allowing the recruitment of the number of LC units appropriate for a given application, this system has the potential to be a plug-and-play system to fully utilize a mass spectrometer.
Collapse
Affiliation(s)
- Shu Li
- Analytical Sciences, Novartis Institutes for BioMedical Research, 250 Massachusetts Avenue, Cambridge, MA 02139, USA.
| | | | | | | |
Collapse
|
11
|
MARS: bringing the automation of small-molecule bioanalytical sample preparations to a new frontier. Bioanalysis 2012; 4:1311-26. [DOI: 10.4155/bio.12.77] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: In recent years, there has been a growing interest in automating small-molecule bioanalytical sample preparations specifically using the Hamilton MicroLab® STAR liquid-handling platform. In the most extensive work reported thus far, multiple small-molecule sample preparation assay types (protein precipitation extraction, SPE and liquid–liquid extraction) have been integrated into a suite that is composed of graphical user interfaces and Hamilton scripts. Using that suite, bioanalytical scientists have been able to automate various sample preparation methods to a great extent. However, there are still areas that could benefit from further automation, specifically, the full integration of analytical standard and QC sample preparation with study sample extraction in one continuous run, real-time 2D barcode scanning on the Hamilton deck and direct Laboratory Information Management System database connectivity. Results: We developed a new small-molecule sample-preparation automation system that improves in all of the aforementioned areas. Conclusion: The improved system presented herein further streamlines the bioanalytical workflow, simplifies batch run design, reduces analyst intervention and eliminates sample-handling error.
Collapse
|
12
|
Mirnaghi FS, Chen Y, Sidisky LM, Pawliszyn J. Optimization of the Coating Procedure for a High-Throughput 96-Blade Solid Phase Microextraction System Coupled with LC–MS/MS for Analysis of Complex Samples. Anal Chem 2011; 83:6018-25. [DOI: 10.1021/ac2010185] [Citation(s) in RCA: 126] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Fatemeh S. Mirnaghi
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Yong Chen
- Supelco Inc., 595 North Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Leonard M. Sidisky
- Supelco Inc., 595 North Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
13
|
Automated sample preparation for regulated bioanalysis: an integrated multiple assay extraction platform using robotic liquid handling. Bioanalysis 2010; 2:1023-40. [DOI: 10.4155/bio.10.55] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: A novel approach for regulated bioanalytical sample preparation has been developed to combine multiple types of extraction techniques into one integrated and automated sample-preparation suite that pairs a graphical user interface with the Hamilton Microlab® STAR robotic liquid handler. Results: The multi-assay sample-preparation suite is composed of three bioanalytical extraction techniques: protein precipitation, solid-phase extraction and liquid–liquid extraction. Validation data provided highly reproducible and robust results for each respective automated extraction technique. Conclusion: The user-friendly graphical user interface and modular method design provide a flexible and versatile approach for routine bioanalytical sample-preparation and is the first fully integrated multiple assay sample-preparation suite for regulated bioanalysis.
Collapse
|
14
|
A new approach to the application of solid phase extraction disks with LC–MS/MS for the analysis of drugs on a 96-well plate format. J Pharm Biomed Anal 2009; 50:556-62. [DOI: 10.1016/j.jpba.2008.07.014] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2008] [Accepted: 07/17/2008] [Indexed: 11/18/2022]
|
15
|
Roddy TP, Horvath CR, Stout SJ, Kenney KL, Ho PI, Zhang JH, Vickers C, Kaushik V, Hubbard B, Wang YK. Mass Spectrometric Techniques for Label-free High-Throughput Screening in Drug Discovery. Anal Chem 2007; 79:8207-13. [PMID: 17902631 DOI: 10.1021/ac062421q] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
High-throughput screening (HTS) is an important tool for finding active compounds to initiate medicinal chemistry programs in pharmaceutical discovery research. Traditional HTS methods rely on fluorescent or radiolabeled reagents and/or coupling assays to permit quantitation of enzymatic target inhibition or activation. Mass spectrometry-based high-throughput screening (MS-HTS) is an alternative that is not susceptible to the limitations imposed by labeling and coupling enzymes. MS-HTS offers a selective and sensitive analytical method for unlabeled substrates and products. Furthermore, method development times are reduced without the need to incorporate labels or coupling assays. MS-HTS also permits screening of targets that are difficult or impossible to screen by other techniques. For example, enzymes that are challenging to purify can lead to the nonspecific detection of structurally similar components of the impure enzyme or matrix of membraneous enzymes. The high selectivity of tandem mass spectrometry (MS/MS) enables these screens to proceed with low levels of background noise to sensitively discover interesting hits even with relatively weak activity. In this article, we describe three techniques that we have adapted for large-scale (approximately 175,000 sample) compound library screening, including four-way parallel multiplexed electrospray liquid chromatography tandem mass spectrometry (MUX-LC/MS/MS), four-way parallel staggered gradient liquid chromatography tandem mass spectrometry (LC/MS/MS), and eight-way staggered flow injection MS/MS following 384-well plate solid-phase extraction (SPE). These methods are capable of analyzing a 384-well plate in 37 min, with typical analysis times of less than 2 h. The quality of the MS-HTS approach is demonstrated herein with screening data from two large-scale screens.
Collapse
Affiliation(s)
- Thomas P Roddy
- Discovery Technologies, Novartis Institute for Biomedical Research, 250 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Tan A, Hang P, Couture J, Hussain S, Vallée F. An evaporation-free solid-phase extraction method for rapid and accurate analysis of sumatriptan in human plasma by LC–MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 856:9-14. [PMID: 17574939 DOI: 10.1016/j.jchromb.2007.05.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2007] [Revised: 05/04/2007] [Accepted: 05/11/2007] [Indexed: 11/23/2022]
Abstract
An evaporation-free solid-phase extraction (SPE) method was developed and validated for sumatriptan. High organic washing (50% methanol) and low organic elution (20% methanol) were used and the recovery was greater than 92%. The eluate was injected into a C18 column without evaporation and reconstitution. Sumatriptan was monitored in positive ion mode with mass transition of m/z 296.4-58.1 amu. The calibration curve was 1-100 ng/mL (r>or=0.9923). The inter-day and intra-day precisions ranged from 4.53 to 9.12% and 1.72 to 6.93%, respectively. This method features reduced cost and pollution, clean extract, high speed, and most importantly overall method reliability.
Collapse
Affiliation(s)
- Aimin Tan
- Anapharm, Richmond Hill, Ontario, Canada.
| | | | | | | | | |
Collapse
|
17
|
Wille SMR, Lambert WEE. Recent developments in extraction procedures relevant to analytical toxicology. Anal Bioanal Chem 2007; 388:1381-91. [PMID: 17468854 DOI: 10.1007/s00216-007-1294-z] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2007] [Revised: 04/03/2007] [Accepted: 04/04/2007] [Indexed: 10/23/2022]
Abstract
Sample preparation is an important step in the development of an analytical method but is often regarded as time-consuming, laborious work. Optimum sample preparation leads to enhanced selectivity and sensitivity, however, and reduces amounts of interfering matrix compounds, resulting in less signal suppression or enhancement. Recent developments in extraction techniques that could be of interest in clinical and forensic toxicology, for example liquid-liquid, solid-phase, and headspace extraction, are summarized in this review. The advantages and disadvantages of several extraction techniques are discussed, to enable the reader to choose an appropriate method of extraction for his or her application. Attention is paid to current trends in analytical toxicology, for example miniaturization, high throughput, and automation.
Collapse
Affiliation(s)
- Sarah M R Wille
- Laboratory of Toxicology, Ghent University, Harelbekestraat 72, 9000 Gent, Belgium
| | | |
Collapse
|
18
|
Bakhtiar R, Ramos L, Tse FLS. HIGH-THROUGHPUT MASS SPECTROMETRIC ANALYSIS OF XENOBIOTICS IN BIOLOGICAL FLUIDS. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-120008809] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- R. Bakhtiar
- a Novartis Institute for Biomedical Research , 59 Route 10, East Hanover, NJ, 07936, U.S.A
| | - Luis Ramos
- a Novartis Institute for Biomedical Research , 59 Route 10, East Hanover, NJ, 07936, U.S.A
| | - Francis L. S. Tse
- a Novartis Institute for Biomedical Research , 59 Route 10, East Hanover, NJ, 07936, U.S.A
| |
Collapse
|
19
|
Chang MS, Kim EJ, El-Shourbagy TA. Evaluation of 384-well formatted sample preparation technologies for regulated bioanalysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:64-72. [PMID: 17133627 DOI: 10.1002/rcm.2808] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The capabilities and limitations of 384-well formatted sample preparation technologies applied to regulated bioanalysis were evaluated by developing two assays for the simultaneous quantitation of lopinavir and ritonavir, the active ingredients of Kaletra. One method used liquid-liquid extraction (LLE), and the other used solid-phase extraction (SPE). The steps and apparatuses employed by the two methods covered most of those used for bioanalysis. Briefly, the previously validated 96-well formatted assays were adapted to the 384-format with minor modifications. Because the wells of a 384-well plate are clustered together, cross-contamination between adjacent wells was evaluated critically, along with sensitivity, assay throughput, and ruggedness. Samples (35 microL) containing plasma samples (15 microL), internal standard (10 microL), and sodium carbonate (0.5 M, 10 microL to basify the sample) were placed in a 384-well microtiter plate that may contain saquinavir or amprenavir as contamination markers. For LLE preparation, the samples were placed in a deep 384-well plate (300-microL well volume) and extracted with 150 microL of ethyl acetate. Approximately 50 microL of the extracts were removed from each well after phase separation for analysis. For SPE preparation, the fortified samples were transferred to a 384-formatted SPE plate (C18, 5 mg packing). The extracts were eluted from the plate with basified 2-propanol. The LLE or SPE extracts were dried and reconstituted for column-switching high-performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS). The lower limit of quantitation and the assay range were the same as the 96-well formatted assay. If combined with appropriate automation, sample preparation in the 384-well format would be up to five times more efficient than the 96-well format.
Collapse
Affiliation(s)
- Min S Chang
- Global Drug Analysis, Abbott Laboratories, 100 Abbott Park Road, IL 60064-6126, USA.
| | | | | |
Collapse
|
20
|
Xu N, Kim GE, Gregg H, Wagdy A, Swaine BA, Chang MS, El-Shourbagy TA. Automated 96-well liquid–liquid back extraction liquid chromatography–tandem mass spectrometry method for the determination of ABT-202 in human plasma. J Pharm Biomed Anal 2004; 36:189-95. [PMID: 15351065 DOI: 10.1016/j.jpba.2004.05.013] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2004] [Revised: 05/14/2004] [Accepted: 05/16/2004] [Indexed: 11/27/2022]
Abstract
A high-throughput bioanalytical method using automated sample transferring, automated liquid-liquid back extraction and liquid chromatography-tandem mass spectrometry was developed in a GLP regulated environment for the determination of ABT-202 in human plasma. Samples of 0.30 ml were transferred into 96-well plate using an automatic liquid handler. Automated liquid-liquid extraction (LLE) was carried out on a 96-channel programmable liquid handling workstation using methyl tert-butyl ether as the extraction solvent. A dual-HPLC with single mass spectrometer configuration was utilized to provide a reliable and routine means to increase sample throughput. The standard curve range was 0.38-95.02 ng/ml. There was no interference from endogenous components in the blank plasma tested. The accuracy (% bias) at the lower limit of quantitation (LLOQ) was 7.7% and the precision (% CV) for samples at the LLOQ was 4.7%. The inter-day % CV and % bias of the quality control samples were < or = 6.8 and < or = 7.6%, respectively. Coefficients of determination, a measure of linearity, ranged from 0.994 to 0.997. The method was accurate and reproducible and was successfully applied to generate plasma concentration-time profiles for human subjects after low oral doses of the compound.
Collapse
Affiliation(s)
- Naxing Xu
- Abbott Laboratories, Department of Clinical Drug Analysis, Dept. R46W, Bldg. AP13A-2, 100 Abbott Park Road, Abbott Park, IL 60064-6126, USA.
| | | | | | | | | | | | | |
Collapse
|
21
|
Go EP, Shen Z, Harris K, Siuzdak G. Quantitative Analysis with Desorption/Ionization on Silicon Mass Spectrometry Using Electrospray Deposition. Anal Chem 2003; 75:5475-9. [PMID: 14710827 DOI: 10.1021/ac034376h] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Desorption/ionization on silicon mass spectrometry (DIOS-MS) is demonstrated as a quantitative analytical tool when coupled to electrospray deposition (ESD). In this study, we illustrate the utility of DIOS-MS in the quantitative analysis of a peptide and two amino acids with deuterated and structural analogues used as internal standards. An important feature of this approach is the incorporation of ESD to improve sample homogeneity across the porous silicon surface. ESD allowed for a marked improvement in quantitative analysis due to its applicability to LC-DIOS, and because of the absence of matrix, sample can be deposited at very low flow rates (150 nL/min). Experiments comparing the traditional dried droplet and ESD methods show that ESD samples exhibit significantly improved quantitation and much higher sample-to-sample reproducibility.
Collapse
Affiliation(s)
- Eden P Go
- Department of Molecular Biology, The Scripps Center for Mass Spectrometry, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, California 92037, USA
| | | | | | | |
Collapse
|
22
|
Yang L, Clement RP, Kantesaria B, Reyderman L, Beaudry F, Grandmaison C, Di Donato L, Masse R, Rudewicz PJ. Validation of a sensitive and automated 96-well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the determination of desloratadine and 3-hydroxydesloratadine in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 792:229-40. [PMID: 12860030 DOI: 10.1016/s1570-0232(03)00267-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
To support clinical development, a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed and validated for the determination of desloratadine (descarboethoxyloratadine) and 3-OH desloratadine (3-hydroxydescarboethoxyloratadine) concentrations in human plasma. The method consisted of automated 96-well solid-phase extraction for sample preparation and liquid chromatography/turbo ionspray tandem mass spectrometry for analysis. [2H(4)]Desloratadine and [2H(4)]3-OH desloratadine were used as internal standards (I.S.). A quadratic regression (weighted 1/concentration(2)) gave the best fit for calibration curves over the concentration range of 25-10000 pg/ml for both desloratadine and 3-OH desloratadine. There was no interference from endogenous components in the blank plasma tested. The accuracy (%bias) at the lower limit of quantitation (LLOQ) was -12.8 and +3.4% for desloratadine and 3-OH desloratadine, respectively. The precision (%CV) for samples at the LLOQ was 15.1 and 10.9% for desloratadine and 3-OH desloratadine, respectively. For quality control samples at 75, 1000 and 7500 pg/ml, the between run %CV was </=7.5% for desloratadine and </=6.3% for 3-OH desloratadine. Between run %bias ranged from 4.1 to 8.0% for desloratadine and -11.5 to -4.8% for 3-OH desloratadine. Desloratadine and 3-OH desloratadine were stable in human plasma for 401 days at -22 degrees C, after five freeze/thaw cycles, up to 24 h at room temperature, and in reconstituted sample extracts (up to 185 h at 5 degrees C). This LC-MS-MS method for the determination of desloratadine and 3-OH desloratadine in human plasma met regulatory requirements for selectivity, sensitivity, goodness of fit, precision, accuracy and stability.
Collapse
Affiliation(s)
- Liyu Yang
- Schering-Plough Research Institute, 2015 Galloping Hill Road, Kenilworth, NJ 07033-1300, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Hopfgartner G, Bourgogne E. Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry. MASS SPECTROMETRY REVIEWS 2003; 22:195-214. [PMID: 12838545 DOI: 10.1002/mas.10050] [Citation(s) in RCA: 160] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
To support pharmacokinetic and drug metabolism studies, LC-MS/MS plays more and more an essential role for the quantitation of drugs and their metabolites in biological matrices. With the new challenges encountered in drug discovery and drug development, new strategies are put in place to achieve high-throughput analysis, using serial and parallel approaches. To speed-up method development and validation, generic approaches with the direct injection of biological fluids is highly desirable. Column-switching, using various packing materials for the extraction columns, is widely applied. Improvement of mass spectrometers performance, and in particular triple quadrupoles, also strongly influences sample preparation strategies, which remain a key element in the bioanalytical process.
Collapse
Affiliation(s)
- Gérard Hopfgartner
- University of Geneva, School of Pharmacy, Laboratory of Pharmaceutical Analytical Chemistry, Life Sciences Mass Spectrometry, 20 Bd d'Yvoy, CH-1211 Geneva 4, Switzerland
| | | |
Collapse
|
24
|
Chapter 5 Automation tools and strategies for bioanalysis. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s1464-3456(03)80007-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
25
|
Boulton DW, Duncan GF, Vachharajani NN. Validation and application of a high-performance liquid chromatography/tandem mass spectrometry assay for sumatriptan in human plasma. Biomed Chromatogr 2003; 17:48-52. [PMID: 12583006 DOI: 10.1002/bmc.211] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A sensitive and convenient high-performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS) assay is described for the (5-HT(lB/lD)) receptor agonist sumatriptan in human plasma. Sumatriptan was recovered from plasma (81.8 +/- 6.8%) by liquid-liquid extraction. The mobile phase flow rate was 0.3 mL/min and consisted of methanol:water:formic acid (90:10:0.1, v/v/v). The analytical column (4.6 x 100 mm) was packed with Partisil C(8) (5 micro m). The standard curve was linear from 0.7 to 70.4 ng/mL (r(2) > 0.99). The lower limit of quantitation was 0.7 ng/mL. The assay was specific, accurate (percentage deviation from nominal concentrations were <15%), precise and reproducible (within- and between-day coefficients of variation <10.3%). Sumatriptan in plasma was stable over three freeze/thaw cycles and at room temperature for one day. The utility of the assay was demonstrated by following sumatriptan plasma concentrations in two healthy subjects for 8-12 h following a single 20 mg intranasal dose.
Collapse
Affiliation(s)
- David W Boulton
- Clinical Discovery, Bristol-Myers Squibb Pharmaceutical Research Institute, Princeton, NJ 08543, USA.
| | | | | |
Collapse
|
26
|
Naidong W, Bu H, Chen YL, Shou WZ, Jiang X, Halls TDJ. Simultaneous development of six LC-MS-MS methods for the determination of multiple analytes in human plasma. J Pharm Biomed Anal 2002; 28:1115-26. [PMID: 12049976 DOI: 10.1016/s0731-7085(02)00002-x] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Traditional sequential single analyte method development is both time-consuming and labor-intensive. In this report, a concept of simultaneously developing multiple liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) methods were proposed. Mass spectrometric and chromatographic conditions as well as sample preparation methods for all analytes were optimized concurrently. Mass spectrometric conditions for six analytes, i.e. clonidine (CLO), albuterol (ALB), fentanyl (FEN), ritonavir (RIT), naltrexone (NAL), and loratadine (LOR), were established simultaneously using the Sciex Analyst software. LC-MS-MS sensitivities obtained using gradient elution methods on reversed-phase Inertsil ODS3 and normal phase Betasil silica columns were compared. Sample extraction methods using protein precipitation, liquid/liquid extraction, or solid-phase extraction (SPE) were evaluated. Recovery of analytes was determined. Matrix effects and interference due to endogenous compounds were investigated. Selection of a potential internal standard was discussed.
Collapse
Affiliation(s)
- Weng Naidong
- Bioanalytical Chemistry Department, Covance Laboratories, Inc., 3301 Kinsman Boulevard, Madison, WI 53704, USA.
| | | | | | | | | | | |
Collapse
|
27
|
Hopfgartner G, Husser C, Zell M. High-throughput quantification of drugs and their metabolites in biosamples by LC-MS/MS and CE-MS/MS: possibilities and limitations. Ther Drug Monit 2002; 24:134-43. [PMID: 11805734 DOI: 10.1097/00007691-200202000-00021] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Off-line solid phase extraction with C18 disk plates and turbulent flow chromatography were evaluated versus on-line solid phase extraction using column-switching HPLC as sample preparation techniques for high-throughput analysis of pharmaceutical compounds and their metabolites by LC-MS/MS. Turbulent flow chromatography was found to be very straightforward in its applicaton, but the LOQs were more than fivefold higher compared with off-line or other on-line solid phase extraction methods. Solid phase extraction (SPE) on disk was found to be fast and sufficient efficient to minimize matrix effects and therefore an apprach to provide sensitive and reliable LC-MS/MS methods. Column-switching HPLC with microbore columns (0.5 mm i.d.) were used for fast analysis of a parent drug and four of its metabolites utilizing steep gradients in 1 minute. The application of CZE-MS/MS for bionalysis of pharamaceutical compounds is also discussed.
Collapse
Affiliation(s)
- G Hopfgartner
- F. Hoffmann-La Roche Ltd., Pharmaceuticals Division, Non-Clinical Development Drug Safety, Bld 68/142, CH-4070 Basel, Switzerland.
| | | | | |
Collapse
|
28
|
Sancho JV, Pozo OJ, López FJ, Hernández F. Different quantitation approaches for xenobiotics in human urine samples by liquid chromatography/electrospray tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:639-645. [PMID: 11921240 DOI: 10.1002/rcm.617] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.
Collapse
Affiliation(s)
- Juan V Sancho
- Analytical Chemistry, Experimental Sciences Department, ESTCE, University Jaume I, E-12071, Castellón, Spain
| | | | | | | |
Collapse
|
29
|
Chapter 24 Automation of sample preparation for pharmaceutical and clinical analysis. ACTA ACUST UNITED AC 2002. [DOI: 10.1016/s0166-526x(02)80061-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
30
|
King RC, Miller-Stein C, Magiera DJ, Brann J. Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:43-52. [PMID: 11754246 DOI: 10.1002/rcm.539] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The Aria LX4 staggered parallel high performance liquid chromatography (HPLC) system is evaluated for application to good laboratory practice (GLP) level quantitative analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS). This system consists of four fully independent binary HPLC pumps, a modified autosampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Validation results for four different compounds, each analyzed on a separate channel of the Aria system, show precision and accuracy equivalent to that required of a single-channel system. The results show that sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The flexibility and ease of use of the Aria system suggest that it should be possible to quickly implement it in any analytical LC/MS/MS environment.
Collapse
Affiliation(s)
- Richard C King
- Department of Drug Metabolism, Merck and Co., Inc., West Point, PA 19486, USA.
| | | | | | | |
Collapse
|
31
|
Plumb RS, Dear GJ, Mallett DN, Higton DM, Pleasance S, Biddlecombe RA. Quantitative analysis of pharmaceuticals in biological fluids using high-performance liquid chromatography coupled to mass spectrometry: a review. Xenobiotica 2001; 31:599-617. [PMID: 11569528 DOI: 10.1080/00498250110060941] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
1. The development of bio-analysis of drug molecules over the last 10 years is reviewed, focusing on advances in sample preparation, liquid chromatography and detection. 2. Developments have led to improvements in detection sensitivity, enhancements in specificity and increased capacity. 3. Emerging technologies such as monolithic column chromatography and miniaturized chip-based systems are discussed.
Collapse
Affiliation(s)
- R S Plumb
- Department of Bioanalysis and Drug Metabolism, GlaxoWellcome R&D, Ware, UK
| | | | | | | | | | | |
Collapse
|
32
|
Current awareness. Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:581-588. [PMID: 11391815 DOI: 10.1002/jms.92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of mass spectrometry. Each bibliography is divided into 11 sections: 1 Books, Reviews & Symposia; 2 Instrumental Techniques & Methods; 3 Gas Phase Ion Chemistry; 4 Biology/Biochemistry: Amino Acids, Peptides & Proteins; Carbohydrates; Lipids; Nucleic Acids; 5 Pharmacology/Toxicology; 6 Natural Products; 7 Analysis of Organic Compounds; 8 Analysis of Inorganics/Organometallics; 9 Surface Analysis; 10 Environmental Analysis; 11 Elemental Analysis. Within each section, articles are listed in alphabetical order with respect to author (3 Weeks journals - Search completed at 7th. Mar. 2001)
Collapse
|
33
|
Shou WZ, Jiang X, Beato BD, Naidong W. A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2001; 15:466-476. [PMID: 11268130 DOI: 10.1002/rcm.255] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, has been developed for the determination of the analgesic fentanyl in human plasma. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction (SPE) was carried out using a 96-channel programmable liquid-handling workstation using a mixed-mode sorbent. The extracted samples were then dried down, reconstituted and injected onto a silica column using an aqueous/organic mobile phase with tandem mass spectrometric detection. The method has been validated over the concentration range 0.05-100 ng/mL fentanyl in human plasma, based on a 0.25-mL sample size. The assay is sensitive, specific and robust. More than 2000 samples have been analyzed using this method. The automation of the sample preparation steps not only increased the analysis throughput, but also facilitated the transfer of the method between different bioanalytical laboratories of the same organization.
Collapse
Affiliation(s)
- W Z Shou
- Bioanalytical Chemistry, Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, Wisconsin 53704, USA
| | | | | | | |
Collapse
|
34
|
He H, Kramp R, Ramos L, Bakhtiar R. A preliminary study on the feasibility of an automated blood-sampling system in conjunction with liquid chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2001; 15:1768-1772. [PMID: 11555879 DOI: 10.1002/rcm.418] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|