1
|
Pinto EC, Dolzan MD, Cabral LM, Armstrong DW, de Sousa VP. Topiramate: a review of analytical approaches for biological matrices. Biomed Chromatogr 2015; 29:1461-72. [DOI: 10.1002/bmc.3466] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Revised: 02/25/2015] [Accepted: 02/26/2015] [Indexed: 12/14/2022]
Affiliation(s)
- Eduardo Costa Pinto
- Department of Pharmaceutics, Faculty of Pharmacy; Federal University of Rio de Janeiro; Rio de Janeiro RJ Brazil
- Department of Chemistry and Biochemistry; University of Texas at Arlington; Arlington Texas USA
| | - Maressa Danielli Dolzan
- Department of Chemistry and Biochemistry; University of Texas at Arlington; Arlington Texas USA
- Department of Chemistry; Federal University of Santa Catarina; Florianopolis SC Brazil
| | - Lucio Mendes Cabral
- Department of Pharmaceutics, Faculty of Pharmacy; Federal University of Rio de Janeiro; Rio de Janeiro RJ Brazil
| | - Daniel W. Armstrong
- Department of Chemistry and Biochemistry; University of Texas at Arlington; Arlington Texas USA
| | - Valéria Pereira de Sousa
- Department of Pharmaceutics, Faculty of Pharmacy; Federal University of Rio de Janeiro; Rio de Janeiro RJ Brazil
| |
Collapse
|
2
|
Popov TV, Maričič LC, Prosen H, Vončina DB. Development and validation of dried blood spots technique for quantitative determination of topiramate using liquid chromatography-tandem mass spectrometry. Biomed Chromatogr 2013; 27:1054-61. [PMID: 23529887 DOI: 10.1002/bmc.2905] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Revised: 02/17/2013] [Accepted: 02/18/2013] [Indexed: 11/06/2022]
Abstract
An LC-MS/MS method for determination of the anti-epileptic drug topiramate (TPM) in dried blood spot (DBS) samples was developed and validated. DBS samples were prepared by spotting 30 μL of spiked whole blood onto FTA(TM) DMPK-C cards and drying for at least 3 h. Six-millimetre punched spots were then extracted by using a mixture of methanol and water (90:10, v/v) with deuterated internal standard (topiramate-d12). The extracted samples were injected into a liquid chromatograph equipped with a tandem mass spectrometric detector. Negative ions were monitored in the selected reaction monitoring mode and transitions m/z 338.2 → 78.1 and m/z 350.3 → 78.1 were used for the quantitative evaluation of TPM and internal standard, respectively. The results obtained from validation were statistically evaluated according to the requirements of the European Medicines Agency and US Food and Drug Administration regulatory guidelines. The linearity of the method was checked within a concentration range from 10 to 2000 ng/mL. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible.
Collapse
|
3
|
Conway JM, Birnbaum AK, Marino SE, Cloyd JC, Remmel RP. A sensitive capillary GC-MS method for analysis of topiramate from plasma obtained from single-dose studies. Biomed Chromatogr 2012; 26:1071-6. [PMID: 22223467 DOI: 10.1002/bmc.1749] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2011] [Accepted: 10/06/2011] [Indexed: 11/08/2022]
Abstract
Topiramate (Topamax®) is an antiepileptic medication used as adjunctive and monotherapy in patients with epilepsy and for migraine prophylaxis. A GC-MS assay was developed that was capable of detecting topiramate plasma concentrations following a single rectal or oral dose administration. Topiramate plasma samples were prepared by solid-phase extraction and were quantified by GC-MS analysis. The topiramate standard curves were split from 0.1 to 4 µg/mL and from 4 to 40 µg/mL in order to give a more accurate determination of the topiramate concentration. The accuracy of the standards ranged from 94.6 to 107.3% and the precision (%CV) ranged from 1.0 to 5.3% for both curves at all concentrations. The %CV for quality controls was <7.6%. The assay is both accurate and precise and will be used to complete future pharmacokinetic studies.
Collapse
Affiliation(s)
- Jeannine M Conway
- Experimental and Clinical Pharmacology, College of Pharmacy, University of Minnesota, Minneapolis, MN, USA
| | | | | | | | | |
Collapse
|
4
|
Salama NN, El Ries MA, Toubar S, Abd El Hamid M, Walash MI. Thermoanalytical investigation of some sulfone-containing drugs. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2012; 2012:439082. [PMID: 22792516 PMCID: PMC3389717 DOI: 10.1155/2012/439082] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2011] [Revised: 02/13/2012] [Accepted: 02/20/2012] [Indexed: 05/03/2023]
Abstract
The thermal behavior of some sulfone-containing drugs, namely, dapsone (DDS), dimethylsulfone (MSM), and topiramate (TOP) in drug substances, and products were investigated using different thermal techniques. These include thermogravimetry (TGA), derivative thermogravimetry (DTG), differential thermal analysis (DTA), and differential scanning calorimetry (DSC). The thermogravimetric data allowed the determination of the kinetic parameters: activation energy (E(a)), frequency factor (A), and reaction order (n). The thermal degradation of dapsone and topiramate was followed a first-order kinetic behavior. The calculated data evidenced a zero-order kinetic for dimethylsulfone. The relative thermal stabilities of the studied drugs have been evaluated and follow the order DDS > TOP > MSM. The purity was determined using DSC for the studied compounds, in drug substances and products. The results were in agreement with the recommended pharmacopoeia and manufacturer methods. DSC curves obtained from the tablets suggest compatibility between the drugs, excipients and/or coformulated drugs. The fragmentation pathway of dapsone with mass spectrometry was taken as example, to correlate the thermal decomposition with the resulted MS-EI. The decomposition modes were investigated, and the possible fragmentation pathways were suggested by mass spectrometry.
Collapse
Affiliation(s)
- Nahla N. Salama
- Pharmaceutical Chemistry Department, National Organization for Drug Control and Research, Pyramids Avenue, P.O. Box 29, Giza, Egypt
- *Nahla N. Salama:
| | - Mohammed A. El Ries
- Pharmaceutical Chemistry Department, National Organization for Drug Control and Research, Pyramids Avenue, P.O. Box 29, Giza, Egypt
| | - Safaa Toubar
- Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Cairo 1860, Egypt
| | - Maha Abd El Hamid
- Pharmaceutical Chemistry Department, National Organization for Drug Control and Research, Pyramids Avenue, P.O. Box 29, Giza, Egypt
| | - Mohammed I. Walash
- Analytical Chemistry Department, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt
| |
Collapse
|
5
|
Kang J, Park YS, Kim SH, Kim SH, Jun MY. Modern methods for analysis of antiepileptic drugs in the biological fluids for pharmacokinetics, bioequivalence and therapeutic drug monitoring. THE KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY : OFFICIAL JOURNAL OF THE KOREAN PHYSIOLOGICAL SOCIETY AND THE KOREAN SOCIETY OF PHARMACOLOGY 2011; 15:67-81. [PMID: 21660146 DOI: 10.4196/kjpp.2011.15.2.67] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Revised: 04/10/2011] [Accepted: 04/15/2011] [Indexed: 12/20/2022]
Abstract
Epilepsy is a chronic disease occurring in approximately 1.0% of the world's population. About 30% of the epileptic patients treated with availably antiepileptic drugs (AEDs) continue to have seizures and are considered therapy-resistant or refractory patients. The ultimate goal for the use of AEDs is complete cessation of seizures without side effects. Because of a narrow therapeutic index of AEDs, a complete understanding of its clinical pharmacokinetics is essential for understanding of the pharmacodynamics of these drugs. These drug concentrations in biological fluids serve as surrogate markers and can be used to guide or target drug dosing. Because early studies demonstrated clinical and/or electroencephalographic correlations with serum concentrations of several AEDs, It has been almost 50 years since clinicians started using plasma concentrations of AEDs to optimize pharmacotherapy in patients with epilepsy. Therefore, validated analytical method for concentrations of AEDs in biological fluids is a necessity in order to explore pharmacokinetics, bioequivalence and TDM in various clinical situations. There are hundreds of published articles on the analysis of specific AEDs by a wide variety of analytical methods in biological samples have appears over the past decade. This review intends to provide an updated, concise overview on the modern method development for monitoring AEDs for pharmacokinetic studies, bioequivalence and therapeutic drug monitoring.
Collapse
Affiliation(s)
- Juseop Kang
- Pharmacology & Clinical Pharmacology Lab, College of Medicine, Hanyang University, Seoul 133-791, Korea
| | | | | | | | | |
Collapse
|
6
|
Kuchekar SR, Zaware BH, Kundlik ML. A simple, rapid and specific method for measurement of topiramate in human plasma by LC-MS/MS employing automated solid-phase extraction techniques: Application for bioequivalence study. J Sep Sci 2010:n/a-n/a. [PMID: 21166024 DOI: 10.1002/jssc.201000668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A rapid liquid chromatography coupled with ESI tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of topiramate in heparinized human plasma. The plasma samples were prepared by solid-phase extraction (SPE) method without drying and then reconstitution. Topiramate and the topiramate d-12 internal standard (IS) were chromatographed on a Betasil C18 column at a flow rate of 0.5 mL/min. The total run time was 1.80 min. An ESI interface with negative ion mode was selected for ionization of analyte and IS. The mass transition [M-H] ions used for detection were m/z 338.10→78.20 for topiramate, m/z 350.40→90.10 for IS. The method was linear in the concentration range of 10-4200 ng/mL with r≥0.9992. Recovery of topiramate and IS ranged from 78.20 to 87.74%. The validated method has been successfully used to analyze human plasma samples for application in 100 mg fasted and fed pharmacokinetic studies.
Collapse
Affiliation(s)
- Shashikant R Kuchekar
- Padmashri Vikhe Patil College, Pravaranagar, Loni Kurd, Dis-Ahmednagar, Maharashtra State, India
| | | | | |
Collapse
|
7
|
Matar KM. Therapeutic drug monitoring of topiramate by liquid chromatography-tandem mass spectrometry. Clin Chim Acta 2010; 411:729-34. [DOI: 10.1016/j.cca.2010.02.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2010] [Revised: 02/01/2010] [Accepted: 02/02/2010] [Indexed: 11/17/2022]
|
8
|
Goswami D, Kumar A, Khuroo AH, Monif T, Rab S. Bioanalytical LC-MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers. Biomed Chromatogr 2009; 23:1227-41. [DOI: 10.1002/bmc.1273] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
9
|
Manera M, Miró M, Ribeiro MFT, Estela JM, Cerdà V, Santos JLM, Lima JLFC. Rapid chemiluminometric determination of gabapentin in pharmaceutical formulations exploiting pulsed-flow analysis. LUMINESCENCE 2009; 24:10-4. [DOI: 10.1002/bio.1055] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
10
|
Patsalos PN, Berry DJ, Bourgeois BFD, Cloyd JC, Glauser TA, Johannessen SI, Leppik IE, Tomson T, Perucca E. Antiepileptic drugs--best practice guidelines for therapeutic drug monitoring: a position paper by the subcommission on therapeutic drug monitoring, ILAE Commission on Therapeutic Strategies. Epilepsia 2008; 49:1239-76. [PMID: 18397299 DOI: 10.1111/j.1528-1167.2008.01561.x] [Citation(s) in RCA: 708] [Impact Index Per Article: 44.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Although no randomized studies have demonstrated a positive impact of therapeutic drug monitoring (TDM) on clinical outcome in epilepsy, evidence from nonrandomized studies and everyday clinical experience does indicate that measuring serum concentrations of old and new generation antiepileptic drugs (AEDs) can have a valuable role in guiding patient management provided that concentrations are measured with a clear indication and are interpreted critically, taking into account the whole clinical context. Situations in which AED measurements are most likely to be of benefit include (1) when a person has attained the desired clinical outcome, to establish an individual therapeutic concentration which can be used at subsequent times to assess potential causes for a change in drug response; (2) as an aid in the diagnosis of clinical toxicity; (3) to assess compliance, particularly in patients with uncontrolled seizures or breakthrough seizures; (4) to guide dosage adjustment in situations associated with increased pharmacokinetic variability (e.g., children, the elderly, patients with associated diseases, drug formulation changes); (5) when a potentially important pharmacokinetic change is anticipated (e.g., in pregnancy, or when an interacting drug is added or removed); (6) to guide dose adjustments for AEDs with dose-dependent pharmacokinetics, particularly phenytoin.
Collapse
Affiliation(s)
- Philip N Patsalos
- Institute of Neurology/The National Hospital for Neurology and Neurosurgery, London and The Chalfont Centre for Epilepsy, Chalfont St Peter, United Kingdom.
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Park JH, Park YS, Lee MH, Rhim SY, Song JC, Lee SJ, Kim JM, Shaw LM, Kang JS. Determination of plasma topiramate concentration using LC-MS/MS for pharmacokinetic and bioequivalence studies in healthy Korean volunteers. Biomed Chromatogr 2008; 22:822-9. [DOI: 10.1002/bmc.995] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
12
|
|
13
|
Britzi M, Soback S, Isoherranen N, Levy RH, Perucca E, Doose DR, Maryanoff BE, Bialer M. Analysis of topiramate and its metabolites in plasma and urine of healthy subjects and patients with epilepsy by use of a novel liquid chromatography-mass spectrometry assay. Ther Drug Monit 2003; 25:314-22. [PMID: 12766560 DOI: 10.1097/00007691-200306000-00012] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A novel liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for quantification of topiramate (TPM) and its metabolites 10-hydroxy topiramate (10-OH-TPM), 9-hydroxy topiramate (9-OH-TPM), and 4,5-O-desisopropylidene topiramate (4,5-diol-TPM) in plasma and urine. The method uses 0.5 mL of plasma or 1 mL of urine that is extracted with diethyl ether and analyzed by LC-MS. Positive ion mode detection enables tandem mass spectrometric (MS/MS) identification of the aforementioned four compounds. Calibration curves of TPM, 4,5-diol-TPM, 9-OH-TPM, and 10-OH-TPM in plasma and urine were prepared and validated over the concentration range of 0.625 to 40 microg/mL using TPM-d(12) as an internal standard. Calibration curves were linear over this concentration range for TPM and its metabolites. Accuracy and precision ranged in urine from 83% to 114% and 4% to 13% (%CV), respectively, and in plasma from 82% to 108% and 6% to 13%, respectively. The applicability of the assay was evaluated by analyzing plasma samples from a healthy subject who received a single oral dose of TPM (200 mg) and urine samples from 11 patients with epilepsy treated with TPM (daily dose between 100 to 600 mg) alone or with other antiepileptic drugs. Only TPM was detected and quantified in the plasma samples, and its concentration ranged between 0.7 and 4.3 microg/mL. The concentrations of TPM and 10-OH TPM were quantifiable in all urine samples and ranged from 20 to 300 microg/mL for TPM and from 1 to 50 microg/mL for 10-OH-TPM. The metabolites 4,5-diol-TPM and 9-OH-TPM were also detected in all urine samples, but their concentrations were quantifiable only in 4 patients. An unidentified peak in the chromatograms obtained from patients' urine was attributed to 2,3-O-desisopropylidene topiramate (2,3-diol-TPM). Due to a lack of reference material of 2,3-diol TPM and the similar MS/MS spectrum with 4,5-diol-TPM, the calibration curves of 4,5-diol-TPM were used for the quantification of its isomer 2,3-diol-TPM. Based on these determinations, the apparent 2,3-diol-TPM-to-TPM concentration ratio in patients' urine ranged from 0.05 to 0.51 and the 10-OH-TPM-to-TPM ratio ranged from 0.02 to 0.17. In conclusion, a novel LC-MS method for the assay of TPM and four of its metabolites in plasma and urine was developed. Its utilization for analysis of urine samples from patients with epilepsy showed that the method was suitable for analysis of TPM and its metabolites in clinical samples. Two quantitatively significant TPM metabolites (10-OH-TPM and 2,3-diol-TPM) and two quantitatively minor metabolites (9-OH-TPM and 4,5-diol-TPM) were detected and quantified in urine samples from patients with epilepsy.
Collapse
Affiliation(s)
- Malka Britzi
- Department of Pharmaceutics, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Johannessen SI, Battino D, Berry DJ, Bialer M, Krämer G, Tomson T, Patsalos PN. Therapeutic drug monitoring of the newer antiepileptic drugs. Ther Drug Monit 2003; 25:347-63. [PMID: 12766564 DOI: 10.1097/00007691-200306000-00016] [Citation(s) in RCA: 224] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The aim of the present review is to discuss the potential value of therapeutic drug monitoring (TDM) of the newer antiepileptic drugs (AEDs) felbamate, gabapentin, lamotrigine, levetiracetam, oxcarbazepine, tiagabine, topiramate, vigabatrin, and zonisamide. Studies of the relationship between serum concentrations and clinical efficacy of these drugs are reviewed, and the potential value of TDM of the drugs is discussed based on their pharmacokinetic properties and mode of action. Analytical methods for the determination of the serum concentrations of these drugs are also briefly described. There are only some prospective data on the serum concentration-effect relationships, and few studies have been designed primarily to study these relationships. As TDM is not widely practiced for the newer AEDs, there are no generally accepted target ranges for any of these drugs, and for most a wide range in serum concentration is associated with clinical efficacy. Furthermore, a considerable overlap in drug concentrations related to toxicity and nonresponse is reported. Nevertheless, the current tentative target ranges for felbamate, gabapentin, lamotrigine, levetiracetam, oxcarbazepine (10-hydroxy-carbazepine metabolite), tiagabine, topiramate, vigabatrin, and zonisamide are 125 to 250 micromol/L, 70 to 120 micromol/L, 10 to 60 micromol/L, 35 to 120 micromol/L, 50 to 140 micomol/L, 50 to 250 nmol/L, 15 to 60 micromol/L, 6 to 278 micromol/L, and 45 to 180 micromol/L, respectively. Further systematic studies designed specifically to evaluate concentration-effect relationships of the new AEDs are urgently needed. Although routine monitoring in general cannot be recommended at present, measurements of some of the drugs is undoubtedly of help with individualization of treatment in selected cases in a particular clinical setting.
Collapse
Affiliation(s)
- Svein I Johannessen
- The National Center for Epilepsy, Sandvika, Norway, "Carlo Besta", Milan, Italy.
| | | | | | | | | | | | | |
Collapse
|
15
|
Hopfgartner G, Bourgogne E. Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry. MASS SPECTROMETRY REVIEWS 2003; 22:195-214. [PMID: 12838545 DOI: 10.1002/mas.10050] [Citation(s) in RCA: 160] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
To support pharmacokinetic and drug metabolism studies, LC-MS/MS plays more and more an essential role for the quantitation of drugs and their metabolites in biological matrices. With the new challenges encountered in drug discovery and drug development, new strategies are put in place to achieve high-throughput analysis, using serial and parallel approaches. To speed-up method development and validation, generic approaches with the direct injection of biological fluids is highly desirable. Column-switching, using various packing materials for the extraction columns, is widely applied. Improvement of mass spectrometers performance, and in particular triple quadrupoles, also strongly influences sample preparation strategies, which remain a key element in the bioanalytical process.
Collapse
Affiliation(s)
- Gérard Hopfgartner
- University of Geneva, School of Pharmacy, Laboratory of Pharmaceutical Analytical Chemistry, Life Sciences Mass Spectrometry, 20 Bd d'Yvoy, CH-1211 Geneva 4, Switzerland
| | | |
Collapse
|
16
|
Christensen J, Højskov CS, Poulsen JH. Liquid chromatography tandem mass spectrometry assay for topiramate analysis in plasma and cerebrospinal fluid: validation and comparison with fluorescence-polarization immunoassay. Ther Drug Monit 2002; 24:658-64. [PMID: 12352939 DOI: 10.1097/00007691-200210000-00013] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
SUMMARY The authors report the development and validation of a liquid chromatography tandem mass spectrometry assay (LC/MS/MS assay) for the analysis of topiramate (2,3:4,5-bis-o-(-1-methyl)-beta-D-fructopyranose sulfamate) in plasma and cerebrospinal fluid (CSF). Comparison is made with the commercially available fluorescence-polarization immunoassay (FPIA). LC/MS/MS ASSAY Using the internal standard, 1,2:3,4-bis-o-(1-methylethylidene-alpha-D-galactopyranose sulfamate), a structural isomer, the calibration curve in plasma was linear in the concentration range of 0.02-20.0 mg/L (r(2) = 0.9998). The coefficients of variation in plasma were < or = 3%, and the accuracy ranged from 100% to 101% in the therapeutically relevant concentration range of 0.4-16.0 mg/L. In CSF, the mean recovery was 98%, and there was linearity between the nominal and the estimated concentration in the range of 1.5-20.0 mg/L (r(2)= 0.9996). FPIA: The calibration curve was linear in the concentration interval of 1.6-24.3 mg/L (r(2) = 0.9994), and the mean recovery was 96%. Accuracy in plasma was 99- 104%, and precision was 3.2-6.0%. In CSF, there was linearity between the nominal concentration and the estimated concentration in the range of 1.5-20.0 mg/L (r(2) = 0.9995), and the mean recovery was 100%. COMPARISON BETWEEN FPIA AND LC/MS/MS: There was a high correlation between the FPIA and the LC/MS/MS assay (r(2) = 0.9965 in plasma and r(2) = 0.9996 in CSF, P < 0.001 for both). In plasma and CSF, the two methods showed equal results, evaluated as the ratio between the two methods (plasma: median ratio = 1.00; 95% confidence interval [CI], 0.98-1.02, paired-sample test, P = 0.79; and CSF: median ratio = 1.00, 95% CI, 0.99-1.02, paired-sample test, P = 0.75). The coefficient of variation on the ratios between the two methods had similar levels: 5% in plasma and 3% in CSF. CONCLUSION The new LC/MS/MS assay has favorable characteristics, being highly precise and accurate. FPIA also proved precise and accurate, and there was a high agreement with the LC/MS/MS assay in plasma and CSF. Either method displayed sufficient precision and accuracy and may thus be implemented in daily routine.
Collapse
Affiliation(s)
- Jakob Christensen
- Department of Clinical Pharmacology, Aarhus University Hospital, Aarhus, Denmark.
| | | | | |
Collapse
|
17
|
King RC, Miller-Stein C, Magiera DJ, Brann J. Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:43-52. [PMID: 11754246 DOI: 10.1002/rcm.539] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The Aria LX4 staggered parallel high performance liquid chromatography (HPLC) system is evaluated for application to good laboratory practice (GLP) level quantitative analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS). This system consists of four fully independent binary HPLC pumps, a modified autosampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Validation results for four different compounds, each analyzed on a separate channel of the Aria system, show precision and accuracy equivalent to that required of a single-channel system. The results show that sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The flexibility and ease of use of the Aria system suggest that it should be possible to quickly implement it in any analytical LC/MS/MS environment.
Collapse
Affiliation(s)
- Richard C King
- Department of Drug Metabolism, Merck and Co., Inc., West Point, PA 19486, USA.
| | | | | | | |
Collapse
|
18
|
Contin M, Riva R, Albani F, Baruzzi A. Simple and rapid liquid chromatographic-turbo ion spray mass spectrometric determination of topiramate in human plasma. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 761:133-7. [PMID: 11585128 DOI: 10.1016/s0378-4347(01)00302-4] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We present a simple and fast method for the determination of the novel antiepileptic drug topiramate in human plasma by high-performance liquid chromatography coupled with turbo ion spray mass spectrometry. Plasma sample pre-treatment was based on simple deproteinization by acetonitrile. Liquid chromatographic analysis was carried out on a reversed-phase column (C18, 125x4 mm I.D., 5 microm) using acetonitrile-ammonium acetate buffer, pH 6.3 as the mobile phase, at a flow-rate of 0.8 ml/min. Retention time for topiramate was 2.1 min. The detector was a single quadrupole mass spectrometer coupled to a turbo ion spray ion source and a heated nebulizer probe, operating in the positive ion mode. Ion source temperature was off; voltage was +5800 V; nebulizer and curtain gas flow-rates were 6 and 10 ml/min, respectively. Calibration curves for topiramate were linear over the range 1 to 20 microg/ml. Absolute recovery ranged between 92 and 95%. Intra- and inter-assay precision was <4%. The present procedure, omitting extraction and drying steps, is faster and simpler than the previously reported analytical methods for topiramate and was demonstrated to possess adequate sensitivity for routine therapeutic drug monitoring in plasma from patients with epilepsy.
Collapse
Affiliation(s)
- M Contin
- Laboratory of Clinical Neuropharmacology, Institute of Neurology, University of Bologna, Italy.
| | | | | | | |
Collapse
|
19
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:446-457. [PMID: 11333450 DOI: 10.1002/jms.91] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|