1
|
Elashery SE, Attia NF, Oh H. Design and fabrication of novel flexible sensor based on 2D Ni-MOF nanosheets as a preliminary step toward wearable sensor for onsite Ni (II) ions detection in biological and environmental samples. Anal Chim Acta 2022; 1197:339518. [DOI: 10.1016/j.aca.2022.339518] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 01/07/2022] [Accepted: 01/17/2022] [Indexed: 11/27/2022]
|
2
|
Al Zoubi W, Al Mohanna N. Membrane sensors based on Schiff bases as chelating ionophores--a review. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2014; 132:854-870. [PMID: 24947440 DOI: 10.1016/j.saa.2014.04.176] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Revised: 04/24/2014] [Accepted: 04/30/2014] [Indexed: 06/03/2023]
Abstract
The development of chemical sensors has received widespread attention during the past two decades because of their extensive use in environmental monitoring and clinical analysis via rapid, accurate, reproducible, and low-cost methods. Chemically modified CPEs have frequently been employed as potentiometric sensors in trace analysis for metal ions, organic pollutants and biological substances. Most of these electrodes are operated via the ion-exchange process of the active component incorporated into the carbon paste matrix. This review article concentrates on such achievements in the context of the general development across the field. An overview of potentiometric sensors that are capable of detecting metal ions in environmental samples is presented and discussed. A survey on important advances in potentiometric sensors with regard to high selectivity, lower detection limit, and fast response time is presented in this review article.
Collapse
Affiliation(s)
- Wail Al Zoubi
- Department of Chemistry, Faculty of Science, University of Damascus, Syria.
| | - NaDeem Al Mohanna
- Department of Chemistry, Faculty of Science, University of Damascus, Syria
| |
Collapse
|
3
|
Tomar PK, Chandra S, Malik A, Kumar A. Nickel analysis in real samples by Ni2+ selective PVC membrane electrode based on a new Schiff base. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:4978-84. [PMID: 24094213 DOI: 10.1016/j.msec.2013.08.019] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2013] [Revised: 07/10/2013] [Accepted: 08/18/2013] [Indexed: 11/30/2022]
Abstract
A newly synthesized Schiff base 3-aminoacetophenonesemicarbazone (AAS) has been used for the preparation of Ni(2+) selective PVC membrane electrode. The proposed electrode exhibits a Nernstian response over the nickel concentration range of 1.0×10(-7) to 1.0×10(-2)mol L(-1) with a slope of 30.0±0.3 mV/decade of concentration. The limit of detection as determined from the intersection linear segment of the calibration plot is 5.1×10(-8) mol L(-1). The electrode shows good selectivity towards nickel with respect to several alkali, alkaline earth, transition and heavy metal ions. The response time of the electrode is very fast (≥10 s) and can be used for 17 weeks in the pH range of 2.0-9.8. The electrode can also be used in partially non-aqueous media having up to 20% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working concentration range. To investigate the analytical applicability of the electrode, it was successfully applied as an indicator electrode in Ni(2+) ion potentiometric titration with EDTA, and in direct determination of nickel(II) in real samples.
Collapse
Affiliation(s)
- Praveen Kumar Tomar
- Department of Chemistry, Zakir Husain Delhi College, University of Delhi, J. L. Nehru Marg, New Delhi, 110002, India.
| | | | | | | |
Collapse
|
4
|
Sheikhshoaie I, Shamspur T, Yousef Ebrahimipur S. Asymmetric Schiff base as carrier in PVC membrane electrodes for manganese (II) ions. ARAB J CHEM 2012. [DOI: 10.1016/j.arabjc.2010.08.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
5
|
Faridbod F, Norouzi P, Dinarvand R, Ganjali MR. Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade. SENSORS (BASEL, SWITZERLAND) 2008; 8:2331-2412. [PMID: 27879825 PMCID: PMC3673421 DOI: 10.3390/s8042331] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2008] [Accepted: 04/02/2008] [Indexed: 12/07/2022]
Abstract
Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed.
Collapse
Affiliation(s)
- Farnoush Faridbod
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Parviz Norouzi
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Rassoul Dinarvand
- Medical Nanotechnology Research Centre, Medical Sciences/University of Tehran, Tehran, P.O. Box 14155-6451, Iran
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran.
| |
Collapse
|
6
|
Zamani H, Abedini-Torghabeh J, Ganjali M. A Highly Selective and Sensitive Barium(II)-Selective PVC Membrane Based on Dimethyl 1-Acetyl-8-oxo-2,8-dihydro- 1H-pyra-zolo[5,1-a]isoindole-2,3-dicarboxylate. ELECTROANAL 2006. [DOI: 10.1002/elan.200503472] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
7
|
Ganjali MR, Norouzi P, Faridbod F, Ghorbani M, Adib M. Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2006.03.105] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
Zamani HA, Malekzadegan F, Ganjali MR. Highly selective and sensitive thiocyanate membrane electrode based on nickel(II)-1,4,8,11,15,18,22,25-octabutoxyphthalocyanine. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.09.026] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Zamani H, Rajabzadeh G, Ganjali M, Khatami S. Highly Selective and Sensitive Copper(II) Membrane Sensors Based on 6-Methyl-4-(1-phenylmethylidene)amino-3-thioxo-1,2,4-triazin-5-one as a New Neutral Ionophore. ELECTROANAL 2005. [DOI: 10.1002/elan.200503356] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
10
|
Singh A, Saxena P, Panwar A. Copper Incorporated [Me2(15)dieneN4] Macrocyclic Complex for Fabrication of PVC based Membrane Electrode for Copper. J INCL PHENOM MACRO 2005. [DOI: 10.1007/s10847-005-9006-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
11
|
Ganjali M, Akbar V, Norouzi P, Moghimi A, Sepehrifard A. Be(II) Graphite Coated Membrane Sensor Based on a Recently Synthesized Benzo-9-Crown-3 Derivative. ELECTROANAL 2005. [DOI: 10.1002/elan.200303169] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
12
|
Zn2+PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one. B KOREAN CHEM SOC 2005. [DOI: 10.5012/bkcs.2005.26.4.579] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
13
|
Ganjali MR, Daftari A, Faal-Rastegar M, Moghimi A. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3. ANAL SCI 2003; 19:353-6. [PMID: 12675338 DOI: 10.2116/analsci.19.353] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A novel poly(vinyl chloride) (PVC) membrane electrode based on naphto-9-crown-3 was prepared and tested for the selective detection of beryllium ions. A suitable lipophilicity of the carrier and appropriate coordination ability were found to be essential for designing an electrode with good response characteristics. A PVC membrane with 9% naphtho-9-crown-3 carrier, 58% o-NPOE plasticizer, 3% tetraphenylborate anionic excluder and 30% poly(vinyl chloride) satisfied these requirements. The proposed sensor displayed a linear response to beryllium over a wide concentration range of 1.0 x 10(-1)-8.0 x 10(-6) M with a Nernstian slope of 29.5 mV per decade. The electrode showed very short response time (<15 s) and could be used in the pH range 3.5-9.0. The selectivity coefficient for alkali, alkaline earth, transition and heavy metal ions was smaller than 4.0 x 10(-4). The sensor was successfully used as an indicator electrode in the potentiometric titration of Be2+ with EDTA. The proposed Be(II) sensor was also used for the determination of Be2+ ions in binary mixtures.
Collapse
|
14
|
Ganjali MR, Emami M, Salavati-Niasari M, Yousefi M. Determination of Trace Amounts of Cr(III) in Presence of Cr(VI) by a Novel Potentiometric Membrane Sensor Based on a New Tridentate S,N,O Schiff's Base. ANAL LETT 2003. [DOI: 10.1081/al-120025252] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
15
|
Ganjali MR, Kiani R, Yousefi M, Faal-Rastegar M. Novel Potentiometric Strontium Membrane Sensor Based on Dibenzo-30-crown-10. ANAL LETT 2003. [DOI: 10.1081/al-120023706] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
16
|
Ganjali MR, Tahami M, Poursaberi T, Pazoukian AR, Javanbakht M, Shamsipur M, Baezat MR. Novel Bromide Liquid Membrane Electrode. ANAL LETT 2003. [DOI: 10.1081/al-120017695] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
17
|
Ganjali MR, Naji L, Poursaberi T, Shamsipur M, Haghgoo S. Ytterbium(III)-selective membrane electrode based on cefixime. Anal Chim Acta 2003. [DOI: 10.1016/s0003-2670(02)01226-6] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
18
|
|
19
|
Poursaberi T, Hosseini M, Taghizadeh M, Pirelahi H, Shamsipur M, Ganjali MR. A selective membrane electrode for iodide ion based on a thiopyrilium ion derivative as a new ionophore. Microchem J 2002. [DOI: 10.1016/s0026-265x(01)00159-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
20
|
Ganjali MR, Poursaberi T, Hosseini M, Salavati-Niasary M, Yousefi M, Shamsipur M. Highly selective iodide membrane electrode based on a cerium salen. ANAL SCI 2002; 18:289-92. [PMID: 11918187 DOI: 10.2116/analsci.18.289] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detection limit of 6.0 x 10(-6) M. The electrode has a very fast response time and can be used in the pH range of 3.0 - 1 1.0. It was applied, as an indicator electrode, in potentiometric titration of Ag+ ions.
Collapse
|
21
|
Poursaberi T, Hajiagha-Babaei L, Yousefi M, Rouhani S, Shamsipur M, Kargar-Razi M, Moghimi A, Aghabozorg H, Ganjali MR. The Synthesis of a New Thiophene-Derivative Schiff's Base and Its Use in Preparation of Copper-Ion Selective Electrodes. ELECTROANAL 2001. [DOI: 10.1002/1521-4109(200112)13:18<1513::aid-elan1513>3.0.co;2-x] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
|