• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604935)   Today's Articles (4503)   Subscriber (49371)
For: Jadhav S, Meir AJ, Bakker E. Normal Pulse Voltammetry as Improved Quantitative Detection Mode for Amperometric Solvent Polymeric Membrane Ion Sensors. ELECTROANAL 2000. [DOI: 10.1002/1521-4109(200011)12:16<1251::aid-elan1251>3.0.co;2-p] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Number Cited by Other Article(s)
1
Nikitina VN, Maksimova ED, Zavolskova MD, Karyakin AA. Flow injection amperometry as an alternative to potentiometry for solid contact ion-selective membrane-based electrodes. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
2
Khataee A, Sohrabi H, Arbabzadeh O, Khaaki P, Majidi MR. Frontiers in conventional and nanomaterials based electrochemical sensing and biosensing approaches for Ochratoxin A analysis in foodstuffs: A review. Food Chem Toxicol 2021;149:112030. [DOI: 10.1016/j.fct.2021.112030] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 01/19/2021] [Accepted: 01/24/2021] [Indexed: 12/22/2022]
3
Flavin MT, Freeman DK, Han J. Interfacial ion transfer and current limiting in neutral-carrier ion-selective membranes: A detailed numerical model. J Memb Sci 2019. [DOI: 10.1016/j.memsci.2018.10.065] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
4
Afshar MG, Crespo GA, Dorokhin D, Néel B, Bakker E. Thin Layer Coulometry of Nitrite with Ion-Selective Membranes. ELECTROANAL 2015. [DOI: 10.1002/elan.201400522] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
5
Crespo GA, Bakker E. Dynamic electrochemistry with ionophore based ion-selective membranes. RSC Adv 2013. [DOI: 10.1039/c3ra43751e] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
6
Ion amperometry at the interface between two immiscible electrolyte solutions in view of realizing the amperometric ion-selective electrode. Talanta 2012;63:21-32. [PMID: 18969401 DOI: 10.1016/j.talanta.2003.11.023] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2003] [Revised: 11/07/2003] [Accepted: 11/18/2003] [Indexed: 11/24/2022]
7
Pulsed chronopotentiometric membrane electrodes based on plasticized poly(vinyl chloride) with covalently bound ferrocene functionalities as solid contact transducer. PURE APPL CHEM 2012. [DOI: 10.1351/pac-con-11-09-23] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
8
Grygolowicz-Pawlak E, Numnuam A, Thavarungkul P, Kanatharana P, Bakker E. Interference Compensation for Thin Layer Coulometric Ion-Selective Membrane Electrodes by the Double Pulse Technique. Anal Chem 2012;84:1327-35. [DOI: 10.1021/ac202273k] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
9
Molina Á, Serna C, Ortuño JA, Torralba E. Studies of ion transfer across liquid membranes by electrochemical techniques. ACTA ACUST UNITED AC 2012. [DOI: 10.1039/c2pc90005j] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
10
Cheng C, Tian X, Guo Y, Li Y, Yuan H, Xiao D. Large enhancement of sensitivity and a wider working range of glass pH electrode with amperometric and potentiometric responses. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.08.065] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
11
Gemene KL, Meyerhoff ME. Detection of protease activities by flash chronopotentiometry using a reversible polycation-sensitive polymeric membrane electrode. Anal Biochem 2011;416:67-73. [PMID: 21601559 PMCID: PMC3125491 DOI: 10.1016/j.ab.2011.04.036] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 04/20/2011] [Accepted: 04/23/2011] [Indexed: 10/18/2022]
12
Pawlak M, Grygolowicz-Pawlak E, Bakker E. Ferrocene Bound Poly(vinyl chloride) as Ion to Electron Transducer in Electrochemical Ion Sensors. Anal Chem 2010;82:6887-94. [DOI: 10.1021/ac1010662] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
13
Grygolowicz-Pawlak E, Bakker E. Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes. Anal Chem 2010;82:4537-42. [DOI: 10.1021/ac100524z] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
14
Zook JM, Lindner E. Reverse Current Pulse Method To Restore Uniform Concentration Profiles in Ion-Selective Membranes. 2. Comparison of the Efficiency of the Different Protocols. Anal Chem 2009;81:5155-64. [DOI: 10.1021/ac802065h] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
15
Gemene KL, Bakker E. Flash chronopotentiometric sensing of the polyions protamine and heparin at ion-selective membranes. Anal Biochem 2009;386:276-81. [DOI: 10.1016/j.ab.2008.12.023] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2008] [Revised: 12/12/2008] [Accepted: 12/20/2008] [Indexed: 10/21/2022]
16
Michalska A, Pyrzyńska K, Maksymiuk K. Method of achieving desired potentiometric responses of polyacrylate-based ion-selective membranes. Anal Chem 2008;80:3921-4. [PMID: 18380468 DOI: 10.1021/ac8000622] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
17
Fordyce K, Shvarev A. Solid-Contact Electrochemical Polyion Sensors for Monitoring Peptidase Activities. Anal Chem 2007;80:827-33. [DOI: 10.1021/ac701775n] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
18
Makarychev-Mikhailov S, Shvarev A, Bakker E. Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range. Anal Chem 2007;78:2744-51. [PMID: 16615788 DOI: 10.1021/ac052211y] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
19
Ortuño JA, Serna C, Molina A, Gil A. Differential pulse voltammetry and additive differential pulse voltammetry with solvent polymeric membrane ion sensors. Anal Chem 2007;78:8129-33. [PMID: 17134149 DOI: 10.1021/ac061224o] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
20
Gemene KL, Shvarev A, Bakker E. Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometry. Anal Chim Acta 2006;583:190-6. [PMID: 17386545 PMCID: PMC1826444 DOI: 10.1016/j.aca.2006.09.042] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2006] [Revised: 09/20/2006] [Accepted: 09/22/2006] [Indexed: 11/20/2022]
21
Pawłowski P, Michalska A, Maksymiuk K. Galvanostatic Polarization of All-Solid-State K+-Selective Electrodes with Polypyrrole Ion-to-Electron Transducer. ELECTROANAL 2006. [DOI: 10.1002/elan.200603553] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
22
Flow-injection pulse amperometric detection based on ion transfer across a water-plasticized polymeric membrane interface for the determination of verapamil. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.08.041] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
23
Influence of cationic and anionic additives on the electrical properties of ionophore-based ion-selective membranes. J Electroanal Chem (Lausanne) 2005. [DOI: 10.1016/j.jelechem.2005.04.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
24
Xu Y, De Marco R, Shvarev A, Bakker E. Reversible electrochemical monitoring of surface confined reactions at liquid-liquid interfaces by modulation of ion transfer fluxes. Chem Commun (Camb) 2005:3074-6. [PMID: 15959589 DOI: 10.1039/b503548a] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
25
Makarychev-Mikhailov S, Shvarev A, Bakker E. Pulstrodes: triple pulse control of potentiometric sensors. J Am Chem Soc 2004;126:10548-9. [PMID: 15327306 DOI: 10.1021/ja047728q] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
26
Sutter J, Morf WE, de Rooij NF, Pretsch E. Current response of ion-selective solvent polymeric membranes at controlled potential. J Electroanal Chem (Lausanne) 2004. [DOI: 10.1016/j.jelechem.2004.04.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
27
Shvarev A, Bakker E. Pulsed Galvanostatic Control of Ionophore-Based Polymeric Ion Sensors. Anal Chem 2003;75:4541-50. [PMID: 14632062 DOI: 10.1021/ac034409t] [Citation(s) in RCA: 97] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
28
Lo CK, Choi MM. Symmetrical electrochemical cell for determination of coextraction constants of metal salts for ion-selective polymeric membranes. Anal Chim Acta 2003. [DOI: 10.1016/s0003-2670(03)00420-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA