1
|
Kim WC, Won YK, Lee SM, Heo NH, Yeo SG, Chang AR, Bae SH, Kim JS, Yoo ID, Hong SP, Min CK, Jo IY, Kim ES. Evaluating the Necessity of Adaptive RT and the Role of Deformable Image Registration in Lung Cancer with Different Pathologic Classifications. Diagnostics (Basel) 2023; 13:2956. [PMID: 37761323 PMCID: PMC10527903 DOI: 10.3390/diagnostics13182956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/07/2023] [Accepted: 09/09/2023] [Indexed: 09/29/2023] Open
Abstract
BACKGROUND This study aimed to analyze differential radiotherapy (RT) responses according to the pathological type of lung cancer to see the possibility of applying adaptive radiotherapy (ART). METHODS ART planning with resampled-computed tomography was conducted for a total of 30 patients (20 non-small-cell lung cancer patients and 10 small-cell lung cancer patients) using a deformable image registration technique to reveal gross tumor volume (GTV) changes according to the duration of RT. RESULTS The small-cell lung cancer group demonstrated an average GTV reduction of 20.95% after the first week of initial treatment (p = 0.001), whereas the adenocarcinoma and squamous cell carcinoma groups showed an average volume reduction of 20.47% (p = 0.015) and 12.68% in the second week. The application of ART according to the timing of GTV reduction has been shown to affect changes in radiation dose irradiated to normal tissues. This suggests that ART applications may have to be different depending on pathological differences in lung cancer. CONCLUSION Through these results, the present study proposes the possibility of personalized treatment options for individual patients by individualizing ART based on specific radiation responses by pathologic types of lung cancer.
Collapse
Affiliation(s)
- Woo Chul Kim
- Department of Radiation Oncology, Division of Medical Physics, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea; (W.C.K.); (C.K.M.)
- Department of Radiation Oncology, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea;
| | - Yong Kyun Won
- Department of Radiation Oncology, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea;
| | - Sang Mi Lee
- Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea; (S.M.L.); (I.D.Y.); (S.-p.H.)
| | - Nam Hun Heo
- Clinical Trial Center, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea;
| | - Seung-Gu Yeo
- Department of Radiation Oncology, Soonchunhyang University Bucheon Hospital, 170, Jomaru-ro, Bucheon 14584, Republic of Korea; (S.-G.Y.); (S.H.B.)
| | - Ah Ram Chang
- Department of Radiation Oncology, Soonchunhyang University Seoul Hospital, 59, Daesagwan-ro, Yongsan-gu, Seoul 04401, Republic of Korea; (A.R.C.); (J.S.K.)
| | - Sun Hyun Bae
- Department of Radiation Oncology, Soonchunhyang University Bucheon Hospital, 170, Jomaru-ro, Bucheon 14584, Republic of Korea; (S.-G.Y.); (S.H.B.)
| | - Jae Sik Kim
- Department of Radiation Oncology, Soonchunhyang University Seoul Hospital, 59, Daesagwan-ro, Yongsan-gu, Seoul 04401, Republic of Korea; (A.R.C.); (J.S.K.)
| | - Ik Dong Yoo
- Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea; (S.M.L.); (I.D.Y.); (S.-p.H.)
| | - Sun-pyo Hong
- Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea; (S.M.L.); (I.D.Y.); (S.-p.H.)
| | - Chul Kee Min
- Department of Radiation Oncology, Division of Medical Physics, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea; (W.C.K.); (C.K.M.)
- Department of Radiation Oncology, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea;
| | - In Young Jo
- Department of Radiation Oncology, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea;
| | - Eun Seog Kim
- Department of Radiation Oncology, Soonchunhyang University Cheonan Hospital, 31, Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea;
| |
Collapse
|
2
|
Suitability of propagated contours for adaptive replanning for head and neck radiotherapy. Phys Med 2022; 102:66-72. [DOI: 10.1016/j.ejmp.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 08/19/2022] [Accepted: 09/12/2022] [Indexed: 11/20/2022] Open
|
3
|
Rathee S, Burke B, Heikal A. Comparison of Three Commercial Methods of Cone-Beam Computed Tomography-Based Dosimetric Analysis of Head-and-Neck Patients with Weight Loss. J Med Phys 2022; 47:344-351. [PMID: 36908500 PMCID: PMC9997542 DOI: 10.4103/jmp.jmp_7_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 08/27/2022] [Accepted: 09/02/2022] [Indexed: 01/11/2023] Open
Abstract
Purpose This investigation compares three commercial methods of cone-beam computed tomography (CBCT)-based dosimetric analysis to a method based on repeat computed tomography (CT). Materials and Methods Seventeen head-and-neck patients treated in 2020, and with a repeat CT, were included in the analyses. The planning CT was deformed to anatomy in repeat CT to generate a reference plan. Two of the CBCT-based methods generated test plans by deforming the planning CT to CBCT of fraction N using VelocityAI™ and SmartAdapt®. The third method compared directly calculated doses on the CBCT for fraction 1 and fraction N, using PerFraction™. Maximum dose to spinal cord (Cord_dmax) and dose to 95% volume (D95) of planning target volumes (PTVs) were used to assess "need to replan" criteria. Results The VelocityAI™ method provided results that most accurately matched the reference plan in "need to replan" criteria using either Cord_dmax or PTV D95. SmartAdapt® method overestimated the change in Cord_dmax (6.77% vs. 3.85%, P < 0.01) and change in cord volume (9.56% vs. 0.67%, P < 0.01) resulting in increased false positives in "need to replan" criteria, and performed similarly to VelocityAI™ for D95, but yielded more false negatives. PerFraction™ method underestimated Cord_dmax, did not perform any volume deformation, and missed all "need to replan" cases based on cord dose. It also yielded high false negatives using the D95 PTV criteria. Conclusions The VelocityAI™-based method using fraction N CBCT is most similar to the reference plan using repeat CT; the other two methods had significant differences.
Collapse
Affiliation(s)
- Satyapal Rathee
- Department of Oncology, University of Alberta, Edmonton, Alberta, Canada
- Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta, Canada
| | - Benjamin Burke
- Department of Oncology, University of Alberta, Edmonton, Alberta, Canada
- Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta, Canada
| | - Amr Heikal
- Department of Oncology, University of Alberta, Edmonton, Alberta, Canada
- Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta, Canada
| |
Collapse
|
4
|
Nash D, Juneja S, Palmer AL, van Herk M, McWilliam A, Osorio EV. The geometric and dosimetric effect of algorithm choice on propagated contours from CT to cone beam CTs. Phys Med 2022; 100:112-119. [DOI: 10.1016/j.ejmp.2022.06.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 05/17/2022] [Accepted: 06/28/2022] [Indexed: 11/17/2022] Open
|
5
|
Adaptive radiation therapy: When, how and what are the benefits that literature provides? Cancer Radiother 2021; 26:622-636. [PMID: 34688548 DOI: 10.1016/j.canrad.2021.08.023] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 08/21/2021] [Accepted: 08/24/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE To identify from the current literature when is the right time to replan and to assign thresholds for the optimum process of replanning. Nowadays, adaptive radiotherapy (ART) for head and neck cancer plays an exceptional role consisting of an evaluation procedure of the prominent anatomical and dosimetric variations. By performing complex radiotherapy methods, the credibility of the therapeutic result is crucial. Image guided radiotherapy (IGRT) was developed to ensure locoregional control and thus changes that might occur during radiotherapy be dealt with. MATERIALS AND METHODS An electronic research of articles published in PubMed/MEDLINE and Science Direct databases from January 2004 to October 2020 was performed. Among a total of 127 studies assessed for eligibility, 85 articles were ultimately retained for the review. RESULTS The most noticeable changes have been reported in the middle fraction of the treatment. Therefore, the suggested optimal time to replan is between the third and the fourth week. Anatomical deviations>1cm in the external contour, average weight loss>10%, violation in the dose coverage of the targets>5%, and violation in the dose of the peripherals were some of the thresholds that are currently used, and which lead to replanning. CONCLUSION ART may decrease toxicity and improve local-control. Whether it is beneficial or not, depends ultimately on each patient. However, more investigation of the changes should be performed in future prospective studies to obtain more accurate results.
Collapse
|
6
|
Hamming-Vrieze O, van Kranen S, Walraven I, Navran A, Al-Mamgani A, Tesselaar M, van den Brekel M, Sonke JJ. Deterioration of Intended Target Volume Radiation Dose Due to Anatomical Changes in Patients with Head-and-Neck Cancer. Cancers (Basel) 2021; 13:cancers13174253. [PMID: 34503061 PMCID: PMC8428222 DOI: 10.3390/cancers13174253] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/11/2021] [Accepted: 08/18/2021] [Indexed: 11/16/2022] Open
Abstract
Delivered radiation dose can differ from intended dose. This study quantifies dose deterioration in targets, identifies predictive factors, and compares dosimetric to clinical patient selection for adaptive radiotherapy in head-and-neck cancer patients. One hundred and eighty-eight consecutive head-and-neck cancer patients treated up to 70 Gy were analyzed. Daily delivered dose was calculated, accumulated, and compared to the planned dose. Cutoff values (1 Gy/2 Gy) were used to assess plan deterioration in the highest/lowest dose percentile (D1/D99). Differences in clinical factors between patients with/without dosimetric deterioration were statistically tested. Dosimetric deterioration was evaluated in clinically selected patients for adaptive radiotherapy with CBCT. Respectively, 16% and 4% of patients had deterioration over 1 Gy in D99 and D1 in any of the targets, this was 5% (D99) and 2% (D1) over 2 Gy. Factors associated with deterioration of D99 were higher baseline weight/BMI, weight gain early in treatment, and smaller PTV margins. The sensitivity of visual patient selection with CBCT was 22% for detection of dosimetric changes over 1 Gy. Large dose deteriorations in targets occur in a minority of patients. Clinical prediction based on patient characteristics or CBCT is challenging and dosimetric selection tools seem warranted to identify patients in need for ART, especially in treatment with small PTV margins.
Collapse
Affiliation(s)
- Olga Hamming-Vrieze
- Department of Radiation Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands; (S.v.K.); (I.W.); (A.N.); (A.A.-M.); (J.-J.S.)
- Correspondence:
| | - Simon van Kranen
- Department of Radiation Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands; (S.v.K.); (I.W.); (A.N.); (A.A.-M.); (J.-J.S.)
| | - Iris Walraven
- Department of Radiation Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands; (S.v.K.); (I.W.); (A.N.); (A.A.-M.); (J.-J.S.)
| | - Arash Navran
- Department of Radiation Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands; (S.v.K.); (I.W.); (A.N.); (A.A.-M.); (J.-J.S.)
| | - Abrahim Al-Mamgani
- Department of Radiation Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands; (S.v.K.); (I.W.); (A.N.); (A.A.-M.); (J.-J.S.)
| | - Margot Tesselaar
- Department of Medical Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands;
| | - Michiel van den Brekel
- Department of Head and Neck Surgery, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands;
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands; (S.v.K.); (I.W.); (A.N.); (A.A.-M.); (J.-J.S.)
| |
Collapse
|
7
|
Iliadou V, Economopoulos TL, Karaiskos P, Kouloulias V, Platoni K, Matsopoulos GK. Deformable image registration to assist clinical decision for radiotherapy treatment adaptation for head and neck cancer patients. Biomed Phys Eng Express 2021; 7. [PMID: 34265756 DOI: 10.1088/2057-1976/ac14d1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 07/15/2021] [Indexed: 11/12/2022]
Abstract
Head and neck (H&N) cancer patients often present anatomical and geometrical changes in tumors and organs at risk (OARs) during radiotherapy treatment. These changes may result in the need to adapt the existing treatment planning, using an expert's subjective opinion, for offline adaptive radiotherapy and a new treatment planning before each treatment, for online adaptive radiotherapy. In the present study, a fast methodology is proposed to assist in planning adaptation clinical decision using tumor and parotid glands percentage volume changes during treatment. The proposed approach was applied to 40 Η&Ν cases, with one planning Computed Tomography (pCT) image and CBCT scans for 6 weeks of treatment per case. Deformable registration was used for each patient's pCT image alignment to its weekly CBCT. The calculated transformations were used to align each patient's anatomical structures to the weekly anatomy. Clinical target volume (CTV) and parotid gland volume percentage changes were calculated in each case. The accuracy of the achieved image alignment was validated qualitatively and quantitatively. Furthermore, statistical analysis was performed to test if there is a statistically significant correlation between CTV and parotid glands volume percentage changes. Average MDA for CTV and parotid glands between corresponding structures defined by an expert in CBCTs and automatically calculated through registration was 1.4 ± 0.1 mm and 1.5 ± 0.1 mm, respectively. The mean registration time of the first CBCT image registration for 40 cases was lower than 3.4 min. Five patients show more than 20% tumor volume change. Six patients show more than 30% parotid glands volume change. Ten out of 40 patients proposed for planning adaptation. All the statistical tests performed showed no correlation between CTV/parotid glands percentage volume changes. The aim to assist in clinical decision making on a fast and automatic way was achieved using the proposed methodology, thereby reducing workload in clinical practice.
Collapse
Affiliation(s)
- Vasiliki Iliadou
- School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| | - Theodore L Economopoulos
- School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| | - Pantelis Karaiskos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Vasileios Kouloulias
- 2nd Department of Radiology, Radiotherapy Unit, ATTIKON University Hospital, Athens, Greece
| | - Kalliopi Platoni
- 2nd Department of Radiology, Radiotherapy Unit, ATTIKON University Hospital, Athens, Greece
| | - George K Matsopoulos
- School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| |
Collapse
|
8
|
Schaly B, Kempe J, Venkatesan V, Mitchell S, Chen J. Alert system for monitoring changes in patient anatomy during radiation therapy of head and neck cancer. J Appl Clin Med Phys 2021; 22:168-174. [PMID: 34302421 PMCID: PMC8364268 DOI: 10.1002/acm2.13342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 05/20/2021] [Accepted: 06/05/2021] [Indexed: 01/29/2023] Open
Abstract
The purpose of this study is to validate a previously developed algorithm for alerting clinicians when to consider re-CT simulation due to changes in the patient's anatomy during radiation therapy of head and neck cancer. Cone beam computed tomography (CBCT) data were collected prospectively for 77 patients. Each CBCT was mathematically compared to a reference CBCT using the gamma index. We defined the match quality parameter (MQP) as an indicator of CBCT image similarity, where a negative MQP value indicates a poorer CBCT match than the match between the first two CBCT acquired during treatment. If three consecutive MQP values were below a chosen threshold, an "alert" is triggered to indicate action required, for example, possible re-CT simulation. The timing of image review requests made by the radiation therapists and any re-CT/re-plan decisions were documented for each patient's treatment course. The MQP for each patient (including any re-plans) was calculated in a manner that was blinded from the clinical process. The MQP as a function of fraction number was compared to actual clinical decisions in the treatment progress to evaluate alert system performance. There was a total of 93 plans (including re-plans) with 34 positives (action required) and 59 negatives (no action required). The sensitivity of the alert system was 0.76 and the false positive rate was 0.37. Only 1 case out of the 34 positive cases would have been missed by both the alert system and our clinical process. Despite the false negatives and false positives, analysis of the timing of alert triggers showed that the alert system could have resulted in seven fewer clinical misses. The alert system has the potential to be a valuable tool to complement human judgment and to provide a quality assurance safeguard to help improve the delivery of radiation treatment of head and neck cancer.
Collapse
Affiliation(s)
- Bryan Schaly
- Physics & Engineering Department, London Regional Cancer Program, London, ON, Canada
| | - Jeff Kempe
- Physics & Engineering Department, London Regional Cancer Program, London, ON, Canada
| | - Varagur Venkatesan
- Department of Radiation Oncology, London Regional Cancer Program, London, ON, Canada
| | - Sylvia Mitchell
- Department of Radiation Oncology, London Regional Cancer Program, London, ON, Canada
| | - Jeff Chen
- Departments of Oncology and Medical Biophysics, Western University, London, ON, Canada
| |
Collapse
|
9
|
Morgan HE, Sher DJ. Adaptive radiotherapy for head and neck cancer. CANCERS OF THE HEAD & NECK 2020; 5:1. [PMID: 31938572 PMCID: PMC6953291 DOI: 10.1186/s41199-019-0046-z] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Accepted: 11/11/2019] [Indexed: 12/14/2022]
Abstract
Background Although there have been dramatic improvements in radiotherapy for head and neck squamous cell carcinoma (HNSCC), including robust intensity modulation and daily image guidance, these advances are not able to account for inherent structural and spatial changes that may occur during treatment. Many sources have reported volume reductions in the primary target, nodal volumes, and parotid glands over treatment, which may result in unintended dosimetric changes affecting the side effect profile and even efficacy of the treatment. Adaptive radiotherapy (ART) is an exciting treatment paradigm that has been developed to directly adjust for these changes. Main body Adaptive radiotherapy may be divided into two categories: anatomy-adapted (A-ART) and response-adapted ART (R-ART). Anatomy-adapted ART is the process of re-planning patients based on structural and spatial changes occurring over treatment, with the intent of reducing overdosage of sensitive structures such as the parotids, improving dose homogeneity, and preserving coverage of the target. In contrast, response-adapted ART is the process of re-planning patients based on response to treatment, such that the target and/or dose changes as a function of interim imaging during treatment, with the intent of dose escalating persistent disease and/or de-escalating surrounding normal tissue. The impact of R-ART on local control and toxicity outcomes is actively being investigated in several currently accruing trials. Conclusions Anatomy-adapted ART is a promising modality to improve rates of xerostomia and coverage in individuals who experience significant volumetric changes during radiation, while R-ART is currently being studied to assess its utility in either dose escalation of radioresistant disease, or de-intensification of surrounding normal tissue following treatment response. In this paper, we will review the existing literature and recent advances regarding A-ART and R-ART.
Collapse
Affiliation(s)
- Howard E Morgan
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, 2280 Inwood Rd, Dallas, TX 75390 USA
| | - David J Sher
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, 2280 Inwood Rd, Dallas, TX 75390 USA
| |
Collapse
|
10
|
Belshaw L, Agnew CE, Irvine DM, Rooney KP, McGarry CK. Adaptive radiotherapy for head and neck cancer reduces the requirement for rescans during treatment due to spinal cord dose. Radiat Oncol 2019; 14:189. [PMID: 31675962 PMCID: PMC6825357 DOI: 10.1186/s13014-019-1400-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Accepted: 10/16/2019] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Patients treated with radiotherapy for head and neck (H&N) cancer often experience anatomical changes. The potential compromises to Planning Target Volume (PTV) coverage or Organ at Risk (OAR) sparing has prompted the use of adaptive radiotherapy (ART) for these patients. However, implementation of ART is time and resource intensive. This study seeks to define a clinical trigger for H&N re-plans based on spinal cord safety using kV Cone-Beam Computed Tomography (CBCT) verification imaging, in order to best balance clinical benefit with additional workload. METHODS Thirty-one H&N patients treated with Volumetric Modulated Arc Therapy (VMAT) who had a rescan CT (rCT) during treatment were included in this study. Contour volume changes between the planning CT (pCT) and rCT were determined. The original treatment plan was calculated on the pCT, CBCT prior to the rCT, pCT deformed to the anatomy of the CBCT (dCT), and rCT (considered the gold standard). The dose to 0.1 cc (D0.1cc) spinal cord was evaluated from the Dose Volume Histograms (DVHs). RESULTS The median dose increase to D0.1cc between the pCT and rCT was 0.7 Gy (inter-quartile range 0.2-1.9 Gy, p < 0.05). No correlation was found between contour volume changes and the spinal cord dose increase. Three patients exhibited an increase of 7.0-7.2 Gy to D0.1cc, resulting in a re-plan; these patients were correctly identified using calculations on the CBCT/dCT. CONCLUSIONS An adaptive re-plan can be triggered using spinal cord doses calculated on the CBCT/dCT. Implementing this trigger can reduce patient appointments and radiation dose by eliminating up to 90% of additional un-necessary CT scans, reducing the workload for radiographers, physicists, dosimetrists, and clinicians.
Collapse
Affiliation(s)
- Louise Belshaw
- Radiotherapy Physics, Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, Northern Ireland
| | - Christina E Agnew
- Radiotherapy Physics, Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, Northern Ireland
| | - Denise M Irvine
- Radiotherapy Physics, Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, Northern Ireland
| | - Keith P Rooney
- Clinical Oncology, Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, Northern Ireland
| | - Conor K McGarry
- Radiotherapy Physics, Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, Northern Ireland. .,Centre for Cancer Research and Cell Biology, Queen's University Belfast, Belfast, Northern Ireland.
| |
Collapse
|