Lee M, Noh S, Shin JB, Kwak J, Jeong C. Evaluation of Fused Deposition Modeling Materials for 3D-Printed Container of Dosimetric Polymer Gel. Gels 2024; 10:146. [PMID: 38391476 PMCID: PMC10888196 DOI: 10.3390/gels10020146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/01/2024] [Accepted: 02/07/2024] [Indexed: 02/24/2024] Open
Abstract
Accurate dosimetric verification is becoming increasingly important in radiotherapy. Although polymer gel dosimetry may be useful for verifying complex 3D dose distributions, it has limitations for clinical application due to its strong reactivity with oxygen and other contaminants. Therefore, it is important that the material of the gel storage container blocks reaction with external contaminants. In this study, we tested the effect of air and the chemical permeability of various polymer-based 3D printing materials that can be used as gel containers. A methacrylic acid, gelatin, and tetrakis (hydroxymethyl) phosphonium chloride gel was used. Five types of printing materials that can be applied to the fused deposition modeling (FDM)-type 3D printer were compared: acrylonitrile butadiene styrene (ABS), co-polyester (CPE), polycarbonate (PC), polylactic acid (PLA), and polypropylene (PP) (reference: glass vial). The map of R2 (1/T2) relaxation rates for each material, obtained from magnetic resonance imaging scans, was analyzed. Additionally, response histograms and dose calibration curves from the R2 map were evaluated. The R2 distribution showed that CPE had sharper boundaries than the other materials, and the profile gradient of CPE was also closest to the reference vial. Histograms and dose calibration showed that CPE provided the most homogeneous and the highest relative response of 83.5%, with 8.6% root mean square error, compared with the reference vial. These results indicate that CPE is a reasonable material for the FDM-type 3D printing gel container.
Collapse
Affiliation(s)
- Minsik Lee
- Department of Radiation Oncology, Kangwon National University Hospital, 157 Baengnyeong-ro, Chuncheon-si 24290, Republic of Korea
| | - Seonyeong Noh
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Republic of Korea
| | - Jun-Bong Shin
- Department of Radiation Oncology, Kangwon National University Hospital, 157 Baengnyeong-ro, Chuncheon-si 24290, Republic of Korea
| | - Jungwon Kwak
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Republic of Korea
| | - Chiyoung Jeong
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Republic of Korea
| |
Collapse
|
2
|
Chen XM, Xu CD, Zeng LP, Huang XT, Chen AQ, Liu L, Lin LW, Jia LC, Li H, Jiang XB. Analysis of Individualized Silicone Rubber Bolus Using Fan Beam Computed Tomography in Postmastectomy Radiotherapy: A Dosimetric Evaluation and Skin Acute Radiation Dermatitis Survey. Technol Cancer Res Treat 2024; 23:15330338241229367. [PMID: 38297814 PMCID: PMC10832424 DOI: 10.1177/15330338241229367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 11/28/2023] [Accepted: 01/03/2024] [Indexed: 02/02/2024] Open
Abstract
Objective: To investigate the dosimetric effects of using individualized silicone rubber (SR) bolus on the target area and organs at risk (OARs) during postmastectomy radiotherapy (PMRT), as well as evaluate skin acute radiation dermatitis (ARD). Methods: A retrospective study was performed on 30 patients with breast cancer. Each patient was prepared with an individualized SR bolus of 3 mm thickness. Fan-beam computed tomography (FBCT) was performed at the first and second fractions, and then once a week for a total of 5 times. Dosimetric metrics such as homogeneity index (HI), conformity index (CI), skin dose (SD), and OARs including the heart, lungs, and spinal cord were compared between the original plan and the FBCTs. The acute side effects were recorded. Results: In targets' dosimetric metrics, there were no significant differences in Dmean and V105% between planning computed tomography (CT) and actual treatments (P > .05), while the differences in D95%, V95%, HI, and CI were statistically significant (P < .05). In OARs, there were no significant differences between the Dmean, V5, and V20 of the affected lung, V5 of the heart and Dmax of the spinal cord (P > .05) except the V30 of affected lung, which was slightly lower than the planning CT (P < .05). In SD, both Dmax and Dmean in actual treatments were increased than plan A, and the difference was statistically significant (P < .05), while the skin-V20 and skin-V30 has no difference. Among the 30 patients, only one patient had no skin ARD, and 5 patients developed ARD of grade 2, while the remaining 24 patients were grade 1. Conclusion: The OR bolus showed good anastomoses and high interfraction reproducibility with the chest wall, and did not cause deformation during irradiation. It ensured accurate dose delivery of the target and OARs during the treatment, which may increase SD by over 101%. In this study, no cases of grade 3 skin ARD were observed. However, the potential of using OR bolus to reduce grade 1 and 2 skin ARD warrants further investigation with a larger sample size.
Collapse
Affiliation(s)
- Xue-mei Chen
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| | - Chen-di Xu
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| | - Li-ping Zeng
- Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, Guangdong Province, P.R. China
| | - Xiao-tong Huang
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| | - Ao-qiang Chen
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| | - Lu Liu
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| | - Liu-wen Lin
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| | - Le-cheng Jia
- Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, Guangdong Province, P.R. China
| | - Hua Li
- Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, Guangdong Province, P.R. China
| | - Xiao-bo Jiang
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China
| |
Collapse
|
3
|
Yu S, Ahn SH, Choi SH, Ahn WS, Jung IH. Clinical Application of a Customized 3D-Printed Bolus in Radiation Therapy for Distal Extremities. Life (Basel) 2023; 13:life13020362. [PMID: 36836718 PMCID: PMC9962406 DOI: 10.3390/life13020362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 01/19/2023] [Accepted: 01/19/2023] [Indexed: 01/31/2023] Open
Abstract
In radiation therapy (RT) for skin cancer, tissue-equivalent substances called boluses are widely used to ensure the delivery of an adequate dose to the skin surface and to provide a radioprotective effect for normal tissue. The aim of this study was to develop a new type of three-dimensional (3D) bolus for RT involving body parts with irregular geometries and to evaluate its clinical feasibility. Two 3D-printed boluses were designed for two patients with squamous cell carcinoma (SCC) of their distal extremities based on computed tomography (CT) images and printed with polylactic acid (PLA). The clinical feasibility of the boluses was evaluated by measuring the in vivo skin dose at the tumor site with optically stimulated luminescence detectors (OSLDs) and comparing the results with the prescribed and calculated doses from the Eclipse treatment planning system (TPS). The average measured dose distribution for the two patients was 94.75% of the prescribed dose and 98.8% of the calculated dose. In addition, the average measured dose during repeated treatments was 189.5 ± 3.7 cGy, thus demonstrating the excellent reproducibility of the proposed approach. Overall, the customized 3D-printed boluses for the RT of distal extremities accurately delivered doses to skin tumors with improved reproducibility.
Collapse
Affiliation(s)
- Suah Yu
- Department of Radiological Science, Kangwon National University, Samcheok 25949, Republic of Korea
- Korea Institute of Radiological & Medical Sciences, Seoul 01812, Republic of Korea
| | - So Hyun Ahn
- Ewha Medical Research Institute, College of Medicine, Ewha Womans University, Seoul 07804, Republic of Korea
- Correspondence: (S.H.A.); (W.S.A.); Tel.: +82-02-6986-6305 (S.H.A.); +82-033-610-5315 (W.S.A.)
| | - Sang Hyoun Choi
- Korea Institute of Radiological & Medical Sciences, Seoul 01812, Republic of Korea
| | - Woo Sang Ahn
- Department of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung 25440, Republic of Korea
- Correspondence: (S.H.A.); (W.S.A.); Tel.: +82-02-6986-6305 (S.H.A.); +82-033-610-5315 (W.S.A.)
| | - In-hye Jung
- Department of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung 25440, Republic of Korea
| |
Collapse
|
4
|
Pollmann S, Toussaint A, Flentje M, Wegener S, Lewitzki V. Dosimetric Evaluation of Commercially Available Flat vs. Self-Produced 3D-Conformal Silicone Boluses for the Head and Neck Region. Front Oncol 2022; 12:881439. [PMID: 36033533 PMCID: PMC9399510 DOI: 10.3389/fonc.2022.881439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 06/21/2022] [Indexed: 11/25/2022] Open
Abstract
Background Boluses are routinely used in radiotherapy to modify surface doses. Nevertheless, considerable dose discrepancies may occur in some cases due to fit inaccuracy of commercially available standard flat boluses. Moreover, due to the simple geometric design of conventional boluses, also surrounding healthy skin areas may be unintentionally covered, resulting in the unwanted dose buildup. With the fused deposition modeling (FDM) technique, there is a simple and possibly cost-effective way to solve these problems in routine clinical practice. This paper presents a procedure of self-manufacturing bespoke patient-specific silicone boluses and the evaluation of buildup and fit accuracy in comparison to standard rectangular commercially available silicone boluses. Methods 3D-conformal silicone boluses were custom-built to cover the surgical scar region of 25 patients who received adjuvant radiotherapy of head and neck cancer at the University Hospital Würzburg. During a standard CT-based planning procedure, a 5-mm-thick 3D bolus contour was generated to cover the radiopaque marked surgical scar with an additional safety margin. From these digital contours, molds were 3D printed and poured with silicone. Dose measurements for both types of boluses were performed with radiochromic films (EBT3) at three points per patient—at least one aimed to be in the high-dose area (scar) and one in the lower-dose area (spared healthy skin). Surface–bolus distance, which ideally should not be present, was determined from cone-beam CT performed for positioning control. The dosimetric influence of surface–bolus distance was also determined on slab phantom for different field sizes. The trial was performed with hardware that may be routinely available in every radiotherapy department, with the exception of the 3D printer. The required number of patients was determined based on the results of preparatory measurements with the help of the statistical consultancy of the University of Würzburg. The number of measuring points represents the total number of patients. Results In the high-dose area of the scar, there was a significantly better intended dose buildup of 2.45% (95%CI 0.0014–0.0477, p = 0.038, N = 30) in favor of a 3D-conformal bolus. Median distances between the body surface and bolus differed significantly between 3D-conformal and commercially available boluses (3.5 vs. 7.9 mm, p = 0.001). The surface dose at the slab phantom did not differ between commercially available and 3D-conformal boluses. Increasing the surface–bolus distance from 5 to 10 mm decreased the surface dose by approximately 2% and 11% in the 6 × 6- and 3 × 3-cm2 fields, respectively. In comparison to the commercially available bolus, an unintended dose buildup in the healthy skin areas was reduced by 25.9% (95%CI 19.5–32.3, p < 0.01, N = 37) using the 3D-conformal bolus limited to the region surrounding the surgical scar. Conclusions Using 3D-conformal boluses allows a comparison to the commercially available boluses’ dose buildup in the covered areas. Smaller field size is prone to a larger surface–bolus distance effect. Higher conformity of 3D-conformal boluses reduces this effect. This may be especially relevant for volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) techniques with a huge number of smaller fields. High conformity of 3D-conformal boluses reduces an unintended dose buildup in healthy skin. The limiting factor in the conformity of 3D-conformal boluses in our setting was the immobilization mask, which was produced primarily for the 3D boluses. The mask itself limited tight contact of subsequently produced 3D-conformal boluses to the mask-covered body areas. In this respect, bolus adjustment before mask fabrication will be done in the future setting.
Collapse
|
5
|
Chatchumnan N, Kingkaew S, Aumnate C, Sanghangthum T. Development and dosimetric verification of 3D customized bolus in head and neck radiotherapy. JOURNAL OF RADIATION RESEARCH 2022; 63:428-434. [PMID: 35420693 PMCID: PMC9124618 DOI: 10.1093/jrr/rrac013] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 02/05/2022] [Indexed: 06/14/2023]
Abstract
The commercial flat bolus cannot form perfect contact with the irregular surface of the patient's skin, resulting in an air gap. The purpose of this study was to evaluate the feasibility of using a 3D customized bolus from silicone rubber. The silicone rubber boluses were studied in basic characteristics. The 3D customized bolus was fabricated at the nose, cheek and neck regions. The point dose and planar dose differences were evaluated by comparing with virtual bolus. The hardness, thickness, density, Hounsfield unit (HU) and dose attenuation of the customized bolus were quite similar to a commercial bolus. When a 3D customized bolus was placed on the RANDO phantom, it can significantly increase buildup region doses and perfectly fit against the irregular surface shape. The average point dose differences of 3D customized bolus were -1.1%, while the commercial bolus plans showed -1.7%. The average gamma results for planar dose differences comparison of 3D customized bolus were 93.9%, while the commercial bolus plans were reduced to 91.9%. Overall, A silicone rubber bolus produced the feasible dosimetric properties and could save cost compared to a commercial bolus. The 3D printed customized bolus is a good buildup material and could potentially replace and improve treatment efficiency.
Collapse
Affiliation(s)
- Nichakan Chatchumnan
- Division of Radiation Oncology, Department of Radiology, King Chulalongkorn Memorial Hospital, Bangkok 10330, Thailand
| | - Sakda Kingkaew
- Division of Radiation Oncology, Department of Radiology, King Chulalongkorn Memorial Hospital, Bangkok 10330, Thailand
| | - Chuanchom Aumnate
- Metallurgy and Materials Science Research Institute Chulalongkorn University, Bangkok 10330, Thailand
| | - Taweap Sanghangthum
- Corresponding author. Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand. E-mail address:
| |
Collapse
|
6
|
Terro K, Sharrouf L, El Cheikh J. Progress of Hematopoietic Stem Cell Transplantation and Radiotherapy in the Treatment of Extranodal NK/T Cell Lymphoma. Front Oncol 2022; 12:832428. [PMID: 35252002 PMCID: PMC8888904 DOI: 10.3389/fonc.2022.832428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 01/25/2022] [Indexed: 11/21/2022] Open
Abstract
Extranodal Natural Killer/T-cell lymphoma (ENKTL) is an extremely rare type of lymphoma which is highly lethal. It mainly affects the midline area unfolding as a necrotic granulomatous and extremely disfiguring lesion. There are two subtypes of (NKTL); the most common one is nasal which appears in the nasal cavity including the nasopharynx, oropharynx, parts of the aero digestive tract and Waldeyer’s ring. While the other rarer subtype, appears in sites like the skin, testis, gastrointestinal tract, salivary glands and muscle. ENKTL is popular for the expression of multidrug resistance-associated P-glycoprotein, which not only plays the main role at exporting many antitumor agents outside tumor cells, but also makes the disease hard to treat. It is commonly associated with Epstein-Barr virus (EBV) infection and commonly occurs in Asian populations. However, there is no single unified consensus yet as to what is the standardized treatment for ENKTL. Radiotherapy alone treatment, has been considered as a first-line therapy for localized ENKTL, which later on was found to be insufficient for improving survival rates. Thus, the combination of chemotherapy and radiotherapy has been recommended as a therapeutic modality for localized ENKTL. Several combination modalities of radiotherapy and chemotherapy have been advised in clinical practice including concurrent, sequential and sandwich chemo radiotherapy. For the best treatment outcome, only patients with localized nasal ENKTL and low risk of treatment failure are eligible for radiotherapy. Both radiotherapy and hematopoietic stem cell transplantation (HSCT) have been used as treatment modalities in ENKTL patients. Upfront HSCT was performed for ENKTL, but it was associated with a very poor prognosis even for the limited-stage disease. The evidence supporting the use of HSCT to treat ENKTL was derived from the results of a series of phase 1 and 2 trials along with retrospective studies. The end result was a unified consensus that consolidative HSCT is not necessary in patients with newly diagnosed localized ENKTL who achieved complete response after treatment with any of the modern chemo radiotherapy regimens. Hence, HSCT is solely advised for advanced and relapsed NKTL. The main debate remains over which HSCT is the most suitable for patients with newly diagnosed advanced NKTL and relapsed NKTL.
Collapse
Affiliation(s)
- Khodr Terro
- Hematology-Oncology Division, Naef K. Basile Institiute-NKBCI, American University of Beirut, Beirut, Lebanon
| | - Layal Sharrouf
- Hematology-Oncology Division, Naef K. Basile Institiute-NKBCI, American University of Beirut, Beirut, Lebanon
| | - Jean El Cheikh
- Hematology-Oncology Division, Naef K. Basile Institiute-NKBCI, American University of Beirut, Beirut, Lebanon
| |
Collapse
|
7
|
Endarko E, Aisyah S, Carina CCC, Nazara T, Sekartaji G, Nainggolan A. Evaluation of Dosimetric Properties of Handmade Bolus for Megavoltage Electron and Photon Radiation Therapy. J Biomed Phys Eng 2021; 11:735-746. [PMID: 34904070 PMCID: PMC8649160 DOI: 10.31661/jbpe.v0i0.2004-1108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 06/10/2020] [Indexed: 11/25/2022]
Abstract
Background: The use of boluses for radiation therapy is very necessary to overcome the problem of sending inhomogeneous doses in the target volume due to irregularities on the surface of the skin.
The bolus materials for radiation therapy need to be evaluated. Objective: The present study aims to evaluate some handmade boluses for megavoltage electron and photon radiation therapy. Several dosimetric properties of the synthesized boluses,
including relative electron density (RED), transmission factor, mass attenuation coefficient, percentage depth dose (PDD), and percentage surface dose (PSD) were investigated. Material and Methods: In this experimental study, we evaluated natural rubber, silicone rubber mixed either with aluminum or bismuth, paraffin wax, red plasticine, and play-doh as soft tissue equivalent.
CT-simulator, in combination with ECLIPSE software, was used to determine bolus density. Meanwhile, Linear Accelerator (Linac) Clinac iX (Varian Medical Systems, Palo Alto), solid water phantom,
and Farmer ionization chamber were used to measure and analyze of dosimetric properties. Results: The RED result analysis has proven that all synthesized boluses are equivalent to the density of soft tissue such as fat, breast, lung, and liver. The dosimetric evaluation also shows that all
synthesized boluses have a density similar to the density of water and can increase the surface dose with a value ranging from 6-20% for electron energy and 30-50% for photon energy. Conclusion: In general, all synthesized boluses have an excellent opportunity to be used as an alternative tissue substitute in the surface area of the body when using megavoltage electron and photon energy.
Collapse
Affiliation(s)
- Endarko Endarko
- PhD, Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia
| | - Siti Aisyah
- BSc, Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia
| | - Chycilia Clara Chandra Carina
- BSc, Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia
| | - Trimawarti Nazara
- BSc, Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia
| | - Gandes Sekartaji
- BSc, Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia
| | - Andreas Nainggolan
- MSc, Mochtar Riady Comprehensive Cancer Center Siloam Hospitals Semanggi, Jakarta, Indonesia
| |
Collapse
|
8
|
Sasaki A, Tanaka H, Takata T, Tamari Y, Watanabe T, Hu N, Kawabata S, Kudo Y, Mitsumoto T, Sakurai Y, Suzuki M. Development of an irradiation method for superficial tumours using a hydrogel bolus in an accelerator-based BNCT. Biomed Phys Eng Express 2021; 8. [PMID: 34823226 DOI: 10.1088/2057-1976/ac3d73] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 11/25/2021] [Indexed: 11/11/2022]
Abstract
The aim of this study is the development of an irradiation method for the treatment of superficial tumours using a hydrogel bolus to produce thermal neutrons in accelerator-based Boron Neutron Capture Therapy (BNCT).To evaluate the neutron moderating ability of a hydrogel bolus, a water phantom with a hydrogel bolus was irradiated with an epithermal neutron beam from a cyclotron-based epithermal neutron source. Phantom simulating irradiation to the plantar position was manufactured using three-dimensional printing technology to perform an irradiation test of a hydrogel bolus. Thermal neutron fluxes on the surface of a phantom were evaluated and the results were compared with the Monte Carlo-based Simulation Environment for Radiotherapy Applications (SERA) treatment planning software. It was confirmed that a hydrogel bolus had the same neutron moderating ability as water, and the calculation results from SERA aligned with the measured values within approximately 5%. Furthermore, it was confirmed that the thermal neutron flux decreased at the edge of the irradiation field. It was possible to uniformly irradiate thermal neutrons by increasing the bolus thickness at the edge of the irradiation field, thereby successfully determining uniform dose distribution. An irradiation method for superficial tumours using a hydrogel bolus in the accelerator-based BNCT was established.
Collapse
Affiliation(s)
- Akinori Sasaki
- Graduate School of Engineering, Kyoto University, Kyoutodaigaku-Katsura, Kyoto, Japan
| | - Hiroki Tanaka
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori-cho, Osaka, Japan
| | - Takushi Takata
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori-cho, Osaka, Japan
| | - Yuki Tamari
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori-cho, Osaka, Japan
| | - Tsubasa Watanabe
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori-cho, Osaka, Japan
| | - Naonori Hu
- Kansai BNCT Medical Center, Osaka Medical and Pharmaceutical University, Takatsuki, Japan
| | - Shinji Kawabata
- Department of Neurosurgery, Osaka Medical and Pharmaceutical University, Takatsuki, Japan
| | | | | | - Yoshinori Sakurai
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori-cho, Osaka, Japan
| | - Minoru Suzuki
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori-cho, Osaka, Japan
| |
Collapse
|
9
|
Lu Y, Song J, Yao X, An M, Shi Q, Huang X. 3D Printing Polymer-based Bolus Used for Radiotherapy. Int J Bioprint 2021; 7:414. [PMID: 34805595 PMCID: PMC8600301 DOI: 10.18063/ijb.v7i4.414] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 07/21/2021] [Indexed: 12/24/2022] Open
Abstract
Bolus is a kind of auxiliary device used in radiotherapy for the treatment of superficial lesions such as skin cancer. It is commonly used to increase skin dose and overcome the skin-sparing effect. Despite the availability of various commercial boluses, there is currently no bolus that can form full contact with irregular surface of patients' skin, and incomplete contact would result in air gaps. The resulting air gaps can reduce the surface radiation dose, leading to a discrepancy between the delivered dose and planned dose. To avoid this limitation, the customized bolus processed by three-dimensional (3D) printing holds tremendous potential for making radiotherapy more efficient than ever before. This review mainly summarized the recent development of polymers used for processing bolus, 3D printing technologies suitable for polymers, and customization of 3D printing bolus. An ideal material for customizing bolus should not only have the feature of 3D printability for customization, but also possess radiotherapy adjuvant performance as well as other multiple compound properties, including tissue equivalence, biocompatibility, antibacterial activity, and antiphlogosis.
Collapse
Affiliation(s)
- Ying Lu
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, China.,Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan 030032, Shanxi Province, China
| | - Jianbo Song
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan 030032, Shanxi Province, China
| | - Xiaohong Yao
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, China
| | - Meiwen An
- Institute of Applied Mechanics and Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, China
| | - Qinying Shi
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan 030032, Shanxi Province, China
| | - Xiaobo Huang
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, China
| |
Collapse
|
10
|
Lu Y, Wang F, Shi Q, Zhang J, Xiang Z, Li N, Huang X, Song J. Three-Dimensional Printing Chitosan-Based Bolus Used for Radiotherapy. ACS APPLIED BIO MATERIALS 2021; 4:7094-7102. [PMID: 35006941 DOI: 10.1021/acsabm.1c00701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A bolus is a kind of tissue equivalent material used in radiotherapy for treating superficial lesions. Despite the availability of various commercial boluses, it is hard for them to form full contact with the irregular surface of patients' skin, such as the scalp, nose, and ear, resulting in air gaps and leading to a discrepancy between the delivered dose and planned dose. To solve this problem, we provided a photocurable bioink created from chitosan (CHI) for digital light processing (DLP) three-dimensional (3D) printing the bolus in radiotherapy application. The chitosan-based bioink (CHI-MA) was obtained by a methacrylation process using methacrylic anhydride (MA). Photosensitive crosslinkers with different molecular weights were introduced into the bioink. The photocuring efficiency and mechanical properties of CHI-MA hydrogels can be well modulated by varying the crosslinkers. This CHI-MA bioink allowed us to create complex structures with reliable biocompatibility, good flexibility, and excellent structural stability. Furthermore, the nose bolus processed by 3D printing this bioink proved to be a good fit for the nose model and showed a desirable radiotherapy effect. This suggests that DLP 3D printing of the CHI-MA bioink would be a promising approach to obtain the customized bolus in the application of radiotherapy.
Collapse
Affiliation(s)
- Ying Lu
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Taiyuan 030032, Shanxi Province, China
| | - Fan Wang
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, P.R. China
| | - Qinying Shi
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Taiyuan 030032, Shanxi Province, China
| | - Jianan Zhang
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, P.R. China
| | - Zuojia Xiang
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, P.R. China
| | - Ning Li
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, P.R. China
| | - Xiaobo Huang
- Laboratory of Biomaterial Surface and Interface, School of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, Shanxi Province, P.R. China
| | - Jianbo Song
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Taiyuan 030032, Shanxi Province, China
| |
Collapse
|
11
|
Wang X, Wang X, Xiang Z, Zeng Y, Liu F, Shao B, He T, Ma J, Yu S, Liu L. The Clinical Application of 3D-Printed Boluses in Superficial Tumor Radiotherapy. Front Oncol 2021; 11:698773. [PMID: 34490095 PMCID: PMC8416990 DOI: 10.3389/fonc.2021.698773] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 06/23/2021] [Indexed: 02/05/2023] Open
Abstract
During the procedure of radiotherapy for superficial tumors, the key to treatment is to ensure that the skin surface receives an adequate radiation dose. However, due to the presence of the built-up effect of high-energy rays, equivalent tissue compensators (boluses) with appropriate thickness should be placed on the skin surface to increase the target radiation dose. Traditional boluses do not usually fit the skin perfectly. Wet gauze is variable in thickness day to day which results in air gaps between the skin and the bolus. These unwanted but avoidable air gaps lead to a decrease of the radiation dose in the target area and can have a poor effect on the outcome. Three-dimensional (3D) printing, a new rising technology named “additive manufacturing” (AM), could create physical models with specific shapes from digital information by using special materials. It has been favored in many fields because of its advantages, including less waste, low-cost, and individualized design. It is not an exception in the field of radiotherapy, personalized boluses made through 3D printing technology also make up for a number of shortcomings of the traditional commercial bolus. Therefore, an increasing number of researchers have tried to use 3D-printed boluses for clinical applications rather than commercial boluses. Here, we review the 3D-printed bolus’s material selection and production process, its clinical applications, and potential radioactive dermatitis. Finally, we discuss some of the challenges that still need to be addressed with the 3D-printed boluses.
Collapse
Affiliation(s)
- Xiran Wang
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Xuetao Wang
- Department of Radiotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Zhongzheng Xiang
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Yuanyuan Zeng
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Fang Liu
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Bianfei Shao
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Tao He
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Jiachun Ma
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Siting Yu
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| | - Lei Liu
- Department of Head and Neck Oncology, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
12
|
McCallum S, Maresse S, Fearns P. Evaluating 3D-printed Bolus Compared to Conventional Bolus Types Used in External Beam Radiation Therapy. Curr Med Imaging 2021; 17:820-831. [PMID: 33530912 DOI: 10.2174/1573405617666210202114336] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 12/05/2020] [Accepted: 12/08/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND When treating superficial tumors with external beam radiation therapy, bolus is often used. Bolus increases surface dose, reduces dose to underlying tissue, and improves dose homogeneity. INTRODUCTION The conventional bolus types used clinically in practice have some disadvantages. The use of Three-Dimensional (3D) printing has the potential to create more effective boluses. CT data is used for dosimetric calculations for these treatments and often to manufacture the customized 3D-printed bolus. PURPOSE The aim of this review is to evaluate the published studies that have compared 3D-printed bolus against conventional bolus types. METHODS AND RESULTS A systematic search of several databases and a further appraisal for relevance and eligibility resulted in the 14 articles used in this review. The 14 articles were analyzed based on their comparison of 3D-printed bolus and at least one conventional bolus type. CONCLUSION The findings of this review indicated that 3D-printed bolus has a number of advantages. Compared to conventional bolus types, 3D-printed bolus was found to have equivalent or improved dosimetric measures, positional accuracy, fit, and uniformity. 3D-printed bolus was also found to benefit workflow efficiency through both time and cost effectiveness. However, factors such as patient comfort and staff perspectives need to be further explored to support the use of 3Dprinted bolus in routine practice.
Collapse
Affiliation(s)
- Stephanie McCallum
- Medical Radiation Science, Faculty of Science and Engineering, Curtin University, Perth, Australia
| | - Sharon Maresse
- Medical Radiation Science, Faculty of Science and Engineering, Curtin University, Perth, Australia
| | - Peter Fearns
- Medical Radiation Science, Faculty of Science and Engineering, Curtin University, Perth, Australia
| |
Collapse
|
13
|
Casto Z, Liu M, Lenards N, Hunzeker A, Zoller W, Blakaj DM. Multiple case dosimetric evaluation of VMAT scalp irradiation using 3D milled bolus. Med Dosim 2021; 46:324-327. [PMID: 33992490 DOI: 10.1016/j.meddos.2021.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 03/18/2021] [Indexed: 10/21/2022]
Abstract
Adequate dose homogeneity and full prescription dose delivery to the scalp still remains a dosimetric problem during scalp irradiation due to the anatomical shape of the cranium. Confounding variables such as gravity, the irregular and convex shape of the cranium, air gaps between scalp surface and commercial bolus, and potential inconsistencies in a 3D printed bolus can negatively impact the dose delivered to the scalp surface during scalp irradiation. The purpose of this retrospective case study was to implement the use of a 3D milled rigid bolus technique combined with volumetric modulated arc therapy (VMAT) treatment planning and evaluate the dosimetric efficacy in delivering dose to the surface of the scalp. The 8-patient retrospective case study consisted of patients with a scalp lesion treated using a 3D milled bolus, VMAT, 6 megavoltage (MV) photon beams, and aligned for treatment using daily conebeam computed tomography (CT) and 6° of freedom couch positioning. Dose volume histograms (DVHs) were used to evaluate maximum dose delivered to the planning target volumes (PTVs) while the dose homogeneity index (DHI) was calculated and compared to that of an ideal value of 1. The researchers evaluated the minimum dose delivered to the individual PTVs after plan normalization. The researchers found that the 3D milled bolus coupled with volumetric modulated arc therapy increased surface dose homogeneity, while also increasing the percentage of planning target volumes receiving full prescription dose. With statistically significant results, patient specific 3D milled rigid bolus offers a viable bolus option for treatment of superficial scalp lesions when combined with volumetric modulated arc therapy treatment planning. However, a larger sample size used in a scientific research study across multiple institutions would be desirable to validate these case study findings.
Collapse
Affiliation(s)
- Zachary Casto
- Medical Dosimetry Program at the University of Wisconsin - La Crosse, WI 43113, USA.
| | - Michal Liu
- Medical Dosimetry Program at the University of Wisconsin - La Crosse, WI 43113, USA
| | - Nishele Lenards
- Medical Dosimetry Program at the University of Wisconsin - La Crosse, WI 43113, USA
| | - Ashley Hunzeker
- Medical Dosimetry Program at the University of Wisconsin - La Crosse, WI 43113, USA
| | - Wesley Zoller
- Medical Dosimetry Program at the University of Wisconsin - La Crosse, WI 43113, USA
| | - Dukagjin M Blakaj
- Medical Dosimetry Program at the University of Wisconsin - La Crosse, WI 43113, USA
| |
Collapse
|
14
|
Characterization of 3D-printed bolus produced at different printing parameters. Med Dosim 2020; 46:157-163. [PMID: 33172711 DOI: 10.1016/j.meddos.2020.10.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 09/17/2020] [Accepted: 10/20/2020] [Indexed: 11/20/2022]
Abstract
We aimed to analyze the effects of printing parameters on characterization of three-dimensional (3D) printed bolus used in external beam radiotherapy. Two sets of measurements were performed to investigate the dosimetric and physical characterization of 3D-printed bolus at different printing parameters. In the first step, boluses were produced at different infill-percentages, infill-patterns and printing directions. Two-dimensional (2D) dose measurements were performed in Elekta Versa HD linear accelerator using 6 MV photon energy. Measured 2D dose maps for both printed and reference bolus materials were compared using the 2D gamma analysis method. Additionally, patient-specific bolus was produced with defined optimum printing parameters for anthropomorphic head and neck phantom. Then, point dose measurements were performed to evaluate the feasibility of printed bolus in clinical use. In the second step, physical measurements were carried out to evaluate the printing accuracy, the mean hounsfield unit (HU) value and the weight of 3D-printed boluses. According to our measurement, infill-percentage, infill-pattern and printing direction significantly changed the dosimetric and physical properties of the 3D-printed bolus independently. Maximum gamma passing rate at 1.5 and 5 cm depths were found as 93.8% and 98.8%, respectively, for 60% infill-percentage, sunglass fill infill-pattern and horizontal printing direction. The printing accuracy of the products was within 0.4 mm. Dosimetric and physical properties of the printed bolus material changed significantly with the selected printing parameters. Therefore, it is important to note that each combination of these printing parameters that will be used in the production of patient-specific bolus should be investigated separately.
Collapse
|
15
|
Dai G, Xu X, Wu X, Lei X, Wei X, Li Z, Xiao Q, Zhong R, Bai S. Application of 3D-print silica bolus for nasal NK/T-cell lymphoma radiation therapy. JOURNAL OF RADIATION RESEARCH 2020; 61:920-928. [PMID: 32960262 PMCID: PMC7674672 DOI: 10.1093/jrr/rraa084] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 06/28/2020] [Accepted: 06/23/2020] [Indexed: 02/05/2023]
Abstract
The aim of the study was to evaluate the clinical feasibility of a 3D-print silica bolus for nasal NK/T-cell lymphoma radiation therapy. Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were designed using an anthropomorphic head phantom with a 3D-print silica bolus and other kinds of bolus used clinically, and the surface dose was measured by a metal oxide semiconductor field-effect transistor (MOSFET) dosimeter. Four nasal NK/T patients with or without 3D-print silica bolus were treated and the nose surface dose was measured using a MOSFET dosimeter during the first treatment. Plans for the anthropomorphic head phantom with 3D-print bolus have more uniform dose and higher conformity of the planning target volume (PTV) compared to other boluses; the homogeneity index (HI) and conformity index (CI) of the VMAT plan were 0.0589 and 0.7022, respectively, and the HI and CI of the IMRT plan were 0.0550 and 0.7324, respectively. The MOSFET measurement results showed that the surface dose of the phantom with 3D-print bolus was >180 cGy, and that of patients with 3D-print bolus was higher than patients without bolus. The air gap volume between the 3D-print bolus and the surface of patients was <0.3 cc. The 3D-print silica bolus fitted well on the patient’s skin, effectively reducing air gaps between bolus and patient surface. Meanwhile, the 3D-print silica bolus provided patients with higher individuation, and improved the conformity and uniformity of the PTV compared to other kinds of boluses.
Collapse
Affiliation(s)
- Guyu Dai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Xin Xu
- Department of Obstetrics and Gynecology, West China Second University Hospital, Sichuan University/Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, China
| | - Xiaohong Wu
- Department of Oncology, The affiliated Hospital of Panzhihua University, Panzhihua, China
| | - Xiaolin Lei
- Department of Oncology, The affiliated Hospital of Panzhihua University, Panzhihua, China
| | - Xing Wei
- Department of Obstetrics and Gynecology, West China Second University Hospital, Sichuan University/Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, China
| | - Zhibin Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Xiao
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Renming Zhong
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Sen Bai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
16
|
Maxwell SK, Charles PH, Cassim N, Kairn T, Crowe SB. Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods. Phys Eng Sci Med 2020; 43:601-607. [PMID: 32524442 DOI: 10.1007/s13246-020-00861-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Accepted: 03/17/2020] [Indexed: 11/30/2022]
Abstract
Bolus plays an important role in the radiation therapy of superficial lesions and the application of 3D printing to its design can improve fit and dosimetry. This study quantitatively compares the fits of boluses designed from different imaging modalities. A head phantom was imaged using three systems: a CT simulator, a 3D optical scanner, and an interchangeable lens camera. Nose boluses were designed and 3D printed from each modality. A 3D printed phantom with air gaps of known thicknesses was used to calibrate mean HU to measure air gaps of unknown thickness and assess the fit of each bolus on the head phantom. The bolus created from the optical scanner data resulted in the best fit, with a mean air gap of 0.16 mm. Smoothing of the CT bolus resulted in a more clinically suitable model, comparable to that from the optical scanner method. The bolus produced from the photogrammetry method resulted in air gaps larger than 1 mm in thickness. The use of optical scanner and photogrammetry models have many advantages over the conventional bolus-from-CT method, however workflow should be refined to ensure accuracy if implemented clinically.
Collapse
Affiliation(s)
- S K Maxwell
- Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.
| | - P H Charles
- Herston Biofabrication Institute, Brisbane, QLD, Australia.,Queensland University of Technology, Brisbane, QLD, Australia
| | - N Cassim
- Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| | - T Kairn
- Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.,Queensland University of Technology, Brisbane, QLD, Australia
| | - S B Crowe
- Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.,Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|