1
|
Peteani G, Paganelli C, Giovannelli AC, Bachtiary B, Safai S, Rogers S, Pusterla O, Riesterer O, Weber DC, Lomax AJ, Baroni G, Fattori G. Retrospective reconstruction of four-dimensional magnetic resonance from interleaved cine imaging - A comparative study with four-dimensional computed tomography in the lung. Phys Imaging Radiat Oncol 2024; 29:100529. [PMID: 38235286 PMCID: PMC10792758 DOI: 10.1016/j.phro.2023.100529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 12/19/2023] [Accepted: 12/20/2023] [Indexed: 01/19/2024] Open
Abstract
Background and purpose Imaging of respiration-induced anatomical changes is essential to ensure high accuracy in radiotherapy of lung cancer. We expanded here on methods for retrospective reconstruction of time-resolved volumetric magnetic resonance (4DMR) of the thoracic region and benchmarked the results against 4D computed tomography (4DCT). Materials and method MR data of six lung cancer patients were collected by interleaving cine-navigator images with 2D data frame images, acquired across the thorax. The data frame images have been stacked in volumes based on a similarity metric that considers the anatomical deformation of lungs, while addressing ambiguities in respiratory phase detection and interpolation of missing data. The resulting images were validated against cine-navigator images and compared to paired 4DCTs in terms of amplitude and period of motion, assessing differences in internal target volume (ITV) margin definition. Results 4DMR-based motion amplitude was on average within 1.8 mm of that measured in the corresponding 2D cine-navigator images. In our dataset, the 4DCT motion and the 4DMR median amplitude were always within 3.8 mm. The median period was generally close to CT references, although deviations up to 24 % have been observed. These changes were reflected in the ITV, which was generally larger for MRI than for 4DCT (up to 39.7 %). Conclusions The proposed algorithm for retrospective reconstruction of time-resolved volumetric MR provided quality anatomical images with high temporal resolution for motion modelling and treatment planning. The potential for imaging organ motion variability makes 4DMR a valuable complement to standard 4DCT imaging.
Collapse
Affiliation(s)
- Giulia Peteani
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Anna Chiara Giovannelli
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | - Barbara Bachtiary
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
| | - Sairos Safai
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
| | - Susanne Rogers
- Department of Radiation Oncology, Kantonsspital Aarau, 5001 Aarau, Switzerland
| | - Orso Pusterla
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, University of Basel, Basel, Switzerland
- Department of Radiation Oncology, University Hospital of Zürich, 8091 Zürich, Switzerland
| | - Oliver Riesterer
- Department of Radiation Oncology, Kantonsspital Aarau, 5001 Aarau, Switzerland
| | - Damien Charles Weber
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
- Department of Radiation Oncology, University Hospital of Zürich, 8091 Zürich, Switzerland
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Switzerland
| | - Antony John Lomax
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- Bioengineering Unit, National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Giovanni Fattori
- Center for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
2
|
Hudock MR, Pinezich MR, Mir SM, Chen J, Bacchetta M, Vunjak-Novakovic G, Kim J. Emerging Imaging Modalities for Functional Assessment of Donor Lungs Ex Vivo. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2023; 25:100432. [PMID: 36778755 PMCID: PMC9913406 DOI: 10.1016/j.cobme.2022.100432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The severe shortage of functional donor lungs that can be offered to recipients has been a major challenge in lung transplantation. Innovative ex vivo lung perfusion (EVLP) and tissue engineering methodologies are now being developed to repair damaged donor lungs that are deemed unsuitable for transplantation. To assess the efficacy of donor lung reconditioning methods intended to rehabilitate rejected donor lungs, monitoring of lung function with improved spatiotemporal resolution is needed. Recent developments in live imaging are enabling non-destructive, direct, and longitudinal modalities for assessing local tissue and whole lung functions. In this review, we describe how emerging live imaging modalities can be coupled with lung tissue engineering approaches to promote functional recovery of ex vivo donor lungs.
Collapse
Affiliation(s)
- Maria R. Hudock
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Meghan R. Pinezich
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Seyed Mohammad Mir
- Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Jiawen Chen
- Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Matthew Bacchetta
- Department of Cardiac Surgery, Vanderbilt University, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Gordana Vunjak-Novakovic
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
- Department of Medicine, Columbia University, New York, NY, USA
| | - Jinho Kim
- Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| |
Collapse
|
3
|
Wu C, Krishnamoorthy G, Yu V, Subashi E, Rimner A, Otazo R. 4D lung MRI with high-isotropic-resolution using half-spoke (UTE) and full-spoke 3D radial acquisition and temporal compressed sensing reconstruction. Phys Med Biol 2023; 68. [PMID: 36535035 DOI: 10.1088/1361-6560/acace6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 12/19/2022] [Indexed: 12/23/2022]
Abstract
Objective. To develop a respiratory motion-resolved four-dimensional (4D) magnetic resonance imaging (MRI) technique with high-isotropic-resolution (1.1 mm) using 3D radial sampling, camera-based respiratory motion sensing, and temporal compressed sensing reconstruction for lung cancer imaging.Approach. Free-breathing half- and full-spoke 3D golden-angle radial acquisitions were performed on eight healthy volunteers and eight patients with lung tumors of varying size. A back-and-forth k-space ordering between consecutive interleaves of the 3D radial acquisition was performed to minimize eddy current-related artifacts. Data were sorted into respiratory motion states using camera-based motion navigation and 4D images were reconstructed using temporal compressed sensing to reduce scan time. Normalized sharpness indices of the diaphragm, apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (CNR) of the lung tumor (patients only), liver, and aortic arch were compared between half- and full-spoke 4D MRI images to evaluate the impact of respiratory motion and image contrast on 4D MRI image quality. Respiration-induced changes in lung volumes and center of mass shifts were compared between half- and full-spoke 4D MRI measurements. In addition, the motion measurements from 4D MRI and the same-day 4D CT were presented in one of the lung tumor patients.Main results. Half-spoke 4D MRI provides better visualization of the lung parenchyma, while full-spoke 4D MRI presents sharper diaphragm images and higher aSNR and CNR in the lung tumor, liver, and aortic arch. Lung volume changes and center of mass shifts measured by half- and full-spoke 4D MRI were not statistically different. For the patient with 4D MRI and same-day 4D CT, lung volume changes and center of mass shifts were generally comparable.Significance. This work demonstrates the feasibility of a motion-resolved 4D MRI technique with high-isotropic-resolution using 3D radial acquisition, camera-based respiratory motion sensing, and temporal compressed sensing reconstruction for treatment planning and motion monitoring in radiotherapy of lung cancer.
Collapse
Affiliation(s)
- Can Wu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | | | - Victoria Yu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | - Ergys Subashi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America.,Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| |
Collapse
|
4
|
Bertelsen A, Bernchou U, Schytte T, Brink C, Mahmood F. Is what you see what you treat? The effect of respiration-induced target motion in 3D magnetic resonance images. Phys Imaging Radiat Oncol 2022; 24:167-172. [DOI: 10.1016/j.phro.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 11/11/2022] [Accepted: 11/11/2022] [Indexed: 11/17/2022] Open
|
5
|
Wong OL, Law MWK, Poon DMC, Yung RWH, Yu SK, Cheung KY, Yuan J. A pilot study of respiratory motion characterization in the abdomen using a fast volumetric 4D‐MRI for MR‐guided radiotherapy. PRECISION RADIATION ONCOLOGY 2022. [DOI: 10.1002/pro6.1153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Affiliation(s)
- Oi Lei Wong
- Research Department Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| | - Max Wai Kong Law
- Medical Physics Department Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| | - Darren Ming Chun Poon
- Comprehensive Oncology Center Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| | - Raymond Wai Hung Yung
- Research Department Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| | - Siu ki Yu
- Medical Physics Department Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| | - Kin yin Cheung
- Medical Physics Department Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| | - Jing Yuan
- Research Department Hong Kong Sanatorium & Hospital, Happy Valley Hong Kong Hong Kong SAR China
| |
Collapse
|
6
|
Cheung ALY, Zhang L, Liu C, Li T, Cheung AHY, Leung C, Leung AKC, Lam SK, Lee VHF, Cai J. Evaluation of Multisource Adaptive MRI Fusion for Gross Tumor Volume Delineation of Hepatocellular Carcinoma. Front Oncol 2022; 12:816678. [PMID: 35280780 PMCID: PMC8913492 DOI: 10.3389/fonc.2022.816678] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 01/27/2022] [Indexed: 12/22/2022] Open
Abstract
Purpose Tumor delineation plays a critical role in radiotherapy for hepatocellular carcinoma (HCC) patients. The incorporation of MRI might improve the ability to correctly identify tumor boundaries and delineation consistency. In this study, we evaluated a novel Multisource Adaptive MRI Fusion (MAMF) method in HCC patients for tumor delineation. Methods Ten patients with HCC were included in this study retrospectively. Contrast-enhanced T1-weighted MRI at portal-venous phase (T1WPP), contrast-enhanced T1-weighted MRI at 19-min delayed phase (T1WDP), T2-weighted (T2W), and diffusion-weighted MRI (DWI) were acquired on a 3T MRI scanner and imported to in-house-developed MAMF software to generate synthetic MR fusion images. The original multi-contrast MR image sets were registered to planning CT by deformable image registration (DIR) using MIM. Four observers independently delineated gross tumor volumes (GTVs) on the planning CT, four original MR image sets, and the fused MRI for all patients. Tumor contrast-to-noise ratio (CNR) and Dice similarity coefficient (DSC) of the GTVs between each observer and a reference observer were measured on the six image sets. Inter-observer and inter-patient mean, SD, and coefficient of variation (CV) of the DSC were evaluated. Results Fused MRI showed the highest tumor CNR compared to planning CT and original MR sets in the ten patients. The mean ± SD tumor CNR was 0.72 ± 0.73, 3.66 ± 2.96, 4.13 ± 3.98, 4.10 ± 3.17, 5.25 ± 2.44, and 9.82 ± 4.19 for CT, T1WPP, T2W, DWI, T1WDP, and fused MRI, respectively. Fused MRI has the minimum inter-observer and inter-patient variations as compared to original MR sets and planning CT sets. GTV delineation inter-observer mean DSC across the ten patients was 0.81 ± 0.09, 0.85 ± 0.08, 0.88 ± 0.04, 0.89 ± 0.08, 0.90 ± 0.04, and 0.95 ± 0.02 for planning CT, T1WPP, T2W, DWI, T1WDP, and fused MRI, respectively. The patient mean inter-observer CV of DSC was 3.3%, 3.2%, 1.7%, 2.6%, 1.5%, and 0.9% for planning CT, T1WPP, T2W, DWI, T1WDP, and fused MRI, respectively. Conclusion The results demonstrated that the fused MRI generated using the MAMF method can enhance tumor CNR and improve inter-observer consistency of GTV delineation in HCC as compared to planning CT and four commonly used MR image sets (T1WPP, T1WDP, T2W, and DWI). The MAMF method holds great promise in MRI applications in HCC radiotherapy treatment planning.
Collapse
Affiliation(s)
- Andy Lai-Yin Cheung
- Department of Clinical Oncology, Queen Mary Hospital, Hong Kong, Hong Kong SAR, China.,Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Lei Zhang
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States.,Medical Physics Graduate Program, Duke University, Durham, NC, United States.,Medical Physics Graduate Program, Duke Kunshan University, Kunshan, China
| | - Chenyang Liu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Anson Ho-Yin Cheung
- Radiotherapy and Oncology Centre, Hong Kong Baptist Hospital, Hong Kong, Hong Kong SAR, China
| | - Chun Leung
- Radiotherapy and Oncology Centre, Hong Kong Baptist Hospital, Hong Kong, Hong Kong SAR, China
| | | | - Sai-Kit Lam
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Victor Ho-Fun Lee
- Department of Clinical Oncology, The University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China.,Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States
| |
Collapse
|
7
|
Xiao H, Ni R, Zhi S, Li W, Liu C, Ren G, Teng X, Liu W, Wang W, Zhang Y, Wu H, Lee HFV, Cheung LYA, Chang HCC, Li T, Cai J. A Dual-supervised Deformation Estimation Model (DDEM) for constructing ultra-quality 4D-MRI based on a commercial low-quality 4D-MRI for liver cancer radiation therapy. Med Phys 2022; 49:3159-3170. [PMID: 35171511 DOI: 10.1002/mp.15542] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 01/09/2022] [Accepted: 02/09/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Most available 4D-MRI techniques are limited by insufficient image quality and long acquisition times or require specially designed sequences or hardware that are not available in the clinic. These limitations have greatly hindered the clinical implementation of 4D-MRI. PURPOSE This study aims to develop a fast ultra-quality (UQ) 4D-MRI reconstruction method using a commercially available 4D-MRI sequence and dual-supervised deformation estimation model (DDEM). METHODS Thirty-nine patients receiving radiotherapy for liver tumors were included. Each patient was scanned using a TWIST-VIBE MRI sequence to acquire 4D-MR images. They also received 3D T1-/T2-weighted MRI scans as prior images and UQ 4D-MRI at any instant was considered a deformation of them. A DDEM was developed to obtain a 4D deformable vector field (DVF) from 4D-MRI data, and the prior images were deformed using this 4D-DVF to generate UQ 4D-MR images. The registration accuracies of the DDEM, VoxelMorph (normalized cross-correlation (NCC) supervised), VoxelMorph (end-to-end point error (EPE) supervised), and the parametric total variation (pTV) algorithm were compared. Tumor motion on UQ 4D-MRI was evaluated quantitatively using region-of-interest (ROI) tracking errors, while image quality was evaluated using the contrast-to-noise ratio (CNR), lung-liver edge sharpness, and perceptual blur metric (PBM). RESULTS The registration accuracy of the DDEM was significantly better than those of VoxelMorph (NCC supervised), VoxelMorph (EPE supervised) and the pTV algorithm (all, p < 0.001), with an inference time of 69.3 ± 5.9 ms. UQ 4D-MRI yielded ROI tracking errors of 0.79 ± 0.65, 0.50 ± 0.55, and 0.51 ± 0.58 mm in the superior-inferior, anterior-posterior, and mid-lateral directions, respectively. From the original 4D-MRI to UQ 4D-MRI, the CNR increased from 7.25 ± 4.89 to 18.86 ± 15.81; the lung-liver edge full-width-at-half-maximum decreased from 8.22 ± 3.17 to 3.65 ± 1.66 mm in the in-plane direction and from 8.79 ± 2.78 to 5.04 ± 1.67 mm in the cross-plane direction, and the PBM decreased from 0.68 ± 0.07 to 0.38 ± 0.01. CONCLUSION This novel DDEM method successfully generated UQ 4D-MR images based on a commercial 4D-MRI sequence. It shows great promise for improving liver tumor motion management during radiation therapy. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Haonan Xiao
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Ruiyan Ni
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Shaohua Zhi
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Wen Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Chenyang Liu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Ge Ren
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Xinzhi Teng
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Weiwei Liu
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Beijing Cancer Hospital & Institute, Peking University Cancer Hospital & Institute, Beijing, 100000, China
| | - Weihu Wang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Beijing Cancer Hospital & Institute, Peking University Cancer Hospital & Institute, Beijing, 100000, China
| | - Yibao Zhang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Beijing Cancer Hospital & Institute, Peking University Cancer Hospital & Institute, Beijing, 100000, China
| | - Hao Wu
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Beijing Cancer Hospital & Institute, Peking University Cancer Hospital & Institute, Beijing, 100000, China
| | - Ho-Fun Victor Lee
- Department of Clinical Oncology, The University of Hong Kong, Hong Kong SAR, 999077, China
| | - Lai-Yin Andy Cheung
- Department of Clinical Oncology, Queen Mary Hospital, Hong Kong SAR, 999077, China
| | | | - Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, 999077, China
| |
Collapse
|
8
|
Zhang L, Yin FF, Li T, Teng X, Xiao H, Harris W, Ren L, Kong FMS, Ge H, Mao R, Cai J. Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients. Med Phys 2021; 48:7984-7997. [PMID: 34706072 DOI: 10.1002/mp.15314] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 07/15/2021] [Accepted: 10/06/2021] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To develop a novel multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI) technique that expands single image contrast 4D-MRI to a spectrum of native and synthetic image contrasts and to evaluate its feasibility in liver tumor patients. METHODS AND MATERIALS The MC-4D-MRI technique integrates multi-parametric MRI fusion, 4D-MRI, and deformable image registration (DIR) techniques. The fusion technique consists of native MRI as input, image pre-processing, fusion algorithm, adaptation, and fused multi-contrast MRI as output. Four-dimensional deformation vector fields (4D-DVF) were generated from an original T2/T1-w 4D-MRI by deforming end-of-inhalation (EOI) to nine other phase volumes via DIR. The 4D-DVF were applied to multi-contrast MRI to generate a spectrum of 4D-MRI in different image contrasts. The MC-4D-MRI technique was evaluated in five liver tumor patients on tumor contrast-to-noise ratio (CNR), internal target volume (ITV) contouring consistency, diaphragm motion range, and tumor motion trajectory; and in digital anthropomorphic phantoms on 4D-DIR introduced errors in tumor motion range, centroid location, extent, and volume. RESULTS MC-4D-MRI consisting of 4D-MRIs in native image contrasts (T1-w, T2-w, and T2/T1-w) and synthetic image contrasts, such as tumor-enhanced contrast (TEC) were generated in five liver tumor patients. Patient tumor CNR increased from 2.6 ± 1.8 in the T2/T1-w MRI, to -4.4 ± 2.4, 6.6 ± 3.0, and 9.6 ± 3.9 in the T1-w, T2-w, and TEC MRI, respectively. Patient ITV inter-observer mean Dice similarity coefficient (mDSC) increased from 0.65 ± 0.10 in the original T2/T1-w 4D-MRI, to 0.76 ± 0.14, 0.77 ± 0.12, and 0.86 ± 0.05 in the T1-w, T2-w, and TEC 4D-MRI, respectively. Patient diaphragm motion range absolute differences between the three new 4D-MRIs and original T2/T1-w 4D-MRI were 1.2 ± 1.3, 0.3 ± 0.7, and 0.5 ± 0.5 mm, respectively. Patient tumor displacement phase-averaged absolute differences between the three 4D-MRIs and the original 4D-MRI were 0.72 ± 0.33, 0.62 ± 0.54, and 0.74 ± 0.43 mm in the superior-inferior (SI) direction, and 0.59 ± 0.36, 0.51 ± 0.30, and 0.50 ± 0.24 mm in the anterior-posterior (AP) direction, respectively. In the digital phantoms, phase-averaged absolute tumor centroid shift caused by the 4D-DIR were at or below 0.5 mm in SI, AP, and left-right (LR) directions. CONCLUSION We developed an MC-4D-MRI technique capable of expanding single image contrast 4D-MRI along a new dimension of image contrast. Initial evaluations in liver tumor patients showed enhancements in image contrast variety, tumor contrast, and ITV contouring consistencies using MC-4D-MRI. The technique might offer new perspectives on the image contrast of MRI and 4D-MRI in MR-guided radiotherapy.
Collapse
Affiliation(s)
- Lei Zhang
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Xinzhi Teng
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Haonan Xiao
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Wendy Harris
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - Lei Ren
- Department of Radiation Oncology, University of Maryland, Baltimore, Maryland, USA
| | | | - Hong Ge
- Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Ronghu Mao
- Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Jing Cai
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.,Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
9
|
Chen Y, Gong G, Wang Y, Liu C, Su Y, Wang L, Yang B, Yin Y. Comparative Evaluation of 4-Dimensional Computed Tomography and 4-Dimensional Magnetic Resonance Imaging to Delineate the Target of Primary Liver Cancer. Technol Cancer Res Treat 2021; 20:15330338211045499. [PMID: 34617855 PMCID: PMC8504652 DOI: 10.1177/15330338211045499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Purpose: To evaluate the feasibility of 4-dimensional magnetic resonance imaging (4DMRI) in establishing the target of primary liver cancer in comparison with 4-dimensional computed tomography (4DCT). Methods and Materials: A total of 23 patients with primary liver cancer who received radiotherapy were selected, and 4DCT and T2w-4DMRI simulations were conducted to obtain 4DCT and T2w-4DMRI simulation images. The 4DCT and T2w-4DMRI data were sorted into 10 and 8 respiratory phase bins, respectively. The liver and gross tumor volumes (GTVs) were delineated in all images using programmed clinical workflows under tumor delineation guidelines. The internal organs at risk volumes (IRVs) and internal target volumes (ITVs) were the unions of all the phase livers and GTVs, respectively. Then, the artifacts, liver volume, GTV, and motion range in 4DCT and T2w-4DMRI were compared. Results: The mean GTV volume based on 4DMRI was 136.42 ± 231.27 cm3, which was 25.04 cm3 (15.5%) less than that of 4DCT (161.46 ± 280.29 cm3). The average volume of ITV determined by 4DMRI was 166.12 ± 270.43 cm3, which was 22.44 cm3 (11.9%) less than that determined by 4DCT (188.56 ± 307.57 cm3). Liver volume and IRV in 4DMRI increased by 4.0% and 6.6%, respectively, compared with 4DCT. The difference in tumor motion by T2w-4DMRI based on the centroid was greater than that of 4DCT in the L/R, A/P, and S/I directions, and the average displacement differences were 2.6, 2.8, and 6.9 mm, respectively. The severe artifacts in 4DCT were 47.8% (11/23) greater than in 4DMRI 17.4% (4/23). Conclusions: Compared with 4DCT, T2-weighted and navigator-triggered 4DMRI produces fewer artifacts and larger motion differences in hepatic intrafraction tumors, which is a feasible technique for primary liver cancer treatment planning.
Collapse
Affiliation(s)
- Yukai Chen
- East China University of Technology, Nanchang, Jiangxi, China
| | - Guanzhong Gong
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Yinxing Wang
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Chenlu Liu
- School of Nuclear Science and Technology, University of South China, Hengyang, China
| | - Ya Su
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Lizhen Wang
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Bo Yang
- East China University of Technology, Nanchang, Jiangxi, China
| | - Yong Yin
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| |
Collapse
|
10
|
Optimization of a protocol for contrast-enhanced four-dimensional computed tomography imaging of thoracic tumors using minimal contrast agent. Strahlenther Onkol 2021; 197:1021-1031. [PMID: 34476528 PMCID: PMC8547213 DOI: 10.1007/s00066-021-01836-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 08/01/2021] [Indexed: 12/04/2022]
Abstract
Purpose The accuracy of target delineation for node-positive thoracic tumors is dependent on both four-dimensional computed tomography (4D-CT) and contrast-enhanced three-dimensional (3D)-CT images; these scans enable the motion visualization of tumors and delineate the nodal areas. Combining the two techniques would be more effective; however, currently, there is no standard protocol for the contrast media injection parameters for contrast-enhanced 4D-CT (CE-4D-CT) scans because of its long scan durations and complexity. Thus, we aimed to perform quantitative and qualitative assessments of the image quality of single contrast-enhanced 4D-CT scans to simplify this process and improve the accuracy of target delineation in order to replace the standard clinical modality involved in administering radiotherapy for thoracic tumors. Methods Ninety consecutive patients with thoracic tumors were randomly and parallelly assigned to one of nine subgroups subjected to CE-4D-CT scans with the administration of contrast agent volume equal to the patient’s weight but different flow rate and scan delay time (protocol A1: flow rate of 2.0 ml/s, delay time of 15 s; A2: 2.0 ml/s, 20 s; A3: 2.0 ml/s, 25 s; B1: 2.5 ml/s, 15 s; B2: 2.5 ml/s, 20 s; B3: 2.5 ml/s, 25 s; C1: 3.0 ml/s, 15 s; C2: 3.0 ml/s, 20 s; C3: 3.0 ml/s, 25 s). The Hounsfield unit (HU) values of the thoracic aorta, pulmonary artery stem, pulmonary veins, carotid artery, and jugular vein were acquired for each protocol. Both quantitative and qualitative image analysis and delineation acceptability were assessed. Results The results revealed significant differences among the nine protocols. Enhancement of the vascular structures in mediastinal and perihilar regions was more effective with protocol A1 or A2; however, when interested in the region of superior mediastinum and supraclavicular fossa, protocol C2 or C3 is recommended. Conclusion Qualitatively acceptable enhancement on contrast-enhanced 4D-CT images of thoracic tumors can be obtained by varying the flow rate and delay time when minimal contrast agent is used.
Collapse
|
11
|
Nie X, Rimner A, Li G. Feasibility of MR-guided radiotherapy using beam-eye-view 2D-cine with tumor-volume projection. Phys Med Biol 2021; 66:045020. [PMID: 33361569 DOI: 10.1088/1361-6560/abd66a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE Current magnetic resonance imaging (MRI) guided radiotherapy (MRgRT) applies sagittal/coronal 2D-cine to monitor major tumor motions, however, the beam eye's view (BEV) with volumetric tumor projection would be the best measure for radiation beam conformality, independent of tumor through-plane motion. The goal is to assess the feasibility, accuracy, and performance of the BEV approach. METHODS Beam-specific BEV 2D-cine with volume-projected tumor contours were simulated to establish a 2D/3D tumor match against a tumor-motion library based on multi-breath time-resolved (TR) 4DMRI images. Two BEV-library-matching methods were developed: (1) fast screening with tumor center-of-mass (∆COM), in-plane area ratio, and DICE similarity, and finalizing with the highest DICE score and (2) DICE screening for top-3 candidates and finalizing with rigid registration. A 4D-XCAT digital phantom and 8 lung-cancer patients were used for assessment. For each patient, 3 sets of 40 s TR-4DMRI were acquired at 2 Hz and 6 representative BEV were created with the isocenter set at tumor COM in mid-respiration. One TR-4DMRI set (40 × 2 = 80-images) was used to simulate BEV 2D-cine and the other two (160-images) were used to create a library. The matching result was validated against the ground truth within the test set. Using a leave-one-out strategy, the success rate, accuracy, and speed of tumor matching were assessed for volume-projected tumors over 11520 time-points (=8patients•3sets•80images•6BEVs). RESULTS Volume-projected tumor contour area on the 6 BEVs varies by 60% ± 8% and [Formula: see text] (in-plane/volume-projected) varies by 82% ± 9%. The [Formula: see text] changes with tumor shape, orientation, and through-plane motion. Method-1 produces 96% matching success (ΔCOM = 0.7 ± 0.2 mm, [Formula: see text]=1.01 ± 0.02, Dice=0.92 ± 0.02) with the computational time of 15 ± 1 ms/match, while method-2 produces 94% ± 1% success (ΔCOM = 0.2 ± 0.1 mm, [Formula: see text]=1.00 ± 0.01, Dice = 0.94 ± 0.02) with 223 ± 13 ms/match. CONCLUSION This study has demonstrated the feasibility, accuracy, and benefits of BEV 2D-cine imaging with tumor-volume projection, allowing real-time tumor motion monitoring and beam conformality checking. Further clinical evaluation is necessary before MRgRT applications.
Collapse
Affiliation(s)
- Xingyu Nie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States of America
| | | | | |
Collapse
|
12
|
Vergalasova I, Cai J. A modern review of the uncertainties in volumetric imaging of respiratory-induced target motion in lung radiotherapy. Med Phys 2020; 47:e988-e1008. [PMID: 32506452 DOI: 10.1002/mp.14312] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/15/2020] [Accepted: 05/26/2020] [Indexed: 12/25/2022] Open
Abstract
Radiotherapy has become a critical component for the treatment of all stages and types of lung cancer, often times being the primary gateway to a cure. However, given that radiation can cause harmful side effects depending on how much surrounding healthy tissue is exposed, treatment of the lung can be particularly challenging due to the presence of moving targets. Careful implementation of every step in the radiotherapy process is absolutely integral for attaining optimal clinical outcomes. With the advent and now widespread use of stereotactic body radiation therapy (SBRT), where extremely large doses are delivered, accurate, and precise dose targeting is especially vital to achieve an optimal risk to benefit ratio. This has largely become possible due to the rapid development of image-guided technology. Although imaging is critical to the success of radiotherapy, it can often be plagued with uncertainties due to respiratory-induced target motion. There has and continues to be an immense research effort aimed at acknowledging and addressing these uncertainties to further our abilities to more precisely target radiation treatment. Thus, the goal of this article is to provide a detailed review of the prevailing uncertainties that remain to be investigated across the different imaging modalities, as well as to highlight the more modern solutions to imaging motion and their role in addressing the current challenges.
Collapse
Affiliation(s)
- Irina Vergalasova
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, USA
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| |
Collapse
|
13
|
Sevillano D, Núñez LM, Chevalier M, García‐Vicente F. Definition of internal target volumes based on planar X-ray fluoroscopic images for lung and hepatic stereotactic body radiation therapy. Comparison to inhale/exhale CT technique. J Appl Clin Med Phys 2020; 21:56-64. [PMID: 32472618 PMCID: PMC7484833 DOI: 10.1002/acm2.12914] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 04/23/2020] [Accepted: 04/24/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To compare tumor motion amplitudes measured with 2D fluoroscopic images (FI) and with an inhale/exhale CT (IECT) technique MATERIALS AND METHODS: Tumor motion of 52 patients (39 lung patients and 13 liver patients) was obtained with both FI and IECT. For FI, tumor detection and tracking was performed by means of a software developed by the authors. Motion amplitude and, thus, internal target volume (ITV), were defined to cover the positions where the tumor spends 95% of the time. The algorithm was validated against two different respiratory motion phantoms. Motion amplitude in IECT was defined as the difference in the position of the centroid of the gross tumor volume in the image sets of both treatments. RESULTS Important differences exist when defining ITVs with FI and IECT. Overall, differences larger than 5 mm were obtained for 49%, 31%, and 9.6% of the patients in Superior-Inferior (SI), Anterior-Posterior (AP), and Lateral (LAT) directions, respectively. For tumor location, larger differences were found for tumors in the liver (73.6% SI, 27.3% AP, and 6.7% in LAT had differences larger than 5 mm), while tumors in the upper lobe benefitted less using FI (differences larger than 5 mm were only present in 27.6% (SI), 36.7% (AP), and 0% (LAT) of the patients). CONCLUSIONS Use of FI with the linac built-in CBCT system is feasible for ITV definition. Large differences between motion amplitudes detected with FI and IECT methods were found. The method presented in this work based on FI could represent an improvement in ITV definition compared to the method based on IECT due to FI permits tumor motion acquisition in a more realistic situation than IECT.
Collapse
Affiliation(s)
- David Sevillano
- Department of Medical PhysicsHospital Universitario Ramón y CajalMadridSpain
| | - Luis Miguel Núñez
- Biomedical EngineeringETSITUniversidad Politécnica de MadridMadridSpain
| | - Margarita Chevalier
- Department of Radiology, Rehabilitation and PhysiotherapyUniversidad Complutense de MadridMadridSpain
| | | |
Collapse
|
14
|
Nardone V, Giugliano FM, Reginelli A, Sangiovanni A, Mormile M, Iadanza L, Cappabianca S, Guida C. 4D CT analysis of organs at risk (OARs) in stereotactic radiotherapy. Radiother Oncol 2020; 151:10-14. [PMID: 32622777 DOI: 10.1016/j.radonc.2020.06.048] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 06/25/2020] [Accepted: 06/26/2020] [Indexed: 12/25/2022]
Abstract
Internal organs at risk volumes (IRV) represent the propagation of organs at risk (OARs) in 4DCT. Sixty consecutive patients that underwent 4DCT for thoracic stereotactic radiotherapy were analyzed and IRVs for heart, trachea, esophagus, bronchial tree, great vessels, and spinal cord were calculated. IRVs were then tested for the respect of dose constraints. IRVs were significantly bigger than standard OARs (p-value <0.001 for all the IRVs). IRVs that did not respect the dose constraints were, respectively, 7/60 (11.7%) for Heart IRV, 6/60 (10%) for Esophagus IRV, 11/60 (18.3%) for Trachea IRV, 16/60 (26.6%) for Bronchial Tree and 0/60 (0%) for great vessel and spinal cord IRV. In the subset of central targets, the percentage of plans that can be unacceptable taking into consideration OARs motion reaches 42%. The correlation of IRVs with clinical parameters and toxicity deserves future investigations in prospective trials.
Collapse
Affiliation(s)
- Valerio Nardone
- Unit of Radiation Oncology, Ospedale del Mare, Naples, Italy.
| | | | - Alfonso Reginelli
- Department of Precision Medicine, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Angelo Sangiovanni
- Department of Precision Medicine, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Maria Mormile
- Unit of Radiation Oncology, Ospedale del Mare, Naples, Italy
| | - Luciano Iadanza
- Unit of Radiation Oncology, Rummo General Hospital, Benevento, Italy
| | - Salvatore Cappabianca
- Department of Precision Medicine, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Cesare Guida
- Unit of Radiation Oncology, Ospedale del Mare, Naples, Italy
| |
Collapse
|
15
|
Nie X, Saleh Z, Kadbi M, Zakian K, Deasy J, Rimner A, Li G. A super-resolution framework for the reconstruction of T2-weighted (T2w) time-resolved (TR) 4DMRI using T1w TR-4DMRI as the guidance. Med Phys 2020; 47:3091-3102. [PMID: 32166757 DOI: 10.1002/mp.14136] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 01/30/2020] [Accepted: 03/05/2020] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The purpose of this study was to develop T2-weighted (T2w) time-resolved (TR) four-dimensional magnetic resonance imaging (4DMRI) reconstruction technique with higher soft-tissue contrast for multiple breathing cycle motion assessment by building a super-resolution (SR) framework using the T1w TR-4DMRI reconstruction as guidance. METHODS The multi-breath T1w TR-4DMRI was reconstructed by deforming a high-resolution (HR: 2 × 2 × 2 mm3 ) volumetric breath-hold (BH, 20s) three-dimensional magnetic resonance imaging (3DMRI) image to a series of low-resolution (LR: 5 × 5 × 5 mm3 ) 3D cine images at a 2Hz frame rate in free-breathing (FB, 40 s) using an enhanced Demons algorithm, namely [T1BH →FB] reconstruction. Within the same imaging session, respiratory-correlated (RC) T2w 4DMRI (2 × 2 × 2 mm3 ) was acquired based on an internal navigator to gain HR T2w (T2HR ) in three states (full exhalation and mid and full inhalation) in ~5 min. Minor binning artifacts in the RC-4DMRI were automatically identified based on voxel intensity correlation (VIC) between consecutive slices as outliers (VIC < VICmean -σ) and corrected by deforming the artifact slices to interpolated slices from the adjacent slices iteratively until no outliers were identified. A T2HR image with minimal deformation (<1 cm at the diaphragm) from the T1BH image was selected for multi-modal B-Spline deformable image registration (DIR) to establish the T2HR -T1BH voxel correspondence. Two approaches to reconstruct T2w TR-4DMRI were investigated: (A) T2HR →[T1BH →FB]: to deform T2w HR to T1w BH only as T1w TR-4DMRI was reconstructed, and combine the two displacement vector fields (DVFs) to reconstruct T2w TR-4DMRI, and (B) [T2HR ←T1BH ]→FB: to deform T1w BH to T2w HR first and apply the deformed T1w BH to reconstruct T2w TR-4DMRI. The reconstruction times were similar, 8-12 min per volume. To validate the two methods, T2w- and T1w-mapped 4D XCAT digital phantoms were utilized with three synthetic spherical tumors (ϕ = 2.0, 3.0, and 4.0 cm) in the lower or mid lobes as the ground truth to evaluate the tumor location (the center of mass, COM), size (volume ratio, %V), and shape (Dice index). Six lung cancer patients were scanned under an IRB-approved protocol and the T2w TR-4DMRI images reconstructed from the two methods were compared based on the preservation of the three tumor characteristics. The local tumor-contained image quality was also characterized using the VIC and structure similarity (SSIM) indexes. RESULTS In the 4D digital phantom, excellent tumor alignment after T2HR -T1HR DIR is achieved: ∆COM = 0.8 ± 0.5 mm, %V = 1.06 ± 0.02, and Dice = 0.91 ± 0.03, in both deformation directions using the DIR-target image as the reference. In patients, binning artifacts are corrected with improved image quality: average VIC increases from 0.92 ± 0.03 to 0.95 ± 0.01. Both T2w TR-4DMRI reconstruction methods produce similar tumor alignment errors ∆COM = 2.9 ± 0.6 mm. However, method B ([T2HR ←T1BH ]→FB) produces superior results in preserving more T2w tumor features with a higher %V = 0.99 ± 0.03, Dice = 0.81 ± 0.06, VIC = 0.85 ± 0.06, and SSIM = 0.65 ± 0.10 in the T2w TR-4DMRI images. CONCLUSIONS This study has demonstrated the feasibility of T2w TR-4DMRI reconstruction with high soft-tissue contrast and adequately-preserved tumor position, size, and shape in multiple breathing cycles. The T2w-centric DIR (method B) produces a superior solution for the SR-based framework of T2w TR-4DMRI reconstruction with highly preserved tumor characteristics and local image features, which are useful for tumor delineation and motion management in radiation therapy.
Collapse
Affiliation(s)
- Xingyu Nie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Ziad Saleh
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Mo Kadbi
- Philips Healthcare, MR Therapy, Cleveland, OH, USA
| | - Kristen Zakian
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Joseph Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Guang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| |
Collapse
|
16
|
Finazzi T, Palacios MA, Haasbeek CJ, Admiraal MA, Spoelstra FO, Bruynzeel AM, Slotman BJ, Lagerwaard FJ, Senan S. Stereotactic MR-guided adaptive radiation therapy for peripheral lung tumors. Radiother Oncol 2020; 144:46-52. [DOI: 10.1016/j.radonc.2019.10.013] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 09/25/2019] [Accepted: 10/18/2019] [Indexed: 12/22/2022]
|
17
|
Li G, Liu Y, Nie X. Respiratory-Correlated (RC) vs. Time-Resolved (TR) Four-Dimensional Magnetic Resonance Imaging (4DMRI) for Radiotherapy of Thoracic and Abdominal Cancer. Front Oncol 2019; 9:1024. [PMID: 31681573 PMCID: PMC6798178 DOI: 10.3389/fonc.2019.01024] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 09/23/2019] [Indexed: 12/25/2022] Open
Abstract
Recent technological and clinical advancements of both respiratory-correlated (RC) and time-resolved (TR) four-dimensional magnetic resonance imaging (4DMRI) techniques are reviewed in light of tumor/organ motion simulation, monitoring, and assessment in radiotherapy. For radiotherapy of thoracic and abdominal cancer, respiratory-induced tumor motion, and motion variation due to breathing irregularities are the major uncertainties in treatment. RC-4DMRI is developed to assess tumor motion for treatment planning, whereas TR-4DMRI is developed to assess both motion and motion variation for treatment planning, delivery and assessment. RC-4DMRI is reconstructed to provide one-breathing-cycle motion, similar to 4D computed tomography (4DCT), the current clinical standard, but with higher soft-tissue contrast, no ionizing radiation, and less binning artifacts due to the use of an internal respiratory surrogate. Recent studies have shown that its spatial resolution has reached or exceeded that of 4DCT and scanning time becomes clinically acceptable. TR-4DMRI is recently developed with an adequate spatiotemporal resolution to assess tumor motion and motion variations for treatment simulation, delivery and assessment. The super-resolution approach is most promising since it can image any organ/body motion, whereas RC-4D MRI are limited to resolve only respiration-induced motion and some TR-4DMRI approaches may more or less depend on RC-4DMRI. TR-4DMRI provides multi-breath motion data that are useful not only in MR-guided radiotherapy but also for building a patient-specific motion model to guide radiotherapy treatment using an non-MR-equipped linear accelerator. Based on 4DMRI motion data, motion-corrected dynamic contrast imaging and diffusion-weighted imaging have also been reported, aiming to facilitate tumor delineation for more accurate radiotherapy targeting. Both RC- and TR-4DMRI have been evaluated for potential clinical applications, such as delineation of tumor volumes, where sufficiently high spatial resolution and large field-of-view are required. The 4DMRI techniques are promising to play a role in motion assessment in radiotherapy treatment planning, delivery, assessment, and adaptation.
Collapse
Affiliation(s)
- Guang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | | | | |
Collapse
|