Zhang Y, Jiang Z, Zhang Y, Ren L. A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: Technical advances and clinical applications. Med Phys 2024. [PMID: 38922912 DOI: 10.1002/mp.17269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 03/05/2024] [Accepted: 06/01/2024] [Indexed: 06/28/2024] Open
Abstract
Cone-beam CT (CBCT) is the most commonly used onboard imaging technique for target localization in radiation therapy. Conventional 3D CBCT acquires x-ray cone-beam projections at multiple angles around the patient to reconstruct 3D images of the patient in the treatment room. However, despite its wide usage, 3D CBCT is limited in imaging disease sites affected by respiratory motions or other dynamic changes within the body, as it lacks time-resolved information. To overcome this limitation, 4D-CBCT was developed to incorporate a time dimension in the imaging to account for the patient's motion during the acquisitions. For example, respiration-correlated 4D-CBCT divides the breathing cycles into different phase bins and reconstructs 3D images for each phase bin, ultimately generating a complete set of 4D images. 4D-CBCT is valuable for localizing tumors in the thoracic and abdominal regions where the localization accuracy is affected by respiratory motions. This is especially important for hypofractionated stereotactic body radiation therapy (SBRT), which delivers much higher fractional doses in fewer fractions than conventional fractionated treatments. Nonetheless, 4D-CBCT does face certain limitations, including long scanning times, high imaging doses, and compromised image quality due to the necessity of acquiring sufficient x-ray projections for each respiratory phase. In order to address these challenges, numerous methods have been developed to achieve fast, low-dose, and high-quality 4D-CBCT. This paper aims to review the technical developments surrounding 4D-CBCT comprehensively. It will explore conventional algorithms and recent deep learning-based approaches, delving into their capabilities and limitations. Additionally, the paper will discuss the potential clinical applications of 4D-CBCT and outline a future roadmap, highlighting areas for further research and development. Through this exploration, the readers will better understand 4D-CBCT's capabilities and potential to enhance radiation therapy.
Collapse
Affiliation(s)
- Yawei Zhang
- Department of Radiation Oncology, University of Florida Health Proton Therapy Institute, Jacksonville, Florida, USA
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, USA
| | - Zhuoran Jiang
- Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA
| | - You Zhang
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Lei Ren
- Department of Radiation Oncology, University of Maryland, Baltimore, Maryland, USA
| |
Collapse
|
2
|
Nozawa Y, Ohta T, Katano A, Nawa K, Ohira S, Yamashita H, Nakagawa K. Initial validation of a diaphragm tracking system for multiple breath-hold volumetric modulated arc therapy of abdominal tumors: A phantom study. Med Phys 2024; 51:2378-2385. [PMID: 38421685 DOI: 10.1002/mp.17008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/24/2024] [Accepted: 02/14/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND The breath-hold radiotherapy has been increasingly used to mitigate interfractional and intrafractional breathing impact on treatment planning and beam delivery. Previous techniques include body surface measurements or radiopaque metal markers, each having known disadvantages. PURPOSE We recently proposed a new markerless technique without the disadvantages, where diaphragm was registered between DRR and fluoroscopic x-ray projection images every 180 ms during VMAT delivery. An initial validation of the proposed diaphragm tracking system (DiaTrak) was performed using a chest phantom to evaluate its characteristics. METHODS Diaphragm registration was performed between DRR and projection streaming kV x-ray images of a chest phantom during VMAT delivery. Streaming data including the projection images and the beam angles were transferred from a linac system to an external PC, where the diaphragm registration accuracy and beam-off latency were measured based on image cross correlation between the DRR and the projection images every 180 ms. RESULTS It was shown that the average of the beam-off latency was 249.5 ms and the average of the diaphragm registration error was 0.84 mm CONCLUSIONS: Initial validation of the proposed DiaTrak system for multiple breath-hold VMAT of abdominal tumors has been successfully completed with a chest phantom. The resulting beam-off latency and the diaphragm registration error were regarded clinically acceptable.
Collapse
Affiliation(s)
- Yuki Nozawa
- Department of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan
| | - Takeshi Ohta
- Department of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan
| | - Atsuto Katano
- Department of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan
| | - Kanabu Nawa
- Department of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan
| | - Shingo Ohira
- Department of Comprehensive Radiation Oncology, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Hideomi Yamashita
- Department of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan
| | - Keiichi Nakagawa
- Department of Comprehensive Radiation Oncology, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
3
|
Zhang Y, Shao HC, Pan T, Mengke T. Dynamic cone-beam CT reconstruction using spatial and temporal implicit neural representation learning (STINR). Phys Med Biol 2023; 68:045005. [PMID: 36638543 PMCID: PMC10087494 DOI: 10.1088/1361-6560/acb30d] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 12/27/2022] [Accepted: 01/13/2023] [Indexed: 01/15/2023]
Abstract
Objective. Dynamic cone-beam CT (CBCT) imaging is highly desired in image-guided radiation therapy to provide volumetric images with high spatial and temporal resolutions to enable applications including tumor motion tracking/prediction and intra-delivery dose calculation/accumulation. However, dynamic CBCT reconstruction is a substantially challenging spatiotemporal inverse problem, due to the extremely limited projection sample available for each CBCT reconstruction (one projection for one CBCT volume).Approach. We developed a simultaneous spatial and temporal implicit neural representation (STINR) method for dynamic CBCT reconstruction. STINR mapped the unknown image and the evolution of its motion into spatial and temporal multi-layer perceptrons (MLPs), and iteratively optimized the neuron weightings of the MLPs via acquired projections to represent the dynamic CBCT series. In addition to the MLPs, we also introduced prior knowledge, in the form of principal component analysis (PCA)-based patient-specific motion models, to reduce the complexity of the temporal mapping to address the ill-conditioned dynamic CBCT reconstruction problem. We used the extended-cardiac-torso (XCAT) phantom and a patient 4D-CBCT dataset to simulate different lung motion scenarios to evaluate STINR. The scenarios contain motion variations including motion baseline shifts, motion amplitude/frequency variations, and motion non-periodicity. The XCAT scenarios also contain inter-scan anatomical variations including tumor shrinkage and tumor position change.Main results. STINR shows consistently higher image reconstruction and motion tracking accuracy than a traditional PCA-based method and a polynomial-fitting-based neural representation method. STINR tracks the lung target to an average center-of-mass error of 1-2 mm, with corresponding relative errors of reconstructed dynamic CBCTs around 10%.Significance. STINR offers a general framework allowing accurate dynamic CBCT reconstruction for image-guided radiotherapy. It is a one-shot learning method that does not rely on pre-training and is not susceptible to generalizability issues. It also allows natural super-resolution. It can be readily applied to other imaging modalities as well.
Collapse
Affiliation(s)
- You Zhang
- Advanced Imaging and Informatics in Radiation Therapy (AIRT) Laboratory, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, 75235, United States of America
| | - Hua-Chieh Shao
- Advanced Imaging and Informatics in Radiation Therapy (AIRT) Laboratory, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, 75235, United States of America
| | - Tinsu Pan
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, TX, 77030, United States of America
| | - Tielige Mengke
- Advanced Imaging and Informatics in Radiation Therapy (AIRT) Laboratory, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, 75235, United States of America
| |
Collapse
|
4
|
Cheng X, Yang D, Zhong Y, Shao Y. Real-time marker-less tumor tracking with TOF PET: in silico feasibility study. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac6d9f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 05/06/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Purpose. Although positron emission tomography (PET) can provide a functional image of static tumors for RT guidance, it’s conventionally very challenging for PET to track a moving tumor in real-time with a multiple frame/s sampling rate. In this study, we developed a novel method to enable PET based three-dimension (3D) real-time marker-less tumor tracking (RMTT) and demonstrated its feasibility with a simulation study. Methods. For each line-of-response (LOR) acquired, its positron-electron annihilation position is calculated based on the time difference between the two gamma interactions detected by the TOF PET detectors. The accumulation of these annihilation positions from data acquired within a single sampling frame forms a coarsely measured 3D distribution of positron-emitter radiotracer uptakes of the lung tumor and other organs and tissues (background). With clinically relevant tumor size and sufficient differential radiotracer uptake concentrations between the tumor and background, the high-uptake tumor can be differentiated from the surrounding low-uptake background in the measured distribution of radiotracer uptakes. With a volume-of-interest (VOI) that closely encloses the tumor, the count-weighted centroid of the annihilation positions within the VOI can be calculated as the tumor position. All these data processes can be conducted online. The feasibility of the new method was investigated with a simulated cardiac-torso digital phantom and stationary dual-panel TOF PET detectors to track a 28 mm diameter lung tumor with a 4:1 tumor-to-background 18FDG activity concentration ratio. Results. The initial study shows TOF PET based RMTT can achieve <2.0 mm tumor tracking accuracy with 5 frame s−1 sampling rate under the simulated conditions. In comparison, using reconstructed PET images to track a similar size tumor would require >30 s acquisition time to achieve the same tracking accuracy. Conclusion. With the demonstrated feasibility, the new method may enable TOF PET based RMTT for practical RT applications.
Collapse
|
5
|
Hu P, Li X, Liu W, Yan B, Xue X, Yang F, Ford JC, Portelance L, Yang Y. Dosimetry impact of gating latency in cine magnetic resonance image guided breath-hold pancreatic cancer radiotherapy. Phys Med Biol 2022; 67. [PMID: 35144247 DOI: 10.1088/1361-6560/ac53e0] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 02/10/2022] [Indexed: 12/31/2022]
Abstract
Objective.We investigated dosimetry effect of gating latency in cine magnetic resonance image (cine MRI) guided breath-hold pancreatic cancer radiotherapy.Approach.The gating latency was calculated based on cine MRI obtained from 17 patients who received MRI guided radiotherapy. Because of the cine MRI-related latency, beam overshoot occurs when beam remains on while the tracking target already moves out of the target boundary. The number of beam on/off events was calculated from the cine MRI data. We generated both IMRT and VMAT plans for all 17 patients using 33 Gy prescription, and created motion plans by applying isocenter shift that corresponds to motion-induced tumor displacement. The GTV and PTV coverage and dose to nearby critical structures were compared between the motion and original plan to evaluate the dosimetry change caused by cine MRI latency.Main results.The time ratio of cine MRI imaging latency over the treatment duration is 6.6 ± 3.1%, the mean and median percentage of beam-on events <4 s are 67.0 ± 14.3% and 66.6%. When a gating boundary of 4 mm and a target-out threshold of 5% is used, there is no significant difference for GTV V33Gy between the motion and original plan (p = 0.861 and 0.397 for IMRT and VMAT planning techniques, respectively). However, the PTV V33Gy and stomach Dmax for the motion plans are significantly lower; duodenum V12.5 Gy and V18Gy are significantly higher when compared with the original plans, for both IMRT and VMAT planning techniques.Significance.The cine MRI gating latency can significantly decrease the dose delivered to the PTV, and increase the dose to the nearby critical structures. However, no significant difference is observed for the GTV coverage. The dosimetry impact can be mitigated by implementing additional beam-on control techniques which reduces unnecessary beam on events and/or by using faster cine MRI sequences which reduces the latency period.
Collapse
Affiliation(s)
- Panpan Hu
- Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Hefei, People's Republic of China.,Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, People's Republic of China
| | - Xiaoyang Li
- Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Hefei, People's Republic of China.,Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, People's Republic of China
| | - Wei Liu
- Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, People's Republic of China
| | - Bing Yan
- Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, People's Republic of China
| | - Xudong Xue
- Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, People's Republic of China.,Department of Radiation Oncology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| | - Fei Yang
- Department of Radiation Oncology, The Miller School of Medicine, University of Miami, Miami, United States of America
| | - John Chetley Ford
- Department of Radiation Oncology, The Miller School of Medicine, University of Miami, Miami, United States of America
| | - Lorraine Portelance
- Department of Radiation Oncology, The Miller School of Medicine, University of Miami, Miami, United States of America
| | - Yidong Yang
- Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Hefei, People's Republic of China.,Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, People's Republic of China.,Department of Radiation Oncology, The Miller School of Medicine, University of Miami, Miami, United States of America
| |
Collapse
|
6
|
Dupic G, Huertas A, Nassef M, Cosset JM. Place des Linacs dans la radiothérapie stéréotaxique extra crânienne : sont-ils désormais non inférieurs au Cyberknife® ? Bull Cancer 2022; 109:338-345. [DOI: 10.1016/j.bulcan.2021.10.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 10/07/2021] [Accepted: 10/08/2021] [Indexed: 12/25/2022]
|
7
|
Baley C, Kirby N, Wagner T, Papanikolaou N, Myers P, Rasmussen K, Stathakis S, Saenz D. On the evaluation of mobile target trajectory between four-dimensional computer tomography and four-dimensional cone-beam computer tomography. J Appl Clin Med Phys 2021; 22:198-207. [PMID: 34085384 PMCID: PMC8292704 DOI: 10.1002/acm2.13310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 03/21/2021] [Accepted: 05/09/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose For mobile lung tumors, four‐dimensional computer tomography (4D CT) is often used for simulation and treatment planning. Localization accuracy remains a challenge in lung stereotactic body radiation therapy (SBRT) treatments. An attractive image guidance method to increase localization accuracy is 4D cone‐beam CT (CBCT) as it allows for visualization of tumor motion with reduced motion artifacts. However, acquisition and reconstruction of 4D CBCT differ from that of 4D CT. This study evaluates the discrepancies between the reconstructed motion of 4D CBCT and 4D CT imaging over a wide range of sine target motion parameters and patient waveforms. Methods A thorax motion phantom was used to examine 24 sine motions with varying amplitudes and cycle times and seven patient waveforms. Each programmed motion was imaged using 4D CT and 4D CBCT. The images were processed to auto segment the target. For sine motion, the target centroid at each phase was fitted to a sinusoidal curve to evaluate equivalence in amplitude between the two imaging modalities. The patient waveform motion was evaluated based on the average 4D data sets. Results The mean difference and root‐mean‐square‐error between the two modalities for sine motion were −0.35 ± 0.22 and 0.60 mm, respectively, with 4D CBCT slightly overestimating amplitude compared with 4D CT. The two imaging methods were determined to be significantly equivalent within ±1 mm based on two one‐sided t tests (p < 0.001). For patient‐specific motion, the mean difference was 1.5 ± 2.1 (0.8 ± 0.6 without outlier), 0.4 ± 0.3, and 0.8 ± 0.6 mm for superior/inferior (SI), anterior/posterior (AP), and left/right (LR), respectively. Conclusion In cases where 4D CT is used to image mobile tumors, 4D CBCT is an attractive localization method due to its assessment of motion with respect to 4D CT, particularly for lung SBRT treatments where accuracy is paramount.
Collapse
Affiliation(s)
- Colton Baley
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Neil Kirby
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Timothy Wagner
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Nikos Papanikolaou
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Pamela Myers
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Karl Rasmussen
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Sotirios Stathakis
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | - Daniel Saenz
- Department of Radiation Oncology, School of Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| |
Collapse
|
8
|
Kim J, Keum KC, Lee H, Hong CS, Park K, Kim JS. Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study. Radiat Oncol 2020; 15:224. [PMID: 32977808 PMCID: PMC7519557 DOI: 10.1186/s13014-020-01668-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 09/14/2020] [Indexed: 12/25/2022] Open
Abstract
Background Rotational beam delivery enables concurrent acquisition of cone-beam CT (CBCT), thereby facilitating further geometric verification of patient setup during radiation treatment. However, it is challenging to acquire CBCT during stereotactic body radiation therapy (SBRT) using flattening-filter free X-ray beams, in which a high radiation dose is delivered. This study presents quantitative evaluation results of the image quality in four-dimensional (4D) in-treatment CBCT acquired during SBRT delivery. Methods The impact of megavoltage (MV) scatter and acquisition parameters on the image quality was evaluated using Catphan 503 and XSight lung tracking phantoms. The in-treatment CBCT images of the phantoms were acquired while delivering 16 SBRT plans. The uniformity, contrast, and contrast-to-noise ratio (CNR) of the in-treatment CBCT images were calculated and compared to those of CBCT images acquired without SBRT delivery. Furthermore, the localizing accuracy of the moving target in the XSight lung phantom was evaluated for 10 respiratory phases. Results The CNR of the 3D-reconstucted Catphan CBCT images was reduced from 6.3 to 2.6 due to the effect of MV treatment scatter. Both for the Catphan and XSight phantoms, the CBCT image quality was affected by the tube current and monitor units (MUs) of the treatment plan. The lung target in the XSight tracking phantom was most visible for extreme phases; the mean CNRs of the lung target in the in-treatment CBCT images (with 40 mA tube current) across the SBRT plans were 3.2 for the end-of-exhalation phase and 3.0 for the end-of-inhalation phase. The lung target was localized with sub-millimeter accuracy for the extreme respiratory phases. Conclusions Full-arc acquisition with an increased tube current (e.g. 40 mA) is recommended to compensate for degradation in the CBCT image quality due to unflattened MV beam scatter. Acquiring in-treatment CBCT with a high-MU treatment beam is also suggested to improve the resulting CBCT image quality.
Collapse
Affiliation(s)
- Jihun Kim
- Department of Radiation Oncology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, South Korea
| | - Ki Chang Keum
- Department of Radiation Oncology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, South Korea
| | - Ho Lee
- Department of Radiation Oncology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, South Korea
| | - Chae-Seon Hong
- Department of Radiation Oncology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, South Korea
| | - Kwangwoo Park
- Department of Radiation Oncology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, South Korea
| | - Jin Sung Kim
- Department of Radiation Oncology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemoon-gu, Seoul, South Korea.
| |
Collapse
|
9
|
Vergalasova I, Cai J. A modern review of the uncertainties in volumetric imaging of respiratory-induced target motion in lung radiotherapy. Med Phys 2020; 47:e988-e1008. [PMID: 32506452 DOI: 10.1002/mp.14312] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/15/2020] [Accepted: 05/26/2020] [Indexed: 12/25/2022] Open
Abstract
Radiotherapy has become a critical component for the treatment of all stages and types of lung cancer, often times being the primary gateway to a cure. However, given that radiation can cause harmful side effects depending on how much surrounding healthy tissue is exposed, treatment of the lung can be particularly challenging due to the presence of moving targets. Careful implementation of every step in the radiotherapy process is absolutely integral for attaining optimal clinical outcomes. With the advent and now widespread use of stereotactic body radiation therapy (SBRT), where extremely large doses are delivered, accurate, and precise dose targeting is especially vital to achieve an optimal risk to benefit ratio. This has largely become possible due to the rapid development of image-guided technology. Although imaging is critical to the success of radiotherapy, it can often be plagued with uncertainties due to respiratory-induced target motion. There has and continues to be an immense research effort aimed at acknowledging and addressing these uncertainties to further our abilities to more precisely target radiation treatment. Thus, the goal of this article is to provide a detailed review of the prevailing uncertainties that remain to be investigated across the different imaging modalities, as well as to highlight the more modern solutions to imaging motion and their role in addressing the current challenges.
Collapse
Affiliation(s)
- Irina Vergalasova
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, USA
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| |
Collapse
|