1
|
Leipold V, Alerić I, Mlinarić M, Kosmina D, Stanić F, Kasabašić M, Štimac D, Kaučić H, Ursi G, Schwarz K, Nikolić I, Klapan D, Schwarz D. Optimizing Choice of Skin Surrogates for Surface-Guided Stereotactic Body Radiotherapy of Lung Lesions Using Four-Dimensional Computed Tomography. Cancers (Basel) 2024; 16:2358. [PMID: 39001420 PMCID: PMC11240798 DOI: 10.3390/cancers16132358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 06/23/2024] [Accepted: 06/25/2024] [Indexed: 07/16/2024] Open
Abstract
Image-guided radiotherapy supported by surface guidance can help to track lower lung lesions' respiratory motion while reducing a patient's exposure to ionizing radiation. However, it is not always clear how the skin's respiratory motion magnitude and its correlation with the lung lesion's respiratory motion vary between different skin regions of interest (ROI). Four-dimensional computed tomography (4DCT) images provide information on both the skin and lung respiratory motion and are routinely acquired for the purpose of treatment planning in our institution. An analysis of 4DCT images for 57 patients treated in our institution has been conducted to provide information on the respiratory motion magnitudes of nine skin ROIs of the torso, a tracking structure (TS) representing a lower lung lobe lesion, as well as the respiratory motion correlations between the nine ROIs and the TS. The effects of gender and the adipose tissue volume and distribution on these correlations and magnitudes have been analyzed. Significant differences between the ROIs in both the respiratory motion magnitudes and their correlations with the TS have been detected. An overall negative correlation between the ROI respiratory magnitudes and the adipose tissue has been detected for ROIs with rib cage support. A weak to moderate negative correlation between the adipose tissue volume and ROI-to-TS respiratory correlations has been detected for upper thorax ROIs. The respiratory magnitudes in regions without rib support tend to be larger for men than for women, but no differences in the ROI-to-TS correlation between sexes have been detected. The described findings should be considered when choosing skin surrogates for lower lung lesion motion management.
Collapse
Affiliation(s)
- Vanda Leipold
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Ivana Alerić
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Mihaela Mlinarić
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Domagoj Kosmina
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Fran Stanić
- Bitwise Solutions d.o.o., 10000 Zagreb, Croatia
| | - Mladen Kasabašić
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
| | - Damir Štimac
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
| | - Hrvoje Kaučić
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Giovanni Ursi
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Karla Schwarz
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Igor Nikolić
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
- School of Medicine, University of Mostar, 88000 Mostar, Bosnia and Herzegovina
| | - Denis Klapan
- Faculty of Dental Medicine and Health Osijek, 31000 Osijek, Croatia
| | - Dragan Schwarz
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
- Faculty of Medicine, Juraj Dobrila University of Pula, 52100 Pula, Croatia
| |
Collapse
|
2
|
Seravalli E, Kroon PS, Bolle S, Dunlea C, Harrabi SB, Laprie A, Lassen-Ramshad Y, Whitfield G, Janssens GO. Surface guided radiotherapy practice in paediatric oncology: a survey on behalf of the SIOPE Radiation Oncology Working Group. Br J Radiol 2024; 97:1044-1049. [PMID: 38445717 DOI: 10.1093/bjr/tqae049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/06/2024] [Accepted: 02/20/2024] [Indexed: 03/07/2024] Open
Abstract
INTRODUCTION Surface guided radiotherapy (SGRT) is increasingly being implemented to track patient's surface movement and position during radiation therapy. However, limited information is available on the SGRT use in paediatrics. The aim of this double survey was to map SIOPE (European Society for Paediatric Oncology)-affiliated centres using SGRT and to gain information on potential indications, observed, or expected benefits. METHODS A double online survey was distributed to 246 SIOPE-affiliated radiotherapy (RT) centres. Multiple choices, yes/no, and open answers were included. The first survey (41 questions) was active from February to March 2021. A shortened version (13 questions) was repeated in March 2023 to detect trends in SGRT use within the same community. RESULTS Respectively, 76/142 (54%) and 28/142 (20%) responding centres used and planned to use SGRT clinically, including 4/34 (12%) new centres since 2021. Among the SGRT users, 33/76 (43%) already applied this technology to paediatric treatments. The main benefits of improved patient comfort, better monitoring of intrafraction motion, and more accurate initial patient set-up expected by future users did not differ from current SGRT-users (P = .893). Among non-SGRT users, the main hurdles to implement SGRT were costs and time for installation. In paediatrics, SGRT is applied to all anatomical sites. CONCLUSION This work provides information on the practice of SGRT in paediatrics across SIOPE-affiliated RT centres which can serve as a basis for departments when considering the purchase of SGRT systems. ADVANCES IN KNOWLEDGE Since little information is available in the literature on the use of SGRT in paediatrics, the results of this double survey can serve as a basis for departments treating children when considering the purchase of an SGRT system.
Collapse
Affiliation(s)
- Enrica Seravalli
- Department of Radiation Oncology, University Medical Center Utrecht, 3508 GA, The Netherlands
| | - Petra S Kroon
- Department of Radiation Oncology, University Medical Center Utrecht, 3508 GA, The Netherlands
| | - Stephanie Bolle
- Department of Radiation Oncology, Gustave Roussy Campus, Villejuif 94 800, France
| | - Cathy Dunlea
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London NW1 2PB, United Kingdom
| | - Semi B Harrabi
- Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg 69120, Germany
| | - Anne Laprie
- Institut Claudius Regaud, Institut Universitaire du Cancer de Toulouse-Oncopole, Toulouse NeuroImaging Center, Université de Toulouse, Inserm, UPS, Toulouse 31100, France
| | - Yasmin Lassen-Ramshad
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus DK-8200, Denmark
| | - Gillian Whitfield
- The Christie NHS Foundation Trust and Division of Cancer Sciences, University of Manchester, Manchester Cancer Research Centre, Manchester Academic Health Science Centre, Manchester M20 4BX, United Kingdom
| | - Geert O Janssens
- Department of Radiation Oncology, University Medical Center Utrecht, 3508 GA, The Netherlands
- Princess Maxima Center for Pediatric Oncology, Utrecht 3582CS, The Netherlands
| |
Collapse
|
3
|
Lee KN, Huynh MA. Role of Metastasis-Directed Therapy in Genitourinary Cancers. Curr Treat Options Oncol 2024; 25:605-616. [PMID: 38573430 DOI: 10.1007/s11864-024-01199-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/14/2024] [Indexed: 04/05/2024]
Abstract
OPINION STATEMENT The treatment of oligometastatic genitourinary cancers is a rapidly advancing field with ablative radiotherapy as one of the critical treatment components. The oligometastatic disease state, which can be defined as 1-5 metastatic sites with a controlled primary, represents a distinct clinical state where comprehensive ablative local therapies may provide improved outcomes. Enhanced imaging has increased the number of patients identified with oligometastatic disease. Evidence for improved outcomes with metastasis-directed therapy (MDT) in oligometastatic genitourinary cancers is increasing, and previously published outcome data continues to mature with an increasing body of prospective data to inform the role of MDT in histology-specific settings or in the context of systemic therapy. In select patients, MDT can offer benefits beyond improved local control and allow for time off of systemic therapy, prolonged time until next therapy, or even the hope of cure. However, treatment decisions for locally ablative therapy must be balanced with consideration towards safety. There are exciting advances in technologies to target and adapt treatment in real-time which have expanded options for safer delivery and dose escalation to metastatic targets near critical organs at risk. The role of systemic therapies in conjunction with MDT and incorporation of tumor genetic information to further refine prognostication and treatment decision-making in the oligometastatic setting is actively being investigated. These developments highlight the evolving field of treatment of oligometastatic disease. Future prospective studies combining MDT with enhanced imaging and integrating MDT with evolving systemic therapies will enable the optimal selection of patients most likely to benefit from this "all-or-none" approach and reveal settings in which a combination of therapies could result in synergistic outcomes.
Collapse
Affiliation(s)
- Katie N Lee
- Harvard Radiation Oncology Program, Boston, MA, USA
- Department of Radiation Oncology, Dana-Farber/Brigham and Women's Cancer Center and Harvard Medical School, 75 Francis St., Boston, MA, 02115, USA
| | - Mai Anh Huynh
- Department of Radiation Oncology, Dana-Farber/Brigham and Women's Cancer Center and Harvard Medical School, 75 Francis St., Boston, MA, 02115, USA.
| |
Collapse
|
4
|
Guo HL, Wu WW, Huan Y, Zhang HW. SGRT-based stereotactic body radiotherapy for lung cancer setup accuracy and margin of the PTV. J Appl Clin Med Phys 2024; 25:e14195. [PMID: 37915300 DOI: 10.1002/acm2.14195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/09/2023] [Accepted: 10/18/2023] [Indexed: 11/03/2023] Open
Abstract
OBJECTIVE Surface-guided radiation therapy (SGRT, AlignRT) was used to analyze motion during stereotactic body radiotherapy (SBRT) in lung cancer patients and to explore the margin of the planning target volume (PTV). METHODS The residual errors of the AlignRT were evaluated based on grayscale cone-beam computed tomography registration results before each treatment. AlignRT log file was used to analyze the correlation between the frequency and longest duration of errors larger than 2 mm and lasting longer than 2 s and maximum error with age and treatment duration. The displacement value at the end of treatment, the average displacement value, and the 95% probability density displacement interval were defined as intrafraction errors, and PTV1, PTV2, PTV3 were calculated by Van Herk formula or Z score analysis. Organ dosimetric differences were compared after the experience-based margin was replaced with PTV3. RESULTS The interfraction residual errors were Vrt0 , 0.06 ± 0.18 cm; Lng0 , -0.03 ± 0.19 cm; Lat0 , 0.02 ± 0.15 cm; Pitch0 , 0.23 ± 0.7°; Roll0 , 0.1 ± 0.69°; Rtn0 , -0.02 ± 0.79°. The frequency, longest duration and maximum error in vertical direction were correlated with treatment duration (r = 0.404, 0.353, 0.283, p < 0.05, respectively). In the longitudinal direction, the frequency was correlated with age and treatment duration (r = 0.376, 0.283, p < 0.05, respectively), maximum error was correlated with age (r = 0.4, P < 0.05). Vertical, longitudinal, lateral margins of PTV1, PTV2, PTV3 were 2 mm, 4 mm, 2 mm; 2 mm, 2 mm, 2 mm, 3 mm, 5 mm, 3 mm, respectively. After replacing the original PTV, mean lung dose (MLD), 2-cm3 chest wall dose (CD), lung V20 decreased by 0.2 Gy, 2.1 Gy, 0.5%, respectively (p < 0.05). CONCLUSION AlignRT can be used for interfraction setup and monitoring intrafraction motion. It is more reasonable to use upper and lower limits of the 95% probability density interval as an intrafraction error.
Collapse
Affiliation(s)
- Hai-Liang Guo
- Department of Oncology, the First Affiliated Hospital of Gannan Medical University, Ganzhou, China
| | - Wei-Wei Wu
- Department of Radiotherapy, the Affiliated Cancer Hospital of Gannan Medical University, GanZhou Cancer Hospital, Ganzhou, China
| | - Yan Huan
- Department of Oncology, People's Hospital of Qianxinan Buyi and Miao Minority Autonomous Prefecture, Qian xinan, China
| | - Huai-Wen Zhang
- Department of Radiotherapy, Jiangxi Cancer Hospital, The Second Affiliated Hospital of Nanchang Medical College, NHC Key Laboratory of Personalized Diagnosis and Treatment of Nasopharyngeal Carcinoma, Nanchang, China
- Department of Oncology, The Third People's Hospital of Jingdezhen, Jingdezhen, China
| |
Collapse
|
5
|
Young K, Wright EA. Automated Test for Monthly Quality Assurance of Optical Surface Imaging Dynamic Localization Accuracy. Cureus 2024; 16:e56242. [PMID: 38618470 PMCID: PMC11016349 DOI: 10.7759/cureus.56242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/15/2024] [Indexed: 04/16/2024] Open
Abstract
The American Association of Physicists in Medicine (AAPM) recently published the report of Task Group (TG) 302, which provides recommendations on acceptance, commissioning, and ongoing routine quality assurance (QA) for surface-guided radiation therapy (SGRT) systems. One of the recommended monthly QA tests is a dynamic localization accuracy test. This work aimed to develop an automated procedure for monthly SGRT dynamic localization QA. An anthropomorphic head phantom was rigidly attached to the 6-dof couch of a TrueBeam linac. TrueBeam Developer Mode was used to take an MV image of the phantom at the starting position, then automatically drive the couch through a series of translations and rotations, taking an MV image after each translation. The Identify SGRT system monitored the motion of the phantom surface from the starting position. Translations assessed on MV images were compared to translations reported in trajectory log files and Identify log files. Rotations were compared between trajectory log files and Identify log files. Three experiments were conducted. None of the translations or rotations from any experiment exceeded the tolerance values for stereotactic ablative body radiation therapy (SABR) recommended by AAPM TG-142. Maximum deviations from the expected translation values from MV imaging, trajectory log files, and Identify log files were -0.94mm, -0.11mm, and -0.78mm, respectively. Maximum deviations from the expected rotation values from trajectory log files and Identify log files were 0.01 and -0.2 degrees, respectively. The proposed method is a simple automated way to complete monthly dynamic localization QA of SGRT systems.
Collapse
Affiliation(s)
- Kaleigh Young
- Medical Physics, University of British Columbia - Okanagan Campus, Kelowna, CAN
| | - Eric A Wright
- Medical Physics, Sunnybrook Health Sciences Centre Odette Cancer Centre, Toronto, CAN
| |
Collapse
|
6
|
Remmerts de Vries IF, Verbakel WFAR, Adema M, Slotman BJ, Dahele M. Spine Stereotactic Body Radiation Therapy Without Immobilization: Detailed Analysis of Intrafraction Motion Using High-Frequency kV Imaging During Irradiation. Int J Radiat Oncol Biol Phys 2024; 118:525-532. [PMID: 37652305 DOI: 10.1016/j.ijrobp.2023.08.054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 08/21/2023] [Accepted: 08/22/2023] [Indexed: 09/02/2023]
Abstract
PURPOSE Spine stereotactic body radiation therapy (SBRT) requires high positioning accuracy and a stable patient to maximize target coverage and reduce excessive irradiation to organs at risk. Positional verification during spine SBRT delivery helps to ensure accurate positioning for all patients. We report our experience with noninvasive 3-dimensional target position monitoring during volumetric modulated arc therapy of spine metastases in nonimmobilized patients positioned using only a thin mattress and simple arm and knee supports. METHODS AND MATERIALS Fluoroscopic planar kV images were acquired at 7 frames/s using the on-board imaging system during volumetric modulated arc therapy spine SBRT. Template matching and triangulation were used to track the target in vertical, longitudinal, and lateral directions. If the tracking trace deviated >1 mm from the planned position in ≥1 direction, treatment was manually interrupted and 6-dimensional cone beam computed tomography (CBCT)-based couch correction was performed. Tracking data were used to retrospectively analyze the target position. Positional data, agreement with CBCT, correlation between position of the couch and direction of any positional correction, and treatment times were analyzed. RESULTS In total, 175 fractions were analyzed. Delivery was interrupted 83 times in 66 fractions for a deviation >1 mm. In 97% of cases the difference between tracking data and subsequent clinical shift performed after the CBCT match was ≤0.5 mm. Lateral/longitudinal shift performed after intervention correlated with the couch roll/pitch at the start of treatment (correlation coefficient, -0.63/0.53). Mean (SD; range) time between start of first imaging and end of the last arc was 15.2 minutes (5.1; 7.6-36.3). CONCLUSIONS Spine tracking during irradiation can be used to prompt an intervention CBCT scan and repositioning so that a spine SBRT target deviates by ≤1 mm from the planned position, even in nonimmobilized patients. kV tracking and CBCT are in good agreement. The data support verification CBCT after all 6 degrees-of-freedom positional corrections in nonimmobilized spine SBRT patients.
Collapse
Affiliation(s)
- Isabel F Remmerts de Vries
- Department of Radiation Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands.
| | - Wilko F A R Verbakel
- Department of Radiation Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| | - Marrit Adema
- Department of Radiation Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| | - Ben J Slotman
- Department of Radiation Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| | - Max Dahele
- Department of Radiation Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
7
|
Schöpe M, Sahlmann J, Jaschik S, Findeisen A, Klautke G. Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy. Strahlenther Onkol 2024; 200:60-70. [PMID: 37971534 DOI: 10.1007/s00066-023-02170-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 10/11/2023] [Indexed: 11/19/2023]
Abstract
PURPOSE The objective of this work is to estimate the patient positioning accuracy of a surface-guided radiation therapy (SGRT) system using an optical surface scanner compared to an X‑ray-based imaging system (IGRT) with respect to their impact on intracranial stereotactic radiotherapy (SRT) and intracranial stereotactic radiosurgery (SRS). METHODS Patient positioning data, both acquired with SGRT and IGRT systems at the same linacs, serve as a basis for determination of positioning accuracy. A total of 35 patients with two different open face masks (578 datasets) were positioned using X‑ray stereoscopic imaging and the patient position inside the open face mask was recorded using SGRT. The measurement accuracy of the SGRT system (in a "standard" and an SRS mode with higher resolution) was evaluated using both IGRT and SGRT patient positioning datasets taking into account the measurement errors of the X‑ray system. Based on these clinically measured datasets, the positioning accuracy was estimated using Monte Carlo (MC) simulations. The relevant evaluation criterion, as standard of practice in cranial SRT, was the 95th percentile. RESULTS The interfractional measurement displacement vector of the SGRT system, σSGRT, in high resolution mode was estimated at 2.5 mm (68th percentile) and 5 mm (95th percentile). If the standard resolution was used, σSGRT increased by about 20%. The standard deviation of the axis-related σSGRT of the SGRT system ranged between 1.5 and 1.8 mm interfractionally and 0.5 and 1.0 mm intrafractionally. The magnitude of σSGRT is mainly due to the principle of patient surface scanning and not due to technical limitations or vendor-specific issues in software or hardware. Based on the resulting σSGRT, MC simulations served as a measure for the positioning accuracy for non-coplanar couch rotations. If an SGRT system is used as the only patient positioning device in non-coplanar fields, interfractional positioning errors of up to 6 mm and intrafractional errors of up to 5 mm cannot be ruled out. In contrast, MC simulations resulted in a positioning error of 1.6 mm (95th percentile) using the IGRT system. The cause of positioning errors in the SGRT system is mainly a change in the facial surface relative to a defined point in the brain. CONCLUSION In order to achieve the necessary geometric accuracy in cranial stereotactic radiotherapy, use of an X‑ray-based IGRT system, especially when treating with non-coplanar couch angles, is highly recommended.
Collapse
Affiliation(s)
- Michael Schöpe
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| | - Jacob Sahlmann
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| | - Stefan Jaschik
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany.
| | - Anne Findeisen
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| | - Gunther Klautke
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| |
Collapse
|
8
|
Oku Y, Toyota M, Saigo Y. Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system. Radiol Phys Technol 2023; 16:532-542. [PMID: 37812309 DOI: 10.1007/s12194-023-00741-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 08/29/2023] [Accepted: 09/08/2023] [Indexed: 10/10/2023]
Abstract
This study aimed to evaluate the detection accuracy of the AlignRT-InBore system in surface-guided radiation therapy using a phantom and to determine the feasibility of the system by conducting a comparative analysis with cone-beam computed tomography (CBCT) registration. The AlignRT-InBore system integrated with the ETHOS Therapy was used. A phantom and a QUASAR phantom were employed to examine the specific areas of interest relevant to clinical cases. The evaluation involved monitoring translations for approximately 30 min and assessing the position detection accuracy for static and moving objects. Fifty clinical cases were used to evaluate the position detection accuracy and its relationship with the localization accuracy of CBCT before treatment. The detection accuracy of static and moving objects was within 1.0 mm using the phantom. However, the longitudinal direction tended to be larger than the other directions. Regarding the accuracy of localization in clinical cases, a strong and statistically significant (p < 0.01) correlation was observed in each direction. A detection accuracy within 1.0 mm is possible for static and moving objects. The detection accuracy of the patient setup using the InBore optical patient positioning system was extremely high, and the patient could be detected with high precision, suggesting its usefulness.
Collapse
Affiliation(s)
- Yoshifumi Oku
- Division of Radiology, Department of Clinical Technology, Kagoshima University Hospital, 8-35-1, Sakuragaoka, Kagoshima-City, Kagoshima, 890-8520, Japan.
| | - Masahiko Toyota
- Division of Radiology, Department of Clinical Technology, Kagoshima University Hospital, 8-35-1, Sakuragaoka, Kagoshima-City, Kagoshima, 890-8520, Japan
| | - Yasumasa Saigo
- Division of Radiology, Department of Clinical Technology, Kagoshima University Hospital, 8-35-1, Sakuragaoka, Kagoshima-City, Kagoshima, 890-8520, Japan
| |
Collapse
|
9
|
Psarras M, Stasinou D, Stroubinis T, Protopapa M, Zygogianni A, Kouloulias V, Platoni K. Surface-Guided Radiotherapy: Can We Move on from the Era of Three-Point Markers to the New Era of Thousands of Points? Bioengineering (Basel) 2023; 10:1202. [PMID: 37892932 PMCID: PMC10604452 DOI: 10.3390/bioengineering10101202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/10/2023] [Accepted: 10/14/2023] [Indexed: 10/29/2023] Open
Abstract
The surface-guided radiotherapy (SGRT) technique improves patient positioning with submillimeter accuracy compared with the conventional positioning technique of lasers using three-point tattoos. SGRT provides solutions to considerations that arise from the conventional setup technique, such as variability in tattoo position and the psychological impact of the tattoos. Moreover, SGRT provides monitoring of intrafractional motion. PURPOSE This literature review covers the basics of SGRT systems and examines whether SGRT can replace the traditional positioning technique. In addition, it investigates SGRT's potential in reducing positioning times, factors affecting SGRT accuracy, the effectiveness of live monitoring, and the impact on patient dosage. MATERIALS AND METHODS This study focused on papers published from 2016 onward that compared SGRT with the traditional positioning technique and investigated factors affecting SGRT accuracy and effectiveness. RESULTS/CONCLUSIONS SGRT provides the same or better results regarding patient positioning. The implementation of SGRT can reduce overall treatment time. It is an effective technique for detecting intrafraction patient motion, improving treatment accuracy and precision, and creating a safe and comfortable environment for the patient during treatment.
Collapse
Affiliation(s)
- Michalis Psarras
- Medical Physics Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Despoina Stasinou
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Theodoros Stroubinis
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Maria Protopapa
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Anna Zygogianni
- Radiation Oncology Unit, 1st Department of Radiology, Aretaieion University Hospital, Medical School, National and Kapodistrian University of Athens, 115 28 Athens, Greece
| | - Vassilis Kouloulias
- Radiation Oncology Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
| | - Kalliopi Platoni
- Medical Physics Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| |
Collapse
|
10
|
Rudat V, Shi Y, Zhao R, Xu S, Yu W. Setup accuracy and margins for surface-guided radiotherapy (SGRT) of head, thorax, abdomen, and pelvic target volumes. Sci Rep 2023; 13:17018. [PMID: 37813917 PMCID: PMC10562432 DOI: 10.1038/s41598-023-44320-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 10/06/2023] [Indexed: 10/11/2023] Open
Abstract
The goal of the study was to evaluate the inter- and intrafractional patient setup accuracy of target volumes located in the head, thoracic, abdominal, and pelvic regions when using SGRT, by comparing it with that of laser alignment using patient skin marks, and to calculate the corresponding setup margins. A total of 2303 radiotherapy fractions of 183 patients were analyzed. All patients received daily kilovoltage cone-beam computed tomography scans (kV-CBCT) for online verification. From November 2019 until September 2020, patient setup was performed using laser alignment with patient skin marks, and since October 2020, using SGRT. The setup accuracy was measured by the six degrees of freedom (6DOF) corrections based on the kV-CBCT. The corresponding setup margins were calculated using the van Herk formula. Analysis of variance (ANOVA) was used to evaluate the impact of multiple factors on the setup accuracy. The inter-fractional patient setup accuracy was significantly better using SGRT compared to laser alignment with skin marks. The mean three-dimensional vector of the translational setup deviation of tumors located in the thorax, abdomen, and pelvis using SGRT was 3.6 mm (95% confidence interval (CI) 3.3 mm to 3.9 mm) and 4.5 mm using laser alignment with skin marks (95% CI 3.9 mm to 5.2 mm; p = 0.001). Calculation of setup margins for the combined inter- and intra-fractional setup error revealed similar setup margins using SGRT and kV-CBCT once a week compared to laser alignment with skin marks and kV-CBCT every other day. Furthermore, comparable setup margins were found for open-face thermoplastic masks with AlignRT compared to closed-face thermoplastic masks with laser alignment and mask marks. SGRT opens the possibility to reduce the number of CBCTs while maintaining sufficient setup accuracy. The advantage is a reduction of imaging dose and overall treatment time. Open-face thermoplastic masks may be used instead of closed-face thermoplastic masks to increase the patient's comfort.
Collapse
Affiliation(s)
- Volker Rudat
- Department of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China.
| | - Yanyan Shi
- Department of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China
| | - Ruping Zhao
- Department of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China
| | - Shuyin Xu
- Department of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China
| | - Wei Yu
- Department of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China
| |
Collapse
|
11
|
Zhao H, Haacke C, Sarkar V, Paxton A, Jessica Huang Y, Szegedi M, Price RG, Frances Su FC, Rassiah-Szegedi P, Salter B. Initial clinical evaluation of a novel combined biometric, radio-frequency identification, and surface imaging system. Phys Med 2023; 114:103146. [PMID: 37778208 DOI: 10.1016/j.ejmp.2023.103146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/15/2023] [Accepted: 09/21/2023] [Indexed: 10/03/2023] Open
Abstract
PURPOSE To evaluate and characterize the overall clinical functionality and workflow of the newly released Varian Identify system (version 2.3). METHODS Three technologies included in the Varian Identify system were evaluated: patient biometric authentication, treatment accessory device identification, and surface-guided radiation therapy (SGRT) function. Biometric authentication employs a palm vein reader. Treatment accessory device verification utilizes two technologies: device presence via Radio Frequency Identification (RFID) and position via optical markers. Surface-guidance was evaluated on both patient orthopedic setup at loading position and surface matching and tracking at treatment isocenter. A phantom evaluation of the consistency and accuracy for Identify SGRT function was performed, including a system consistency test, a translational shift and rotational accuracy test, a pitch and roll accuracy test, a continuous recording test, and an SGRT vs Cone-Beam CT (CBCT) agreement test. RESULTS 201 patient authentications were verified successfully with palm reader. All patient treatment devices were successfully verified for their presences and positions (indexable devices). The patient real-time orthopedic pose was successfully adjusted to match the reference surface captured at simulation. SGRT-reported shift consistency against couch readout was within (0.1 mm, 0.030). The shift accuracy was within (0.3 mm, 0.10). In continuous recording mode, the maximum variation was 0.2 ± 0.12 mm, 0.030 ± 0.020. The difference between Identify SGRT offset and CBCT was within (1 mm, 10). CONCLUSIONS This clinical evaluation confirms that Identify accurately functions for patient palm identification and patient treatment device presence and position verification. Overall SGRT consistency and accuracy was within (1 mm, 10), within the 2 mm criteria of AAPM TG302.
Collapse
Affiliation(s)
- Hui Zhao
- University of Utah, United States.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Lee J, Kim YJ, Goh Y, Yang E, Kim HU, Song SY, Kim YS. Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup. Radiat Oncol J 2023; 41:172-177. [PMID: 37793626 PMCID: PMC10556842 DOI: 10.3857/roj.2023.00521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 08/10/2023] [Accepted: 08/23/2023] [Indexed: 10/06/2023] Open
Abstract
PURPOSE Surface-guided radiation therapy is an image-guided method using optical surface imaging that has recently been adopted for patient setup and motion monitoring during treatment. We aimed to determine whether the surface guide setup is accurate and efficient compared to the skin-marking guide in prostate cancer treatment. MATERIALS AND METHODS The skin-marking setup was performed, and vertical, longitudinal, and lateral couch values (labeled as "M") were recorded. Subsequently, the surface-guided setup was conducted, and couch values (labeled as "S") were recorded. After performing cone-beam computed tomography (CBCT), the final couch values was recorded (labeled as "C"), and the shift value was calculated (labeled as "Gap (M-S)," "Gap (M-C)," "Gap (S-C)") and then compared. Additionally, the setup times for the skin marking and surface guides were also compared. RESULTS One hundred and twenty-five patients were analyzed, totaling 2,735 treatment fractions. Gap (M-S) showed minimal differences in the vertical, longitudinal, and lateral averages (-0.03 cm, 0.07 cm, and 0.06 cm, respectively). Gap (M-C) and Gap (S-C) exhibited a mean difference of 0.04 cm (p = 0.03) in the vertical direction, a mean difference of 0.35 cm (p = 0.52) in the longitudinal direction, and a mean difference of 0.11 cm (p = 0.91) in the lateral direction. There was no correlation between shift values and patient characteristics. The average setup time of the skin-marking guide was 6.72 minutes, and 7.53 minutes for the surface guide. CONCLUSION There was no statistically significant difference between the surface and skin-marking guides regarding final CBCT shift values and no correlation between translational shift values and patient characteristics. We also observed minimal difference in setup time between the two methods. Therefore, the surface guide can be considered an accurate and time-efficient alternative to skin-marking guides.
Collapse
Affiliation(s)
- Jaeha Lee
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Yeon Joo Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Youngmoon Goh
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Eunyeong Yang
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Ha Un Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Si Yeol Song
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Young Seok Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
13
|
Bellala R, Kuppusamy A, Bellala VM, Tyagi T, Manoharan S, Gangarapu G, Bellala R. Review of clinical applications and challenges with surface-guided radiation therapy. J Cancer Res Ther 2023; 19:1160-1169. [PMID: 37787279 DOI: 10.4103/jcrt.jcrt_1147_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Aim To evaluate the use of this new technique, surface-guided radiotherapy (SGRT), for patient setup and motion management in various cancers. Materials and Methods Data was collected from 533 patients, who received treatment in our hospital for various malignancies using SGRT from October 2019 to April 2021. We studied patient setup, interfraction position, and patient position during the breath-hold (BH) technique. The main advantage of SGRT is that, it is completely non-invasive and uses visible light to compare the patient's skin surface in the treatment room and planned treatment position. In this analysis, Monaco 5.51.10 (Elekta) treatment planning system, Versa HD Linear Accelerator, and AlignRT 6.2 (Vision RT) SGRT system were used. Results With SGRT, treatment setup time can be reduced with more precision and techniques like Deep inspiration breathhold (DIBH) can be done with very good compliance. Conclusion SGRT has shown improved accuracy in patient setup compared to conventional laser setup. The daily kilo voltage imaging frequency can be reduced; it helps in reducing additional radiation exposure due to imaging. SGRT has demonstrated reproducibility with adequate accuracy in BH treatments in DIBH for breast and SBRT.
Collapse
Affiliation(s)
- Ravishankar Bellala
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| | - Anandakrishnan Kuppusamy
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| | - Venkat Madhavi Bellala
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| | - Tulika Tyagi
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| | - Surendhiran Manoharan
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| | - Gunasekhar Gangarapu
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| | - Rishik Bellala
- Department of Radiation Oncology, Omega Hospital, Arilova, Health City, Chinagadili, Visakhapatnam, Andhra Pradesh, India
| |
Collapse
|
14
|
Kaestner L, Streb L, Hetjens S, Buergy D, Sihono DS, Fleckenstein J, Kalisch I, Eckl M, Giordano FA, Lohr F, Stieler F, Boda-Heggemann J. Surface guidance compared with ultrasound-based monitoring and diaphragm position in cone-beam computed tomography during abdominal stereotactic radiotherapy in breath-hold. Phys Imaging Radiat Oncol 2023; 27:100455. [PMID: 37720462 PMCID: PMC10500027 DOI: 10.1016/j.phro.2023.100455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 05/30/2023] [Accepted: 05/31/2023] [Indexed: 09/19/2023] Open
Abstract
Background and purpose Spirometry induced deep-inspiration-breath-hold (DIBH) reduces intrafractional motion during upper abdominal stereotactic body radiotherapy (SBRT). The aim of this prospective study was to evaluate whether surface scanning (SGRT) is an adequate surrogate for monitoring residual internal motion during DIBH. Residual motion detected by SGRT was compared with experimental 4D-ultrasound (US) and an internal motion detection benchmark (diaphragm-dome-position in kV cone-beam computed tomography (CBCT) projections). Materials and methods Intrafractional monitoring was performed with SGRT and US in 460 DIBHs of 12 patients. Residual motion detected by all modalities (SGRT (anterior-posterior (AP)), US (AP, craniocaudal (CC)) and CBCT (CC)) was analyzed. Agreement analysis included Wilcoxon signed rank test, Maloney and Rastogi's test, Pearson's correlation coefficient (PCC) and interclass correlation coefficient (ICC). Results Interquartile range was 0.7 mm (US(AP)), 0.8 mm (US(CC)), 0.9 mm (SGRT) and 0.8 mm (CBCT). SGRT(AP) vs. CBCT(CC) and US(CC) vs. CBCT(CC) showed comparable agreement (PCCs 0.53 and 0.52, ICCs 0.51 and 0.49) with slightly higher precision of CBCT(CC). Most agreement was observed for SGRT(AP) vs. US(AP) with largest PCC (0.61) and ICC (0.60), least agreement for SGRT(AP) vs. US(CC) with smallest PCC (0.44) and ICC (0.42). Conclusions Residual motion detected during spirometry induced DIBH is small. SGRT alone is no sufficient surrogate for residual internal motion in all patients as some high velocity motion could not be detected. Observed patient-specific residual errors may require individualized PTV-margins.
Collapse
Affiliation(s)
- Lena Kaestner
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Lara Streb
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Svetlana Hetjens
- University Medical Center Mannheim, Department of Medical Statistics and Biomathematics, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Daniel Buergy
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Dwi S.K. Sihono
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
- Departemen Fisika, FMIPA, Universitas Indonesia, Depok 16424, Indonesia
| | - Jens Fleckenstein
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Iris Kalisch
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Miriam Eckl
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Frank A. Giordano
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Frank Lohr
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
- Struttura Complessa di Radioterapia, Dipartimento di Oncologia, Az. Ospedaliero-Universitaria di Modena, Largo del Pozzo 71, 41122 Modena, Italy
| | - Florian Stieler
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Judit Boda-Heggemann
- University Medical Center Mannheim, Department of Radiation Oncology, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| |
Collapse
|
15
|
Zhang G, Jiang Z, Zhu J, Dai T, He X, Liu X, Chang Y, Wang L. Innovative integration of augmented reality and optical surface imaging: A coarse-to-precise system for radiotherapy positioning. Med Phys 2023. [PMID: 37060328 DOI: 10.1002/mp.16417] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 04/01/2023] [Accepted: 04/02/2023] [Indexed: 04/16/2023] Open
Abstract
BACKGROUND Traditional methods of radiotherapy positioning have shortcomings such as fragile skin-markers, additional doses, and lack of information integration. Emerging technologies may provide alternatives for the relevant clinical practice. PURPOSE To propose a noninvasive radiotherapy positioning system integrating augmented reality (AR) and optical surface, and to evaluate its feasibility in clinical workflow. METHODS AR and structured light-based surface were integrated to implement the coarse-to-precise positioning through two coherent steps, the AR-based coarse guidance and the optical surface-based precise verification. To implement quality assurance, recognition of face and pattern was used for patient authentication, case association, and accessory validation in AR scenes. The holographic images reconstructed from simulation computed tomography (CT) images, guided the initial posture correction by virtual-real alignment. The point clouds of body surface were fused, with the calibration and pose estimation of structured light cameras, and segmented according to the preset regions of interest (ROIs). The global-to-local registration for cross-source point clouds was achieved to calculate couch shifts in six degrees-of-freedom (DoF), which were ultimately transmitted to AR scenes. The evaluation based on phantom and human-body (4 volunteers) included, (i) quality assurance workflow, (ii) errors of both steps and correlation analysis, (iii) receiver operating characteristic (ROC), (iv) distance characteristics of accuracy, and (v) clinical positioning efficiency. RESULTS The maximum errors in phantom evaluation were 3.4 ± 2.5 mm in Vrt and 1.4 ± 1.0° in Pitch for the coarse guidance step, while 1.6 ± 0.9 mm in Vrt and 0.6 ± 0.4° in Pitch for the precise verification step. The Pearson correlation coefficients between precise verification and cone beam CT (CBCT) results were distributed in the interval [0.81, 0.85]. In ROC analysis, the areas under the curve (AUC) were 0.87 and 0.89 for translation and rotation, respectively. In human body-based evaluation, the errors of thorax and abdomen (T&A) were significantly greater than those of head and neck (H&N) in Vrt (2.6 ± 1.1 vs. 1.7 ± 0.8, p < 0.01), Lng (2.3 ± 1.1 vs. 1.4 ± 0.9, p < 0.01), and Rtn (0.8 ± 0.4 vs. 0.6 ± 0.3, p = 0.01) while relatively similar in Lat (1.8 ± 0.9 vs. 1.7 ± 0.8, p = 0.07). The translation displacement range, after coarse guidance step, required for high accuracy of the optical surface component of the integrated system was 0-42 mm, and the average positioning duration of the integrated system was significantly less than that of conventional workflow (355.7 ± 21.7 vs. 387.7 ± 26.6 s, p < 0.01). CONCLUSIONS The combination of AR and optical surface has utility and feasibility for patient positioning, in terms of both safety and accuracy.
Collapse
Affiliation(s)
- Gongsen Zhang
- Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan, Shandong, China
| | - Zejun Jiang
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan, Shandong, China
| | - Jian Zhu
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan, Shandong, China
| | - Tianyuan Dai
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan, Shandong, China
| | - Xiaolong He
- Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan, Shandong, China
| | - Xinchao Liu
- Cheeloo College of Medicine, Shandong University, Ji'nan, Shandong, China
| | - Yankui Chang
- School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, China
| | - Linlin Wang
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan, Shandong, China
| |
Collapse
|
16
|
Nguyen D, Khodri M, Sporea C, Reinoso R, Jacob Y, Farah J. Investigating the robustness of the AlignRT InBore™ co-calibration process and determining the overall tracking errors. Phys Med 2023; 108:102567. [PMID: 36996575 DOI: 10.1016/j.ejmp.2023.102567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 02/05/2023] [Accepted: 03/18/2023] [Indexed: 03/30/2023] Open
Abstract
OBJECTIVE To determine the overall tracking errors inherent to the co-calibration procedure of AlignRT InBore™'s (Vision RT Ltd., London, UK) ceiling-mounted and ring-mounted cameras. METHODS Extrinsic calibration errors related to the mismatch between ceiling and InBore cameras' isocentres and treatment isocentre were determined using MV images and the SRS package and compared to traditional plate-based error. Next, using a realistic anthropomorphic female phantom, intrinsic calibration errors were determined while varying source-skin distance (80 to 100 cm), breast board inclination (0° to 12.5°), room lighting conditions (0 to 258 lx), skin colour (dark, white and natural skin colour), and pod occlusion. RESULTS MV images of the cube proved plate-based calibration to suffer from large errors especially in the vertical direction (up to 2 mm). Intrinsic calibration errors were considerably lower. Indeed, RTD values of ceiling and InBore cameras showed little variability with isocentre depth (within 1.0 mm/0.4°), surface orientation and breast board inclination (within 0.7 mm/0.3°), changing lighting conditions (within 0.1 mm/0.2°), skin colour/tone (within 0.3 mm/0.3°) and camera pod occlusion (within 0.3 mm/0.2°). CONCLUSION The use of MV-images proved critical to maintain co-calibrating errors of ceiling and InBore cameras to Halcyon's treatment isocentre below 1 mm.
Collapse
|
17
|
Qubala A, Schwahofer A, Jersemann S, Eskandarian S, Harrabi S, Naumann P, Winter M, Ellerbrock M, Shafee J, Abtehi S, Herfarth K, Debus J, Jäkel O. Optimizing the Patient Positioning Workflow of Patients with Pelvis, Limb, and Chest/Spine Tumors at an Ion-Beam Gantry based on Optical Surface Guidance. Adv Radiat Oncol 2022; 8:101105. [PMID: 36624871 PMCID: PMC9822948 DOI: 10.1016/j.adro.2022.101105] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 10/01/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose Surface-guided radiation therapy (SGRT) has been investigated intensively to ensure correct patient positioning during a radiation therapy course. Although the implementation is well defined for photon-beam facilities, only a few analyses have been published for ion-beam therapy centers. To investigate the accuracy, reliability, and efficiency of SGRT used in ion-beam treatments against the conventional skin marks, a retrospective study of a unique SGRT installation in an ion gantry treatment room was conducted, where the environment is quite different to conventional radiation therapy. Methods and Materials There were 32 patients, divided into 3 cohorts-pelvis, limb, and chest/spine tumors-and treated with ion-beams. Two patient positioning workflows based on 300 fractions were compared: workflow with skin marks and workflow with SGRT. Position verification was followed by planar kilo voltage imaging. After image matching, 6 degrees of freedom corrections were recorded to assess interfraction positioning errors. In addition, the time required for patient positioning, image matching, and the number of repeated kilo voltage imaging also were gathered. Results SGRT decreased the translational magnitude shifts significantly (P < .05) by 0.5 ± 1.4 mm for pelvis and 1.9 ± 0.5 mm for limb, whereas for chest/spine, it increased by 0.7 ± 0.3 mm. Rotational corrections were predominantly lowered with SGRT for all cohorts with significant differences in pitch for pelvis (P = .002) and chest/spine (P = .009). The patient positioning time decreased by 18%, 9%, and 15% for pelvis, limb, and chest/spine, respectively, compared with skin marks. By using SGRT, 53% of all studied patients had faster positioning time, and 87.5% had faster matching time. Repositioning and consequent reimaging decreased from about 7% to 2% with a statistically significant difference of .042. Conclusions The quality of patient positioning before ion-beam treatments has been optimized by using SGRT without additional imaging dose. SGRT clearly reduced inefficiencies in the patient positioning workflow.
Collapse
Affiliation(s)
- Abdallah Qubala
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,Faculty of Medicine, University of Heidelberg, Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Corresponding author: Abdallah Qubala, MSc
| | - Andrea Schwahofer
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Stefan Jersemann
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - Saleh Eskandarian
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - Semi Harrabi
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Patrick Naumann
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Marcus Winter
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - Malte Ellerbrock
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - Jehad Shafee
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,Saarland University of Applied Sciences, Saarbruecken, Germany
| | - Samira Abtehi
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - Klaus Herfarth
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Jürgen Debus
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Oliver Jäkel
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany,Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany,National Center for Tumor Diseases (NCT), Heidelberg, Germany
| |
Collapse
|
18
|
Zhao H, Paxton A, Sarkar V, Price RG, Huang J, Su FCF, Li X, Rassiah P, Szegedi M, Salter B. Surface-Guided Patient Setup Versus Traditional Tattoo Markers for Radiation Therapy: Is Tattoo-Less Setup Feasible for Thorax, Abdomen and Pelvis Treatment? Cureus 2022; 14:e28644. [PMID: 36196310 PMCID: PMC9525098 DOI: 10.7759/cureus.28644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/27/2022] [Indexed: 11/28/2022] Open
Abstract
Purpose: In this study, patient setup accuracy was compared between surface guidance and tattoo markers for radiation therapy treatment sites of the thorax, abdomen and pelvis. Methods and materials: A total of 608 setups performed on 59 patients using both surface-guided and tattoo-based patient setups were analyzed. During treatment setup, patients were aligned to room lasers using their tattoos, and then the six-degree-of-freedom (6DOF) surface-guided offsets were calculated and recorded using AlignRT system. While the patient remained in the same post-tattoo setup position, target localization imaging (radiographic or ultrasound) was performed and these image-guided shifts were recorded. Finally, surface-guided vs tattoo-based offsets were compared to the final treatment position (based on radiographic or ultrasound imaging) to evaluate the accuracy of the two setup methods. Results: The overall average offsets of tattoo-based and surface-guidance-based patient setups were comparable within 3.2 mm in three principal directions, with offsets from tattoo-based setups being slightly less. The maximum offset for tattoo setups was 2.2 cm vs. 4.3 cm for surface-guidance setups. Larger offsets (ranging from 2.0 to 4.3 cm) were observed for surface-guided setups in 14/608 setups (2.3%). For these same cases, the maximum observed tattoo-based offset was 0.7 cm. Of the cases with larger surface-guided offsets, 13/14 were for abdominal/pelvic treatment sites. Additionally, larger rotations (>3°) were recorded in 18.6% of surface-guided setups. The majority of these larger rotations were observed for abdominal and pelvic sites (~84%). Conclusions: The small average differences observed between tattoo-based and surface-guidance-based patient setups confirm the general equivalence of the two potential methods, and the feasibility of tattoo-less patient setup. However, a significant number of larger surface-guided offsets (translational and rotational) were observed, especially in the abdominal and pelvic regions. These cases should be anticipated and contingency setup methods planned for.
Collapse
|
19
|
Sato K, Kanai T, Lee SH, Miyasaka Y, Chai H, Souda H, Iwai T, Sato R, Goto N, Kawamura T. Development of a quantitative analysis method for assessing patient body surface deformation using an optical surface tracking system. Radiol Phys Technol 2022; 15:367-378. [PMID: 36040622 DOI: 10.1007/s12194-022-00676-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 08/16/2022] [Accepted: 08/17/2022] [Indexed: 11/24/2022]
Abstract
This study aimed to develop a new method to quantitatively analyze body shape changes in patients during radiotherapy without additional radiation exposure using an optical surface tracking system. This method's accuracy was evaluated using a cubic phantom with a known shift. Surface images of three-dimensionally printed phantoms, which simulated the head and neck shapes of real patients before and after treatment, were used to create a deformation surface area histogram. The near-maximum deformation value covering an area of 2 cm2 in the surface image (Def-2cm2) was calculated. A volumetric modulated arc therapy (VMAT) plan was also created on the pre-treatment phantom, and the dose distribution was recalculated on the post-treatment phantom to compare the dose indices. Surface images of four patients were analyzed to evaluate Def-2cm2 and examine whether this method can be used in clinical cases. Experiments with the cubic phantom resulted in a mean deformation error of 0.08 mm. With head and neck phantoms, the Def-2cm2 value was 17.5 mm, and the dose that covered 95% of the planning target volume in the VMAT plan decreased by 11.7%, indicating that deformation of the body surface may affect the dose distribution. Although analysis of the clinical data showed no clinically relevant deformation in any of the cases, slight skin sagging and respiratory changes in the body surface were observed. The proposed method can quantitatively and accurately evaluate the deformation of a body surface. This method is expected to be used to make decisions regarding modifications to treatment plans.
Collapse
Affiliation(s)
- Kimihiko Sato
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan
- Department of Radiology, Nihonkai General Hospital, 30 Akiho-chou, Sakata, Yamagata, 998-8501, Japan
| | - Takayuki Kanai
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan.
| | - Sung Hyun Lee
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan
| | - Yuya Miyasaka
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan
| | - Hongbo Chai
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan
| | - Hikaru Souda
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan
| | - Takeo Iwai
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan
| | - Ryuji Sato
- Department of Radiology, Nihonkai General Hospital, 30 Akiho-chou, Sakata, Yamagata, 998-8501, Japan
| | - Naoki Goto
- Department of Radiology, Nihonkai General Hospital, 30 Akiho-chou, Sakata, Yamagata, 998-8501, Japan
| | - Tsukasa Kawamura
- Department of Radiology, Nihonkai General Hospital, 30 Akiho-chou, Sakata, Yamagata, 998-8501, Japan
| |
Collapse
|
20
|
Kaučić H, Kosmina D, Schwarz D, Mack A, Čehobašić A, Leipold V, Avdićević A, Mlinarić M, Lekić M, Schwarz K, Banović M. Stereotactic Body Radiotherapy for Locally Advanced Pancreatic Cancer Using Optical Surface Management System - AlignRT as an Optical Body Surface Motion Management in Deep Breath Hold Patients: Results from a Single-Arm Retrospective Study. Cancer Manag Res 2022; 14:2161-2172. [PMID: 35855763 PMCID: PMC9288179 DOI: 10.2147/cmar.s368662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 06/22/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To assess the efficacy and safety of stereotactic body radiotherapy for patients with unresectable, locally advanced pancreatic cancer using Optical Surface Management System - AlignRT (OSMS-AlignRT) as an optical body surface motion management in deep breath hold. Patients and Methods Forty-five patients diagnosed with locally advanced pancreatic cancer were treated with stereotactic body radiotherapy in 3 or 5 fractions, and received varying BED10 (median 79.5 Gy) from April 2017 to December 2020. All patients were treated in deep breath hold with OSMS-AlignRT used as optical body surface motion management. Thirty-three patients received systemic treatment before and/or after stereotactic body radiotherapy, and twelve patients received no systemic treatment. In this retrospective, observational, single-arm study, primary endpoints were overall survival and freedom from local progression (ie, local control). Secondary endpoints were progression-free survival and toxicity. Actuarial survival analysis and univariate analysis were investigated. Results Data from forty-five patients were analyzed. Median follow-up was 15 months. One-year freedom from local progression and survival were 95.5% and 71.1%, respectively. Median progression-free survival was 14 months. Median overall survival from diagnosis for all patients was 17 months, and 19 months for patients alive at the time of analysis. No patient had >G2 toxicity. Conclusion Stereotactic body radiotherapy for locally advanced pancreatic cancer using OSMS-AlignRT as optical body surface motion management in deep breath hold patients is an effective and safe local treatment option, with no >G2 toxicity, and could be a promising therapeutic option with acceptable toxicity, either as a single treatment or in a multimodal regimen. OSMS-AlignRT provided accurate and reliable body surface motion management during stereotactic body radiotherapy.
Collapse
Affiliation(s)
- Hrvoje Kaučić
- Department of Radiosurgery and Radiotherapy, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia.,University Josip Juraj Strossmayer in Osijek - Medical Faculty Osijek, Osijek, Croatia
| | - Domagoj Kosmina
- Department of Medical Physics, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia
| | - Dragan Schwarz
- Department of Surgery, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia.,Department of Surgery, Medical Faculty of University in Rijeka, Rijeka, Croatia.,Department of Surgery, University Josip Juraj Strossmayer in Osijek - Faculty of Dental medicine and Health, Osijek, Croatia
| | - Andreas Mack
- Swiss NeuroRadiosurgery Center, Swiss Clinical NeuroScience Institute, Zürich, Switzerland
| | - Adlan Čehobašić
- University Josip Juraj Strossmayer in Osijek - Medical Faculty Osijek, Osijek, Croatia.,Department of Medical Physics, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia
| | - Vanda Leipold
- University Josip Juraj Strossmayer in Osijek - Medical Faculty Osijek, Osijek, Croatia.,Department of Medical Physics, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia
| | - Asmir Avdićević
- Department of Radiosurgery and Radiotherapy, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia
| | - Mihaela Mlinarić
- Department of Medical Physics, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia
| | - Matea Lekić
- Department of Radiosurgery and Radiotherapy, Special Hospital Radiochirurgia Zagreb, Sveta Nedelja, Croatia
| | - Karla Schwarz
- University of Zagreb, Medical Faculty, Zagreb, Croatia
| | - Marija Banović
- Department of Endocrinology, Polyclinic Leptir, Zagreb, Croatia
| |
Collapse
|
21
|
Naidoo W, Leech M. Feasibility of surface guided radiotherapy for patient positioning in breast radiotherapy versus conventional tattoo-based setups- a systematic review. Tech Innov Patient Support Radiat Oncol 2022; 22:39-49. [PMID: 35481261 PMCID: PMC9035716 DOI: 10.1016/j.tipsro.2022.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 02/07/2022] [Accepted: 03/09/2022] [Indexed: 11/17/2022] Open
Abstract
Background Traditionally tattoos are used for patient setup in radiotherapy. However they may pose challenges for the radiotherapists to achieve precise patient alignment, and serve as a permanent visual reminder of the patient’s diagnosis and often challenging cancer journey. The psychological impact of tattoos has been recognized in recent years. The increasing complexity of treatment techniques and the utilization of hypofractionated regimes, requires an enhanced level of accuracy and safety. Surface guided radiotherapy (SGRT) enables improvements in the accuracy and reproducibility of patient isocentric and postural alignment, enhanced efficiency, and safety in breast radiotherapy. Purpose The aim of this review was to compare the accuracy and reproducibility of SGRT to conventional tattoo-based setups in free-breathing breast radiotherapy and to determine if SGRT can reduce the frequency of routine image guided radiotherapy (IGRT). Materials and Methods A systematic literature review was performed as per PRISMA guidelines. Papers identified through PubMed, Embase, Web of Science and Google Scholar database searches between 2010 and 2021, were critically appraised. Systematic, random, mean residual errors and 3D vector shifts as determined by IGRT verification were analysed. Results A review of 13 full papers suggests SGRT improves the accuracy and reproducibility of patient setup in breast radiotherapy with consistent reductions in the residual errors. There appears to be a good correlation between SGRT setups and radiographic imaging. The frequency of IGRT and the corresponding dose could potentially be reduced. Additionally, SGRT improves treatment efficiency. Conclusion SGRT appears to have improved the accuracy and reproducibility of patient setup and treatment efficiency of breast radiotherapy compared to conventional tattoo/laser-based method, with the potential to reduce the frequency of routine IGRT. The reliance on tattoos in breast radiotherapy are likely to become obsolete with positive implications for both patients and clinical practice.
Collapse
|
22
|
Lawler G. A review of surface guidance in extracranial stereotactic body radiotherapy (SBRT/SABR) for set-up and intra-fraction motion management. Tech Innov Patient Support Radiat Oncol 2022; 21:23-26. [PMID: 35079644 PMCID: PMC8777133 DOI: 10.1016/j.tipsro.2022.01.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/20/2021] [Accepted: 01/06/2022] [Indexed: 12/25/2022] Open
Abstract
Introduction Surface guidance (SG) radiotherapy (RT) is now used by many radiotherapy departments globally and has expanded in popularity over the last number of years. A number of commercial systems are available. SG has routinely been used and is well established for cranial stereotactic radiosurgery (SRS) patient set ups and intra-fraction motion monitoring. However, data is limited in relation to its clinical use for extracranial stereotactic body radiotherapy (SBRT), particularly for targets which are impacted by respiratory motion such as the lung and liver. Objective & Information Source A review of available literature was carried out on 24th October 2021 to assess the clinical feasibility and use of SG in SBRT via PubMed. Methods Eligibility Criteria The search criteria involved identifying articles where SG is used in extracranial SBRT. Risk of Bias To eliminate the risk of bias, any particular commercial system was not the focus of the review and not included in the search criteria. Numerous clinical terms for similar things were used to reduce the risk of missing papers e.g. SBRT and SABR. Search Criteria The PRISMA checklist was used. Searching for “surface guidance and radiotherapy” yielded 3271 results, where as “SGRT” alone returned 72 results, when the search term was narrowed down using different iterations of SG and SBRT, only 6 results were available. Of these, 4 had reviewed clinical data in relation to SG and SBRT for patient set up and intra-fraction motion monitoring. Results The 4 studies indicate positive results for using SG with sufficient image guidance (IG) for both patient set up and intra-fraction monitoring during SBRT. This was observed both in free breathing and in patients with respiratory motion management being employed such as deep inspiration breath-hold (DIBH) techniques. All used multiple IGRT solutions to verify localisation pre-treatment in conjunction with SG. Limitations The number of studies available which report using SG in SBRT is extremely limited. All centres had also installed SG systems therefore this could result in an unconditional bias in using the system positively. Conclusion SG can be used for SBRT set-ups and intra-fraction motion monitoring once sufficient IG is used to verify target localisation for treatment.
Collapse
|
23
|
Li C, Lu Z, He M, Sui J, Lin T, Xie K, Sun J, Ni X. Augmented reality-guided positioning system for radiotherapy patients. J Appl Clin Med Phys 2022; 23:e13516. [PMID: 34985188 PMCID: PMC8906221 DOI: 10.1002/acm2.13516] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 11/18/2021] [Accepted: 12/15/2021] [Indexed: 01/22/2023] Open
Abstract
In modern radiotherapy, error reduction in the patients’ daily setup error is important for achieving accuracy. In our study, we proposed a new approach for the development of an assist system for the radiotherapy position setup by using augmented reality (AR). We aimed to improve the accuracy of the position setup of patients undergoing radiotherapy and to evaluate the error of the position setup of patients who were diagnosed with head and neck cancer, and that of patients diagnosed with chest and abdomen cancer. We acquired the patient's simulation CT data for the three‐dimensional (3D) reconstruction of the external surface and organs. The AR tracking software detected the calibration module and loaded the 3D virtual model. The calibration module was aligned with the Linac isocenter by using room lasers. And then aligned the virtual cube with the calibration module to complete the calibration of the 3D virtual model and Linac isocenter. Then, the patient position setup was carried out, and point cloud registration was performed between the patient and the 3D virtual model, such the patient's posture was consistent with the 3D virtual model. Twenty patients diagnosed with head and neck cancer and 20 patients diagnosed with chest and abdomen cancer in the supine position setup were analyzed for the residual errors of the conventional laser and AR‐guided position setup. Results show that for patients diagnosed with head and neck cancer, the difference between the two positioning methods was not statistically significant (P > 0.05). For patients diagnosed with chest and abdomen cancer, the residual errors of the two positioning methods in the superior and inferior direction and anterior and posterior direction were statistically significant (t = −5.80, −4.98, P < 0.05). The residual errors in the three rotation directions were statistically significant (t = −2.29 to −3.22, P < 0.05). The experimental results showed that the AR technology can effectively assist in the position setup of patients undergoing radiotherapy, significantly reduce the position setup errors in patients diagnosed with chest and abdomen cancer, and improve the accuracy of radiotherapy.
Collapse
Affiliation(s)
- Chunying Li
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Zhengda Lu
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Mu He
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Jianfeng Sui
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Tao Lin
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Kai Xie
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Jiawei Sun
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| | - Xinye Ni
- Department of Radiotherapy, Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.,Laboratory of Medical Physics Center, Nanjing Medical University, Jiangning District, Nanjing, China.,Changzhou Key Laboratory of Medical Physics, Changzhou, China
| |
Collapse
|
24
|
Blake N, Pereira L, Eaton DJ, Dobson D. Surface-guided radiotherapy for lung cancer can reduce the number of close patient contacts without compromising initial setup accuracy. Tech Innov Patient Support Radiat Oncol 2021; 20:61-63. [PMID: 34988300 PMCID: PMC8710980 DOI: 10.1016/j.tipsro.2021.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 11/10/2021] [Accepted: 11/19/2021] [Indexed: 01/21/2023] Open
Abstract
Surface-guided radiotherapy (SGRT) can assist with patient setup by providing a real-time feedback mechanism over the whole patient treatment surface. It also has the potential to reduce the number of close contacts between staff and the patient, which is advocated for infection control during the COVID-19 pandemic. Residual translations and rotations (post-CBCT) were acquired following a conventional setup protocol (using permanent marks and lasers) and an SGRT setup protocol. The SGRT protocol resulted in one of the two therapeutic radiographers not having any close contact (<2m) with a patient during setup. Data from 702 imaging sessions showed similar setup accuracy with either protocol, fewer large translations and fewer repeat setup occurrences using the SGRT protocol. The potential of SGRT for infection control should be recognised alongside other benefits.
Collapse
Affiliation(s)
- Nicola Blake
- Department of Radiotherapy, Guy’s and St Thomas’ NHS Foundation Trust, London, UK,Corresponding author at: Guy’s Cancer Centre, London SE1 9RT, UK.
| | - Luciano Pereira
- Department of Radiotherapy, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - David J Eaton
- Department of Medical Physics, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - Deirdre Dobson
- Department of Radiotherapy, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| |
Collapse
|
25
|
Crockett C, Salem A, Thippu Jayaprakash K. Shooting the Star: Mitigating Respiratory Motion in Lung Cancer Radiotherapy. Clin Oncol (R Coll Radiol) 2021; 34:160-163. [PMID: 34893390 DOI: 10.1016/j.clon.2021.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 11/03/2021] [Accepted: 11/18/2021] [Indexed: 11/30/2022]
Affiliation(s)
- C Crockett
- Radiotherapy Related Research, The Christie NHS Foundation Trust, Manchester, UK.
| | - A Salem
- Radiotherapy Related Research, The Christie NHS Foundation Trust, Manchester, UK; Division of Cancer Sciences, University of Manchester, Manchester, UK
| | - K Thippu Jayaprakash
- Oncology Centre, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK; Department of Oncology, The Queen Elizabeth Hospital King's Lynn NHS Foundation Trust, King's Lynn, UK
| |
Collapse
|
26
|
The role of surface-guided radiation therapy for improving patient safety. Radiother Oncol 2021; 163:229-236. [PMID: 34453955 DOI: 10.1016/j.radonc.2021.08.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 07/27/2021] [Accepted: 08/11/2021] [Indexed: 11/20/2022]
Abstract
Emerging data indicates SGRT could improve safety and quality by preventing errors in its capacity as an independent system in the treatment room. The aim of this work is to investigate the utility of SGRT in the context of safety and quality. Three incident learning systems (ILS) were reviewed to categorize and quantify errors that could have been prevented with SGRT: SAFRON (International Atomic Energy Agency), UW-ILS (University of Washington) and AvIC (Skåne University Hospital). A total of 849/9737 events occurred during the pre-treatment review/verification and treatment stages. Of these, 179 (21%) events were predicted to have been preventable with SGRT. The most common preventable events were wrong isocentre (43%) and incorrect accessories (34%), which appeared at comparable rates among SAFRON and UW-ILS. The proportion of events due to wrong accessories was much smaller in the AvIC ILS, which may be attributable to the mandatory use of SGRT in Sweden. Several case scenarios are presented to demonstrate that SGRT operates as a valuable complement to other quality-improvement tools routinely used in radiotherapy. Cases are noted in which SGRT itself caused incidents. These were mostly related to workflow issues and were of low severity. Severity data indicated that events with the potential to be mitigated by SGRT were of higher severity for all categories except wrong accessories. Improved vendor integration of SGRT systems within the overall workflow could further enhance its clinical utility. SGRT is a valuable tool with the potential to increase patient safety and treatment quality in radiotherapy.
Collapse
|
27
|
Sarudis S, Karlsson A, Bäck A. Surface guided frameless positioning for lung stereotactic body radiation therapy. J Appl Clin Med Phys 2021; 22:215-226. [PMID: 34406710 PMCID: PMC8425933 DOI: 10.1002/acm2.13370] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/10/2021] [Accepted: 07/05/2021] [Indexed: 12/25/2022] Open
Abstract
Background and purpose When treating lung tumors with stereotactic body radiation therapy (SBRT), patient immobilization is of outmost importance. In this study, the intra‐fractional shifts of the patient (based on bony anatomy) and the tumor (based on the visible target volume) are quantified, and the associated impact on the delivered dose is estimated for a frameless immobilization approach in combination with surface guided radiation therapy (SGRT) monitoring. Methods Cone beam computed tomographies (CBCT) were collected in free breathing prior and after each treatment for 25 patients with lung tumors, in total 137 fractions. The CBCT collected after each treatment was registered to the CBCT collected before each treatment with focus on bony anatomy to determine the shift of the patient, and with focus on the visible target volume to determine the shift of the tumor. Rigid registrations with 6 degrees of freedom were used. The patients were positioned in frameless immobilizations with their position and respiration continuously monitored by a commercial SGRT system. The patients were breathing freely within a preset gating window during treatment delivery. The beam was automatically interrupted if isocenter shifts >4 mm or breathing amplitudes outside the gating window were detected by the SGRT system. The time between the acquisition of the CBCTs was registered for each fraction to examine correlations between treatment time and patient shift. The impact of the observed shifts on the dose to organs at risk (OAR) and the gross tumor volume (GTV) was assessed. Results The shift of the patient in the CBCTs was ≤2 mm for 132/137 fractions in the vertical (vrt) and lateral (lat) directions, and 134/137 fractions in the longitudinal (lng) direction and ≤4 mm in 134/137 (vrt) and 137/137 (lat, lng) of the fractions. The shift of the tumor was ≤2 mm in 116/137 (vrt), 123/137 (lat) and 115/137 (lng) fractions and ≤4 mm in 136/137 (vrt), 137/137 (lat), and 135/137 (lng) fractions. The maximal observed shift in the evaluated CBCT data was 4.6 mm for the patient and 7.2 mm for the tumor. Rotations were ≤3.3ᵒ for all fractions and the mean/standard deviation were 0.2/1.0ᵒ (roll), 0.1/0.8ᵒ (yaw), and 0.3/1.0ᵒ (pitch). The SGRT system interrupted the beam due to intra‐fractional isocenter shifts >4 mm for 21% of the fractions, but the patients always returned within tolerance without the need of repositioning. The maximal observed isocenter shift by the SGRT system during the beam holds was 8 mm. For the respiration monitoring, the beam was interrupted at least one time for 54% of the fractions. The visual tumor was within the planned internal target volume (ITV) for 136/137 fractions in the evaluated CBCT data collected at the end of each fraction. For the fraction where the tumor was outside the ITV, the D98% for the GTV decreased with 0.4 Gy. For the OARs, the difference between planned and estimated dose from the CBCT data (D2% or Dmean) was ≤2.6% of the prescribed PTV dose. No correlation was found between treatment time and the magnitude of the patient shift. Conclusions Using SGRT for motion management and respiration monitoring in combination with a frameless immobilization is a feasible approach for lung SBRT.
Collapse
Affiliation(s)
- Sebastian Sarudis
- Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden.,Department of Medical Physics, County Hospital Ryhov, Jönköping, Sweden
| | - Anna Karlsson
- Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden.,Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Göteborg, Sweden
| | - Anna Bäck
- Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden.,Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Göteborg, Sweden
| |
Collapse
|
28
|
Finazzi T, Schneiders FL, Senan S. Developments in radiation techniques for thoracic malignancies. Eur Respir Rev 2021; 30:30/160/200224. [PMID: 33952599 DOI: 10.1183/16000617.0224-2020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 10/27/2020] [Indexed: 12/25/2022] Open
Abstract
Radiation therapy is a cornerstone of modern lung cancer treatment alongside surgery, chemotherapy, immunotherapy and targeted therapies. Advances in radiotherapy techniques have enhanced the accuracy of radiation delivery, which has contributed to the evolution of radiation therapy into a guideline-recommended treatment in both early-stage and locally advanced nonsmall cell lung cancer. Furthermore, although radiotherapy has long been used for palliation of disease in advanced lung cancer, it is increasingly having a role as a locally ablative treatment in patients with oligometastatic disease.This review provides an overview of recent developments in radiation techniques, particularly for non-radiation oncologists who are involved in the care of lung cancer patients. Technical advances are discussed, and findings of recent clinical trials are highlighted, all of which have led to a changing perception of the role of radiation therapy in multidisciplinary care.
Collapse
Affiliation(s)
- Tobias Finazzi
- Clinic of Radiotherapy and Radiation Oncology, University Hospital Basel, Basel, Switzerland
| | - Famke L Schneiders
- Dept of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, Amsterdam, The Netherlands
| | - Suresh Senan
- Dept of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, Amsterdam, The Netherlands
| |
Collapse
|
29
|
Naumann P, Batista V, Farnia B, Fischer J, Liermann J, Tonndorf-Martini E, Rhein B, Debus J. Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold. Front Oncol 2020; 10:573279. [PMID: 33102232 PMCID: PMC7546313 DOI: 10.3389/fonc.2020.573279] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 09/08/2020] [Indexed: 12/25/2022] Open
Abstract
Background Reductions in tumor movement allow for more precise and accurate radiotherapy with decreased dose delivery to adjacent normal tissue that is crucial in stereotactic body radiotherapy (SBRT). Deep inspiration breath-hold (DIBH) is an established approach to mitigate respiratory motion during radiotherapy. We assessed the feasibility of combining modern optical surface-guided radiotherapy (SGRT) and image-guided radiotherapy (IGRT) to ensure and monitor reproducibility of DIBH and to ensure accurate tumor localization for SBRT as an imaging-guided precision medicine. Methods We defined a new workflow for delivering SBRT in DIBH for lung and liver tumors incorporating SGRT and IGRT with cone beam computed tomography (CBCT) twice per treatment fraction. Daily position corrections were analyzed and for every patient two points retrospectively characterized: an anatomically stable landmark (predominately Schmorl's nodes or spinal enostosis) and a respiratory-dependent landmark (predominately surgical clips or branching vessel). The spatial distance of these points was compared for each CBCT and used as surrogate for intra- and interfractional variability. Differences between the lung and liver targets were assessed using the Welch t-test. Finally, the planning target volumes were compared to those of free-breathing plans, prepared as a precautionary measure in case of technical or patient-related problems with DIBH. Results Ten patients were treated with SBRT according this workflow (7 liver, 3 lung). Planning target volumes could be reduced significantly from an average of 148 ml in free breathing to 110 ml utilizing DIBH (p < 0.001, paired t-test). After SGRT-based patient set-up, subsequent IGRT in DIBH yielded significantly higher mean corrections for liver targets compared to lung targets (9 mm vs. 5 mm, p = 0.017). Analysis of spatial distance between the fixed and moveable landmarks confirmed higher interfractional variability (interquartile range (IQR) 6.8 mm) than intrafractional variability (IQR 2.8 mm). In contrast, lung target variability was low, indicating a better correlation of patients' surface to lung targets (intrafractional IQR 2.5 mm and interfractional IQR 1.7 mm). Conclusion SBRT in DIBH utilizing SGRT and IGRT is feasible and results in significantly lower irradiated volumes. Nevertheless, IGRT is of paramount importance given that interfractional variability was high, particularly for liver tumors.
Collapse
Affiliation(s)
- Patrick Naumann
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Vania Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Benjamin Farnia
- Department of Radiation Oncology, University of Miami, Miami, FL, United States
| | - Jann Fischer
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Jakob Liermann
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Eric Tonndorf-Martini
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Bernhard Rhein
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
30
|
Batista V, Meyer J, Kügele M, Al-Hallaq H. Clinical paradigms and challenges in surface guided radiation therapy: Where do we go from here? Radiother Oncol 2020; 153:34-42. [PMID: 32987044 DOI: 10.1016/j.radonc.2020.09.041] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/17/2020] [Accepted: 09/18/2020] [Indexed: 12/26/2022]
Abstract
Surface guided radiotherapy (SGRT) is becoming a routine tool for patient positioning for specific clinical sites in many clinics. However, it has not yet gained its full potential in terms of widespread adoption. This vision paper first examines some of the difficulties in transitioning to SGRT before exploring the current and future role of SGRT alongside and in concert with other imaging techniques. Finally, future horizons and innovative ideas that may shape and impact the direction of SGRT going forward are reviewed.
Collapse
Affiliation(s)
- Vania Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Germany; Heidelberg Institute of Radiation Oncology (HIRO), Germany; National Center for Tumor Diseases (NCT), Heidelberg, Germany.
| | - Juergen Meyer
- Seattle Cancer Care Alliance, University of Washington, Department of Radiation Oncology, United States.
| | - Malin Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden; Medical Radiation Physics, Department of Clinical Sciences, Lund University, Sweden.
| | - Hania Al-Hallaq
- The University of Chicago, Department of Radiation and Cellular Oncology, United States.
| |
Collapse
|