1
|
Malone C, Ryan S, Nicholson J, McArdle O, Brennan S, McCavana P, McClean B, Duane F. Intrafraction Motion in Surface-Guided Breast Radiation Therapy and its Implications on a Single Planning Target Volume Margin Strategy. Pract Radiat Oncol 2024:S1879-8500(24)00196-6. [PMID: 39142389 DOI: 10.1016/j.prro.2024.06.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 06/05/2024] [Accepted: 06/25/2024] [Indexed: 08/16/2024]
Abstract
PURPOSE This study quantifies intrafraction motion in surface-guided radiation therapy (SGRT) for breast cancer and considers the need for individualized intrafraction motion measures when calculating planning target volume (PTV) margins. METHODS AND MATERIALS SGRT was used to assess intrafraction motion in consecutive patients according to (1) site irradiated (whole-breast/chest wall vs whole-breast/chest wall + regional lymph nodes) and (2) the use of deep inspiration breath hold versus free breathing. Intrafraction motion variation was evaluated throughout the treatment course for all cases. Associations between intrafraction motion and patient-specific characteristics were explored. The usefulness of individualized intrafraction motion measures for PTV margin determination was considered. RESULTS One hundred two patients undergoing 1360 fractions were included. On a population level, average intrafraction motion was less than 0.4 mm and 0.2 degrees for translational and rotational directions, respectively, with 95th percentiles <1.2 mm and 0.6 degrees, respectively. No clinically meaningful differences in intrafraction motion were observed according to the site irradiated or the use of deep inspiration breath hold. Consistency in intrafraction motion was noted for all patients throughout the treatment course. No clinically meaningful associations were found between intrafraction motion and patient-specific characteristics such as age, seroma volume, PTV volume, and mean body volume. CONCLUSIONS Intrafractional deviations with SGRT, using manufacturer-recommended regions of interest, are minimal, do not vary substantially for different treatment techniques or patient-specific characteristics, and remain constant throughout the treatment course. A universal intrafraction motion measure may be sufficient for calculating PTV margins. Further validation studies are needed to evaluate the impact of region of interest size and coverage.
Collapse
Affiliation(s)
- Ciaran Malone
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland.
| | - Samantha Ryan
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland
| | - Jill Nicholson
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland; Discipline of Radiation Therapy, Trinity St James's Cancer Institute, Trinity College Dublin, Dublin, Ireland
| | - Orla McArdle
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland
| | - Sinead Brennan
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland; Discipline of Radiation Therapy, Trinity St James's Cancer Institute, Trinity College Dublin, Dublin, Ireland
| | - Pat McCavana
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland
| | - Brendan McClean
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland; UCD School of Physics, University College Dublin, Belfield, Dublin, Ireland
| | - Frances Duane
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland; Discipline of Radiation Therapy, Trinity St James's Cancer Institute, Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
2
|
Leipold V, Alerić I, Mlinarić M, Kosmina D, Stanić F, Kasabašić M, Štimac D, Kaučić H, Ursi G, Schwarz K, Nikolić I, Klapan D, Schwarz D. Optimizing Choice of Skin Surrogates for Surface-Guided Stereotactic Body Radiotherapy of Lung Lesions Using Four-Dimensional Computed Tomography. Cancers (Basel) 2024; 16:2358. [PMID: 39001420 PMCID: PMC11240798 DOI: 10.3390/cancers16132358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 06/23/2024] [Accepted: 06/25/2024] [Indexed: 07/16/2024] Open
Abstract
Image-guided radiotherapy supported by surface guidance can help to track lower lung lesions' respiratory motion while reducing a patient's exposure to ionizing radiation. However, it is not always clear how the skin's respiratory motion magnitude and its correlation with the lung lesion's respiratory motion vary between different skin regions of interest (ROI). Four-dimensional computed tomography (4DCT) images provide information on both the skin and lung respiratory motion and are routinely acquired for the purpose of treatment planning in our institution. An analysis of 4DCT images for 57 patients treated in our institution has been conducted to provide information on the respiratory motion magnitudes of nine skin ROIs of the torso, a tracking structure (TS) representing a lower lung lobe lesion, as well as the respiratory motion correlations between the nine ROIs and the TS. The effects of gender and the adipose tissue volume and distribution on these correlations and magnitudes have been analyzed. Significant differences between the ROIs in both the respiratory motion magnitudes and their correlations with the TS have been detected. An overall negative correlation between the ROI respiratory magnitudes and the adipose tissue has been detected for ROIs with rib cage support. A weak to moderate negative correlation between the adipose tissue volume and ROI-to-TS respiratory correlations has been detected for upper thorax ROIs. The respiratory magnitudes in regions without rib support tend to be larger for men than for women, but no differences in the ROI-to-TS correlation between sexes have been detected. The described findings should be considered when choosing skin surrogates for lower lung lesion motion management.
Collapse
Affiliation(s)
- Vanda Leipold
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Ivana Alerić
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Mihaela Mlinarić
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Domagoj Kosmina
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Fran Stanić
- Bitwise Solutions d.o.o., 10000 Zagreb, Croatia
| | - Mladen Kasabašić
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
| | - Damir Štimac
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
| | - Hrvoje Kaučić
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Giovanni Ursi
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
| | - Karla Schwarz
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Igor Nikolić
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
- School of Medicine, University of Mostar, 88000 Mostar, Bosnia and Herzegovina
| | - Denis Klapan
- Faculty of Dental Medicine and Health Osijek, 31000 Osijek, Croatia
| | - Dragan Schwarz
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia
- Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia (D.K.); (H.K.)
- Faculty of Medicine, Juraj Dobrila University of Pula, 52100 Pula, Croatia
| |
Collapse
|
3
|
Buschmann M, Kauer-Dorner D, Konrad S, Georg D, Widder J, Knäusl B. Stereoscopic X-ray image and thermo-optical surface guidance for breast cancer radiotherapy in deep inspiration breath-hold. Strahlenther Onkol 2024; 200:306-313. [PMID: 37796341 DOI: 10.1007/s00066-023-02153-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 08/30/2023] [Indexed: 10/06/2023]
Abstract
PURPOSE To investigate the feasibility of a thermo-optical surface imaging (SGRT) system combined with room-based stereoscopic X‑ray image guidance (IGRT) in a dedicated breast deep inspiration breath-hold (DIBH) irradiation workflow. In this context, benchmarking of portal imaging (EPID) and cone-beam CT (CBCT) against stereoscopic X‑rays was performed. METHODS SGRT + IGRT data of 30 left-sided DIBH breast patients (1 patient with bilateral cancer) treated in 351 fractions using thermo-optical surface imaging and X-ray IGRT were retrospectively analysed. Patients were prepositioned based on a free-breathing surface reference derived from a CT scan. Once the DIBH was reached using visual feedback, two stereoscopic X‑ray images were acquired and registered to the digitally reconstructed radiographs derived from the DIBH CT. Based on this registration, a couch correction was performed. Positioning and monitoring by surface and X-ray imaging were verified by protocol-based EPID or CBCT imaging at selected fractions and the calculation of residual geometric deviations. RESULTS The median X‑ray-derived couch correction vector was 4.9 (interquartile range [IQR] 3.3-7.1) mm long. Verification imaging was performed for 134 fractions (216 RT field verifications) with EPID and for 37 fractions with CBCT, respectively. The median 2D/3D deviation vector length over all verification images was 2.5 (IQR 1.6-3.9) mm/3.4 (IQR 2.2-4.8) mm for EPID/CBCT, both being well within the planning target volume (PTV) margins (7 mm). A moderate correlation (0.49-0.65) was observed between the surface signal and X-ray position in DIBH. CONCLUSION DIBH treatments using thermo-optical SGRT and X-ray IGRT were feasible for breast cancer patients. Stereoscopic X‑ray positioning was successfully verified by standard IGRT techniques.
Collapse
Affiliation(s)
- Martin Buschmann
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Daniela Kauer-Dorner
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Stefan Konrad
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Dietmar Georg
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Joachim Widder
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Barbara Knäusl
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria.
| |
Collapse
|
4
|
Cui S, Li G, Kuo H, Zhao B, Li A, Cerviño LI. Development of automated region of interest selection algorithms for surface-guided radiation therapy of breast cancer. J Appl Clin Med Phys 2024; 25:e14216. [PMID: 38115768 PMCID: PMC10795445 DOI: 10.1002/acm2.14216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 11/13/2023] [Accepted: 11/16/2023] [Indexed: 12/21/2023] Open
Abstract
To investigate automation of the preparation of the region of interest (ROI) for surface-guided radiotherapy (SGRT) of the whole breast with two algorithms based on contour anatomies: using the body contour, and using the breast contour. The patient dataset used for modeling consisted of 39 breast cancer patients previously treated with SGRT. The patient's anatomical structures (body and ipsilateral breast) were retrieved from the planning system, and the clinical ROI (cROI) drawn by the planners was retrieved from the SGRT system for comparison. For the body-contour-based algorithm, a convolutional neural network (MobileNet-v2) was utilized to train a synthetic human model dataset to predict body joint locations. With the body joint location knowledge, an automated ROI (aROIbody ) can be created based on: (1) the superior-inferior (S-I) borders defined by the joint locations, (2) the left-right (L-R) borders defined with 3/4 of chest width, and (3) a curation of the ROI to avoid the ipsilateral armpit. For the breast-contour-based algorithm, an aROIbreast was created by first defining the ROI in the S-I direction with the ipsilateral breast boundaries. Other steps are the same as with the body-contour-based algorithm. Among the 39 patients, 24 patients were used to fine-tune the algorithm parameters, and the remaining 15 patients were used to evaluate the quality of the aROIs against the cROIs. A blinded evaluation was performed by three SGRT expert physicists to rate the acceptability and the quality (1-10 scale) of the aROIs and cROIs, and the dice similarity coefficient (DSC) was also calculated to compare the similarity between the aROIs and cROIs. The results showed that the average acceptability was 14/15 (range: 13/15-15/15) for cROIs, 13.3/15 (range: 13/15-14/15) for aROIbody , and 14.6/15 (range: 14/15-15/15) for aROIbreast . The average quality was 7.4 ± 0.8 for cROIs, 8.1 ± 1.2 for aROIbody , and 8.2 ± 0.9 for aROIbreast . The DSC with cROIs was 0.81 ± 0.06 for aROIbody , and 0.83 ± 0.04 for aROIbreast . The ROI creation time was ∼120 s for clinical, 1.3 s for aROIbody , and 1.2 s for aROIbreast . The proposed automated algorithms can improve the ROI compliance with the SGRT protocol, with a shortened preparation time. It is ready to be integrated into the clinical workflow for automated ROI preparation.
Collapse
Affiliation(s)
- Songye Cui
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkUSA
| | - Guang Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkUSA
| | - Hsiang‐Chi Kuo
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkUSA
| | - Bo Zhao
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkUSA
| | - Anyi Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkUSA
| | - Laura I. Cerviño
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkUSA
| |
Collapse
|
5
|
Psarras M, Stasinou D, Stroubinis T, Protopapa M, Zygogianni A, Kouloulias V, Platoni K. Surface-Guided Radiotherapy: Can We Move on from the Era of Three-Point Markers to the New Era of Thousands of Points? Bioengineering (Basel) 2023; 10:1202. [PMID: 37892932 PMCID: PMC10604452 DOI: 10.3390/bioengineering10101202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/10/2023] [Accepted: 10/14/2023] [Indexed: 10/29/2023] Open
Abstract
The surface-guided radiotherapy (SGRT) technique improves patient positioning with submillimeter accuracy compared with the conventional positioning technique of lasers using three-point tattoos. SGRT provides solutions to considerations that arise from the conventional setup technique, such as variability in tattoo position and the psychological impact of the tattoos. Moreover, SGRT provides monitoring of intrafractional motion. PURPOSE This literature review covers the basics of SGRT systems and examines whether SGRT can replace the traditional positioning technique. In addition, it investigates SGRT's potential in reducing positioning times, factors affecting SGRT accuracy, the effectiveness of live monitoring, and the impact on patient dosage. MATERIALS AND METHODS This study focused on papers published from 2016 onward that compared SGRT with the traditional positioning technique and investigated factors affecting SGRT accuracy and effectiveness. RESULTS/CONCLUSIONS SGRT provides the same or better results regarding patient positioning. The implementation of SGRT can reduce overall treatment time. It is an effective technique for detecting intrafraction patient motion, improving treatment accuracy and precision, and creating a safe and comfortable environment for the patient during treatment.
Collapse
Affiliation(s)
- Michalis Psarras
- Medical Physics Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Despoina Stasinou
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Theodoros Stroubinis
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Maria Protopapa
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Anna Zygogianni
- Radiation Oncology Unit, 1st Department of Radiology, Aretaieion University Hospital, Medical School, National and Kapodistrian University of Athens, 115 28 Athens, Greece
| | - Vassilis Kouloulias
- Radiation Oncology Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
| | - Kalliopi Platoni
- Medical Physics Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| |
Collapse
|
6
|
Sauer TO, Stillkrieg W, Ott OJ, Fietkau R, Bert C. Plan robustness analysis for threshold determination of SGRT-based intrafraction motion control in 3DCRT breast cancer radiation therapy. Radiat Oncol 2023; 18:158. [PMID: 37740237 PMCID: PMC10517562 DOI: 10.1186/s13014-023-02325-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 07/27/2023] [Indexed: 09/24/2023] Open
Abstract
PURPOSE The goal of this study was to obtain maximum allowed shift deviations from planning position in six degrees of freedom (DOF), that can serve as threshold values in surface guided radiation therapy (SGRT) of breast cancer patients. METHODS The robustness of conformal treatment plans of 50 breast cancer patients against 6DOF shifts was investigated. For that, new dose distributions were calculated on shifted computed tomography scans and evaluated with respect to target volume and spinal cord dose. Maximum allowed shift values were identified by imposing dose constraints on the target volume dose coverage for 1DOF, and consecutively, for 6DOF shifts using an iterative approach and random sampling. RESULTS Substantial decreases in target dose coverage and increases of spinal cord dose were observed. Treatment plans showed highly differing robustness for different DOFs or treated area. The sensitivity was particularly high if clavicular lymph nodes were irradiated, for shifts in lateral, vertical, roll or yaw direction, and showed partly pronounced asymmetries. Threshold values showed similar properties with an absolute value range of 0.8 mm to 5 mm and 1.4° to 5°. CONCLUSION The robustness analysis emphasized the necessity of taking differences between DOFs and asymmetrical sensitivities into account when evaluating the dosimetric impact of position deviations. It also highlighted the importance of rotational shifts, especially if clavicular lymph nodes were irradiated. A practical approach of determining 6DOF shift limits was introduced and a set of threshold values applicable for SGRT based patient motion control was identified.
Collapse
Affiliation(s)
- Tim-Oliver Sauer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Wilhelm Stillkrieg
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Oliver J. Ott
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Rainer Fietkau
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Christoph Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| |
Collapse
|
7
|
Song Y, Zhai X, Liang Y, Zeng C, Mueller B, Li G. Evidence-based region of interest (ROI) definition for surface-guided radiotherapy (SGRT) of abdominal cancers using deep-inspiration breath-hold (DIBH). J Appl Clin Med Phys 2022; 23:e13748. [PMID: 35946900 PMCID: PMC9680570 DOI: 10.1002/acm2.13748] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 04/27/2022] [Accepted: 07/20/2022] [Indexed: 01/19/2023] Open
Abstract
To define and evaluate the appropriate abdominal region of interest (ROI) as a surrogate of diaphragm positioning in deep-inspiration breath-hold (DIBH) for surface-guided radiotherapy (SGRT) of abdominal cancers using 3D optical surface imaging (OSI). Six potential abdominal ROIs were evaluated to calculate their correlations with the diaphragm position using 4DCT images of 20 abdominal patients. Twelve points of interest (POIs) were defined (six on the central soft tissue and six on the bilateral ribs) at three superior-inferior levels, and different sub-groups represented different ROIs. ROI-1 was the largest, containing all 12 POIs from the xiphoid to the umbilicus and between the lateral body midlines while ROI-2 had only eight inferior POIs, ROI-3 had six lateral POIs, and ROI-4 had four superior-lateral POIs over the ribs, ROI-5 contained six central and two most inferior-lateral POIs and ROI-6 contained six central and four inferior-lateral POIs. Internally, the right diaphragm dome was used to represent its positions in 4DCT (0% and 50% within the cycle). The Pearson correlation coefficients were calculated between the diaphragm dome and all 12 external POIs individually or grouped as six ROIs. The quality of the abdominal ROIs was evaluated as potential internal surrogates and, therefore, potential ROIs for SGRT DIBH setup. The four most inferior POIs show the highest mean correlation (r = 0.75) with diaphragmatic motion, and the correlation decreases as POIs move superiorly. The mean correlations are the highest for ROIs with little or no rib support: r = 0.67 for ROI-2, r = 0.64 for ROI-5, and r = 0.63 for ROI-6, while lower for ROIs with rib support: ROI-1 has r = 0.60, ROI-3 has r = 0.50, and ROI-4 has only r = 0.28. This study demonstrates that the rectangular/triangular soft-tissue ROI (with little rib support) is an optimal surrogate for body positioning and diaphragmatic motion, even when treating tumors under the rib cage. This evidence-based ROI definition should be utilized when treating abdominal cancers with free-breathing (FB) and/or DIBH setup.
Collapse
Affiliation(s)
- Yulin Song
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Xingchen Zhai
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Yubei Liang
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Chuan Zeng
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Boris Mueller
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Guang Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| |
Collapse
|
8
|
Freislederer P, Batista V, Öllers M, Buschmann M, Steiner E, Kügele M, Fracchiolla F, Corradini S, de Smet M, Moura F, Perryck S, Dionisi F, Nguyen D, Bert C, Lehmann J. ESTRO-ACROP guideline on surface guided radiation therapy. Radiother Oncol 2022; 173:188-196. [PMID: 35661677 DOI: 10.1016/j.radonc.2022.05.026] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 05/26/2022] [Indexed: 10/18/2022]
Abstract
Surface guidance systems enable patient positioning and motion monitoring without using ionising radiation. Surface Guided Radiation Therapy (SGRT) has therefore been widely adopted in radiation therapy in recent years, but guidelines on workflows and specific quality assurance (QA) are lacking. This ESTRO-ACROP guideline aims to give recommendations concerning SGRT roles and responsibilities and highlights common challenges and potential errors. Comprehensive guidelines for procurement, acceptance, commissioning, and QA of SGRT systems installed on computed tomography (CT) simulators, C-arm linacs, closed-bore linacs, and particle therapy treatment systems are presented that will help move to a consensus among SGRT users and facilitate a safe and efficient implementation and clinical application of SGRT.
Collapse
Affiliation(s)
- P Freislederer
- Department of Radiation Oncology, LMU University Hospital, Munich, Germany.
| | - V Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Germany; Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
| | - M Öllers
- Department of Radiotherapy, MAASTRO, Maastricht, The Netherlands
| | - M Buschmann
- Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Austria
| | - E Steiner
- Institute for Radiation Oncology and Radiotherapy, Landesklinikum Wiener Neustadt, Austria
| | - M Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - F Fracchiolla
- Azienda Provinciale per i Servizi Sanitari (APSS) Protontherapy Department, Trento, Italy
| | - S Corradini
- Department of Radiation Oncology, LMU University Hospital, Munich, Germany
| | - M de Smet
- Department of Medical Physics & Instrumentation, Institute Verbeeten, Tilburg, The Netherlands
| | - F Moura
- Hospital CUF Descobertas, Department of Radiation Oncology, Lisbon, Portugal
| | - S Perryck
- Department of Radiation Oncology, University Hospital Zürich, Switzerland
| | - F Dionisi
- Department of Radiation Oncology, IRCSS Regina Elena National Cancer Institute, Rome, Italy
| | - D Nguyen
- Centre de Radiothérapie de Mâcon, France
| | - C Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Germany
| | - J Lehmann
- Radiation Oncology Department, Calvary Mater Newcastle, Australia; School of Information and Physical Sciences, University of Newcastle, Australia; Institute of Medical Physics, University of Sydney, Australia
| |
Collapse
|
9
|
Sauer T, Ott OJ, Lahmer G, Fietkau R, Bert C. Region of interest optimization for radiation therapy of breast cancer. J Appl Clin Med Phys 2021; 22:152-160. [PMID: 34543500 PMCID: PMC8504613 DOI: 10.1002/acm2.13410] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 05/11/2021] [Accepted: 08/06/2021] [Indexed: 11/17/2022] Open
Abstract
PURPOSE The goal of this study was to investigate how the choice of the region of interest (ROI) affects the registration results of surface imaging for daily positioning of breast cancer patients. METHODS The AlignRT system (VisionRT, London) and the XVI Cone beam CT (CBCT; Elekta, Stockholm) installed on two Versa HD linacs (Elekta) were used in this study, which included 28 patients (160 fractions). In the clinical workflow, patients were prepositioned with AlignRT and then shifted in 6 degrees of freedom (DOF) according to the CBCT. A new reference capture was taken immediately afterward. Retrospectively, the surface capture resulting from prepositioning was registered to the latest reference capture. By varying the ROI used for registration, the surface-based results were optimized in terms of minimizing the deviation to the clinically applied CBCT shifts. Two sets of ROIs were used: one obtained by applying a variable margin to the breast surface, another by combining ROIs of anatomical structures, including the sternum and contralateral breast. RESULTS Registration results showed significant differences from one ROI to another. Generally, the results improved with increasing ROI size, especially for rotational DOFs. ROIs, including the axilla or supraclavicular lymph drainage region, did not yield an improved registration result. On the other hand, an ROI comprising the breast surface, sternum, and a belt caudal to the breasts decreased the average magnitude of the translational and rotational deviations by 6.6% and 30.8% (p < 0.01), respectively, compared to the breast surface only results. CONCLUSION The influence of the ROI choice on surface imaging registration results was analyzed and the surface-based shifts were compared to clinically applied CBCT shifts. An optimal ROI for the treatment of breast cancer patients, consisting of the breast surface, sternum, and a belt, was identified.
Collapse
Affiliation(s)
- Tim‐Oliver Sauer
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Oliver J. Ott
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Godehard Lahmer
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Rainer Fietkau
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Christoph Bert
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| |
Collapse
|