Fu Y, Zhang P, Fan Q, Cai W, Pham H, Rimner A, Cuaron J, Cervino L, Moran JM, Li T, Li X. Deep learning-based target decomposition for markerless lung tumor tracking in radiotherapy. Med Phys 2024; 51:4271-4282. [PMID: 38507259 DOI: 10.1002/mp.17039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 02/07/2024] [Accepted: 03/04/2024] [Indexed: 03/22/2024] Open
Abstract
BACKGROUND In radiotherapy, real-time tumor tracking can verify tumor position during beam delivery, guide the radiation beam to target the tumor, and reduce the chance of a geometric miss. Markerless kV x-ray image-based tumor tracking is challenging due to the low tumor visibility caused by tumor-obscuring structures. Developing a new method to enhance tumor visibility for real-time tumor tracking is essential. PURPOSE To introduce a novel method for markerless kV image-based tracking of lung tumors via deep learning-based target decomposition. METHODS We utilized a conditional Generative Adversarial Network (cGAN), known as Pix2Pix, to build a patient-specific model and generate the synthetic decomposed target image (sDTI) to enhance tumor visibility on the real-time kV projection images acquired by the onboard kV imager equipped on modern linear accelerators. We used 4DCT simulation images to generate the digitally reconstructed radiograph (DRR) and DTI image pairs for model training. We augmented the training dataset by randomly shifting the 4DCT in the superior-inferior, anterior-posterior, and left-right directions during the DRR and DTI generation process. We performed real-time 2D tumor tracking via template matching between the DTI generated from the CT simulation and the sDTI generated from the real-time kV projection images. We validated the proposed method using nine patients' datasets with implanted beacons near the tumor. RESULTS The sDTI can effectively improve the image contrast around the lung tumors on the kV projection images for the nine patients. With the beacon motion as ground truth, the tracking errors were on average 0.8 ± 0.7 mm in the superior-inferior (SI) direction and 0.9 ± 0.8 mm in the in-plane left-right (IPLR) direction. The percentage of successful tracking, defined as a tracking error less than 2 mm in the SI direction, is 92.2% on the 4312 tested images. The patient-specific model took approximately 12 h to train. During testing, it took approximately 35 ms to generate one sDTI, and 13 ms to perform the tumor tracking using template matching. CONCLUSIONS Our method offers the potential solution for nearly real-time markerless lung tumor tracking. It achieved a high level of accuracy and an impressive tracking rate. Further development of 3D lung tumor tracking is warranted.
Collapse
Affiliation(s)
- Yabo Fu
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Pengpeng Zhang
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Qiyong Fan
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Weixing Cai
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Hai Pham
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - John Cuaron
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Laura Cervino
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Jean M Moran
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Tianfang Li
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Xiang Li
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
2
|
Fan Q, Pham H, Li X, Zhang P, Zhang L, Fu Y, Huang B, Li C, Cuaron J, Cerviño L, Moran JM, Li T. Toward quantitative intrafractional monitoring in paraspinal SBRT using a proprietary software application: clinical implementation and patient results. Phys Med Biol 2024; 69:045015. [PMID: 38241714 DOI: 10.1088/1361-6560/ad2099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 01/19/2024] [Indexed: 01/21/2024]
Abstract
Objective.We report on paraspinal motion and the clinical implementation of our proprietary software that leverages Varian's intrafraction motion review (IMR) capability for quantitative tracking of the spine during paraspinal SBRT. The work is based on our prior development and analysis on phantoms.Approach.To address complexities in patient anatomy, digitally reconstructed radiographs (DRR's) that highlight only the spine or hardware were constructed as tracking reference. Moreover, a high-pass filter and first-pass coarse search were implemented to enhance registration accuracy and stability. For evaluation, 84 paraspinal SBRT patients with sites spanning across the entire vertebral column were enrolled with prescriptions ranging from 24 to 40 Gy in one to five fractions. Treatments were planned and delivered with 9 IMRT beams roughly equally distributed posteriorly. IMR was triggered every 200 or 500 MU for each beam. During treatment, the software grabbed the IMR image, registered it with the corresponding DRR, and displayed the motion result in near real-time on auto-pilot mode. Four independent experts completed offline manual registrations as ground truth for tracking accuracy evaluation.Main results.Our software detected ≥1.5 mm and ≥2 mm motions among 17.1% and 6.6% of 1371 patient images, respectively, in either lateral or longitudinal direction. In the validation set of 637 patient images, 91.9% of the tracking errors compared to manual registration fell within ±0.5 mm in either direction. Given a motion threshold of 2 mm, the software accomplished a 98.7% specificity and a 93.9% sensitivity in deciding whether to interrupt treatment for patient re-setup.Significance.Significant intrafractional motion exists in certain paraspinal SBRT patients, supporting the need for quantitative motion monitoring during treatment. Our improved software achieves high motion tracking accuracy clinically and provides reliable guidance for treatment intervention. It offers a practical solution to ensure accurate delivery of paraspinal SBRT on a conventional Linac platform.
Collapse
Affiliation(s)
- Qiyong Fan
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Hai Pham
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Xiang Li
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Pengpeng Zhang
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Lei Zhang
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Yabo Fu
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Bohong Huang
- Stony Brook University, Department of Applied Mathematics and Statistics, 100 Nicolls Rd, Stony Brook, NY 11794, United States of America
| | - Cindy Li
- Carnegie Mellon University, Mellon College of Science, 5000 Forbes Ave, Pittsburgh, PA 15213, United States of America
| | - John Cuaron
- Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, 1275 York Avenue, NY 10065, United States of America
| | - Laura Cerviño
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Jean M Moran
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| | - Tianfang Li
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, NY 10065, United States of America
| |
Collapse
|
3
|
Jank EA, Cetnar AJ. Exploring the Use of Contour-Based Intrafraction Motion Review for Spine Stereotactic Body Radiation Therapy Treatments. Adv Radiat Oncol 2024; 9:101351. [PMID: 38405323 PMCID: PMC10885588 DOI: 10.1016/j.adro.2023.101351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 08/07/2023] [Indexed: 02/27/2024] Open
Abstract
Purpose Patient motion during radiation therapy treatment is a concern, especially for spine stereotactic body radiation therapy cases where the sharper dose gradient presents a toxicity threat to the spinal cord. Intrafraction motion review (IMR) is an application used to monitor patient position during treatment. The presence of spinal fixation hardware presents an opportunity for motion tracking to manually pause the beam. Methods and Materials A cohort of 17 clinicians were shown a video of the imaging console during a simulated treatment. Participants decided after each triggered image if they would pause the treatment beam, indicating that they believed the phantom to have moved outside of clinical tolerance. A spine phantom with hardware intact was positioned on a motion platform, which was programmed to make shifts ranging in size from 0.5 to 1.5 mm. A 1-mm isotropic expansion contour from the hardware was overlayed on the triggered planar x-ray images using the IMR application. Results User perception sensitivity did not exceed 0.5 until there was a physical shift of 1.4 mm, indicating that most users will not be able to reliably discriminate submillimeter shifts using contour-based shift identification. Conclusions If adaptations to standard of care are implemented clinically, the proposed method should be evaluated and the role of training and education should be examined before implementation. However, contour-based IMR could still provide beneficial information for larger intrafraction motion during treatment and could be valuable for identifying gross anatomic motion during treatment.
Collapse
Affiliation(s)
- Erika A. Jank
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, Ohio
| | - Ashley J. Cetnar
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, Ohio
| |
Collapse
|
4
|
Cai W, Fan Q, Li F, He X, Zhang P, Cervino L, Li X, Li T. Markerless motion tracking with simultaneous MV and kV imaging in spine SBRT treatment-a feasibility study. Phys Med Biol 2023; 68:10.1088/1361-6560/acae16. [PMID: 36549010 PMCID: PMC9944511 DOI: 10.1088/1361-6560/acae16] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 12/22/2022] [Indexed: 12/24/2022]
Abstract
Objective. Motion tracking with simultaneous MV-kV imaging has distinct advantages over single kV systems. This research is a feasibility study of utilizing this technique for spine stereotactic body radiotherapy (SBRT) through phantom and patient studies.Approach. A clinical spine SBRT plan was developed using 6xFFF beams and nine sliding-window IMRT fields. The plan was delivered to a chest phantom on a linear accelerator. Simultaneous MV-kV image pairs were acquired during beam delivery. KV images were triggered at predefined intervals, and synthetic MV images showing enlarged MLC apertures were created by combining multiple raw MV frames with corrections for scattering and intensity variation. Digitally reconstructed radiograph (DRR) templates were generated using high-resolution CBCT reconstructions (isotropic voxel size (0.243 mm)3) as the reference for 2D-2D matching. 3D shifts were calculated from triangulation of kV-to-DRR and MV-to-DRR registrations. To evaluate tracking accuracy, detected shifts were compared to known phantom shifts as introduced before treatment. The patient study included a T-spine patient and an L-spine patient. Patient datasets were retrospectively analyzed to demonstrate the performance in clinical settings.Main results. The treatment plan was delivered to the phantom in five scenarios: no shift, 2 mm shift in one of the longitudinal, lateral and vertical directions, and 2 mm shift in all the three directions. The calculated 3D shifts agreed well with the actual couch shifts, and overall, the uncertainty of 3D detection is estimated to be 0.3 mm. The patient study revealed that with clinical patient image quality, the calculated 3D motion agreed with the post-treatment cone beam CT. It is feasible to automate both kV-to-DRR and MV-to-DRR registrations using a mutual information-based method, and the difference from manual registration is generally less than 0.3 mm.Significance. The MV-kV imaging-based markerless motion tracking technique was validated through a feasibility study. It is a step forward toward effective motion tracking and accurate delivery for spinal SBRT.
Collapse
Affiliation(s)
- Weixing Cai
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Qiyong Fan
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Feifei Li
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Xiuxiu He
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Pengpeng Zhang
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Laura Cervino
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Xiang Li
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| | - Tianfang Li
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, 1275 York Avenue, New York, NY 10065, United States of America
| |
Collapse
|