Magugliani G, Marranconi M, Liosi GM, Locatelli F, Gambirasio A, Trombetta L, Hertsyk V, Torri V, Galluccio F, Macerata E, Mossini E, Santi A, Mariani M, Bombardieri E, Vavassori V, Salmoiraghi P. Pilot scale validation campaign of gel dosimetry for pre-treatment quality assurance in stereotactic radiotherapy. Phys Med 2023; 114:103158. [PMID: 37806152 DOI: 10.1016/j.ejmp.2023.103158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 09/25/2023] [Accepted: 09/28/2023] [Indexed: 10/10/2023] Open
Abstract
PURPOSE Complex stereotactic radiotherapy treatment plans require prior verification. A gel dosimetry system was developed and tested to serve as a high-resolution 3D dosimeter for Quality Assurance (QA) purposes. MATERIALS AND METHODS A modified version of a polyacrylamide polymer gel dosimeter based on chemical response inhibition was employed. Different sample geometries (cuvettes and phantoms) were manufactured for calibration and QA acquisitions. Irradiations were performed with a Varian Trilogy linac, and analyses of irradiated gel dosimeters were performed via MRI with a 1.5 T Philips Achieva at 1 mm3 or 2 mm3 isotropic spatial resolution. To assess reliability of polymer gel data, 54 stereotactic clinical treatment plans were delivered both on dosimetric gel phantoms and on the Delta4 dosimeter. Results from the two devices were evaluated through a global gamma index over a range of acceptance criteria and compared with each other. RESULTS A quantitative and tunable control of dosimetric gel response sensitivity was achieved through chemical inhibition. An optimized MRI analysis protocol allowed to acquire high resolution phantom dose data in timeframes of ≈ 1 h. Conversion of gel dosimeter data into absorbed dose was achieved through internal calibration. Polymer gel dosimeters (2 mm3 resolution) and Delta4 presented an agreement within 4.8 % and 2.7 % at the 3 %/1 mm and 2 %/2 mm gamma criteria, respectively. CONCLUSIONS Gel dosimeters appear as promising tools for high resolution 3D QA. Added complexity of the gel dosimetry protocol may be justifiable in case of small target volumes and steep dose gradients.
Collapse
Affiliation(s)
- G Magugliani
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy.
| | - M Marranconi
- U. O. Medical Physics, Humanitas Gavazzeni, Bergamo, Italy
| | - G M Liosi
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy
| | - F Locatelli
- U. O. Medical Physics, Humanitas Gavazzeni, Bergamo, Italy
| | - A Gambirasio
- U. O. Medical Physics, Humanitas Gavazzeni, Bergamo, Italy
| | - L Trombetta
- U. O. Medical Physics, Humanitas Gavazzeni, Bergamo, Italy
| | - V Hertsyk
- Fondazione Humanitas per la Ricerca, Milano, Italy
| | - V Torri
- Department of Oncologic Research, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Milano, Italy
| | - F Galluccio
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy
| | - E Macerata
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy
| | - E Mossini
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy
| | - A Santi
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy
| | - M Mariani
- Department of Energy, Nuclear Engineering Division, Politecnico di Milano, Milano, Italy
| | - E Bombardieri
- Scientific Direction, Humanitas Gavazzeni, Bergamo, Italy
| | - V Vavassori
- U. O. Radiotherapy, Humanitas Gavazzeni, Bergamo, Italy
| | - P Salmoiraghi
- U. O. Medical Physics, Humanitas Gavazzeni, Bergamo, Italy
| |
Collapse
|
2
|
Chemical Overview of Gel Dosimetry Systems: A Comprehensive Review. Gels 2022; 8:gels8100663. [PMID: 36286165 PMCID: PMC9601373 DOI: 10.3390/gels8100663] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/17/2022] Open
Abstract
Advances in radiotherapy technology during the last 25 years have significantly improved both dose conformation to tumors and the preservation of healthy tissues, achieving almost real-time feedback by means of high-precision treatments and theranostics. Owing to this, developing high-performance systems capable of coping with the challenging requirements of modern ionizing radiation is a key issue to overcome the limitations of traditional dosimeters. In this regard, a deep understanding of the physicochemical basis of gel dosimetry, as one of the most promising tools for the evaluation of 3D high-spatial-resolution dose distributions, represents the starting point for developing new and innovative systems. This review aims to contribute thorough descriptions of the chemical processes and interactions that condition gel dosimetry outputs, often phenomenologically addressed, and particularly formulations reported since 2017.
Collapse
|