Herr DJ, Moncion A, Griffith KA, Marsh R, Grubb M, Bhatt A, Dominello M, Walker EM, Narayana V, Abu-Isa E, Vicini FA, Hayman JA, Pierce LJ. Factors Associated With Cardiac Radiation Dose Reduction After Hypofractionated Radiation Therapy for Localized, Left-Sided Breast Cancer in a Large Statewide Quality Consortium.
Int J Radiat Oncol Biol Phys 2024;
118:632-638. [PMID:
37797748 DOI:
10.1016/j.ijrobp.2023.09.013]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 08/31/2023] [Accepted: 09/09/2023] [Indexed: 10/07/2023]
Abstract
PURPOSE
Limiting cardiac radiation dose is important for minimizing long-term cardiac toxicity in patients with left-sided early-stage breast cancer.
METHODS AND MATERIALS
Prospectively collected dosimetric data were analyzed for patients undergoing moderately hypofractionated radiation therapy to the left breast within the Michigan Radiation Oncology Quality Consortium from 2016 to 2022. The mean heart dose (MHD) goal was progressively tightened from ≤2 Gy in 2016 to MHD ≤ 1.2 Gy in 2018. In 2021, a planning target volume (PTV) coverage goal was added, and the goal MHD was reduced to ≤1 Gy. Multivariate logistic regression models were developed to assess for covariates associated with meeting the MHD goals in 2016 to 2020 and the combined MHD/PTV coverage goal in 2021 to 2022.
RESULTS
In total, 4165 patients were analyzed with a median age of 64 years. Overall average cardiac metric compliance was 91.7%. Utilization of motion management increased from 41.8% in 2016 to 2020 to 46.5% in 2021 to 2022. Similarly, use of prone positioning increased from 12.2% to 22.2% in these periods. On multivariate analysis in the 2016 to 2020 cohort, treatment with motion management (odds ratio [OR], 5.20; 95% CI, 3.59-7.54; P < .0001) or prone positioning (OR, 3.21; 95% CI, 1.85-5.57; P < .0001) was associated with meeting the MHD goal, while receipt of boost (OR, 0.25; 95% CI, 0.17-0.39; P < .0001) and omission of hormone therapy (OR, 0.65; 95% CI, 0.49-0.88; P = .0047) were associated with not meeting the MHD goal. From 2021 to 2022, treatment with motion management (OR, 1.89; 95% CI, 1.12-3.21; P = .018) or prone positioning (OR, 3.71; 95% CI, 1.73-7.95; P = .0008) was associated with meeting the combined MHD/PTV goal, while larger breast volume (≥1440 cc; OR, 0.34; 95% CI, 0.13-0.91; P = .031) was associated with not meeting the combined goal.
CONCLUSIONS
In our statewide consortium, high rates of compliance with aggressive targets for limiting cardiac dose were achievable without sacrificing target coverage.
Collapse