1
|
Liu Z, Luo X, Yan-Do R, Wang Y, Xie X, Li Z, Cheng SH, Shi P. Vertebrates on a Chip: Noninvasive Electrical and Optical Mapping of Whole Brain Activity Associated with Pharmacological Treatments. ACS Chem Neurosci 2024; 15:2121-2131. [PMID: 38775291 DOI: 10.1021/acschemneuro.4c00158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2024] Open
Abstract
Mapping brain activities is necessary for understanding brain physiology and discovering new treatments for neurological disorders. Such efforts have greatly benefited from the advancement in technologies for analyzing neural activity with improving temporal or spatial resolution. Here, we constructed a multielectrode array based brain activity mapping (BAM) system capable of stabilizing and orienting zebrafish larvae for recording electroencephalogram (EEG) like local field potential (LFP) signals and brain-wide calcium dynamics in awake zebrafish. Particularly, we designed a zebrafish trap chip that integrates with an eight-by-eight surface electrode array, so that brain electrophysiology can be noninvasively recorded in an agarose-free and anesthetic-free format with a high temporal resolution of 40 μs, matching the capability typically achieved by invasive LFP recording. Benefiting from the specially designed hybrid system, we can also conduct calcium imaging directly on immobilized awake larval zebrafish, which further supplies us with high spatial resolution brain-wide activity data. All of these innovations reconcile the limitations of sole LFP recording or calcium imaging, emphasizing a synergy of combining electrical and optical modalities within one unified device for activity mapping across a whole vertebrate brain with both improved spatial and temporal resolutions. The compatibility with in vivo drug treatment further makes it suitable for pharmacology studies based on multimodal measurement of brain-wide physiology.
Collapse
Affiliation(s)
- Zhen Liu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China
| | - Xuan Luo
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China
| | - Richard Yan-Do
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering Hong Kong Science Park, Hong Kong SAR
| | - Yuan Wang
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China
| | - Xi Xie
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou 510006, China
| | - Zhongping Li
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, China
| | - Shuk Han Cheng
- Department of Biomedical Science, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China
| | - Peng Shi
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering Hong Kong Science Park, Hong Kong SAR
- Center of Super-Diamond and Advanced Films (COSDAF), City University of Hong Kong Kowloon, Hong Kong SAR
- Shenzhen Research Institute, City University of Hong Kong Shenzhen, Guangdong 518057, China
| |
Collapse
|
2
|
Khalili A, van Wijngaarden E, Zoidl GR, Rezai P. Simultaneous screening of zebrafish larvae cardiac and respiratory functions: a microfluidic multi-phenotypic approach. INTEGRATIVE BIOLOGY : QUANTITATIVE BIOSCIENCES FROM NANO TO MACRO 2022; 14:162-170. [PMID: 36416255 DOI: 10.1093/intbio/zyac015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/16/2022] [Accepted: 10/06/2022] [Indexed: 11/24/2022]
Abstract
Multi-phenotypic screening of multiple zebrafish larvae plays an important role in enhancing the quality and speed of biological assays. Many microfluidic platforms have been presented for zebrafish phenotypic assays, but multi-organ screening of multiple larvae, from different needed orientations, in a single device that can enable rapid and large-sample testing is yet to be achieved. Here, we propose a multi-phenotypic quadruple-fish microfluidic chip for simultaneous monitoring of heart activity and fin movement of 5-7-day postfertilization zebrafish larvae trapped in the chip. In each experiment, fin movements of four larvae were quantified in the dorsal view in terms of fin beat frequency (FBF). Positioning of four optical prisms next to the traps provided the lateral views of the four larvae and enabled heart rate (HR) monitoring. The device's functionality in chemical testing was validated by assessing the impacts of ethanol on heart and fin activities. Larvae treated with 3% ethanol displayed a significant drop of 13.2 and 35.8% in HR and FBF, respectively. Subsequent tests with cadmium chloride highlighted the novel application of our device for screening the effect of heavy metals on cardiac and respiratory function at the same time. Exposure to 5 $\mu$g/l cadmium chloride revealed a significant increase of 8.2% and 39.2% in HR and FBF, respectively. The device can be employed to monitor multi-phenotypic behavioral responses of zebrafish larvae induced by chemical stimuli in various chemical screening assays, in applications such as ecotoxicology and drug discovery.
Collapse
Affiliation(s)
- Arezoo Khalili
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| | | | - Georg R Zoidl
- Department of Biology, York University, Toronto, ON, Canada
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| |
Collapse
|
3
|
Qian C, Tong M, Yu X, Zhuang S. CNN-based visual processing approach for biological sample microinjection systems. Neurocomputing 2021. [DOI: 10.1016/j.neucom.2021.06.085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
4
|
Khalili A, van Wijngaarden E, Youssef K, Zoidl GR, Rezai P. Microfluidic devices for behavioral screening of multiple Zebrafish Larvae: Design investigation process. Biotechnol J 2021; 17:e2100076. [PMID: 34480402 DOI: 10.1002/biot.202100076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 08/25/2021] [Accepted: 08/30/2021] [Indexed: 11/11/2022]
Abstract
Microfluidic devices have been introduced for phenotypic screening of zebrafish larvae in both fundamental and pre-clinical research. One of the remaining challenges for the broad use of microfluidic devices is their limited throughput, especially in behavioural assays. Previously, we introduced the tail locomotion of a semi-mobile zebrafish larva evoked on-demand with electric signal in a microfluidic device. Here, we report the lessons learned for increasing the number of specimens from one to four larvae in this device. Multiple parameters including loading and testing time per fish and loading and orientation efficiencies were refined to optimize the performance of modified designs. Simulations of the flow and electric field within the final device provided insight into the flow behavior and functionality of traps when compared to previous single-larva devices. Outcomes led to a new design which decreased the testing time per larva by approximately 60%. Further, loading and orientation efficiencies increased by more than 80%. Critical behavioural parameters such as response duration and tail beat frequency were similar in both single and quadruple-fish devices. The developed microfluidic device has significant advantages for greater throughput and efficiency when behavioral phenotyping is required in various applications, including chemical testing in toxicology and gene screening. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Arezoo Khalili
- Department of Mechanical Engineering, York University, Toronto, Ontario, Canada
| | | | - Khaled Youssef
- Department of Mechanical Engineering, York University, Toronto, Ontario, Canada
| | - Georg R Zoidl
- Department of Biology, York University, Toronto, Ontario, Canada
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, Ontario, Canada
| |
Collapse
|
5
|
Subendran S, Wang YC, Lu YH, Chen CY. The evaluation of zebrafish cardiovascular and behavioral functions through microfluidics. Sci Rep 2021; 11:13801. [PMID: 34226579 PMCID: PMC8257654 DOI: 10.1038/s41598-021-93078-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 06/11/2021] [Indexed: 02/06/2023] Open
Abstract
This study proposed a new experimental approach for the vascular and phenotype evaluation of the non-anesthetized zebrafish with representative imaging orientations for heart, pectoral fin beating, and vasculature views by means of the designed microfluidic device through inducing the optomotor response and hydrodynamic pressure control. In order to provide the visual cues for better positioning of zebrafish, computer-animated moving grids were generated by an in-house control interface which was powered by the larval optomotor response, in conjunction with the pressure suction control. The presented platform provided a comprehensive evaluation of internal circulation and the linked external behaviors of zebrafish in response to the cardiovascular parameter changes. The insights from these imaging sections was extended to identify the linkage between the cardiac parameters and behavioral endpoints. In addition, selected chemicals such as ethanol and caffeine were employed for the treatment of zebrafish. The obtained findings can be applicable for future investigation in behavioral drug screening serving as the forefront in psychopharmacological and cognition research.
Collapse
Affiliation(s)
- Satishkumar Subendran
- Department of Mechanical Engineering, National Cheng Kung University, No. 1 University Road, Tainan, 701, Taiwan
| | - Yi-Chieh Wang
- Department of Mechanical Engineering, National Cheng Kung University, No. 1 University Road, Tainan, 701, Taiwan
| | - Yueh-Hsun Lu
- Department of Radiology, Shuang-Ho Hospital, Taipei Medical University, New Taipei City, 235, Taiwan
- Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
- Department of Radiology, National Yang-Ming University School of Medicine, Taipei, 112, Taiwan
| | - Chia-Yuan Chen
- Department of Mechanical Engineering, National Cheng Kung University, No. 1 University Road, Tainan, 701, Taiwan.
| |
Collapse
|
6
|
Edible additive effects on zebrafish cardiovascular functionality with hydrodynamic assessment. Sci Rep 2020; 10:16243. [PMID: 33004964 PMCID: PMC7530699 DOI: 10.1038/s41598-020-73455-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 08/19/2020] [Indexed: 01/17/2023] Open
Abstract
Food coloring is often used as a coloring agent in foods, medicines and cosmetics, and it was reported to have certain carcinogenic and mutagenic effects in living organisms. Investigation of physiological parameters using zebrafish is a promising methodology to understand disease biology and drug toxicity for various drug discovery on humans. Zebrafish (Danio rerio) is a well-acknowledged model organism with combining assets such as body transparency, small size, low cost of cultivation, and high genetic homology with humans and is used as a specimen tool for the in-vivo throughput screening approach. In addition, recent advances in microfluidics show a promising alternative for zebrafish manipulation in terms of drug administration and extensive imaging capability. This pilot work highlighted the design and development of a microfluidic detection platform for zebrafish larvae through investigating the effects of food coloring on cardiovascular functionality and pectoral fin swing ability. The zebrafish embryos were exposed to the Cochineal Red and Brilliant Blue FCF pigment solution in a concentration of (0.02‰, 0.2‰) cultured in the laboratory from the embryo stage to hatching and development until 9 days post fertilization (d.p.f.). In addition, zebrafish swimming behaviors in terms of pectoral fin beating towards the toxicity screening were further studied by visualizing the induced flow field. It was evidenced that Cochineal Red pigment at a concentration of 0.2‰ not only significantly affected the zebrafish pectoral fin swing behavior, but also significantly increased the heart rate of juvenile fish. The higher concentration of Brilliant Blue FCF pigment (0.2%) increased heart rate during early embryonic stages of zebrafish. However, zebrafish exposed to food coloring did not show any significant changes in cardiac output. The applications of this proposed platform can be further extended towards observing the neurobiological/hydrodynamic behaviors of zebrafish larvae for practical applications in drug tests.
Collapse
|
7
|
Khalili A, Peimani AR, Safarian N, Youssef K, Zoidl G, Rezai P. Phenotypic chemical and mutant screening of zebrafish larvae using an on-demand response to electric stimulation. Integr Biol (Camb) 2020; 11:373-383. [PMID: 31851358 DOI: 10.1093/intbio/zyz031] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2019] [Revised: 09/25/2019] [Accepted: 10/01/2019] [Indexed: 12/20/2022]
Abstract
Behavioral responses of zebrafish larvae to environmental cues are important functional readouts that should be evoked on-demand and studied phenotypically in behavioral, genetical and developmental investigations. Very recently, it was shown that zebrafish larvae execute a voluntary and oriented movement toward the positive electrode of an electric field along a microchannel. Phenotypic characterization of this response was not feasible due to larva's rapid movement along the channel. To overcome this challenge, a microfluidic device was introduced to partially immobilize the larva's head while leaving its mid-body and tail unrestrained in a chamber to image motor behaviors in response to electric stimulation, hence achieving quantitative phenotyping of the electrically evoked movement in zebrafish larvae. The effect of electric current on the tail-beat frequency and response duration of 5-7 days postfertilization zebrafish larvae was studied. Investigations were also performed on zebrafish exposed to neurotoxin 6-hydroxydopamine and larvae carrying a pannexin1a (panx1a) gene knockout, as a proof of principle applications to demonstrate on-demand movement behavior screening in chemical and mutant assays. We demonstrated for the first time that 6-hydroxydopamine leads to electric response impairment, levodopa treatment rescues the response and panx1a is involved in the electrically evoked movement of zebrafish larvae. We envision that our technique is broadly applicable as a screening tool to quantitatively examine zebrafish larvae's movements in response to physical and chemical stimulations in investigations of Parkinson's and other neurodegenerative diseases, and as a tool to combine recent advances in genome engineering of model organisms to uncover the biology of electric response.
Collapse
Affiliation(s)
- Arezoo Khalili
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| | - Amir Reza Peimani
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| | | | - Khaled Youssef
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| | - Georg Zoidl
- Department of Biology, York University, Toronto, ON, Canada
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| |
Collapse
|
8
|
Panigrahi B, Chen CY. Microfluidic retention of progressively motile zebrafish sperms. LAB ON A CHIP 2019; 19:4033-4042. [PMID: 31746882 DOI: 10.1039/c9lc00534j] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Genetic manipulation of zebrafish results in thousands of mutant strains and to efficiently preserve them for future use, zebrafish sperms have been cryopreserved in various cryopreservation centers. However, cryopreservation protocols are known to alter genetic entities. Therefore, there is an urgent need for an efficient method that can select morphologically superior and progressively motile zebrafish sperms after their activation for in vitro fertilization success. However, unlike those of other mammalian species, fish sperms do not take any physical or chemical cues to travel towards the egg. Their inertness towards any external cues makes the control of their orientation in a microfluidic environment difficult. In this aspect, a new microfluidic concept was demonstrated where PDMS baffles were inserted in the sidewalls to form microscale confinement creating a flow stagnation zone towards sperm retention. Two distinct microfluidic device designs were selected to evidence the improvement in sperm retention through the unique hydrodynamic feature provided by the microchannel design. Under similar flow conditions, 44% improvement was noticed for the device with a modified baffle design in terms of sperm retrieving efficiency. It was further noticed that with a flow tuning of 0.7 μL min-1, 80% of the total sperms swimming into the retention zones was retained within a specific time window. The present work further explains the significance of the hydrodynamic dependency of zebrafish sperm kinematics that paves the way for highly efficient spermatozoan manipulation.
Collapse
Affiliation(s)
- Bivas Panigrahi
- Department of Mechanical Engineering, National Cheng Kung University, No. 1 University Road, Tainan 701, Taiwan.
| | - Chia-Yuan Chen
- Department of Mechanical Engineering, National Cheng Kung University, No. 1 University Road, Tainan 701, Taiwan.
| |
Collapse
|
9
|
Panigrahi B, Chen CY. Microfluidic Transportation Control of Larval Zebrafish through Optomotor Regulations under a Pressure-Driven Flow. MICROMACHINES 2019; 10:mi10120880. [PMID: 31847405 PMCID: PMC6953065 DOI: 10.3390/mi10120880] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/05/2019] [Accepted: 12/05/2019] [Indexed: 01/19/2023]
Abstract
To perform zebrafish larvae-related experiments within a microfluidic environment, the larvae need to be anesthetized and subsequently transported into respective test sections through mechanical or manual means. However, anesthetization tends to affect larval sensory perceptions, hindering their natural behaviors. Taking into account that juvenile larvae move naturally within their environment by accessing visual as well as hydromechanical cues, this work proposes an experimental framework to transport nonanesthetized larvae within a microfluidic environment by harmonically tuning both of the aforementioned cues. To provide visual cues, computer-animated moving gratings were provided through an in-house-developed control interface that drove the larval optomotor response. In the meantime, to provide hydromechanical cues, the flow rate was tuned using a syringe pump that affected the zebrafish larvae’s lateral line movement. The results obtained (corresponding to different test conditions) suggest that the magnitude of both modalities plays a crucial role in larval transportation and orientation control. For instance, with a flow rate tuning of 0.1 mL/min along with grating parameters of 1 Hz temporal frequency, the average transportation time for larvae that were 5 days postfertilization was recorded at 1.29 ± 0.49 s, which was approximately three times faster than the transportation time required only in the presence of hydromechanical cues.
Collapse
|
10
|
Khalili A, Rezai P. Microfluidic devices for embryonic and larval zebrafish studies. Brief Funct Genomics 2019; 18:419-432. [DOI: 10.1093/bfgp/elz006] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 02/09/2019] [Accepted: 03/14/2019] [Indexed: 12/16/2022] Open
Abstract
Abstract
Zebrafish or Danio rerio is an established model organism for studying the genetic, neuronal and behavioral bases of diseases and for toxicology and drug screening. The embryonic and larval stages of zebrafish have been used extensively in fundamental and applied research due to advantages offered such as body transparency, small size, low cost of cultivation and high genetic homology with humans. However, the manual experimental methods used for handling and investigating this organism are limited due to their low throughput, labor intensiveness and inaccuracy in delivering external stimuli to the zebrafish while quantifying various neuronal and behavioral responses. Microfluidic and lab-on-a-chip devices have emerged as ideal technologies to overcome these challenges. In this review paper, the current microfluidic approaches for investigation of behavior and neurobiology of zebrafish at embryonic and larval stages will be reviewed. Our focus will be to provide an overview of the microfluidic methods used to manipulate (deliver and orient), immobilize and expose or inject zebrafish embryos or larvae, followed by quantification of their responses in terms of neuron activities and movement. We will also provide our opinion in terms of the direction that the field of zebrafish microfluidics is heading toward in the area of biomedical engineering.
Collapse
Affiliation(s)
- Arezoo Khalili
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| |
Collapse
|
11
|
Panigrahi B, Lu CH, Ghayal N, Chen CY. Sperm activation through orbital and self-axis revolutions using an artificial cilia embedded serpentine microfluidic platform. Sci Rep 2018; 8:4605. [PMID: 29545517 PMCID: PMC5854595 DOI: 10.1038/s41598-018-22563-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 02/23/2018] [Indexed: 11/10/2022] Open
Abstract
The zebrafish sperm activation profoundly depends upon the homogeneous mixing of the sperm cells with its diluent in a quick succession as it alters the cell's extracellular medium and initiates their motility. Manual stirring, the traditional method for zebrafish sperm activation is tedious, time-consuming, and has a poor outcome. In this aspect, an artificial cilia embedded serpentine microfluidic is designed through which hydrodynamic factors of the microfluidic environment can be precisely regulated to harness uniform mixing, hence ensuring a superior sperm activation. To quantify the sperm motility, computer assisted sperm analysis software (CASA) was used whereas to quantify the generated flow field, micro particle image velocimetry (μPIV) was used. With this proposed microfluidic, 74.4% of the zebrafish sperm were activated which is 20% higher than its currently existing manual measurements. The μPIV analysis demonstrates that the curvature of the microchannel induces an orbital rotation to the flow field along the length of the microchannel together with the artificial cilia actuation which instigates a local rotation to the flow field of the artificial cilia location. The collective rotation in the whole flow field induce vorticity that promotes the change in temporal dynamics of the sperm cells towards their activation.
Collapse
Affiliation(s)
- Bivas Panigrahi
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, 701, Taiwan
| | - Chang-Hung Lu
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, 701, Taiwan
| | - Neha Ghayal
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, 701, Taiwan
| | - Chia-Yuan Chen
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, 701, Taiwan.
| |
Collapse
|
12
|
Huang D, Li H, He Q, Yuan W, Chen Z, Yang H. Developmental Toxicity of Diethylnitrosamine in Zebrafish Embryos/Juveniles Related to Excessive Oxidative Stress. WATER, AIR, AND SOIL POLLUTION 2018; 229:81. [PMID: 29503482 PMCID: PMC5823957 DOI: 10.1007/s11270-018-3739-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Accepted: 02/07/2018] [Indexed: 05/18/2023]
Abstract
Diethylnitrosamine (DEN) is present in food, water, and daily supplies and is regarded as a toxicant of carcinogenicity. The developmental toxicity of DEN has been rarely reported as yet. In this study, zebrafish were exposed to different concentrations of DEN at 6 h post-fertilization (hpf) to access embryonic toxicity of the compound. The results show that DEN resulted in negative effects of hatching rate, heartbeat, body length, and spontaneous movement. Deformities, including notochord malformation, pericardium edema, embryonic membrane turbidity, tail hypoplasia, yolk sac deformity, and growth retardation, happened during exposure period. Moreover, production of reactive oxygen species (ROS) significantly increased after DEN treatment. Then, alterations of the expression level of oxidative stress-related genes were observed in our results. To our knowledge, this is the first study concerning the effect of DEN on zebrafish. And from the information of our research, we speculated that development toxicity of DEN should be related to the excessive oxidative stress.
Collapse
Affiliation(s)
- Danping Huang
- Guangdong Key Laboratory of Liver Disease Research, The Third Affiliated Hospital, Sun Yat-sen University, Tianhe Road No. 600, Guangzhou, 510000 China
| | - Hanmin Li
- Hubei Provincial Hospital of Traditional Chinese Medicine, Garden Hill No. 4 Wuchang District, Wuhan, 430061 China
- Hubei Province Academy of Traditional Chinese Medicine, No.856 Luoyu Road, Hongshan District, Wuhan, 430074 China
| | - Qidi He
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006 China
| | - Weiqu Yuan
- The fourth Clinical Medical College of Guangzhou University Chinese Med, Shen zhen, 518000 China
| | - Zuanguang Chen
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006 China
| | - Hongzhi Yang
- Guangdong Key Laboratory of Liver Disease Research, The Third Affiliated Hospital, Sun Yat-sen University, Tianhe Road No. 600, Guangzhou, 510000 China
| |
Collapse
|
13
|
Miniaturized Sensors and Actuators for Biological Studies on Small Model Organisms of Disease. ENERGY, ENVIRONMENT, AND SUSTAINABILITY 2018. [DOI: 10.1007/978-981-10-7751-7_9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
14
|
Mani K, Chang Chien TC, Panigrahi B, Chen CY. Manipulation of zebrafish's orientation using artificial cilia in a microchannel with actively adaptive wall design. Sci Rep 2016; 6:36385. [PMID: 27821862 PMCID: PMC5099576 DOI: 10.1038/srep36385] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Accepted: 10/12/2016] [Indexed: 12/15/2022] Open
Abstract
The zebrafish is a powerful genetic model organism especially in the biomedical chapter for new drug discovery and development. The genetic toolbox which this vertebrate possesses opens a new window to investigate the etiology of human diseases with a high degree genetic similarity. Still, the requirements of laborious and time-consuming of contemporary zebrafish processing assays limit the procedure in carrying out such genetic screen at high throughput. Here, a zebrafish control scheme was initiated which includes the design and validation of a microfluidic platform to significantly increase the throughput and performance of zebrafish larvae manipulation using the concept of artificial cilia actuation. A moving wall design was integrated into this microfluidic platform first time in literature to accommodate zebrafish inside the microchannel from 1 day post-fertilization (dpf) to 6 dpf and can be further extended to 9 dpf for axial orientation control in a rotational range between 0 to 25 degrees at the minimum step of 2-degree increment in a stepwise manner. This moving wall feature was performed through the deflection of shape memory alloy wire embedded inside the microchannel controlled by the electrical waveforms with high accuracy.
Collapse
Affiliation(s)
- Karthick Mani
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - Tsung-Chun Chang Chien
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - Bivas Panigrahi
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - Chia-Yuan Chen
- Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
15
|
Yang F, Gao C, Wang P, Zhang GJ, Chen Z. Fish-on-a-chip: microfluidics for zebrafish research. LAB ON A CHIP 2016; 16:1106-25. [PMID: 26923141 DOI: 10.1039/c6lc00044d] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
High-efficiency zebrafish (embryo) handling platforms are crucially needed to facilitate the deciphering of the increasingly expanding vertebrate-organism model values. However, the manipulation platforms for zebrafish are scarce and rely mainly on the conventional "static" microtiter plates or glass slides with rigid gel, which limits the dynamic, three-dimensional (3D), tissue/organ-oriented information acquisition from the intact larva with normal developmental dynamics. In addition, these routine platforms are not amenable to high-throughput handling of such swimming multicellular biological entities at the single-organism level and incapable of precisely controlling the growth microenvironment by delivering stimuli in a well-defined spatiotemporal fashion. Recently, microfluidics has been developed to address these technical challenges via tailor-engineered microscale structures or structured arrays, which integrate with or interface to functional components (e.g. imaging systems), allowing quantitative readouts of small objects (zebrafish larvae and embryos) under normal physiological conditions. Here, we critically review the recent progress on zebrafish manipulation, imaging and phenotype readouts of external stimuli using these microfluidic tools and discuss the challenges that confront these promising "fish-on-a-chip" technologies. We also provide an outlook on future potential trends in this field by combining with bionanoprobes and biosensors.
Collapse
Affiliation(s)
- Fan Yang
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China.
| | - Chuan Gao
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China.
| | - Ping Wang
- School of Basic Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China
| | - Guo-Jun Zhang
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 1 Huangjia Lake West Road, Wuhan 430065, China.
| | - Zuanguang Chen
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006, China
| |
Collapse
|
16
|
Lin X, Li VWT, Chen S, Chan CY, Cheng SH, Shi P. Autonomous system for cross-organ investigation of ethanol-induced acute response in behaving larval zebrafish. BIOMICROFLUIDICS 2016; 10:024123. [PMID: 27158291 PMCID: PMC4833730 DOI: 10.1063/1.4946013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Accepted: 03/30/2016] [Indexed: 06/05/2023]
Abstract
Ethanol is widely consumed and has been associated with various diseases in different organs. It is therefore important to study ethanol-induced responses in living organisms with the capability to address specific organs in an integrative manner. Here, we developed an autonomous system based on a series of microfluidic chips for cross-organ investigation of ethanol-induced acute response in behaving larval zebrafish. This system enabled high-throughput, gel-free, and anesthetic-free manipulation of larvae, and thus allowed real-time observation of behavioral responses, and associated physiological changes at cellular resolution within specific organs in response to acute ethanol stimuli, which would otherwise be impossible by using traditional methods for larva immobilization and orientation. Specifically, three types of chips ("motion," "lateral," and "dorsal"), based on a simple hydrodynamic design, were used to perform analysis in animal behavior, cardiac, and brain physiology, respectively. We found that ethanol affected larval zebrafish in a dose-dependent manner. The motor function of different body parts was significantly modulated by ethanol treatment, especially at a high dose of 3%. These behavioral changes were temporally associated with a slow-down of heart-beating and a stereotyped activation of certain brain regions. As we demonstrated in this proof-of-concept study, this versatile Fish-on-Chip platform could potentially be adopted for systematic cross-organ investigations involving chemical or genetic manipulations in zebrafish model.
Collapse
Affiliation(s)
- Xudong Lin
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave., Kowloon 999077, Hong Kong, China
| | - Vincent W T Li
- Department of Biomedical Science, City University of Hong Kong, 83 Tat Chee Ave., Kowloon 999077, Hong Kong, China
| | - Siya Chen
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave., Kowloon 999077, Hong Kong, China
| | - Chung-Yuen Chan
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave., Kowloon 999077, Hong Kong, China
| | | | | |
Collapse
|
17
|
Lin X, Wang S, Yu X, Liu Z, Wang F, Li WT, Cheng SH, Dai Q, Shi P. High-throughput mapping of brain-wide activity in awake and drug-responsive vertebrates. LAB ON A CHIP 2015; 15:680-9. [PMID: 25406521 DOI: 10.1039/c4lc01186d] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The reconstruction of neural activity across complete neural circuits, or brain activity mapping, has great potential in both fundamental and translational neuroscience research. Larval zebrafish, a vertebrate model, has recently been demonstrated to be amenable to whole brain activity mapping in behaving animals. Here we demonstrate a microfluidic array system ("Fish-Trap") that enables high-throughput mapping of brain-wide activity in awake larval zebrafish. Unlike the commonly practiced larva-processing methods using a rigid gel or a capillary tube, which are laborious and time-consuming, the hydrodynamic design of our microfluidic chip allows automatic, gel-free, and anesthetic-free processing of tens of larvae for microscopic imaging with single-cell resolution. Notably, this system provides the capability to directly couple pharmaceutical stimuli with real-time recording of neural activity in a large number of animals, and the local and global effects of pharmacoactive drugs on the nervous system can be directly visualized and evaluated by analyzing drug-induced functional perturbation within or across different brain regions. Using this technology, we tested a set of neurotoxin peptides and obtained new insights into how to exploit neurotoxin derivatives as therapeutic agents. The novel and versatile "Fish-Trap" technology can be readily unitized to study other stimulus (optical, acoustic, or physical) associated functional brain circuits using similar experimental strategies.
Collapse
Affiliation(s)
- Xudong Lin
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China 999077.
| | | | | | | | | | | | | | | | | |
Collapse
|