1
|
Gao H, Wan X, Xiao W, Yang Y, Lu J, Wu S, Xu L, Wang S. Heterogeneous Organohydrogel Toward Automated and Interference-Free Gradient Feeding of Drugs in Cell Screening. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2401720. [PMID: 39167495 PMCID: PMC11516076 DOI: 10.1002/advs.202401720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Revised: 06/26/2024] [Indexed: 08/23/2024]
Abstract
Cell-based microarrays are widely used in the fields of drug discovery and toxicology. Precise gradient generation and automated drug feeding are essential for high-throughput screening of live cells in tiny droplets. However, most existing technologies either require sophisticated robotic equipment or cause mechanical/physiological interference with cells. Here, a heterogeneous organohydrogel is presented for automated gradient drug feeding, while ensuring minimal interference with cells. The heterogeneous organohydrogel comprises three crucial components. The bottom surface can automatically generate gradients functioning as a gradient generator, the organohydrogel bulk allows unidirectional transport of drugs without backflow, and the top surface with hydrophilic arrays can firmly anchor the cell-based droplet array to evaluate the concentration-dependent bioeffects of drugs accurately. Such a unique structure enables universal screening of different cell types and drugs dissolved in different solvents, requiring neither additional accessories nor arduous drug functionalization. The heterogeneous organohydrogel with unprecedented automation and non-interference possesses the enormous potential to be a next-generation platform for drug screening.
Collapse
Affiliation(s)
- Hongxiao Gao
- Beijing Key Laboratory for Bioengineering and Sensing TechnologySchool of Chemistry and Biological EngineeringUniversity of Science and Technology BeijingBeijing100083P. R. China
| | - Xizi Wan
- CAS Key Laboratory of Bio‐inspired Materials and Interfacial ScienceTechnical Institute of Physics and ChemistryChinese Academy of SciencesBeijing100190P. R. China
- University of Chinese Academy of SciencesBeijing100049P. R. China
| | - Wu‐Yi Xiao
- CAS Key Laboratory of Bio‐inspired Materials and Interfacial ScienceTechnical Institute of Physics and ChemistryChinese Academy of SciencesBeijing100190P. R. China
- University of Chinese Academy of SciencesBeijing100049P. R. China
| | - Yuemeng Yang
- Beijing Key Laboratory for Bioengineering and Sensing TechnologySchool of Chemistry and Biological EngineeringUniversity of Science and Technology BeijingBeijing100083P. R. China
| | - Jingwei Lu
- Beijing Key Laboratory for Bioengineering and Sensing TechnologySchool of Chemistry and Biological EngineeringUniversity of Science and Technology BeijingBeijing100083P. R. China
| | - Shihao Wu
- Beijing Key Laboratory for Bioengineering and Sensing TechnologySchool of Chemistry and Biological EngineeringUniversity of Science and Technology BeijingBeijing100083P. R. China
| | - Li‐Ping Xu
- Beijing Key Laboratory for Bioengineering and Sensing TechnologySchool of Chemistry and Biological EngineeringUniversity of Science and Technology BeijingBeijing100083P. R. China
| | - Shutao Wang
- CAS Key Laboratory of Bio‐inspired Materials and Interfacial ScienceTechnical Institute of Physics and ChemistryChinese Academy of SciencesBeijing100190P. R. China
- University of Chinese Academy of SciencesBeijing100049P. R. China
- Suzhou Institute for Advanced ResearchUniversity of Science and Technology of ChinaSuzhou215123P. R. China
| |
Collapse
|
2
|
Song Y, Wang L, Xu T, Zhang G, Zhang X. Emerging open-channel droplet arrays for biosensing. Natl Sci Rev 2023; 10:nwad106. [PMID: 38027246 PMCID: PMC10662666 DOI: 10.1093/nsr/nwad106] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 11/23/2022] [Accepted: 12/07/2022] [Indexed: 12/01/2023] Open
Abstract
Open-channel droplet arrays have attracted much attention in the fields of biochemical analysis, biofluid monitoring, biomarker recognition and cell interactions, as they have advantages with regard to miniaturization, parallelization, high-throughput, simplicity and accessibility. Such droplet arrays not only improve the sensitivity and accuracy of a biosensor, but also do not require sophisticated equipment or tedious processes, showing great potential in next-generation miniaturized sensing platforms. This review summarizes typical examples of open-channel microdroplet arrays and focuses on diversified biosensing integrated with multiple signal-output approaches (fluorescence, colorimetric, surface-enhanced Raman scattering (SERS), electrochemical, etc.). The limitations and development prospects of open-channel droplet arrays in biosensing are also discussed with regard to the increasing demand for biosensors.
Collapse
Affiliation(s)
- Yongchao Song
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
- Intelligent Wearable Engineering Research Center of Qingdao, Research Center for Intelligent and Wearable Technology, College of Textiles and Clothing, State Key Laboratory of Bio-Fibers and Eco-Textiles, Qingdao University, Qingdao 266071, China
| | - Lirong Wang
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| | - Tailin Xu
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| | - Guangyao Zhang
- Intelligent Wearable Engineering Research Center of Qingdao, Research Center for Intelligent and Wearable Technology, College of Textiles and Clothing, State Key Laboratory of Bio-Fibers and Eco-Textiles, Qingdao University, Qingdao 266071, China
| | - Xueji Zhang
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
3
|
Xie C, Sun B, Liu R, Qu K, Zhang W, Weng Z, Wang Z. Facile fabrication of micropattern surfaces with controlled wettability on PDMS-modified fiber membranes for cell patterning. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1820-1826. [PMID: 35481818 DOI: 10.1039/d2ay00209d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Various cell culture substrates have been developed for cell patterning to control cell distributions and orientations in tissue engineering, drug screening and regenerative medicine. In this study, a preparation method of modified fiber membranes was applied in the field of cell patterning, and the obtained fiber membranes guided the cell distributions and orientations flexibly. The aligned electrospinning fiber membranes were dip-coated with polydimethylsiloxane (PDMS) to improve the stability of wettability, and then it was treated with oxygen plasma with a photomask to obtain a hydrophilic-hydrophobic surface micropattern. The morphologies, wettabilities and chemical structures of the membranes were analyzed by using a scanning electron microscope (SEM), drop shape analysis instrument, energy dispersive spectrometer (EDS) and Fourier transform infrared (FTIR) spectrometer. The L929 cells were cultured on the obtained membranes to observe the controlled cell distributions and orientations by using a SEM and fluorescence microscope. The results indicate that the treated membranes have the ability to control both cell distributions and orientations simultaneously. This method offers a novel approach to develop cell culture substrates for cell patterning in tissue engineering.
Collapse
Affiliation(s)
- Chenchen Xie
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
| | - Baishun Sun
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
| | - Ri Liu
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
- Zhongshan Institute, Changchun University of Science and Technology, Zhongshan 528437, China
| | - Kaige Qu
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
| | - Wenxiao Zhang
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
| | - Zhankun Weng
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
- Zhongshan Institute, Changchun University of Science and Technology, Zhongshan 528437, China
| | - Zuobin Wang
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China
- Zhongshan Institute, Changchun University of Science and Technology, Zhongshan 528437, China
- JR3CN, IRAC, University of Bedfordshire, Luton LU1 3JU, UK
| |
Collapse
|
4
|
Xie T, Zhang Q, Zhang W, Feng S, Lin JM. Inkjet-Patterned Microdroplets as Individual Microenvironments for Adherent Single Cell Culture. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2107992. [PMID: 35362237 DOI: 10.1002/smll.202107992] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 02/26/2022] [Indexed: 06/14/2023]
Abstract
Adhesion of single cells is the foundation of manifold cellular behaviors and life processes. However, investigating the function of a specific cell is still challenging due to deficiency of adhesion or interference from surrounding cells. Herein, an open microfluidic system is reported for culturing adherent single cells, implemented by a micrometer-scale droplet matrix on an inkjet-printed polylysine template. The target cells are isolated from any cell from other droplets, and their adhesion strength is determined to be comparable to conventional petri dishes via an in-situ investigation with a microfluidic extractor. On this proposed platform, isolated single cells are observed to display an entirely distinct spreading behavior featuring total absence of elongation, indicating drastic cell behavior change from their "singleness." This system has high versatility and compatibility for various assaying methods, assuring a promising potential in detailed single cell behavior and cell heterogeneity studies.
Collapse
Affiliation(s)
- Tianze Xie
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology (Ministry of Education), Tsinghua University, Beijing, 100084, P. R. China
| | - Qiang Zhang
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology (Ministry of Education), Tsinghua University, Beijing, 100084, P. R. China
| | - Weifei Zhang
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, N 3rd Ring Road E 18, Beijing, 100029, P. R. China
| | - Shuo Feng
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology (Ministry of Education), Tsinghua University, Beijing, 100084, P. R. China
| | - Jin-Ming Lin
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology (Ministry of Education), Tsinghua University, Beijing, 100084, P. R. China
| |
Collapse
|
5
|
Liu D, Sun M, Zhang J, Hu R, Fu W, Xuanyuan T, Liu W. Single-cell droplet microfluidics for biomedical applications. Analyst 2022; 147:2294-2316. [DOI: 10.1039/d1an02321g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
This review focuses on the recent advances in the fundamentals of single-cell droplet microfluidics and its applications in biomedicine, providing insights into design and establishment of single-cell microsystems and their further performance.
Collapse
Affiliation(s)
- Dan Liu
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| | - Meilin Sun
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| | - Jinwei Zhang
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| | - Rui Hu
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| | - Wenzhu Fu
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| | - Tingting Xuanyuan
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| | - Wenming Liu
- Departments of Biomedical Engineering and Pathology, School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
| |
Collapse
|
6
|
Wang Y, Wang G, He M, Liu F, Han M, Tang T, Luo S. Multifunctional Laser-Induced Graphene Papers with Combined Defocusing and Grafting Processes for Patternable and Continuously Tunable Wettability from Superlyophilicity to Superlyophobicity. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2103322. [PMID: 34523240 DOI: 10.1002/smll.202103322] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 07/21/2021] [Indexed: 06/13/2023]
Abstract
Functional surfaces with tunable and patternable wettability have attracted significant research interests because of remarkable advantages in biomedicine, environmental, and energy storage applications. Based on combined defocusing and grafting strategy for processing laser-induced graphene papers (LIGPs) with variable surface roughness (58.18-6.08 µm) and F content (0-25.9%), their wettability can be tuned continuously from superlyophilicity (contact angle CA ≈ 0° ) to superlyophobicity (CA > 150° ), for various liquids with a wide range of surface tensions from 27.5 to 72.8 mN m-1 . In addition to reaching multiple wetting characteristics including amphiphilic, amphiphobic, and hydrophobic-oleophilic states, three designable processes are further developed for achieving LIGPs with various wetting patterns, including hydrophilic arrays or channels, hydrophobic-to-hydrophilic gradients, and Janus. Activated by the customly designed structures and properties, multifunctional and multi-scenario applications are successfully attempted, including 2D-/3D- directional cell cultivation, water transportation diode, self-triggered liquid transfer & collection, etc.
Collapse
Affiliation(s)
- Yanan Wang
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| | - Guantao Wang
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| | - Meihong He
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| | - Fu Liu
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| | - Mingguang Han
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| | - Tan Tang
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| | - Sida Luo
- School of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing, 100191, China
| |
Collapse
|
7
|
Liu Y, Sun L, Zhang H, Shang L, Zhao Y. Microfluidics for Drug Development: From Synthesis to Evaluation. Chem Rev 2021; 121:7468-7529. [PMID: 34024093 DOI: 10.1021/acs.chemrev.0c01289] [Citation(s) in RCA: 81] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Drug development is a long process whose main content includes drug synthesis, drug delivery, and drug evaluation. Compared with conventional drug development procedures, microfluidics has emerged as a revolutionary technology in that it offers a miniaturized and highly controllable environment for bio(chemical) reactions to take place. It is also compatible with analytical strategies to implement integrated and high-throughput screening and evaluations. In this review, we provide a comprehensive summary of the entire microfluidics-based drug development system, from drug synthesis to drug evaluation. The challenges in the current status and the prospects for future development are also discussed. We believe that this review will promote communications throughout diversified scientific and engineering communities that will continue contributing to this burgeoning field.
Collapse
Affiliation(s)
- Yuxiao Liu
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Lingyu Sun
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Hui Zhang
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Luoran Shang
- Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics, the International Co-laboratory of Medical Epigenetics and Metabolism, Ministry of Science and Technology, Institutes of Biomedical Sciences, Fudan University, Shanghai, China
| | - Yuanjin Zhao
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|