1
|
Johnson MD, Tingay DG, Perkins EJ, Sett A, Devsam B, Douglas E, Charlton JK, Wildenhain P, Rumpel J, Wagner M, Nadkarni V, Johnston L, Herrick HM, Hartman T, Glass K, Jung P, DeMeo SD, Shay R, Kim JH, Unrau J, Moussa A, Nishisaki A, Foglia EE. Factors that impact second attempt success for neonatal intubation following first attempt failure: a report from the National Emergency Airway Registry for Neonates. Arch Dis Child Fetal Neonatal Ed 2024; 109:609-615. [PMID: 38418208 PMCID: PMC11349927 DOI: 10.1136/archdischild-2023-326501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 02/21/2024] [Indexed: 03/01/2024]
Abstract
OBJECTIVE To determine the factors associated with second attempt success and the risk of adverse events following a failed first attempt at neonatal tracheal intubation. DESIGN Retrospective analysis of prospectively collected data on intubations performed in the neonatal intensive care unit (NICU) and delivery room from the National Emergency Airway Registry for Neonates (NEAR4NEOS). SETTING Eighteen academic NICUs in NEAR4NEOS. PATIENTS Neonates requiring two or more attempts at intubation between October 2014 and December 2021. MAIN OUTCOME MEASURES The primary outcome was successful intubation on the second attempt, with severe tracheal intubation-associated events (TIAEs) or severe desaturation (≥20% decline in oxygen saturation) being secondary outcomes. Multivariate regression examined the associations between these outcomes and patient characteristics and changes in intubation practice. RESULTS 5805 of 13 126 (44%) encounters required two or more intubation attempts, with 3156 (54%) successful on the second attempt. Second attempt success was more likely with changes in any of the following: intubator (OR 1.80, 95% CI 1.56 to 2.07), stylet use (OR 1.65, 95% CI 1.36 to 2.01) or endotracheal tube (ETT) size (OR 2.11, 95% CI 1.74 to 2.56). Changes in stylet use were associated with a reduced chance of severe desaturation (OR 0.74, 95% CI 0.61 to 0.90), but changes in intubator, laryngoscope type or ETT size were not; no changes in intubator or equipment were associated with severe TIAEs. CONCLUSIONS Successful neonatal intubation on a second attempt was more likely with a change in intubator, stylet use or ETT size.
Collapse
Affiliation(s)
- Mitchell David Johnson
- Neonatal Medicine, The Royal Children's Hospital Melbourne, Parkville, Victoria, Australia
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - David Gerald Tingay
- Neonatal Medicine, The Royal Children's Hospital Melbourne, Parkville, Victoria, Australia
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - Elizabeth J Perkins
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - Arun Sett
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Victoria, Australia
- Newborn Services, Western Health, St Albans, Victoria, Australia
| | - Bianca Devsam
- Neonatal Medicine, The Royal Children's Hospital Melbourne, Parkville, Victoria, Australia
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - Ellen Douglas
- Neonatal Research, Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - Julia K Charlton
- Department of Paediatrics, The University of Melbourne, Melbourne, Victoria, Australia
- Division of Neonatology, British Columbia Women's Hospital and Health Centre, Vancouver, British Columbia, Canada
| | - Paul Wildenhain
- The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Jennifer Rumpel
- Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Michael Wagner
- Division of Neonatology, Pediatric Intensive Care and Neuropediatrics, Department of Pediatrics, Medical University Vienna, Vienna, Austria
| | - Vinay Nadkarni
- Department of Anesthesiology, Critical Care, and Pediatrics, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Lindsay Johnston
- Department of Pediatrics, Yale University, New Haven, Connecticut, USA
| | - Heidi M Herrick
- Division of Neonatology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Tyler Hartman
- Department of Pediatrics, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire, USA
| | - Kristen Glass
- Department of Pediatrics, Penn State Health Children's Hospital/Penn State College of Medicine, Hershey, Pennsylvania, USA
| | - Philipp Jung
- Department of Pediatrics, University Hospital Schleswig-Holstein, Luebeck, Germany
| | - Stephen D DeMeo
- Division of Neonatology, WakeMed Health and Hospitals, Raleigh, North Carolina, USA
| | - Rebecca Shay
- Department of Pediatrics, Division of Neonatology, University of Colorado, Aurora, Colorado, USA
| | - Jae H Kim
- Perinatal Institute, Department of Pediatrics, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Jennifer Unrau
- Newborn Critical Care, Alberta Children's Hospital, Calgary, Alberta, Canada
| | - Ahmed Moussa
- Division of Neonatology, Department of Pediatrics, Centre Hospitalier Universitaire Sainte-Justine, Montreal, Quebec, Canada
- CHU Sainte-Justine Research Centre, Université de Montréal, Montreal, Quebec, Canada
| | - Akira Nishisaki
- Department of Anesthesiology and Critical Care Medicine, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Elizabeth E Foglia
- Division of Neonatology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| |
Collapse
|
2
|
Ljungqvist HE, Nurmi JO. Reasons behind failed prehospital intubation attempts while combining C-MAC videolaryngoscope and Frova introducer. Acta Anaesthesiol Scand 2022; 66:132-140. [PMID: 34582041 DOI: 10.1111/aas.13985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 08/11/2021] [Accepted: 09/04/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND High first-pass success rate is achieved with the routine use of C-MAC videolaryngoscope and Frova introducer. We aim to identify potential reasons and subgroups associated with failed intubation attempts, analyse actions taken after them and study possible complications. METHODS We conducted a retrospective observational study of adult intubated patients at a single helicopter emergency medical service unit in southern Finland between 2016 and 2018. We collected data on patient characteristics, reasons for failed attempts, complications and follow-up measures from a national helicopter emergency medical service database and from prehospital patient records. RESULTS 1011 tracheal intubations were attempted. First attempt was successful in 994 cases (FPS 994/1011, 98.3%), 15 needed a second or third attempt and two a surgical airway (non-FPS 17/1011, 1.7%, 95% CI 1.0-2.7). The failed first attempt group had heterogenous characteristics. The most common cause for a failed first attempt was obstruction of the airway by vomit, food, mucus or blood (10/13, 76%). After the failed first attempt, there were six cases (6/14, 43%) of deviation from the protocol and the most frequent complications were five cases (5/17, 29%) of hypoxia and four cases (4/17, 24%) of hypotension. CONCLUSIONS When a protocol combining the C-MAC videolaryngoscope and Frova introducer is used, the most common reason for a failed first attempt is an airway blocked by gastric content, blood or mucus. These findings highlight the importance of effective airway decontamination methods and questions the appropriateness of anatomically focused pre-intubation assessment tools when such protocol is used.
Collapse
Affiliation(s)
| | - Jouni O. Nurmi
- University of Helsinki Helsinki Finland
- Emergency Medicine and Services Helsinki University Hospital Helsinki Finland
| |
Collapse
|