1
|
Tang Y, Huang S, Xu J, Ouyang G, Liu Y. PLGA-based nanofibers with a biomimetic polynoradrenaline sheath for rapid in vivo sampling of tetrodotoxin and sulfonamides in pufferfish. J Mater Chem B 2018; 6:3655-3664. [DOI: 10.1039/c8tb00757h] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
PLGA nanofibers with PNA sheath modification achieve enhanced extraction performance and antibiofouling capacity for in vivo sampling in pufferfish.
Collapse
Affiliation(s)
- Yijia Tang
- Department of Food Science and Technology
- School of Agriculture and Biology
- Shanghai Jiao Tong University
- Shanghai 200240
- China
| | - Siming Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry
- School of Chemistry
- Sun Yat-sen University
- Guangzhou
- China
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry
- School of Chemistry
- Sun Yat-sen University
- Guangzhou
- China
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry
- School of Chemistry
- Sun Yat-sen University
- Guangzhou
- China
| | - Yuan Liu
- Department of Food Science and Technology
- School of Agriculture and Biology
- Shanghai Jiao Tong University
- Shanghai 200240
- China
| |
Collapse
|
2
|
Gionfriddo E, Boyacı E, Pawliszyn J. New Generation of Solid-Phase Microextraction Coatings for Complementary Separation Approaches: A Step toward Comprehensive Metabolomics and Multiresidue Analyses in Complex Matrices. Anal Chem 2017; 89:4046-4054. [DOI: 10.1021/acs.analchem.6b04690] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Emanuela Gionfriddo
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Ezel Boyacı
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
3
|
Zhou Y, Wang P, Xiong J, Yue H, He Y, Ouyang H, Wang L, Fu Z. A label-free strategy for measuring the affinity between monoclonal antibody and hapten using microdialysis sampling combined with chemiluminescent detection. Biosens Bioelectron 2017; 87:404-409. [DOI: 10.1016/j.bios.2016.08.068] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Revised: 08/14/2016] [Accepted: 08/19/2016] [Indexed: 11/26/2022]
|
4
|
Goryński K, Goryńska P, Górska A, Harężlak T, Jaroch A, Jaroch K, Lendor S, Skobowiat C, Bojko B. SPME as a promising tool in translational medicine and drug discovery: From bench to bedside. J Pharm Biomed Anal 2016; 130:55-67. [DOI: 10.1016/j.jpba.2016.05.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2016] [Revised: 05/03/2016] [Accepted: 05/04/2016] [Indexed: 01/11/2023]
|
5
|
Ocaña-González JA, Fernández-Torres R, Bello-López MÁ, Ramos-Payán M. New developments in microextraction techniques in bioanalysis. A review. Anal Chim Acta 2016; 905:8-23. [DOI: 10.1016/j.aca.2015.10.041] [Citation(s) in RCA: 128] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 10/08/2015] [Accepted: 10/28/2015] [Indexed: 12/21/2022]
|
6
|
Souza-Silva ÉA, Reyes-Garcés N, Gómez-Ríos GA, Boyacı E, Bojko B, Pawliszyn J. A critical review of the state of the art of solid-phase microextraction of complex matrices III. Bioanalytical and clinical applications. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.04.017] [Citation(s) in RCA: 180] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
7
|
Mousavi F, Bojko B, Pawliszyn J. Development of high throughput 96-blade solid phase microextraction-liquid chromatrography-mass spectrometry protocol for metabolomics. Anal Chim Acta 2015; 892:95-104. [PMID: 26388479 DOI: 10.1016/j.aca.2015.08.016] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2015] [Revised: 07/28/2015] [Accepted: 08/08/2015] [Indexed: 12/15/2022]
Abstract
In metabolomics, the workflow for quantitative and comprehensive metabolic mapping of cellular metabolites can be a very challenging undertaking. Sampling and sample preparation play a significant role in untargeted analysis, as they may affect the composition of the analyzed metabolome. In the current work, different solid phase microextraction (SPME) coating chemistries were developed and applied to provide simultaneous extraction of a wide range of both hydrophobic and hydrophilic cellular metabolites produced by a model organism, Escherichia coli. Three different LC-MS methods were also evaluated for analysis of extracted metabolites. Finally, over 200 cellular metabolites were separated and detected with widely varying hydrophobicities ranging within -7 < log P < 15, including amino acids, peptides, nucleotides, carbohydrates, polycarboxylic acids, vitamins, phosphorylated compounds, and lipids such as hydrophobic phospholipids, prenol lipids, and fatty acids at the stationary phase of the E. coli life cycle using the developed 96-blade SPME-LC-MS method.
Collapse
Affiliation(s)
- Fatemeh Mousavi
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Barbara Bojko
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
8
|
Boyacı E, Rodríguez-Lafuente Á, Gorynski K, Mirnaghi F, Souza-Silva ÉA, Hein D, Pawliszyn J. Sample preparation with solid phase microextraction and exhaustive extraction approaches: Comparison for challenging cases. Anal Chim Acta 2014; 873:14-30. [PMID: 25911426 DOI: 10.1016/j.aca.2014.12.051] [Citation(s) in RCA: 131] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2014] [Revised: 12/22/2014] [Accepted: 12/27/2014] [Indexed: 10/24/2022]
Abstract
In chemical analysis, sample preparation is frequently considered the bottleneck of the entire analytical method. The success of the final method strongly depends on understanding the entire process of analysis of a particular type of analyte in a sample, namely: the physicochemical properties of the analytes (solubility, volatility, polarity etc.), the environmental conditions, and the matrix components of the sample. Various sample preparation strategies have been developed based on exhaustive or non-exhaustive extraction of analytes from matrices. Undoubtedly, amongst all sample preparation approaches, liquid extraction, including liquid-liquid (LLE) and solid phase extraction (SPE), are the most well-known, widely used, and commonly accepted methods by many international organizations and accredited laboratories. Both methods are well documented and there are many well defined procedures, which make them, at first sight, the methods of choice. However, many challenging tasks, such as complex matrix applications, on-site and in vivo applications, and determination of matrix-bound and free concentrations of analytes, are not easily attainable with these classical approaches for sample preparation. In the last two decades, the introduction of solid phase microextraction (SPME) has brought significant progress in the sample preparation area by facilitating on-site and in vivo applications, time weighted average (TWA) and instantaneous concentration determinations. Recently introduced matrix compatible coatings for SPME facilitate direct extraction from complex matrices and fill the gap in direct sampling from challenging matrices. Following introduction of SPME, numerous other microextraction approaches evolved to address limitations of the above mentioned techniques. There is not a single method that can be considered as a universal solution for sample preparation. This review aims to show the main advantages and limitations of the above mentioned sample preparation approaches and the applicability and capability of each technique for challenging cases such as complex matrices, on-site applications and automation.
Collapse
Affiliation(s)
- Ezel Boyacı
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Ángel Rodríguez-Lafuente
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Krzysztof Gorynski
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Department of Pharmacodynamics and Molecular Pharmacology, Collegium Medicum in Bydgoszcz Nicolaus Copernicus University in Torun, Jurasza 2, 85-089 Bydgoszcz, Poland
| | - Fatemeh Mirnaghi
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Emergency Science and Technology Section, Environment Canada, 335 River Road, Ottawa, Ontario K1A 0H3, Canada
| | - Érica A Souza-Silva
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Dietmar Hein
- Professional Analytical System (PAS) Technology, Magdala, Germany
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
9
|
Challenges of analyzing different classes of metabolites by a single analytical method. Bioanalysis 2014; 6:3393-416. [DOI: 10.4155/bio.14.236] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Complex biological samples include thousands of metabolites that range widely in both physiochemical properties and concentration. Simultaneously analyzing metabolites with different properties using a single analytical method is very challenging. The analytical process for metabolites comprises multiple steps including sampling, quenching, sample preparation, separation and detection. Each step can have a significant effect on the reliability and precision of ultimate analytic results. The aim of review is a discussion of considerations and challenges for the simultaneous analysis of metabolites using LC– and GC–MS systems. The review discusses available methodology for each analytical step, and presents the limitations and advantages of each method for the large-scale targeted metabolomics analysis of human and animal biological samples.
Collapse
|
10
|
Gómez-Ríos GA, Pawliszyn J. Development of Coated Blade Spray Ionization Mass Spectrometry for the Quantitation of Target Analytes Present in Complex Matrices. Angew Chem Int Ed Engl 2014. [DOI: 10.1002/ange.201407057] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Gómez-Ríos GA, Pawliszyn J. Development of coated blade spray ionization mass spectrometry for the quantitation of target analytes present in complex matrices. Angew Chem Int Ed Engl 2014; 53:14503-7. [PMID: 25384839 DOI: 10.1002/anie.201407057] [Citation(s) in RCA: 162] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2014] [Revised: 10/21/2014] [Indexed: 01/09/2023]
Abstract
Coated blade spray (CBS) is a technology based on solid-phase microextraction (SPME) that has been designed for the quick extraction/cleanup of analytes from complex matrices and direct desorption/ionization under ambient mass spectrometry conditions. The entire analytical process can be completed in less than 3 min and enables limits of quantitation in the low picogram-per-milliliter region to be reached.
Collapse
Affiliation(s)
- German Augusto Gómez-Ríos
- Department of Chemistry, University of Waterloo, 200 University Avenue, Waterloo, N2L 3G1 (Canada) http://spme.uwaterloo.ca
| | | |
Collapse
|
12
|
Abstract
This article reviews the solid-phase microextraction technique and its potential to revolutionize bioanalysis in terms of combining sampling, sample preparation and extraction in one step with no blood withdrawal. Possible hurdles facing the technology when implemented in a pharmaceutical setting will be covered and the author will provide an outlook on the future of solid-phase microextraction as a novel microsampling technique for bioanalysis.
Collapse
|
13
|
Mirnaghi FS, Goryński K, Rodriguez-Lafuente A, Boyacı E, Bojko B, Pawliszyn J. Microextraction versus exhaustive extraction approaches for simultaneous analysis of compounds in wide range of polarity. J Chromatogr A 2013; 1316:37-43. [DOI: 10.1016/j.chroma.2013.09.084] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Revised: 09/25/2013] [Accepted: 09/27/2013] [Indexed: 11/24/2022]
|
14
|
Cudjoe E, Bojko B, de Lannoy I, Saldivia V, Pawliszyn J. Solid-Phase Microextraction: A Complementary In Vivo Sampling Method to Microdialysis. Angew Chem Int Ed Engl 2013. [DOI: 10.1002/ange.201304538] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
15
|
Cudjoe E, Bojko B, de Lannoy I, Saldivia V, Pawliszyn J. Solid-Phase Microextraction: A Complementary In Vivo Sampling Method to Microdialysis. Angew Chem Int Ed Engl 2013; 52:12124-6. [DOI: 10.1002/anie.201304538] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2013] [Revised: 07/29/2013] [Indexed: 11/11/2022]
|
16
|
Metabolic profiling of plasma from cardiac surgical patients concurrently administered with tranexamic acid: DI-SPME-LC-MS analysis. J Pharm Anal 2013; 4:6-13. [PMID: 29403864 PMCID: PMC5761052 DOI: 10.1016/j.jpha.2013.03.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Accepted: 03/14/2013] [Indexed: 11/24/2022] Open
Abstract
A metabolic profile of plasma samples from patients undergoing heart surgery with the use of cardiopulmonary bypass (CPB) and concurrent administration of tranexamic acid was determined. Direct immersion solid phase microextraction (DI-SPME), a new sampling and sample preparation tool for metabolomics, was used in this study for the first time to investigate clinical samples. The results showed alteration of diverse compounds involved in different biochemical pathways. The most significant contribution in changes induced by surgery and applied pharmacotherapy was noticed in metabolic profile of lysophospholipids, triacylglycerols, mediators of platelet aggregation, and linoleic acid metabolites. Two cases of individual response to treatment were also reported.
Collapse
|
17
|
Mirnaghi FS, Hein D, Pawliszyn J. Thin-Film Microextraction Coupled with Mass Spectrometry and Liquid Chromatography–Mass Spectrometry. Chromatographia 2013. [DOI: 10.1007/s10337-013-2443-5] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
18
|
Chemical Institute of Canada and Canadian Society for Chemistry Awards. Angew Chem Int Ed Engl 2013. [DOI: 10.1002/anie.201209647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
19
|
Preise des Chemical Institute of Canada und der Canadian Society for Chemistry. Angew Chem Int Ed Engl 2013. [DOI: 10.1002/ange.201209647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
20
|
Abstract
Conventional in vitro or ex vivo bioanalytical quantitative sample preparation methods for the determination of compounds in biological tissues are often coupled with challenges in obtaining an assay representative of the system of interest. The rising interest in in vivo microsampling bioanalytical methods is due to the unique advantages they offer over their in vitro counterparts. In vivo solid-phase microextraction (SPME), a diffusion-based microsampling tool, has been successfully applied in recent studies to various biological systems. This review presents recent trends in tissue bioanalysis using in vivo SPME as a sample preparation tool. Efforts were made to discuss the various bioapplications of the method while highlighting possible strategies for improved sensitivity where needed. In vivo SPME devices currently employed for the various applications have also been described. In addition, we highlight selectivity of a new class of biocompatible coatings that can potentially improve the coverage of metabolites for untargeted metabolomics.
Collapse
|
21
|
Risticevic S, DeEll JR, Pawliszyn J. Solid phase microextraction coupled with comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry for high-resolution metabolite profiling in apples: Implementation of structured separations for optimization of sample preparation procedure in complex samples. J Chromatogr A 2012; 1251:208-218. [DOI: 10.1016/j.chroma.2012.06.052] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 06/06/2012] [Accepted: 06/10/2012] [Indexed: 10/28/2022]
|