Fanoudi H, Torabizadeh C, Rakhshan M, Shahcheraghi GH. Development and psychometric evaluation of a pneumatic tourniquet work standards scale.
J Orthop Surg Res 2024;
19:433. [PMID:
39061045 PMCID:
PMC11282809 DOI:
10.1186/s13018-024-04920-8]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 07/15/2024] [Indexed: 07/28/2024] Open
Abstract
OBJECTIVE
Pneumatic tourniquets are among the most essential equipment for controlling bleeding in orthopedic surgeries. However, incorrect application of pneumatic tourniquets is accompanied by many hazards and complications for patients. Evaluation of surgical teams' use of pneumatic tourniquets and establishment of protocols can play an important role in improving patient safety, minimizing risks, and increasing the lifetime of this equipment. Accordingly, the present study was conducted to develop and assess the psychometric properties of a pneumatic tourniquet work standards scale.
METHODS
The present study is a methodological work carried out in two stages. In the first stage, an initial version of the scale was developed based on existing research and panel reviews. In the second stage, the psychometric properties of the scale were tested in terms of face validity (measured qualitatively and quantitatively), content validity (measured qualitatively and quantitatively), item analysis, construct validity, and reliability (internal consistency and stability).
RESULTS
The initial version of the scale consisted of 91 items. After several meetings of the research team, the number of items decreased to 81. In the course of face and content validity testing, 40 items were eliminated, leaving 41 items on the scale when it entered the construct validity testing stage. For evaluation of construct validity, a sample of 300 operating room nurses was recruited. The Exploratory Factor Analysis (EFA) results showed a structure supported by seven factors and 41 items. The reliability of the scale was confirmed by internal consistency analysis, with a good Cronbach's alpha (0.85), and test-retest analysis, with good values of ICC (0.95).
CONCLUSION
The present instrument is a reliable and valid scale which fills the gap in assessment of surgical team members' use of pneumatic tourniquets. The developed scale can be employed by researchers and managers of medical centers to identify hazards in applying pneumatic tourniquets and devise educational programs to eliminate or reduce the existing issues.
Collapse