1
|
Sharma P, Hasan MR, Naikoo UM, Khatoon S, Pilloton R, Narang J. Aptamer Based on Silver Nanoparticle-Modified Flexible Carbon Ink Printed Electrode for the Electrochemical Detection of Chikungunya Virus. BIOSENSORS 2024; 14:344. [PMID: 39056620 PMCID: PMC11274990 DOI: 10.3390/bios14070344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 07/10/2024] [Accepted: 07/11/2024] [Indexed: 07/28/2024]
Abstract
Medical devices have progressed from their initial bulky forms to smart devices. However, their rigidity hampers their seamless integration into everyday life. The fields of stretchable, textile, and flexible electronics are emerging research areas with the potential to drive significant technological progress. This research presents a laboratory-based technique to produce highly sensitive and flexible biosensors for detecting the chikungunya virus. These biosensors are based on 0D nanomaterials and demonstrate significant advancements in voltammetry. The electrochemical platform was created utilizing the stencil printing (StPE) technique. Adapting the biosensor setup involved the selection of aptamer as the biorecognition element bound with silver nanoparticles (AgNPs). This biosensor was employed in the voltammetric identification of the Chikungunya virus antigen (CHIKV-Ag) within a solution containing 0.5 mM potassium ferro/ferri cyanide, a redox pair. The biosensor was employed to evaluate CHIKV-Ag within a human serum sample. It demonstrated a linear detection span ranging from 0.1 ng/mL to 1 μg/mL, with a detection limit of 0.1 ng/mL for CHIKV-Ag. The proposed approach, due to its flexibility in production and the electrocatalytic attributes displayed by the zero-dimensional nanostructure, presents innovative opportunities for cost-effective and tailored aptamer-based bioelectronics, thereby broadening the scope of this domain.
Collapse
Affiliation(s)
- Pradakshina Sharma
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India; (P.S.); (M.R.H.); (U.M.N.); (S.K.)
| | - Mohd. Rahil Hasan
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India; (P.S.); (M.R.H.); (U.M.N.); (S.K.)
| | - Ubaid Mushtaq Naikoo
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India; (P.S.); (M.R.H.); (U.M.N.); (S.K.)
| | - Shaheen Khatoon
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India; (P.S.); (M.R.H.); (U.M.N.); (S.K.)
| | - Roberto Pilloton
- Institute of Crystallography, National Research Council, 00143 Rome, Italy
| | - Jagriti Narang
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India; (P.S.); (M.R.H.); (U.M.N.); (S.K.)
| |
Collapse
|
2
|
Cheng Y, Jiang N, Diao J, Zheng L. Achieving cinnamic acid amides in water by a variant of acyltransferase from Mycobacterium smegmatis and its immobilized form using Ni-NTA modified aspen powder as a carrier. Int J Biol Macromol 2024; 261:129849. [PMID: 38296141 DOI: 10.1016/j.ijbiomac.2024.129849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/26/2024] [Accepted: 01/28/2024] [Indexed: 02/04/2024]
Abstract
An aqueous N-acylation reaction for preparing cinnamic acid amides was realized by using a variant of acyltransferase from Mycobacterium smegmatis (MsAcT-L12A), whereas the wild-type MsAcT showed no activity. MsAcT-L12A exhibited broad substrate adaptability, and preferred the substrates with electron-donating group. When the vinyl cinnamate (1a, 40 mM) and p-methoxyaniline (2a, 4 mM) were involved in the reaction, the excellent yield reached to 86.7 % ± 2.1 % within 3 h by MsAcT-L12A (1 mgpro./mL) in a PBS buffer (100 mM, pH 8.0) at 25 °C. The aqueous N-acylation reaction could be further improved by using an immobilized MsAcT-L12A. The biomass aspen powder (AP) as a carrier provided a low-cost, green, and environmental-friendly immobilization strategy. After it was modified by Ni-NTA, the obtained Ni-NAP could realize one-step purification and immobilization of MsAcT-L12A. The accomplished MsAcT-L12A-Ni-NAP exhibited excellent stability and recyclability, and retained its relative yield as 83.3 % ± 2.2 % even after the 7th cycle of reuse. Using only PBS buffer as a reaction medium, the operation for MsAcT-L12A-catalyzed acyl transfer was greatly simplified, and the improved stabilities of MsAcT-L12A-Ni-NAP could enhance its application potential.
Collapse
Affiliation(s)
- Yuan Cheng
- Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education, School of Life Sciences, Jilin University, Changchun 130012, China
| | - Nan Jiang
- Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education, School of Life Sciences, Jilin University, Changchun 130012, China
| | - Jiali Diao
- Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education, School of Life Sciences, Jilin University, Changchun 130012, China
| | - Liangyu Zheng
- Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education, School of Life Sciences, Jilin University, Changchun 130012, China.
| |
Collapse
|
3
|
Taleb MA, Kalam A, Alghamdi NA, Salem WM. Green and sustainable tannin-immobilized cellulose dipstick for metallochromic sensing of ferric cations. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
Bordbar MM, Sheini A, Hashemi P, Hajian A, Bagheri H. Disposable Paper-Based Biosensors for the Point-of-Care Detection of Hazardous Contaminations-A Review. BIOSENSORS 2021; 11:316. [PMID: 34562906 PMCID: PMC8464915 DOI: 10.3390/bios11090316] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 08/29/2021] [Accepted: 09/01/2021] [Indexed: 02/07/2023]
Abstract
The fast detection of trace amounts of hazardous contaminations can prevent serious damage to the environment. Paper-based sensors offer a new perspective on the world of analytical methods, overcoming previous limitations by fabricating a simple device with valuable benefits such as flexibility, biocompatibility, disposability, biodegradability, easy operation, large surface-to-volume ratio, and cost-effectiveness. Depending on the performance type, the device can be used to analyze the analyte in the liquid or vapor phase. For liquid samples, various structures (including a dipstick, as well as microfluidic and lateral flow) have been constructed. Paper-based 3D sensors are prepared by gluing and folding different layers of a piece of paper, being more user-friendly, due to the combination of several preparation methods, the integration of different sensor elements, and the connection between two methods of detection in a small set. Paper sensors can be used in chromatographic, electrochemical, and colorimetric processes, depending on the type of transducer. Additionally, in recent years, the applicability of these sensors has been investigated in various applications, such as food and water quality, environmental monitoring, disease diagnosis, and medical sciences. Here, we review the development (from 2010 to 2021) of paper methods in the field of the detection and determination of toxic substances.
Collapse
Affiliation(s)
- Mohammad Mahdi Bordbar
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran 19945, Iran;
| | - Azarmidokht Sheini
- Department of Mechanical Engineering, Shohadaye Hoveizeh Campus of Technology, Shahid Chamran University of Ahvaz, Dashte Azadegan 78986, Iran;
| | - Pegah Hashemi
- Research and Development Department, Farin Behbood Tashkhis Ltd., Tehran 16471, Iran;
| | - Ali Hajian
- Institute of Sensor and Actuator Systems, TU Wien, Gusshausstrasse 27-29, 1040 Vienna, Austria;
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran 19945, Iran;
| |
Collapse
|
5
|
Mooranian A, Jones M, Ionescu CM, Walker D, Wagle SR, Kovacevic B, Chester J, Foster T, Johnston E, Mikov M, Al-Salami H. Advancements in Assessments of Bio-Tissue Engineering and Viable Cell Delivery Matrices Using Bile Acid-Based Pharmacological Biotechnologies. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1861. [PMID: 34361247 PMCID: PMC8308343 DOI: 10.3390/nano11071861] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/07/2021] [Accepted: 07/14/2021] [Indexed: 12/18/2022]
Abstract
The utilisation of bioartificial organs is of significant interest to many due to their versatility in treating a wide range of disorders. Microencapsulation has a potentially significant role in such organs. In order to utilise microcapsules, accurate characterisation and analysis is required to assess their properties and suitability. Bioartificial organs or transplantable microdevices must also account for immunogenic considerations, which will be discussed in detail. One of the most characterized cases is the investigation into a bioartificial pancreas, including using microencapsulation of islets or other cells, and will be the focus subject of this review. Overall, this review will discuss the traditional and modern technologies which are necessary for the characterisation of properties for transplantable microdevices or organs, summarizing analysis of the microcapsule itself, cells and finally a working organ. Furthermore, immunogenic considerations of such organs are another important aspect which is addressed within this review. The various techniques, methodologies, advantages, and disadvantages will all be discussed. Hence, the purpose of this review is providing an updated examination of all processes for the analysis of a working, biocompatible artificial organ.
Collapse
Affiliation(s)
- Armin Mooranian
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Melissa Jones
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Corina Mihaela Ionescu
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Daniel Walker
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Susbin Raj Wagle
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Bozica Kovacevic
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Jacqueline Chester
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Thomas Foster
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Edan Johnston
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| | - Momir Mikov
- Department of Pharmacology, Toxicology and Clinical Pharmacology, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21101 Novi Sad, Serbia;
| | - Hani Al-Salami
- The Biotechnology and Drug Development Research Laboratory, Curtin Medical School, Curtin Health Innovation Research Institute, Curtin University, Bentley, Perth, WA 6102, Australia; (A.M.); (M.J.); (C.M.I.); (D.W.); (S.R.W.); (B.K.); (J.C.); (T.F.); (E.J.)
- Hearing Therapeutics, Ear Science Institute Australia, Queen Elizabeth II Medical Centre, Nedlands, Perth, WA 6009, Australia
| |
Collapse
|
6
|
Strategies for the detection of target analytes using microfluidic paper-based analytical devices. Anal Bioanal Chem 2021; 413:2429-2445. [PMID: 33712916 DOI: 10.1007/s00216-021-03213-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 01/28/2021] [Accepted: 02/01/2021] [Indexed: 12/11/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) have developed rapidly in recent years, because of their advantages, such as small sample volume, rapid detection rates, low cost, and portability. Due to these characteristics, they can be used for in vitro diagnostics in the laboratory, or in the field, for a variety of applications, including food evaluation, disease screening, environmental monitoring, and drug testing. This review will present various detection methods employed by μPADs and their respective applications for the detection of target analytes. These include colorimetry, electrochemistry, chemiluminescence (CL), electrochemiluminescence (ECL), and fluorescence-based methodologies. At the same time, the choice of labeling material and the design of microfluidic channels are also important for detection results. The construction of novel nanocomponents and different smart structures of paper-based devices have improved the performance of μPADs and we will also highlight some of these in this manuscript. Additionally, some key challenges and future prospects for the use of μPADs are briefly discussed.
Collapse
|
7
|
Jafry AT, Lim H, Lee J. Basic Paper-Based Microfluidics/Electronics Theory. Bioanalysis 2021. [DOI: 10.1007/978-981-15-8723-8_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
8
|
Teng X, Li F, Lu C. Visualization of materials using the confocal laser scanning microscopy technique. Chem Soc Rev 2020; 49:2408-2425. [PMID: 32134417 DOI: 10.1039/c8cs00061a] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The development of materials science always benefits from advanced characterizations. Currently, imaging techniques are of great technological importance in both fundamental and applied research on materials. In comparison to conventional visualization methods, confocal laser scanning microscopy (CLSM) is non-invasive, with macroscale and high-contrast scanning, a simple and fast sample preparation procedure as well as easy operation. In addition, CLSM allows rapid acquisition of longitudinal and cross-sectional images at any position in a material. Therefore, the CLSM-based visualization technique could provide direct and model-independent insight into material characterizations. This review summarizes the recent applications of CLSM in materials science. The current CLSM approaches for the visualization of surface structures, internal structures, spatial structures and reaction processes are discussed in detail. Finally, we provide our thoughts and predictions on the future development of CLSM in materials science. The purpose of this review is to guide researchers to build a suitable CLSM approach for material characterizations, and to open viable opportunities and inspirations for the development of new strategies aiming at the preparation of advanced materials. We hope that this review will be useful for a wide range of research communities of materials science, chemistry, and engineering.
Collapse
Affiliation(s)
- Xu Teng
- Beijing Advanced Innovation Center for Soft Matter Science and Engineering (BAICAS), State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
| | | | | |
Collapse
|
9
|
Akyazi T, Basabe-Desmonts L, Benito-Lopez F. Review on microfluidic paper-based analytical devices towards commercialisation. Anal Chim Acta 2018; 1001:1-17. [DOI: 10.1016/j.aca.2017.11.010] [Citation(s) in RCA: 311] [Impact Index Per Article: 51.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 10/23/2017] [Accepted: 11/03/2017] [Indexed: 12/20/2022]
|
10
|
Wang F, Zhang X, Shao L, Cui Z, Nie T. Synthesis of magnetic Fe3O4/polyamine hybrid microsphere using O/W/O Pickering emulsion droplet as the polymerization micro-reactor. RSC Adv 2015. [DOI: 10.1039/c5ra00997a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An O/W/O emulsion containing Fe3O4NPs and PEI was obtained using SM-CaCO3NPs as the stabilizer. In a droplet-to-droplet reaction mode, a magnetic polyamine microsphere was achieved by crosslinking PEI in the emulsion droplet with glutaraldehyde.
Collapse
Affiliation(s)
- Feng Wang
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi 214122
- People's Republic of China
| | - Xuan Zhang
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi 214122
- People's Republic of China
| | - Linlin Shao
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi 214122
- People's Republic of China
| | - Zhenggang Cui
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi 214122
- People's Republic of China
- The Key Laboratory of Food Colloids and Biotechnology of Ministry of Education
| | - Tingting Nie
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi 214122
- People's Republic of China
| |
Collapse
|
11
|
Wang F, Nie TT, Shao LL, Cui Z. Comparison of physical and covalent immobilization of lipase fromCandida antarcticaon polyamine microspheres of alkylamine matrix. BIOCATAL BIOTRANSFOR 2014. [DOI: 10.3109/10242422.2014.977266] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
12
|
Abstract
Paper has become increasingly recognized as a very interesting substrate for the construction of microfluidic devices, with potential application in a variety of areas, including health diagnosis, environmental monitoring, immunoassays and food safety. The aim of this review is to present a short history of analytical systems constructed from paper, summarize the main advantages and disadvantages of fabrication techniques, exploit alternative methods of detection such as colorimetric, electrochemical, photoelectrochemical, chemiluminescence and electrochemiluminescence, as well as to take a closer look at the novel achievements in the field of bioanalysis published during the last 2 years. Finally, the future trends for production of such devices are discussed.
Collapse
|
13
|
Sensing approaches on paper-based devices: a review. Anal Bioanal Chem 2013; 405:7573-95. [DOI: 10.1007/s00216-013-6911-4] [Citation(s) in RCA: 313] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 02/25/2013] [Accepted: 03/08/2013] [Indexed: 01/24/2023]
|
14
|
Zhang Y, Rochefort D. Characterisation and applications of microcapsules obtained by interfacial polycondensation. J Microencapsul 2012; 29:636-49. [DOI: 10.3109/02652048.2012.676092] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
15
|
Orelma H, Teerinen T, Johansson LS, Holappa S, Laine J. CMC-Modified Cellulose Biointerface for Antibody Conjugation. Biomacromolecules 2012; 13:1051-8. [DOI: 10.1021/bm201771m] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Hannes Orelma
- Aalto University, School of Chemical Technology, Department of Forest Products Technology,
Espoo, Finland
| | - Tuija Teerinen
- VTT Technical Research Centre of Finland, 02044 VTT, Espoo, Finland
| | - Leena-Sisko Johansson
- Aalto University, School of Chemical Technology, Department of Forest Products Technology,
Espoo, Finland
| | - Susanna Holappa
- Aalto University, School of Chemical Technology, Department of Forest Products Technology,
Espoo, Finland
| | - Janne Laine
- Aalto University, School of Chemical Technology, Department of Forest Products Technology,
Espoo, Finland
| |
Collapse
|
16
|
Guerrero M, Bertrand F, Rochefort D. Activity, stability and inhibition of a bioactive paper prepared by large-scale coating of laccase microcapsules. Chem Eng Sci 2011. [DOI: 10.1016/j.ces.2011.07.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
17
|
Savolainen A, Zhang Y, Rochefort D, Holopainen U, Erho T, Virtanen J, Smolander M. Printing of Polymer Microcapsules for Enzyme Immobilization on Paper Substrate. Biomacromolecules 2011; 12:2008-15. [DOI: 10.1021/bm2003434] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Anne Savolainen
- VTT Technical Research Center of Finland, VTT P.O. Box 1000, 02044 VTT, Finland
| | - Yufen Zhang
- Département de Chimie, Université de Montréal, CP6128 Succ. Centre-Ville, Montréal, Québec, Canada H3C 3J7
| | - Dominic Rochefort
- Département de Chimie, Université de Montréal, CP6128 Succ. Centre-Ville, Montréal, Québec, Canada H3C 3J7
| | - Ulla Holopainen
- VTT Technical Research Center of Finland, VTT P.O. Box 1000, 02044 VTT, Finland
| | - Tomi Erho
- VTT Technical Research Center of Finland, VTT P.O. Box 1000, 02044 VTT, Finland
| | - Jouko Virtanen
- VTT Technical Research Center of Finland, VTT P.O. Box 1000, 02044 VTT, Finland
| | - Maria Smolander
- VTT Technical Research Center of Finland, VTT P.O. Box 1000, 02044 VTT, Finland
| |
Collapse
|
18
|
Activity, conformation and thermal stability of laccase and glucose oxidase in poly(ethyleneimine) microcapsules for immobilization in paper. Process Biochem 2011. [DOI: 10.1016/j.procbio.2011.01.006] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
Zhang Y, Rochefort D. Comparison of emulsion and vibration nozzle methods for microencapsulation of laccase and glucose oxidase by interfacial reticulation of poly(ethyleneimine). J Microencapsul 2010; 27:703-13. [DOI: 10.3109/02652048.2010.509518] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
20
|
Development of an enzymatic microreactor based on microencapsulated laccase with off-line capillary electrophoresis for measurement of oxidation reactions. J Chromatogr A 2009; 1216:8270-6. [DOI: 10.1016/j.chroma.2009.08.069] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2009] [Revised: 08/14/2009] [Accepted: 08/18/2009] [Indexed: 01/24/2023]
|
21
|
Brady D, Jordaan J. Advances in enzyme immobilisation. Biotechnol Lett 2009; 31:1639-50. [DOI: 10.1007/s10529-009-0076-4] [Citation(s) in RCA: 571] [Impact Index Per Article: 38.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2009] [Revised: 06/19/2009] [Accepted: 06/22/2009] [Indexed: 10/20/2022]
|