1
|
Guan Y, Xu F, Sun L, Luo Y, Cheng R, Zou Y, Liao L, Cao Z. Hydrogen Peroxide Electrochemical Sensor Based on Ag/Cu Bimetallic Nanoparticles Modified on Polypyrrole. SENSORS (BASEL, SWITZERLAND) 2023; 23:8536. [PMID: 37896629 PMCID: PMC10611109 DOI: 10.3390/s23208536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/08/2023] [Accepted: 10/10/2023] [Indexed: 10/29/2023]
Abstract
Due to the strong oxidizing properties of H2O2, excessive discharge of H2O2 will cause great harm to the environment. Moreover, H2O2 is also an energetic material used as fuel, with specific attention given to its safety. Therefore, it is of great importance to explore and prepare good sensitive materials for the detection of H2O2 with a low detection limit and high selectivity. In this work, a kind of hydrogen peroxide electrochemical sensor has been fabricated. That is, polypyrrole (PPy) has been electropolymerized on the glass carbon electrode (GCE), and then Ag and Cu nanoparticles are modified together on the surface of polypyrrole by electrodeposition. SEM analysis shows that Cu and Ag nanoparticles are uniformly deposited on the surface of PPy. Electrochemical characterization results display that the sensor has a good response to H2O2 with two linear intervals. The first linear range is 0.1-1 mM (R2 = 0.9978, S = 265.06 μA/ (mM × cm2)), and the detection limit is 0.027 μM (S/N = 3). The second linear range is 1-35 mM (R2 = 0.9969, 445.78 μA/ (mM × cm2)), corresponding to 0.063 μM of detection limit (S/N = 3). The sensor reveals good reproducibility (σ = 2.104), repeatability (σ = 2.027), anti-interference, and stability. The recoveries of the electrode are 99.84-103.00% (for 0.1-1 mM of linear range) and 98.65-104.80% (for 1-35 mM linear range). Furthermore, the costs of the hydrogen peroxide electrochemical sensor proposed in this work are reduced largely by using non-precious metals without degradation of the sensing performance of H2O2. This study provides a facile way to develop nanocomposite electrochemical sensors.
Collapse
Affiliation(s)
- Yanxun Guan
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, China
| | - Fen Xu
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
| | - Lixian Sun
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
| | - Yumei Luo
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
| | - Riguang Cheng
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
| | - Yongjin Zou
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
| | - Lumin Liao
- Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China; (Y.G.); (Y.L.); (R.C.); (Y.Z.); (L.L.)
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, China
| | - Zhong Cao
- Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, Changsha University of Science & Technology, Changsha 410114, China;
| |
Collapse
|
2
|
Umesh NM, rani KK, Devasenathipathy R, Sriram B, Liu YX, Wang SF. Preparation of Co-MOF derived Co(OH)2/multiwalled carbon nanotubes as an efficient bifunctional electro catalyst for hydrazine and hydrogen peroxide detections. J Taiwan Inst Chem Eng 2018. [DOI: 10.1016/j.jtice.2018.08.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
3
|
Guan W, Zhang C, Liu F, Liu M. Chemiluminescence detection for microfluidic cloth-based analytical devices (μCADs). Biosens Bioelectron 2015; 72:114-20. [PMID: 25974173 DOI: 10.1016/j.bios.2015.04.064] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Revised: 04/11/2015] [Accepted: 04/20/2015] [Indexed: 12/19/2022]
Abstract
In this work, we report the first demonstration of chemiluminescence (CL) detection for microfluidic cloth-based analytical devices (μCADs). Wax screen-printing is used to make cloth channels or chambers, and enzyme-catalyzed CL reactions are imaged using an inexpensive charge coupled device (CCD). We first evaluate the relationship between the wicking rate and the length/width of cloth channel. For our device, the channel length and width between the loading and detection chambers are optimized to be 10mm and 3mm. Thus, the detection procedure can be accomplished in about 15s on a cloth-based device (15 × 30 mm(2)) by using 25-μL sample spotted on it. Next, several parameters affecting cloth-based CL intensity are studied, including exposure time, pH, and concentrations of luminol and enzyme. Under optimal conditions, a linear relationship is obtained between CL intensity and hydrogen peroxide (H2O2) concentrations in the range of 0.5-5mM with a detection limit of 0.46 mM. Finally, the utility of cloth-based CL is demonstrated for determination of H2O2 residues in meat samples. On our device, the chicken meat soaked for 6h with 3% H2O2 can be detected. Moreover, the supernatant of grinded meat sample can be directly applied, without need for other treatments. We believe that μCADs with CL detection could provide a new platform of rapid and low-cost assays for use in areas such as food detection and environmental monitoring.
Collapse
Affiliation(s)
- Wenrong Guan
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| | - Feifei Liu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Min Liu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| |
Collapse
|
4
|
Chen X, Guo B, Hu P, Wang Y. A Non-Enzymatic Hydrogen Peroxide Sensor Based on Gold Nanoparticles/Carbon Nanotube/Self-Doped Polyaniline Hollow Spheres. ELECTROANAL 2014. [DOI: 10.1002/elan.201400080] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Park JW, Park SJ, Kwon OS, Lee C, Jang J. Polypyrrole Nanotube Embedded Reduced Graphene Oxide Transducer for Field-Effect Transistor-Type H2O2 Biosensor. Anal Chem 2014; 86:1822-8. [DOI: 10.1021/ac403770x] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Jin Wook Park
- School
of Chemical and Biological Engineering, Seoul National University, Seoul 151-742, Korea
| | - Seon Joo Park
- School
of Chemical and Biological Engineering, Seoul National University, Seoul 151-742, Korea
| | - Oh Seok Kwon
- School
of Chemical and Biological Engineering, Seoul National University, Seoul 151-742, Korea
- Department
of Chemistry, Massachusetts Institute of Technology, 77 Massachusetts
Avenue, Cambridge, Massachusetts 02139, United States
| | - Choonghyeon Lee
- School
of Chemical and Biological Engineering, Seoul National University, Seoul 151-742, Korea
| | - Jyongsik Jang
- School
of Chemical and Biological Engineering, Seoul National University, Seoul 151-742, Korea
| |
Collapse
|
6
|
Martins PR, Gonçalves Nery Motta A, Nakamura M, Araki K, Angnes L. Nanostructured Alpha-Nickel Hydroxide Electrodes for High Performance Hydrogen Peroxide Sensing. ELECTROANAL 2013. [DOI: 10.1002/elan.201300288] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
7
|
Electrical characterization and hydrogen peroxide sensing properties of gold/Nafion:polypyrrole/MWCNTs electrochemical devices. SENSORS 2013; 13:3878-88. [PMID: 23529125 PMCID: PMC3658780 DOI: 10.3390/s130303878] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2013] [Revised: 03/05/2013] [Accepted: 03/12/2013] [Indexed: 11/18/2022]
Abstract
Electrochemical devices using as substrates copier grade transparency sheets are developed by using ion conducting Nafion: polypyrrole mixtures, deposited between gold bottom electrodes and upper electrodes based on Multi Walled Carbon Nanotubes (MWCNTs). The electrical properties of the Nafion:polypyrrole blends and of the gold/Nafion:polypyrrole/MWCNTs devices are investigated under dry conditions and in deionized water by means of frequency dependent impedance measurements and time domain electrical characterization. According to current-voltage measurements carried out in deionized water, the steady state current forms cycles characterized by redox peaks, the intensity and position of which reversibly change in response to H2O2, with a lower detection limit in the micromolar range. The sensitivity that is obtained is comparable with that of other electrochemical sensors that however, unlike our devices, require supporting electrolytes.
Collapse
|