1
|
Pepi S, Talarico L, Leone G, Bonechi C, Consumi M, Boldrini A, Lauro A, Magnani A, Rossi C. Effect of Mild Conditions on PVA-Based Theta Gel Preparation: Thermal and Rheological Characterization. Int J Mol Sci 2024; 25:12039. [PMID: 39596107 PMCID: PMC11593468 DOI: 10.3390/ijms252212039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Revised: 10/31/2024] [Accepted: 11/01/2024] [Indexed: 11/28/2024] Open
Abstract
Polyvinyl alcohol (PVA), possessing a strong ability to form hydrogels, has been widely used for various pharmaceutical and biomedical applications. In particular, the use of PVA-PEG in the form of theta gels for altered cartilage treatment has attracted an enormous amount of attention in the last 20 years. In this paper, we prepared 42 PVA-PEG in the form of theta gels at room temperature in an aqueous environment, testing the crystallization occurrence at basic pH (10 or 12). Using a statistical approach, the effect of PEG molecular weight, PVA molecular weight and alkaline pH values on water content and mechanical performance was evaluated. The used procedure permitted the theta gels to maintain swelling properties comparable to those of human cartilage, from 60% to 85%, with both polymers having the same influence. PEG MW mainly affected the hydrophilic properties, whereas the thermal properties were mostly influenced by the PVA. The shear and compression mechanical behavior of the produced materials were affected by both the polymers' MWs. The sample obtained using PVA 125 kDa with PEG 20 kDa as a porogen appeared to be the most suitable one for cartilage disease treatment, as it had an equilibrium shear modulus in the range of 50-250 kPa, close to that of native articular cartilage, as well as optimal mechanical response under compression along the entire analyzed frequency range with a mean value of 0.12 MPa and a coefficient of friction (COF) which remained under 0.10 for all the tested sliding speeds (mm/s).
Collapse
Affiliation(s)
- Simone Pepi
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Luigi Talarico
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Gemma Leone
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Claudia Bonechi
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- Centre for Colloid and Surface Science (CSGI), Via della Lastruccia 3, Sesto Fiorentino (FI), 50019 Florence, Italy
| | - Marco Consumi
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Amedeo Boldrini
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- Centre for Colloid and Surface Science (CSGI), Via della Lastruccia 3, Sesto Fiorentino (FI), 50019 Florence, Italy
| | - Alessia Lauro
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
| | - Agnese Magnani
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Claudio Rossi
- Department of Biotechnology, Chemistry and Pharmacy, University of Siena, Via A. Moro 2, 53100 Siena, Italy; (S.P.); (L.T.); (C.B.); (M.C.); (A.B.); (C.R.)
- Centre for Colloid and Surface Science (CSGI), Via della Lastruccia 3, Sesto Fiorentino (FI), 50019 Florence, Italy
| |
Collapse
|
2
|
Chen Y, Yang M, Zhang W, Guo W, Zhang X, Zhang B. Facile Preparation of Irradiated Poly(vinyl alcohol)/Cellulose Nanofiber Hydrogels with Ultrahigh Mechanical Properties for Artificial Joint Cartilage. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4125. [PMID: 39203302 PMCID: PMC11356198 DOI: 10.3390/ma17164125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 08/05/2024] [Accepted: 08/17/2024] [Indexed: 09/03/2024]
Abstract
In this study, Poly(vinyl alcohol)/cellulose nanofiber (PVA/CNF) hydrogels have been successfully prepared using γ-ray irradiation, annealing, and rehydration processes. In addition, the effects of CNF content and annealing methods on the hydrogel properties, including gel fraction, micromorphology, crystallinity, swelling behavior, and tensile and friction properties, are investigated. Consequently, the results show that at an absorbed dose of 30 kGy, the increase in CNF content increases the gel fraction, tensile strength, and elongation at break of irradiated PVA/CNF hydrogels, but decreases the water absorption. In addition, the cross-linking density of the PVA/CNF hydrogels is significantly increased at an annealing temperature of 80 °C, which leads to the transition of the cross-sectional micromorphology from porous networks to smooth planes. For the PVA/CNF hydrogel with a CNF content of 0.6%, the crystallinity increases from 19.9% to 25.8% after tensile annealing of 30% compared to the original composite hydrogel. The tensile strength is substantially increased from 65.5 kPa to 21.2 MPa, and the modulus of elasticity reaches 4.2 MPa. Furthermore, it shows an extremely low coefficient of friction (0.075), which suggests that it has the potential to be applied as a material for artificial joint cartilage.
Collapse
Affiliation(s)
- Yang Chen
- Institute of Isotope, Henan Academy of Sciences Co., Ltd., Zhengzhou 450015, China; (Y.C.); (W.G.); (B.Z.)
- Henan Radiation New Materials Engineering Technology Research Center, Zhengzhou 450015, China
| | - Mingcheng Yang
- Institute of Isotope, Henan Academy of Sciences Co., Ltd., Zhengzhou 450015, China; (Y.C.); (W.G.); (B.Z.)
- Henan Radiation New Materials Engineering Technology Research Center, Zhengzhou 450015, China
| | - Weiwei Zhang
- Key Biomass Energy Laboratory of Henan Province, Zhengzhou 450008, China; (W.Z.); (X.Z.)
| | - Wenhui Guo
- Institute of Isotope, Henan Academy of Sciences Co., Ltd., Zhengzhou 450015, China; (Y.C.); (W.G.); (B.Z.)
- Henan Radiation New Materials Engineering Technology Research Center, Zhengzhou 450015, China
| | - Xiuqiang Zhang
- Key Biomass Energy Laboratory of Henan Province, Zhengzhou 450008, China; (W.Z.); (X.Z.)
| | - Benshang Zhang
- Institute of Isotope, Henan Academy of Sciences Co., Ltd., Zhengzhou 450015, China; (Y.C.); (W.G.); (B.Z.)
- Henan Radiation New Materials Engineering Technology Research Center, Zhengzhou 450015, China
| |
Collapse
|
3
|
You L, Zheng Z, Xu W, Wang Y, Xiong W, Xiong C, Wang S. Self-healing and adhesive MXene-polypyrrole/silk fibroin/polyvinyl alcohol conductive hydrogels as wearable sensor. Int J Biol Macromol 2024; 263:130439. [PMID: 38423420 DOI: 10.1016/j.ijbiomac.2024.130439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 02/21/2024] [Accepted: 02/23/2024] [Indexed: 03/02/2024]
Abstract
Conductive hydrogels become increasing attractive for flexible electronic devices and biosensors. However, challenges still remain in fabrication of flexible hydrogels with high electrical conductivity, self-healing capability and adhesion property. Herein, a conductive hydrogel (PSDM) was prepared by solution-gel method using MXene and dopamine modified polypyrrole as conductive enhanced materials, polyvinyl alcohol and silk fibroin as gel networks, and borax as cross-linking agent. Notably, the PSDM hydrogels not only showed high permeability (13.82 mg∙cm-2∙h-1), excellent stretch ability (1235 %), high electrical conductivity (11.3 S/m) and long-term stability, but also exhibited high adhesion performance and self-healing properties. PSDM hydrogels displayed outstanding sensing performance and durability for monitoring human activities including writing, finger bending and wrist bending. The PSDM hydrogel was made into wearable flexible electrodes and realized accurate, sensitive and reliable detection of human electromyographic and electrocardiographic signals. The sensor was also applied in human-computer interaction by collecting electromyography signals of different gestures for machine learning and gesture recognition. According to 480 groups of data collected, the recognition accuracy of gestures by the electrodes was close to 100 %, indicating that the PSDM hydrogel electrodes possessed excellent sensing performance for high precision data acquisition and human-computer interaction interface.
Collapse
Affiliation(s)
- Lijun You
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China.
| | - Zhijuan Zheng
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China
| | - Wenjing Xu
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China
| | - Yang Wang
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China
| | - Weijie Xiong
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China
| | - Caihua Xiong
- School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shaoyun Wang
- College of Biological Science and Engineering, Fuzhou University, Fuzhou 350108, China.
| |
Collapse
|
4
|
Song X, Man J, Qiu Y, Wang J, Liu J, Li R, Zhang Y, Li J, Li J, Chen Y. Design, preparation, and characterization of lubricating polymer brushes for biomedical applications. Acta Biomater 2024; 175:76-105. [PMID: 38128641 DOI: 10.1016/j.actbio.2023.12.024] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/21/2023] [Accepted: 12/14/2023] [Indexed: 12/23/2023]
Abstract
The lubrication modification of biomedical devices significantly enhances the functionality of implanted interventional medical devices, thereby providing additional benefits for patients. Polymer brush coating provides a convenient and efficient method for surface modification while ensuring the preservation of the substrate's original properties. The current research has focused on a "trial and error" method to finding polymer brushes with superior lubricity qualities, which is time-consuming and expensive, as obtaining effective and long-lasting lubricity properties for polymer brushes is difficult. This review summarizes recent research advances in the biomedical field in the design, material selection, preparation, and characterization of lubricating and antifouling polymer brushes, which follow the polymer brush development process. This review begins by examining various approaches to polymer brush design, including molecular dynamics simulation and machine learning, from the fundamentals of polymer brush lubrication. Recent advancements in polymer brush design are then synthesized and potential avenues for future research are explored. Emphasis is placed on the burgeoning field of zwitterionic polymer brushes, and highlighting the broad prospects of supramolecular polymer brushes based on host-guest interactions in the field of self-repairing polymer brush applications. The review culminates by providing a summary of methodologies for characterizing the structural and functional attributes of polymer brushes. It is believed that a development approach for polymer brushes based on "design-material selection-preparation-characterization" can be created, easing the challenge of creating polymer brushes with high-performance lubricating qualities and enabling the on-demand creation of coatings. STATEMENT OF SIGNIFICANCE: Biomedical devices have severe lubrication modification needs, and surface lubrication modification by polymer brush coating is currently the most promising means. However, the design and preparation of polymer brushes often involves "iterative testing" to find polymer brushes with excellent lubrication properties, which is both time-consuming and expensive. This review proposes a polymer brush development process based on the "design-material selection-preparation-characterization" strategy and summarizes recent research advances and trends in the design, material selection, preparation, and characterization of polymer brushes. This review will help polymer brush researchers by alleviating the challenges of creating polymer brushes with high-performance lubricity and promises to enable the on-demand construction of polymer brush lubrication coatings.
Collapse
Affiliation(s)
- Xinzhong Song
- Key Laboratory of High Efficiency and Clean Mechanicalanufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, PR China; Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, PR China
| | - Jia Man
- Key Laboratory of High Efficiency and Clean Mechanicalanufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, PR China; Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, PR China.
| | - Yinghua Qiu
- Key Laboratory of High Efficiency and Clean Mechanicalanufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, PR China; Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, PR China
| | - Jiali Wang
- Qilu Hospital of Shandong University, Jinan 250012, PR China
| | - Jianing Liu
- Qilu Hospital of Shandong University, Jinan 250012, PR China
| | - Ruijian Li
- Qilu Hospital of Shandong University, Jinan 250012, PR China
| | - Yongqi Zhang
- Key Laboratory of High Efficiency and Clean Mechanicalanufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, PR China; Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, PR China
| | - Jianyong Li
- Key Laboratory of High Efficiency and Clean Mechanicalanufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, PR China; Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, PR China
| | - Jianfeng Li
- Key Laboratory of High Efficiency and Clean Mechanicalanufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, PR China; Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, PR China
| | - Yuguo Chen
- Qilu Hospital of Shandong University, Jinan 250012, PR China
| |
Collapse
|
5
|
Hua J, Su M, Sun X, Li J, Sun Y, Qiu H, Shi Y, Pan L. Hydrogel-Based Bioelectronics and Their Applications in Health Monitoring. BIOSENSORS 2023; 13:696. [PMID: 37504095 PMCID: PMC10377104 DOI: 10.3390/bios13070696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 06/17/2023] [Accepted: 06/26/2023] [Indexed: 07/29/2023]
Abstract
Flexible bioelectronics exhibit promising potential for health monitoring, owing to their soft and stretchable nature. However, the simultaneous improvement of mechanical properties, biocompatibility, and signal-to-noise ratio of these devices for health monitoring poses a significant challenge. Hydrogels, with their loose three-dimensional network structure that encapsulates massive amounts of water, are a potential solution. Through the incorporation of polymers or conductive fillers into the hydrogel and special preparation methods, hydrogels can achieve a unification of excellent properties such as mechanical properties, self-healing, adhesion, and biocompatibility, making them a hot material for health monitoring bioelectronics. Currently, hydrogel-based bioelectronics can be used to fabricate flexible bioelectronics for motion, bioelectric, and biomolecular acquisition for human health monitoring and further clinical applications. This review focuses on materials, devices, and applications for hydrogel-based bioelectronics. The main material properties and research advances of hydrogels for health monitoring bioelectronics are summarized firstly. Then, we provide a focused discussion on hydrogel-based bioelectronics for health monitoring, which are classified as skin-attachable, implantable, or semi-implantable depending on the depth of penetration and the location of the device. Finally, future challenges and opportunities of hydrogel-based bioelectronics for health monitoring are envisioned.
Collapse
Affiliation(s)
- Jiangbo Hua
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Mengrui Su
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Xidi Sun
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Jiean Li
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Yuqiong Sun
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Hao Qiu
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Yi Shi
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Lijia Pan
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
6
|
Lee MJ, Espinosa-Marzal RM. Intrinsic and Extrinsic Tunability of Double-Network Hydrogel Strength and Lubricity. ACS APPLIED MATERIALS & INTERFACES 2023; 15:20495-20507. [PMID: 37053001 PMCID: PMC10141240 DOI: 10.1021/acsami.3c00949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
Double-network (DN) hydrogels are promising materials for tissue engineering due to their biocompatibility, high strength, and toughness, but understanding of their microstructure-property relationships still remains limited. This work investigates a DN hydrogel comprising a physically crosslinked agarose, as the first network, and a chemically crosslinked copolymer with a varying ratio of acrylamide and acrylic acid, as the second network. The charge, intrinsic to most DN hydrogels, introduces a responsive behavior to chemical and electrical stimuli. The DN strengthens agarose hydrogels, but the strengthening decreases with the swelling ratio resulting from increasing acrylic acid content or reducing salt concentration. Through careful imaging by atomic force microscopy, the heterogenous surface structure and properties arising from the DN are resolved, while the lubrication mechanisms are elucidated by studying the heterogeneous frictional response to extrinsic stimuli. This method reveals the action of the first (agarose) network (forming grain boundaries), copolymer-rich and poor regions (in grains), charge and swelling in providing lubrication. Friction arises from the shear of the polymeric network, whereas hydrodynamic lift and viscoelastic deformation become more significant at higher sliding velocities. We identify the copolymer-rich phase as the main source of the stimulus-responsive behavior. Salt concentration enhances effective charge density and reduces viscoelastic deformation, while electric bias swells the gel and improves lubrication. This work also demonstrates the dynamic control of interfacial properties like hydrogel friction and adhesion, which has implications for other areas of study like soft robotics and tissue replacements.
Collapse
Affiliation(s)
- Ming Jun Lee
- Department
of Materials Science and Engineering, University
of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Rosa M. Espinosa-Marzal
- Department
of Materials Science and Engineering, University
of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department
of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
7
|
Chen Y, Song J, Wang S, Liu W. Cationic Modified PVA Hydrogels Provide Low Friction and Excellent Mechanical Properties for Potential Cartilage and Orthopedic Applications. Macromol Biosci 2023; 23:e2200275. [PMID: 36254859 DOI: 10.1002/mabi.202200275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 09/27/2022] [Indexed: 01/19/2023]
Abstract
Poly(vinyl alcohol) (PVA) hydrogel is a promising candidate for articular cartilage repair yet restrained by its mechanical strength and tribological property. Current work reports a newly designed PVA-based hydrogel modified by glycerol (g), bacterial cellulose (BC), and a cationic polymer poly (diallyl dimethylammonium chloride) (PDMDAAC), which is a novel cationic strengthening choice. The resultant PVA-g-BC-PDMDAAC hydrogel proves the effectiveness of this modification scheme, with a confined compressive modulus of 19.56 MPa and a friction coefficient of 0.057 at a joint-equivalent load and low sliding speed. The water content, swelling property, and creep behavior of this hydrogel are also within a cartilage-mimetic range. The properties of PVA-based hydrogels before PDMDAAC addition are likewise studied as a cross-reference. Besides, PDMDAAC-modified PVA hydrogel realizes ideal mechanical and lubrication properties with a relatively low PVA concentration (10 wt.%) and facile fabrication process, which lays a foundation for mass production and marketization in the future.
Collapse
Affiliation(s)
- Yuru Chen
- Department of Mechanical Engineering, Tsinghua University, 100084, Beijing, China.,Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China
| | - Jian Song
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, 518107, Shenzhen, China
| | - Song Wang
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, 518057, Shenzhen, China
| | - Weiqiang Liu
- Department of Mechanical Engineering, Tsinghua University, 100084, Beijing, China.,Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China.,Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, 518057, Shenzhen, China
| |
Collapse
|
8
|
Gao L, He X, Zhang T, Li P, An R. Preparation and characterization of polyethylene glycol/chitosan composite water-based wound healing lubricant. Front Bioeng Biotechnol 2022; 10:990249. [PMID: 36185446 PMCID: PMC9516666 DOI: 10.3389/fbioe.2022.990249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
The proportion of pregnant women giving birth through cesarean section is increasing annually worldwide. However, post-cesarean section scar diverticulum is a common condition that occurs and requires better surgical strategies than the methods currently used. We hypothesized that using biological lubricant topically on the incision area during C-section could be an option to minimize the scar. This water-based polyethylene glycol (PEG)/chitosan (CS) composite lubricant was prepared via ultrasonic blending. The product was characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, Fourier-transform infrared spectroscopy, and Raman spectroscopy. The thermal stability of the materials and their heat absorption and release during heating were analyzed using thermogravimetric analysis and differential scanning calorimetry. Tribological tests proved that the PEG/CS composite had a better lubrication effect than either the PEG or CS lubricant alone, and the cell viability experiments verified that it had good biocompatibility. Finally, application of the composite lubricant onto the backs of mice modeling full-thickness skin incisions further confirmed that the product improved both the re-epithelialization and the collagen levels of the wounded skin. In conclusion, we expect our newly formulated PEG/CS composite lubricant to be useful not only for managing post-cesarean section scar diverticulum but also for healing skin wounds in general.
Collapse
|
9
|
Drying-Enhanced Polyvinyl alcohol-Polyacrylic acid Double-Network Hydrogel and Its Application in Flexible Strain Sensors. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.118120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
10
|
Moon HH, Choi EJ, Yun SH, Kim YC, Premkumar T, Song C. Aqueous lubrication and wear properties of nonionic bottle-brush polymers. RSC Adv 2022; 12:17740-17746. [PMID: 35765345 PMCID: PMC9199083 DOI: 10.1039/d2ra02711a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 06/09/2022] [Indexed: 11/21/2022] Open
Abstract
The usage of aqueous lubricants in eco-friendly bio-medical friction systems has attracted significant attention. Several bottle-brush polymers with generally ionic functional groups have been developed based on the structure of biological lubricant lubricin. However, hydrophilic nonionic brush polymers have attracted less attention, especially in terms of wear properties. We developed bottle-brush polymers (BP) using hydrophilic 2-hydroxyethyl methacrylate (HEMA), a highly biocompatible yet nonionic molecule. The lubrication properties of polymer films were analyzed in an aqueous state using a ball-on-disk, which revealed that BPHEMA showed a lower aqueous friction coefficient than linear poly(HEMA), even lower than hyaluronic acid (HA) and polyvinyl alcohol (PVA), which are widely used as lubricating polymers. Significantly, we discovered that the combination of HA, PVA, and BPHEMA is demonstrated to be essential in influencing the surface wear properties; the ratio of 1 : 2 (HA : BPHEMA) had the maximum wear resistance, despite a slight increase in the aqueous friction coefficient.
Collapse
Affiliation(s)
- Hwi Hyun Moon
- Department of Chemistry, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
| | - Eun Jung Choi
- Department of Chemistry, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
| | - Sang Ho Yun
- Department of Chemistry, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
| | - Youn Chul Kim
- Department of Chemical Engineering, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
| | - Thathan Premkumar
- Department of Chemistry, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
- The University College, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
| | - Changsik Song
- Department of Chemistry, Sungkyunkwan University Suwon Gyeonggi 16419 Republic of Korea
| |
Collapse
|
11
|
Wang Y, Yao H, Zu Y, Yin W. Biodegradable MoO x @MB incorporated hydrogel as light-activated dressing for rapid and safe bacteria eradication and wound healing. RSC Adv 2022; 12:8862-8877. [PMID: 35424847 PMCID: PMC8985166 DOI: 10.1039/d2ra00963c] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 03/07/2022] [Indexed: 11/24/2022] Open
Abstract
Wounds infected with drug-resistant bacteria are hard to treat, which remains a serious problem in clinical practice. An innovative strategy for treating wound infections is thus imperative. Herein, we describe the construction of a nanocomposite from biocompatible poly(vinyl alcohol) (PVA)/polyethylene glycol (PEG) hydrogel loaded biodegradable MoO x nanoparticles (NPs) and photosensitizer methylene blue (MB), denoted as MoO x @MB-hy. By incorporating MoO x @MB NPs, the nanocomposite hydrogel can act as a photoactivated wound dressing for near-infrared-II 1064 nm and 660 nm laser synergetic photothermal-photodynamic therapy (PTT-PDT). The key to PTT-induced heat becomes the most controllable release of MB from MoO x @MB-hy to produce more 1O2 under 660 nm irradiation. Importantly, MoO x @MB-hy can consume glutathione (GSH) and trap bacteria nearer to the distance limit of ROS damage to achieve a self-migration-enhanced accumulation of reactive oxygen species (ROS), thereby conquering the intrinsic shortcomings of short diffusion distance and lifetime of ROS. Consequently, MoO x @MB-hy has high antibacterial efficiencies of 99.28% and 99.16% against Ampr E. coli and B. subtilis within 15 min. Moreover, the light-activated strategy can rapidly promote healing in wounds infected by drug-resistant bacteria. This work paves a way to design a novel nanocomposite hydrogel dressing for safe and highly-efficient antibacterial therapy.
Collapse
Affiliation(s)
- Yifan Wang
- College of Pharmacy, School of Basic Medicine, Ningxia Medical University Yinchuan Ningxia 750004 China
| | - Huiqin Yao
- College of Pharmacy, School of Basic Medicine, Ningxia Medical University Yinchuan Ningxia 750004 China
| | - Yan Zu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, National Center for Nanoscience and Technology, Chinese Academy of Sciences Beijing 100049 China
| | - Wenyan Yin
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, National Center for Nanoscience and Technology, Chinese Academy of Sciences Beijing 100049 China
| |
Collapse
|
12
|
Chen L, Tu N, Wei Q, Liu T, Li C, Wang W, Li J, Lu H. Inhibition of cold‐welding and adhesive wear occurring on surface of the 6061 aluminum alloy by graphene oxide/polyethylene glycol composite water‐based lubricant. SURF INTERFACE ANAL 2021. [DOI: 10.1002/sia.7044] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Lu Chen
- Group of Mechanical and Biomedical Engineering, Xi'an Key Laboratory of Modern Intelligent Textile Equipment, College of Mechanical & Electronic Engineering Xi'an Polytechnic University Xi'an China
| | - Nan Tu
- Group of Mechanical and Biomedical Engineering, Xi'an Key Laboratory of Modern Intelligent Textile Equipment, College of Mechanical & Electronic Engineering Xi'an Polytechnic University Xi'an China
| | - Qianyang Wei
- Shaoxing Xiangu Textile Co., Ltd. Shaoxing China
| | - Tao Liu
- Group of Mechanical and Biomedical Engineering, Xi'an Key Laboratory of Modern Intelligent Textile Equipment, College of Mechanical & Electronic Engineering Xi'an Polytechnic University Xi'an China
| | - Chengzhi Li
- Group of Mechanical and Biomedical Engineering, Xi'an Key Laboratory of Modern Intelligent Textile Equipment, College of Mechanical & Electronic Engineering Xi'an Polytechnic University Xi'an China
| | - Wenbo Wang
- College of Chemistry and Chemical Engineering Inner Mongolia University Hohhot China
| | - Jianhui Li
- Chemistry and Chemical Engineering Guangdong Laboratory Shantou China
| | - Hailin Lu
- Group of Mechanical and Biomedical Engineering, Xi'an Key Laboratory of Modern Intelligent Textile Equipment, College of Mechanical & Electronic Engineering Xi'an Polytechnic University Xi'an China
- Taizhou Medical New & Hi‐tech Industrial Development Zone Taizhou China
| |
Collapse
|