1
|
Zhang C, Tan R, Zhou X, Wang R, Wang X, Ma R, Chu F, Li Y, Yin T, Liu Z. Transcranial Magneto-Acoustic Stimulation Protects Synaptic Rehabilitation from Amyloid-Beta Plaques via Regulation of Microglial Functions. Int J Mol Sci 2024; 25:4651. [PMID: 38731870 PMCID: PMC11083601 DOI: 10.3390/ijms25094651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 04/03/2024] [Accepted: 04/20/2024] [Indexed: 05/13/2024] Open
Abstract
Transcranial magneto-acoustic stimulation (TMAS), which is characterized by high spatiotemporal resolution and high penetrability, is a non-invasive neuromodulation technology based on the magnetic-acoustic coupling effect. To reveal the effects of TMAS treatment on amyloid-beta (Aβ) plaque and synaptic plasticity in Alzheimer's disease, we conducted a comparative analysis of TMAS and transcranial ultrasound stimulation (TUS) based on acoustic effects in 5xFAD mice and BV2 microglia cells. We found that the TMAS-TUS treatment effectively reduced amyloid plaque loads and plaque-associated neurotoxicity. Additionally, TMAS-TUS treatment ameliorated impairments in long-term memory formation and long-term potentiation. Moreover, TMAS-TUS treatment stimulated microglial proliferation and migration while enhancing the phagocytosis and clearance of Aβ. In 5xFAD mice with induced microglial exhaustion, TMAS-TUS treatment-mediated Aβ plaque reduction, synaptic rehabilitation improvement, and the increase in phospho-AKT levels were diminished. Overall, our study highlights that stimulation of hippocampal microglia by TMAS treatment can induce anti-cognitive impairment effects via PI3K-AKT signaling, providing hope for the development of new strategies for an adjuvant therapy for Alzheimer's disease.
Collapse
Affiliation(s)
- Chunlan Zhang
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Ruxin Tan
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Xiaoqing Zhou
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Ruru Wang
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Xin Wang
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Ren Ma
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
- Tianjin Institutes of Health Science, Tianjin 301600, China
| | - Fangxuan Chu
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Ying Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Tao Yin
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| | - Zhipeng Liu
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, 236# Baidi Road, Tianjin 300192, China; (C.Z.); (R.T.); (X.Z.); (R.W.); (X.W.); (R.M.); (F.C.); (T.Y.)
| |
Collapse
|
2
|
Gmitrov J. Carotid Baroreceptor Magnetic Activation and Beat‐to‐Beat Blood Pressure Variability, Implications to Treat Abrupt Blood Pressure Elevation in Labile Hypertension. Bioelectromagnetics 2022; 43:413-425. [DOI: 10.1002/bem.22425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 07/20/2022] [Accepted: 09/10/2022] [Indexed: 11/21/2022]
Affiliation(s)
- Juraj Gmitrov
- Diabetology Clinic Krompachy Hospital, Agel SK Inc. Krompachy Slovakia
| |
Collapse
|
3
|
Mayrovitz HN, Maqsood R, Tawakalzada AS. Do Magnetic Fields Have a Place in Treating Vascular Complications in Diabetes? Cureus 2022; 14:e24883. [PMID: 35698680 PMCID: PMC9184174 DOI: 10.7759/cureus.24883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 05/09/2022] [Indexed: 11/18/2022] Open
Abstract
The use of electromagnetic field therapy (EMFT) is a non-invasive, potential alternative or complementary choice in the treatment of wounds, chronic pain, neuropathy, and other medical conditions, including tissue repair and cell proliferation. Static magnetic fields (SMFs) have been reported to increase microcirculatory blood flow by mediating vasodilation via nitric oxide. Studies report that SMF exposure causes homeostatic, normalizing effects on the vascular tone that may have beneficial effects in situations where tissue perfusion is limited, such as may be present in diabetes. Pulsed electromagnetic fields (PEMFs) have also shown promise in treating diabetic wounds by improving wound healing rates and other attributes. Our purpose was to critically review prior applications of EMFT for relevancy and effectiveness in treating diabetic complications. The goal was to provide information to allow for informed decisions on the possible use of these modalities in the treatment of persons with diabetic complications. The focus was on the following major areas: wound healing, neuropathy, blood glucose control, blood flow, inflammation and oxidative stress.
Collapse
|
4
|
Mayrovitz HN, Astudillo A, Shams E. Finger skin blood perfusion during exposure of ulnar and median nerves to the static magnetic field of a rare-earth magnet: A randomized pilot study. Electromagn Biol Med 2020; 40:1-10. [PMID: 33283550 DOI: 10.1080/15368378.2020.1856682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
This pilot study's goal was to investigate the impacts of static magnetic fields (SMF) on finger skin blood perfusion (SBP) when exposing the ulnar artery and ulnar and medial nerves to a rare earth concentric magnet for 30 minutes. Control SBP was measured in 4th fingers of adults (n = 12, age 26.0 ± 1.4 years) for 15 minutes using laser-Doppler. Then, active-magnets were placed over one arm's ulnar and median nerves at the wrist and sham-magnets placed at corresponding sites on the other arm. Devices were randomly assigned and placed by an investigator "blinded" to device type. The maximum SMF perpendicular to skin was 0.28 T measured 2 mm from magnet surface. The tangential field at this distance was 0.20 T. SBP was analyzed and tested for differential effects attributable to magnets compared to shams in each of the 5-minute intervals over the full 45-minute experiment. Results showed no statistically significant difference between SBP measured on the magnet-treated side compared to the sham side. Magnet and sham side SBP values (mean ± SEM, arbitrary units) prior to device placement were 0.568 ± 0.128 vs. 0.644 ± 0.115, p = .859 and during device placement were 0.627 ± 0.135 vs. 0.645 ± 0.117, p = .857. In conclusion, these findings have failed to uncover any significant effects of the static magnetic field on skin blood perfusion in the young healthy adult population evaluated. Its potential for altering SBP in more mature persons or those with underlying conditions affecting blood flow has not been evaluated but represents the next target of research inquiry. ClinicalTrials.gov registration number is NCT04539704.
Collapse
Affiliation(s)
- Harvey N Mayrovitz
- Dr. Kiran C. Patel College of Allopathic Medicine, Nova Southeastern University , Ft. Lauderdale, FL, USA
| | - Andrea Astudillo
- Dr. Kiran C. Patel College of Osteopathic Medicine, Nova Southeastern University , Ft. Lauderdale, FL, USA
| | - Elham Shams
- Dr. Kiran C. Patel College of Osteopathic Medicine, Nova Southeastern University , Ft. Lauderdale, FL, USA
| |
Collapse
|