1
|
Mokhtari B, Nematollahi D, Salehzadeh H. Electrochemical simultaneous determination of nifedipine and its main metabolite dehydronifedipine using MWCNT modified glassy carbon electrode. J Mol Liq 2018. [DOI: 10.1016/j.molliq.2018.05.082] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
2
|
Filgueira GCDO, Filgueira OAS, Carvalho DM, Marques MP, Moisés ECD, Duarte G, Lanchote VL, Cavalli RC. Analysis of nifedipine in human plasma and amniotic fluid by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics in hypertensive pregnant women. J Chromatogr B Analyt Technol Biomed Life Sci 2015; 993-994:20-5. [PMID: 25984962 DOI: 10.1016/j.jchromb.2015.04.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2015] [Revised: 04/16/2015] [Accepted: 04/20/2015] [Indexed: 11/19/2022]
Abstract
Nifedipine is a dihydropyridine calcium channel blocker used for the treatment of hypertension in pregnant women. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of nifedipine in human plasma and amniotic fluid. Separation of nifedipine and nitrendipine (IS) was performed using a LiChroCART(®) RP-Select B column and a mixture of water:acetonitrile:glacial acetic acid (30:70:0.5 v/v) as the mobile phase. Aliquots of 500μL of biological samples were extracted at pH 13 using dichloromethane:n-pentane (3:7 v/v). The validated method was applied to a study of the pharmacokinetics of nifedipine in human plasma and amniotic fluid samples collected up to 12h after administration of the last slow-release nifedipine (20mg/12h) dose to 12 hypertensive pregnant women. The estimated pharmacokinetic parameters of nifedipine showed a mean AUC(0-12) of 250.2ngh/mL, ClT/F of 89.2L/h, Vd/F of 600.0L and t1/2 5.1h. The mean amniotic fluid/plasma concentration ratio was 0.05. The methods proved to be highly sensitive by showing a lower quantification limit of 0.1ng/mL for both matrices. And this study reports for the first time the complete development and validation of the method to quantify nifedipine in amniotic fluid using LC-MS-MS.
Collapse
Affiliation(s)
| | - Osmany Alberto Silva Filgueira
- Department of Obstetrics and Gynecology, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Daniela Miarelli Carvalho
- Department of Obstetrics and Gynecology, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Maria Paula Marques
- Department of Clinical, Toxicologic and Bromatologic Analyses, Faculty of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Elaine Christine Dantas Moisés
- Department of Obstetrics and Gynecology, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Geraldo Duarte
- Department of Obstetrics and Gynecology, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Vera Lucia Lanchote
- Department of Clinical, Toxicologic and Bromatologic Analyses, Faculty of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Ricardo Carvalho Cavalli
- Department of Obstetrics and Gynecology, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
| |
Collapse
|
3
|
Patel DP, Sharma P, Sanyal M, Singhal P, Shrivastav PS. Highly sensitive and rapid ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of nifedipine in human plasma and its application to a bioequivalence study. Biomed Chromatogr 2012; 26:1509-18. [DOI: 10.1002/bmc.2725] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2011] [Accepted: 01/30/2012] [Indexed: 01/13/2023]
Affiliation(s)
- Daxesh P. Patel
- Department of Chemistry, School of Sciences; Gujarat University; Navrangpura; Ahmedabad; 380009; Gujarat; India
| | - Primal Sharma
- Department of Chemistry, School of Sciences; Gujarat University; Navrangpura; Ahmedabad; 380009; Gujarat; India
| | - Mallika Sanyal
- Department of Chemistry; St. Xavier's College; Navrangpura; Ahmedabad; 380009; Gujarat; India
| | - Puran Singhal
- Bioanalytical Research Department; Veeda Clinical Research; Ambawadi; Ahmedabad; 380015; Gujarat; India
| | - Pranav S. Shrivastav
- Department of Chemistry, School of Sciences; Gujarat University; Navrangpura; Ahmedabad; 380009; Gujarat; India
| |
Collapse
|
4
|
Wang D, Jiang K, Yang S, Qin F, Lu X, Li F. Determination of nifedipine in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:1827-32. [PMID: 21601538 DOI: 10.1016/j.jchromb.2011.04.034] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2011] [Revised: 04/24/2011] [Accepted: 04/26/2011] [Indexed: 11/25/2022]
Abstract
A fast, sensitive and selective ultra performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method was developed for the determination of nifedipine in human plasma. Nitrendipine was used as the internal standard. The sample preparation employed liquid-liquid extraction with a mixture of n-hexane-diethyl ether (1:3, v/v). Chromatographic separation was performed on an ACQUITY UPLC™ BEH C(18) column. The mobile phase was composed of acetonitrile-10 mmol/L ammonium acetate (75:25, v/v) with a flow rate of 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. A high throughput was achieved with a run time of 1.4 min per sample. The linear calibration curves were obtained in the concentration range of 0.104-52.0 ng/mL (r(2)≥ 0.99) with a lower limit of quantification (LLOQ) of 0.104 ng/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were below 15% and the accuracy (relative error, RE) was -4.0% to 6.2% at three quality control levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of nifedipine sustained-release tablet in healthy male volunteers.
Collapse
Affiliation(s)
- Dan Wang
- Department of Analytical Chemistry, Shenyang Pharmaceutical University, 103# Wenhua Road, Shenyang 110016, PR China
| | | | | | | | | | | |
Collapse
|
5
|
Wang XD, Li JL, Lu Y, Chen X, Huang M, Chowbay B, Zhou SF. Rapid and simultaneous determination of nifedipine and dehydronifedipine in human plasma by liquid chromatography-tandem mass spectrometry: Application to a clinical herb-drug interaction study. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 852:534-44. [PMID: 17339138 DOI: 10.1016/j.jchromb.2007.02.026] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2006] [Revised: 02/01/2007] [Accepted: 02/09/2007] [Indexed: 01/03/2023]
Abstract
Nifedipine (NIF), a calcium channel antagonist, is metabolized primarily by cytochrome P450 (CYP3A4) to dehydronifedipine (DNIF). As such, NIF is often used as a probe drug for determining CYP3A4 activity in human studies. A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine NIF and DNIF in human plasma using nitrendipine as the internal standard (IS). After extraction of the plasma samples by ether-n-hexane (3:1, v/v), NIF, DNIF and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C(18) column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of approximately 2.5 min and linear calibration curves over the concentrations of 0.5-100 ng/mL for NIF and DNIF. The recoveries of the one-step liquid extraction method were 81.3-89.1% for NIF and 71.6-80.4% for DNIF. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for both analytes. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL. The validated LC/MS/MS method has been successfully used to study pharmacokinetic interactions of NIF with the herbal antidepressant St. John's wort in healthy volunteers. These results indicated that the developed LC/MS/MS method was efficient with a significantly shorter running time (2.5 min) for NIF and DNIF compared to those methods previously reported in the literature. The presented LC/MS/MS method had acceptable accuracy, precision and sensitivity and was used in a clinical pharmacokinetic interaction study of NIF with St. John's wort, a known herbal inducer of CYP3A4. St. John's wort was shown to induce NIF metabolism with increased plasma concentrations of DNIF.
Collapse
Affiliation(s)
- Xue-Ding Wang
- Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, China
| | | | | | | | | | | | | |
Collapse
|
6
|
Niopas I, Daftsios AC. Determination of nifedipine in human plasma by solid-phase extraction and high-performance liquid chromatography: validation and application to pharmacokinetic studies. J Pharm Biomed Anal 2003; 32:1213-8. [PMID: 12907265 DOI: 10.1016/s0731-7085(03)00162-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Nifedipine, a dihydropyridine calcium channel antagonist, is widely used in the treatment of hypertension and other cardiovascular disorders. A simple, rapid, sensitive, precise and accurate HPLC method, using solid-phase extraction, for the quantitation of nifedipine in human plasma was developed and validated. The calibration graphs were linear in the 5-400 ng/ml concentration range (r>0.999). Recovery for nifedipine was greater than 93.9% and for internal standard nitrendipine was 96.1%. Intra-day and inter-day precision ranged from 1.4 to 4.2 and 3.9 to 5.6%, respectively. Intra-day and inter-day accuracy was ranged from 94.5 to 98.0 and 93.1 to 98.0%, respectively. The method was not interfered with by other plasma components and was applied for the determination of nifedipine in pharmacokinetic study after single oral administration of 10 mg nifedipine to 18 healthy male subjects.
Collapse
Affiliation(s)
- Ioannis Niopas
- Department of Pharmacy, School of Health Sciences, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
| | | |
Collapse
|
7
|
Ghoneim MM, Tawfik A, Khashaba PY. Cathodic adsorptive stripping square-wave voltammetric determination of nifedipine drug in bulk, pharmaceutical formulation and human serum. Anal Bioanal Chem 2003; 375:369-75. [PMID: 12589501 DOI: 10.1007/s00216-002-1703-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2002] [Revised: 11/03/2002] [Accepted: 11/14/2002] [Indexed: 11/29/2022]
Abstract
Nifedipine is a calcium-channel antagonist drug used in the management of angina pectoris and hypertension through inhibition of calcium influx. A fully validated sensitive cathodic adsorptive stripping square-wave voltammetry procedure was optimized for the determination of the drug at trace levels. The procedure was based on the reduction of the nitrophenyl group after the interfacial accumulation of the drug onto a hanging mercury drop electrode in Britton-Robinson buffer of pH 11.0. The optimal conditions of the procedure were found to be: accumulation potential=-0.9 V vs. Ag/AgCl/KCl(s)), accumulation time=30 s, scan increment=10 mV, pulse amplitude=50 mV and frequency=120 Hz. Under these conditions, a well-defined peak was obtained; its peak current showed a linear dependence on drug concentration in the range of 2x10(-9)-2x10(-7) mol L(-1) bulk nifedipine. The mean recoveries based on eight replicate measurements for 1x10(-8) and 5x10(-8) mol L(-1) bulk nifedipine solutions were 98.46+/-0.86% and 98.23+/-0.92%, respectively. A detection limit of 3.42x10(-10) mol L(-1) bulk nifedipine was achieved. The procedure was successfully applied for assay of the drug in tablets and spiked human serum with mean recoveries of 101.95+/-1.42% and 98.70+/-0.63%, respectively. The limit of detection of the drug in spiked human serum was found to be 3.90x10(-10) mol L(-1).
Collapse
Affiliation(s)
- M M Ghoneim
- Department of Chemistry, Faculty of Science, Tanta University, Egypt.
| | | | | |
Collapse
|
8
|
Abou-Auda HS, Najjar TA, Al-Khamis KI, Al-Hadiya BM, Ghilzai NM, Al-Fawzan NF. Liquid chromatographic assay of nifedipine in human plasma and its application to pharmacokinetic studies. J Pharm Biomed Anal 2000; 22:241-9. [PMID: 10719906 DOI: 10.1016/s0731-7085(99)00258-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A highly sensitive, selective and reproducible reversed-phase high-performance liquid chromatographic method has been developed for the determination of nifedipine in human plasma with minimum sample preparation. The method is sensitive to 3 ng/ml in plasma, with acceptable within- and between-day reproducibilities and linearity (r2 > 0.99) over a concentration range from 10-200 ng/ml. Acidified plasma samples were extracted using diethyether containing diazepam as internal standard and chromatographic separation was accomplished on C18 column using a mobile phase consisting of acetonitrile, methanol and water (35:17:48, v/v). The within-day precision ranged from 2.22 to 4.64% and accuracy ranged from 102.4-106.4%. The day-to-day precision ranged from 2.34-7.07% and accuracy from 95.1-100.1%. The relative recoveries of nifedipine from plasma ranged from 91.0-107.3% whereas extraction recoveries were 88.6-93.3%. Following eight 6-week freeze-thaw cycles, nifedipine in plasma samples proved to be stable with accuracy ranging from 0.64 to 3.0% and precision ranging from 3.6 to 4.15%. Nifedipine was also found to be photostable for at least 120 min in plasma, 30 min in blood and for 60 min in aqueous solutions after exposure to light. The method is sensitive and reliable for pharmacokinetic studies and therapeutic drug monitoring of nifedipine in humans after the oral administration of immediate-release capsules and sustained-release tablets to five healthy subjects.
Collapse
Affiliation(s)
- H S Abou-Auda
- Department of Clinical Pharmacy, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia.
| | | | | | | | | | | |
Collapse
|
9
|
Streel B, Zimmer C, Sibenaler R, Ceccato A. Simultaneous determination of nifedipine and dehydronifedipine in human plasma by liquid chromatography-tandem mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1998; 720:119-28. [PMID: 9892074 DOI: 10.1016/s0378-4347(98)00423-x] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC-MS-MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 microm). The mobile phase consisted of methanol-50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode. The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95+/-2% and 95+/-4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5-100 ng/ml concentration range for the two analytes (r2 = 0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2-4.7% for the metabolite. The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.
Collapse
Affiliation(s)
- B Streel
- S.M.B. Laboratories R&D (Galephar), Brussels, Belgium
| | | | | | | |
Collapse
|
10
|
Horváth V, Hrabéczy-Páll A, Niegreisz Z, Kocsi E, Horvai G, Gödörházy L, Tolokán A, Klebovich I, Balogh-Nemes K. Sensitive high-performance liquid chromatographic determination of nifedipine in dog plasma using an automated sample preparation system with laboratory robot. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL APPLICATIONS 1996; 686:211-9. [PMID: 8971602 DOI: 10.1016/s0378-4347(96)00216-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Nifedipine, a calcium-channel blocking drug was analysed in dog plasma after oral dosing with two different formulations. Sample preparation was automated with a laboratory robot. Quantitative determination of the drug was performed on a reversed-phase HPLC system with electrochemical detection (ED) using an internal standard. Validation of the analytical method showed that the system is well suited for pharmacokinetic studies on dogs. The assay was linear in the range 1-50 ng/ml. Inter-day and intra-day variability were between 6.43-18.15% C.V. and 1.57-5.53% C.V., respectively.
Collapse
Affiliation(s)
- V Horváth
- Technical University of Budapest, Institute for General and Analytical Chemistry, Hungary
| | | | | | | | | | | | | | | | | |
Collapse
|