1
|
Hu J, Ma Y, Wu S. Synthesis and application of optically stable red fluorescent carbon dots for sensitive and selective detection of ceftazidime. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 327:125341. [PMID: 39488909 DOI: 10.1016/j.saa.2024.125341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 10/10/2024] [Accepted: 10/24/2024] [Indexed: 11/05/2024]
Abstract
This study reports the successful synthesis of optically stable red-emitting carbon dots (R-CDs) through a solvothermal method, using glycine as the carbon source and o-phenylenediamine as the nitrogen-doping agent. The R-CDs exhibit long-wavelength emission characteristics with optimal excitation and emission wavelengths of 533 nm and 600 nm, respectively, and a quantum yield of 26.7 %. The results demonstrate that R-CDs possess excellent salt resistance and photostability. The R-CDs display bright fluorescence emission and show a sensitive response to ceftazidime (CF). Leveraging these properties, a fluorescent probe based on R-CDs was developed for the sensitive determination of CF. The fluorescence quenching intensity of this system exhibits a good linear relationship with CF concentration in the range of 0-0.7 mmol/L. The linear equation is (F0-F)/F0=0.9564CCF(mmol/L)+0.0089, with a linear correlation coefficient (R2) of 0.9945. The detection limit is 4.9 μmol/L, with recovery rates ranging from 94.2 % to 100.5 % and relative standard deviations between 2.2 % and 3.2 %. This work provides a theoretical basis for the detection of CF using red-emitting carbon dots and demonstrates promising potential for practical applications.
Collapse
Affiliation(s)
- Jing Hu
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu 610066, China
| | - Yanshun Ma
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu 610066, China.
| | - Shaogui Wu
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu 610066, China
| |
Collapse
|
2
|
Lv J, Wu Q, Li S, Yi H, Xie F. Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spots. J Pharm Biomed Anal 2024; 239:115928. [PMID: 38134705 DOI: 10.1016/j.jpba.2023.115928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 12/13/2023] [Accepted: 12/16/2023] [Indexed: 12/24/2023]
Abstract
Bacterial infection is a leading cause of neonatal death. Ceftazidime, commonly used for neonatal infections, is often used off-label. Blood sampling limits pharmacokinetic (PK) studies in neonatal patients. The dried blood spots (DBS) are a potential matrix for microsampling. Herein, we describe an ultra-performance liquid chromatography with a photodiode array (UPLC-PDA) to determine ceftazidime in DBS from neonatal patients in support of pharmacokinetic studies. The Capitainer® device-based DBS samples containing 10 µL blood were extracted in 70% methanol/water (v/v) with acetaminophen as the internal standard (IS). The extraction process was carried out at 20 °C using a block bath shaker at 1000 rpm for 30 min. The extracted ceftazidime was subsequently eluted through an Acquity UPLC HSS T3 column (2.1 × 50 mm, 1.8 µm). Elution was achieved using a water (containing 0.1% trifluoroacetic acid)/acetonitrile linear gradient at a flow rate of 0.5 mL/min, and the analytical time was 3.2 min. The PDA detection wavelength was set at 259 nm. The method underwent thorough validation following the recommendation of the European Bioanalysis Forum (EBF) and the bioanalytical guideline established by the European Medicines Agency (EMA). No interfering peaks were detected at the retention times of ceftazidime and IS. The ceftazidime exhibited a quantification range spanning from 0.5 to 200 µg/mL, and the assay demonstrated good accuracy (intra/inter-assay ranging from 90.1% to 104.8%) and precision (intra/inter-assay coefficient of variations ranging from 4.8% to 11.7%). The method's applicability was demonstrated by analyzing clinical DBS samples collected from neonatal patients.
Collapse
Affiliation(s)
- Jianmei Lv
- Division of Biopharmaceutics and Pharmacokinetics, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Qiping Wu
- Division of Biopharmaceutics and Pharmacokinetics, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Sanwang Li
- Department of Pharmacy, The Second Xiangya Hospital, Central South University, Changsha, China; Institute of Clinical Pharmacy, Central South University, Changsha, China
| | - Hanxi Yi
- Department of Pathology, School of Basic Medical Science, Central South University, Changsha, China
| | - Feifan Xie
- Division of Biopharmaceutics and Pharmacokinetics, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China.
| |
Collapse
|
3
|
Al-Kadhi NS, Mohamed MA, Ahmed HA, Nassar HF. Facile synthesis and eco-friendly analytical methods for concurrent estimation of selected pharmaceutical drugs in their solutions: application to quality by design, lean six sigma, and stability studies. BMC Chem 2023; 17:136. [PMID: 37817268 PMCID: PMC10566104 DOI: 10.1186/s13065-023-01028-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 08/29/2023] [Indexed: 10/12/2023] Open
Abstract
Economical, highly robust, selective, precise, and eco-friendly RP-UPLC and spectrophotometric methods were developed and validated for the concurrent estimation of selected pharmaceutical drugs represented in ceftazidime (CFZ) and pyridine (PYD) in their solutions using Agilent Zorbax SB-C18 RRHD (50 × 2.1 mm, 1.8 μm) column at flow rate 0.3 mL/min with wavelength 254 nm. Box-Behnken design (BBD) established Response surface methodology (RSM) to achieve the optimum chromatographic condition with minimal trials conducted. Three independent variables specifically acetonitrile ratio 60-70%, pH 3-7, and temperature 25-35 °C were implemented to evaluate the influences of these variables on the responses as resolution and retention time. Desirability and overlay plots were carried out to adjust the optimal condition that achieved the shortest retention time of less than 2 min and desired resolution of more than 1.5 using a mobile phase consisting of acetonitrile: purified water (70:30, v/v) at pH 5.0 adjusted by 0.1% orthophosphoric acid with the column oven temperature 30 °C and column void volume 0.46 mL. Mean centering of ratio spectra (MCR) and ratio subtraction (RS) methods were effectively applied to resolve drugs' spectral superposition at 220 nm, 255.4 nm, 260.3 nm, and 254.6 nm for CFZ and PYD, respectively. Linearity range was accomplished for UPLC, MCR, and RS methods over the concentration range of 2-100, 1-50,3-30 and 5-30 µg/mL for CFZ and PYD, respectively with correlation coefficient > 0.999 and good recovery results within 98-102%. Six Sigma methodology was achieved using the process capability index (Cpk) to compare the suggested and USP methods showing that both are highly capable with Cpk > 1.33. The proposed method was successfully validated depending on ICH guidelines and ANOVA results and applied for the accelerated stability study.
Collapse
Affiliation(s)
- Nada S Al-Kadhi
- Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabia
| | | | - Hoda A Ahmed
- Department of Chemistry, Faculty of Science, Cairo University, Cairo, 12613, Egypt
| | - Hossam F Nassar
- Environmental Science and Industrial Development Department, Faculty of Post Graduate Studies for Advanced Sciences, Beni-Suef University, Beni‑Suef, Egypt.
| |
Collapse
|
4
|
Nguyen T, Spriet I, Quintens C, Thi Thanh Ha P, Van Schepdael A, Adams E. Simultaneous determination of ceftazidime and pyridine in human plasma by LC-UV. J Pharm Biomed Anal 2023; 228:115319. [PMID: 36858005 DOI: 10.1016/j.jpba.2023.115319] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 02/03/2023] [Accepted: 02/24/2023] [Indexed: 02/27/2023]
Abstract
A sensitive, accurate and precise liquid chromatography (LC) method for the simultaneous determination of ceftazidime and pyridine in human plasma has been developed and validated. Acetonitrile (ACN) was employed to precipitate the proteins in the plasma samples. Chromatographic separation was performed with a Kinetex® C18 (150 mm × 3 mm, 2.6 µm) column with gradient elution. Ammonium formate 20 mM and ACN were mixed in a ratio of 98:2 (v/v) for mobile phase A and 85:15 (v/v) for mobile phase B. Both were adjusted to pH 4.5 with formic acid. The flow rate was 0.4 mL/min. UV detection was performed at 254 nm. Calibration curves were linear in the range from 0.3 to 225 μg/mL for ceftazidime and from 0.2 to 10 μg/mL for pyridine with correlation coefficients ≥ 0.999. Within- and between-run precision and accuracy were satisfactory with coefficients of variation (CV) ≤ 8.0% and deviations ≤ 7.0%, respectively. The method fulfilled all validation criteria prescribed by the European Medicines Agency guidelines. Next, it has been used successfully to analyze plasma samples of patients who received ceftazidime under intermittent and continuous administration. With intermittent administration, the concentration of the antibiotics reached a peak and then dropped quickly, which may be below the minimal inhibitory concentration (MIC). With continuous administration, the concentration of the antibiotics remained stable over 24 h, certainly above the MIC. Although the same tendency in ceftazidime concentration changes over time was observed, a difference in concentration amongst the patients was noticeable. The concentration of pyridine in plasma was negligible.
Collapse
Affiliation(s)
- Tam Nguyen
- KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Isabel Spriet
- Hospital Pharmacy Department, University Hospitals Leuven, Herestraat 49, 3000 Leuven, Belgium
| | - Charlotte Quintens
- Hospital Pharmacy Department, University Hospitals Leuven, Herestraat 49, 3000 Leuven, Belgium
| | - Pham Thi Thanh Ha
- Hanoi University of Pharmacy, Analytical Chemistry and Toxicology, 13-15 Le Thanh Tong, Hoan Kiem, Hanoi, Viet Nam
| | - Ann Van Schepdael
- KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Erwin Adams
- KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium.
| |
Collapse
|
5
|
Zenkevich IG, Nikitina DA, Kushakova AS. Processing and Interpretation of Analytical Data with a High Degree of Uncertainty. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822090143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
6
|
Paimard G, Shamsipur M, Gholivand MB. A three-dimensional hybrid of CdS quantum dots/chitosan/reduced graphene oxide-based sensor for the amperometric detection of ceftazidime. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02494-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
7
|
Wang Q, Zheng Y, Liu L, Ji P, Jiang W, Zhao J, Ren J, Yang L. Simultaneous Determination of Ceftazidime and Avibactam in Human Plasma and Cerebrospinal Fluid by High-Performance Liquid Chromatography – Tandem Mass Spectrometry (HPLC-MS/MS). ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2105859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Qinhui Wang
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Yao Zheng
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Linna Liu
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Peigang Ji
- Department of Thoracic Surgery, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Wei Jiang
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Jun Zhao
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Jing Ren
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| | - Le Yang
- Department of Pharmacy, The Second Affiliated Hospital of Air Force Medical University, Xi’an, China
| |
Collapse
|
8
|
Tůma P, Jaček M, Sommerová B, Dlouhý P, Jarošíková R, Husáková J, Wosková V, Fejfarová V. Monitoring of amoxicilline and ceftazidime in the microdialysate of diabetic foot and serum by capillary electrophoresis with contactless conductivity detection. Electrophoresis 2022; 43:1129-1139. [PMID: 35072285 DOI: 10.1002/elps.202100366] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/17/2021] [Accepted: 12/23/2021] [Indexed: 11/11/2022]
Abstract
Determination of the broad-spectrum antibiotics amoxicilline (AMX) and ceftazidime (CTZ) in blood serum and microdialysates of the subcutaneous tissue of the lower limbs is performed using CE with contactless conductivity detection (C4 D). Baseline separation of AMX is achieved in 0.5 M acetic acid as the background electrolyte and separation of CTZ in 3.2 M acetic acid with addition of 13% v/v methanol. The CE-C4 D determination is performed in a 25 µm capillary with suppression of the EOF using INST-coating on an effective length of 18 cm and the attained migration time is 4.2 min for AMX and 4.4 min for CTZ. The analysis was performed using 20 µl of serum and 15 µl of microdialysate, treated by the addition of acetonitrile in a ratio of 1/3 v/v and the sample is injected into the capillary using the large volume sample stacking technique. The LOQ attained in the microdialysate is 148 ng/ml for AMX and 339 ng/ml for CTZ, and in serum 143 ng/ml for AMX and 318 ng/ml for CTZ. The CE-C4 D method is employed for monitoring the passage of AMX and CTZ from the blood circulatory system into the subcutaneous tissue at the sites of diabetic ulceration in patients suffering from diabetic foot syndrome and also for measuring the pharmacokinetics following intravenous application of bolus antibiotic doses.
Collapse
Affiliation(s)
- Petr Tůma
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Martin Jaček
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Blanka Sommerová
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Pavel Dlouhý
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Radka Jarošíková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| | - Jitka Husáková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| | - Veronika Wosková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| | - Vladimíra Fejfarová
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| |
Collapse
|
9
|
Cheng Y, Chen M, Zhang B, Lin H, Li X, Cai Y, Zhang H, Que W, Liu M, Qiu H. Rapid, simple, and economical LC-MS/MS method for simultaneous determination of ceftazidime and avibactam in human plasma and its application in therapeutic drug monitoring. J Clin Pharm Ther 2022; 47:1426-1437. [PMID: 35633089 DOI: 10.1111/jcpt.13693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 04/11/2022] [Accepted: 05/04/2022] [Indexed: 11/29/2022]
Abstract
WHAT IS KNOWN AND OBJECTIVE Carbapenem-resistant Gram-negative bacterial pathogens continue to threaten public health. Avibactam (AVI), a novel non-β-lactam β-lactamase inhibitor, has been approved for use with ceftazidime (CAZ) mainly against carbapenem-resistant Enterobacteriaceae. Therapeutic drug monitoring (TDM) is urgently needed to optimize dosage regimens to maximize efficacy, minimize toxicity, and delay the emergence of resistance. This study aims to develop and validate a rapid, simple, and economical LC-MS/MS method for simultaneous determination of CAZ/AVI in human plasma. METHODS Samples were processed by simple protein precipitation, and gradient elution strategy was applied to separate CAZ and AVI on a reverse-phase C18 column; with subsequent detection by the mass spectrometer in a positive and negative ion switching mode. Plasma samples from patients were analysed. RESULTS AND DISCUSSION A 4-min run of LC-MS/MS was developed. The precision, trueness, matrix effect, extraction recovery, carry-over, dilution integrity, and stability were all acceptable for a bioanalytical method. The method was successfully applied to the determination of CAZ and AVI in patients, and a considerable PK variability of CAZ/AVI was observed among patients. WHAT IS NEW AND CONCLUSION A robust, rapid, simple, and economical LC-MS/MS method for the simultaneous determination of CAZ and AVI was developed. The considerable PK variability of CAZ/AVI among patients demonstrates the clinical significance of TDM.
Collapse
Affiliation(s)
- Yu Cheng
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China.,College of Pharmacy, Fujian Medical University, Fuzhou, People's Republic of China.,Department of Pharmacy, Shengjing Hospital of China Medical University, Shenyang, People's Republic of China
| | - Maohua Chen
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China
| | - Bingqing Zhang
- College of Pharmacy, Fujian Medical University, Fuzhou, People's Republic of China
| | - Hailin Lin
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China
| | - Xueyong Li
- College of Pharmacy, Fujian Medical University, Fuzhou, People's Republic of China
| | - Yipeng Cai
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China
| | - Hui Zhang
- Department of Critical Care Medicine, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China
| | - Wancai Que
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China
| | - Maobai Liu
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China
| | - Hongqiang Qiu
- Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, People's Republic of China.,College of Pharmacy, Fujian Medical University, Fuzhou, People's Republic of China
| |
Collapse
|