1
|
Masclef J, Prunet J, Schmidt BVKJ. Synthesis of PEG-Polycycloether Block Copolymers: Poloxamer Mimics Containing a Rigid Helical Block. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2310277. [PMID: 38520722 PMCID: PMC11165552 DOI: 10.1002/advs.202310277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 02/23/2024] [Indexed: 03/25/2024]
Abstract
Poloxamers are amphiphilic block copolymers consisting of poly(ethylene glycol) (PEG) and poly(propylene glycol) segments. Their self-assembly and interfacial properties are tied to the relative hydrophilicity and hydrophobicity of each block and can therefore be adjusted by changing block lengths. Here, a series of PEG-polycycloether block copolymers is synthesized that have the same structure as a poloxamer, but they encompass a rigid polycyclic backbone as the hydrophobic block. A variety of polymer structures are synthesized, for example diblock or triblock architectures, with/without olefinic units, atactic or isotactic backbone, and different block lengths. Due to their amphiphilicity, self-assembly into spherical aggregates (diameters ranging from 64 to 132 nm) at low concentrations (critical aggregation concentration as low as 0.04 mg mL-1) is observed in water. Low surface tensions (as low as 26.7 mN m-1) are observed as well as the formation of stable high internal phase emulsions (HIPEs) irrespective of the oil/water ratio. This contrasts with the properties of the commonly used poloxamers P188 or P407 and illustrates the significance of the rigid polycycloether block. These new colloidal properties offer new prospects for applications in emulsion formulations for biomedicine, cosmetics, and the food industry.
Collapse
Affiliation(s)
| | - Joëlle Prunet
- School of Chemistry, Joseph Black BuildingUniversity of GlasgowGlasgowG12 8QQUK
| | | |
Collapse
|
2
|
Wei Z, Xia Y, Su Y, Quan Y, Sun L, Wang S, Zhu F, Chen Z, Tian J, Wang WC, Zhou W, Yu H. Modulating and optimizing Pluronic F-68 concentrations and feeding for intensified perfusion Chinese hamster ovary cell cultures. Biotechnol Prog 2023; 39:e3340. [PMID: 36970759 DOI: 10.1002/btpr.3340] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 02/21/2023] [Accepted: 03/10/2023] [Indexed: 03/29/2023]
Abstract
Perfusion culture is often performed with micro-sparger to fulfill the high oxygen demand from the densified cells. Protective additive Pluronic F-68 (PF-68) is widely used to mitigate the adverse effect in cell viability from micro-sparging. In this study, different PF-68 retention ratio in alternating tangential filtration (ATF) columns was found to be crucial for cell performance of different perfusion culture modes. The PF-68 in the perfusion medium was found retained inside the bioreactor when exchanged through ATF hollow fibers with a small pore size (50 kD). The accumulated PF-68 could provide sufficient protection for cells under micro-sparging. On the other hand, with large-pore-size (0.2 μm) hollow fibers, PF-68 could pass through the ATF filtration membranes with little retention, and consequently led to compromised cell growth. To overcome the defect, a PF-68 feeding strategy was designed and successfully verified on promoting cell growth with different Chinese hamster ovary (CHO) cell lines. With PF-68 feeding, enhancements were observed in both viable cell densities (20%-30%) and productivity (~30%). A threshold PF-68 concentration of 5 g/L for high-density cell culture (up to 100 × 106 cells/mL) was also proposed and verified. The additional PF-68 feeding was not observed to affect product qualities. By designing the PF-68 concentration of perfusion medium to or higher than the threshold level, a similar cell growth enhancement was also achieved. This study systematically investigated the protecting role of PF-68 in intensified CHO cell cultures, shedding a light on the optimization of perfusion cultures through the control of protective additives.
Collapse
Affiliation(s)
- Zhaohui Wei
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Yang Xia
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Yuning Su
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Yufen Quan
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Liuliu Sun
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Shanshan Wang
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Fangjian Zhu
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Zhenzhen Chen
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Jun Tian
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Wei-Chun Wang
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| | - Weichang Zhou
- WuXi Biologics, 299 Fute Zhong Road, Waigaoqiao Free Trade Zone, Shanghai, 200131, China
| | - Haiyang Yu
- Process Development, WuXi Biologics, 108 Meiliang Road, Wuxi, 214092, China
| |
Collapse
|
3
|
Arai T, Sato T, Matsubara T. Effective Cell Transfection in An Ultrasonically Levitated Droplet for Sustainable Technology. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2203576. [PMID: 36026571 PMCID: PMC9596829 DOI: 10.1002/advs.202203576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/17/2022] [Indexed: 06/15/2023]
Abstract
The levitation methodology, which enables us to operate a contactless reaction without a container, is likely to be a revolutionary technology in the fields of chemistry and biology to reduce the plastic waste in life science laboratories. Here, the authors show that plasmid DNA can be effectively transfected into animal cells in a floating droplet of culture medium levitated using ultrasonic standing waves. The data indicate that there is no significant damage to the plasmid and cells during the levitating transfection time, and the transgene expression efficiency and cellular uptake in the droplet are significantly higher than those in the conventional tube, with and without shaking. These results suggest the consolidation of the endocytic uptake pathway into macropinocytosis, indicating that ultrasonic levitation induced a change in cell characteristics. This study suggests that transfection methodology using ultrasonic levitation has the potential to advance the current experimental procedures in the field of cell engineering, in addition to presenting a revolutionary containerless reactor for sustainable technology.
Collapse
Affiliation(s)
- Takahiro Arai
- Department of Biosciences and InformaticsFaculty of Science and TechnologyKeio University3‐14‐1 Hiyoshi, Kohoku‐kuYokohamaKanagawa223–8522Japan
| | - Toshinori Sato
- Department of Biosciences and InformaticsFaculty of Science and TechnologyKeio University3‐14‐1 Hiyoshi, Kohoku‐kuYokohamaKanagawa223–8522Japan
| | - Teruhiko Matsubara
- Department of Biosciences and InformaticsFaculty of Science and TechnologyKeio University3‐14‐1 Hiyoshi, Kohoku‐kuYokohamaKanagawa223–8522Japan
| |
Collapse
|
4
|
Šrom O, Trávníková V, Bláha L, Ciofalo M, Šoóš M. Investigation of poloxamer cell protective ability via shear sensitive aggregates in stirred aerated bioreactor. Biochem Eng J 2022. [DOI: 10.1016/j.bej.2022.108549] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
5
|
Bandyopadhyay A, Kosanam H, Yang RS, Gupta B, Naralakattu N, Pakhale S, Kress J, Richardson D, Ly J. Low-molecular-weight impurity in Poloxamer 188 responsible for atypical cell culture performance for mAb production. J Biotechnol 2022; 351:13-22. [PMID: 35483475 DOI: 10.1016/j.jbiotec.2022.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 04/12/2022] [Accepted: 04/21/2022] [Indexed: 11/26/2022]
Abstract
During a recent manufacturing campaign for a monoclonal antibody using a fed-batch process, poor cell culture performance was observed across two manufacturing sites with similar scales and equipment. Root cause analysis indicated that the poor cell culture performance was linked to the production basal media. Genealogy of the precursor raw materials used in the media revealed that a particular lot of Poloxamer 188 (P188) was the common link to the poor-performing media lots. P188 serves a critical role in protecting cells against shear in cell culture bioprocesses. However, the small-scale studies suggested that the poor cell culture performance was cytostatic in nature rather than being caused due to lack of shear protection. Several P188 lots were tested analytically using SEC-MS and RP-LC-MS methods and a unique low molecular weight species was identified in the suspect lot of poloxamer. The impurity was identified to be polypropylene oxide (PPO), a reaction intermediate in P188 synthesis. Spiking studies with PPO further confirmed its cytostatic nature. This case study highlights yet another scenario where lot-to-lot variability continues to impact bioprocesses and re-emphasizes the need for robust analytical and cell-culture raw material screening methods.
Collapse
Affiliation(s)
- Arpan Bandyopadhyay
- Biologics Process Development and Commercialization, Merck & Co., Inc, Kenilworth, New Jersey 07033, United States
| | - Hari Kosanam
- Vaccines Process Development and Commercialization, Merck & Co., Inc, Westpoint, Pennsylvania 19486, United States
| | - Rong-Sheng Yang
- Analytical Research & Development, Merck & Co., Inc, Kenilworth, New Jersey 07033, United States
| | - Balrina Gupta
- Biologics Upstream Process Development, Merck & Co., Inc, Kenilworth, New Jersey 07033, United States
| | - Naja Naralakattu
- Global Technical Operations - Raw Materials Center of Excellence, Merck & Co., Inc, Westpoint, Pennsylvania 19486, United States
| | - Shital Pakhale
- Biologics Process Development and Commercialization, Merck & Co., Inc, Kenilworth, New Jersey 07033, United States
| | - Jared Kress
- Vaccines Process Development and Commercialization, Merck & Co., Inc, Westpoint, Pennsylvania 19486, United States
| | - Douglas Richardson
- Analytical Research & Development, Merck & Co., Inc, Kenilworth, New Jersey 07033, United States
| | - Jeffrey Ly
- Biologics Process Development and Commercialization, Merck & Co., Inc, Kenilworth, New Jersey 07033, United States
| |
Collapse
|
6
|
Poloxamer 188 as surfactant in biological formulations - An alternative for polysorbate 20/80? Int J Pharm 2022; 620:121706. [PMID: 35367584 DOI: 10.1016/j.ijpharm.2022.121706] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 03/05/2022] [Accepted: 03/26/2022] [Indexed: 01/25/2023]
Abstract
Surfactants are used to stabilize biologics. Particularly, polysorbates (Tween® 20 and Tween® 80) dominate the group of surfactants in protein and especially antibody drug products. Since decades drug developers rely on the ethoxylated sorbitan fatty acid ester mixtures to stabilize sensitive molecules such as proteins. Reasons are (i) excellent stabilizing properties, and (ii) well recognized safety and tolerability profile of these polysorbates in humans, especially for parenteral applications. However, over the past decade concerns regarding the stability of these two polysorbates were raised. The search of alternatives with preferably less reservations concerning degradation and product quality reducing issues leads, among others, to poloxamer 188 (e.g. Kolliphor® P188), a nonionic triblock-copolymer surfactant. This review sums up our current knowledge related to the characterization and physico-chemical properties of poloxamer 188, its analytics and stability properties for biological formulations. Furthermore, the advantages and disadvantages as a suitable polysorbate-alternative for the stabilization of biologics are discussed.
Collapse
|
7
|
Johnstone P, Mast E, Hughes E, Peng H. Development of a small-scale rotary lobe-pump cell culture model for examining cell damage in large-scale N-1 seed perfusion process. Biotechnol Prog 2020; 36:e3044. [PMID: 32594624 DOI: 10.1002/btpr.3044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2019] [Revised: 06/25/2020] [Accepted: 06/26/2020] [Indexed: 11/12/2022]
Abstract
Perfusion technology has been identified as a process improvement capable of eliminating some of the constraints in cell culture and allows for high cell densities and viabilities. However, when implementing this N-1 seed perfusion platform in large-scale manufacturing, unexpected cell damage was observed as early as Day 1. Given that the shear rate within recirculation hollow fibers was normalized and aligned correctly across bench, pilot, and manufacture scale, the primary mitigation was placed on the rotary lobe pump. Lowering the pump rate in manufacture scale successfully alleviated the cell damage. To understand the source of cell damage within the pump, a small-scale rotary lobe-pump robustness model was developed. Testing different pump flow rates and back pressures, it was concluded that high back pressure can cause cell damage. The back pressure within the system can cause back flow and high shear within small clearances inside the pump, which lead to the primary cell damage observed at a large scale. This shear level can be significantly higher than the shear in the hollow fiber. This pump robustness model can be utilized to aid the perfusion skid design, including pump operation efficiency and cell shear sensitivity. Methods to reduce the back pressure and cell shearing were determined to better predict manufacturing performance in the future.
Collapse
Affiliation(s)
| | - Elena Mast
- Manufacturing Sciences, Biogen, Durham, North Carolina, USA
| | - Erik Hughes
- Manufacturing Sciences, Biogen, Durham, North Carolina, USA
| | - Haofan Peng
- Manufacturing Sciences, Biogen, Durham, North Carolina, USA
| |
Collapse
|
8
|
Narayanappa AT, Mwilu S, Holdread S, Hammett K, Bu G, Dodson EC, Brooks JW. A rapid cell-based assay for determining poloxamer quality in CHO suspension cell culture. Biotechniques 2019; 67:98-109. [PMID: 31347927 DOI: 10.2144/btn-2019-0070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Poloxamers are water-soluble polymers that are widely used in cell culture bioprocessing to protect cells against shearing forces. Use of poor-quality poloxamers may lead to a drastic reduction in cell growth, viabilities and productivities in cell culture-based manufacturing. In order to evaluate poloxamer quality and promote more consistent performance, a rapid cell membrane adhesion to hydrocarbon assay was developed based on the adhesive properties of cell membranes to selective hydrocarbons. The assay can identify a poor-performing poloxamer characterized by significant drop in viable cell density and percent viability. The assay was verified across multiple good and bad poloxamer lots, and the results were in agreement with established cell growth and high-performance liquid chromatography assays.
Collapse
Affiliation(s)
| | - Sam Mwilu
- Advanced Bioprocessing, Thermo Fisher Scientific, 250 Schilling Circle, Hunt Valley, MD 21030, USA
| | - Stacy Holdread
- Advanced Bioprocessing, Thermo Fisher Scientific, 250 Schilling Circle, Hunt Valley, MD 21030, USA
| | - Kimesha Hammett
- Advanced Bioprocessing, Thermo Fisher Scientific, 250 Schilling Circle, Hunt Valley, MD 21030, USA
| | - George Bu
- Advanced Bioprocessing, Thermo Fisher Scientific, 250 Schilling Circle, Hunt Valley, MD 21030, USA
| | - Elizabeth C Dodson
- Advanced Bioprocessing, Thermo Fisher Scientific, 250 Schilling Circle, Hunt Valley, MD 21030, USA
| | - James W Brooks
- Advanced Bioprocessing, Thermo Fisher Scientific, 250 Schilling Circle, Hunt Valley, MD 21030, USA
| |
Collapse
|
9
|
Bareford L, Peng H, Ali A, Kolwyck D, Dickens J. Development of a rapid and reliable analytical method for screening poloxamer 188 for use in cell culture process. Biotechnol Prog 2019; 35:e2792. [PMID: 30816019 DOI: 10.1002/btpr.2792] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 01/15/2019] [Accepted: 02/25/2019] [Indexed: 11/12/2022]
Abstract
Poloxamer P188 is a common nonionic surfactant additive used in cell culture media as a cellular protectant from the hydrodynamic forces and shear stress during bioprocessing. Presence of a hydrophobic high molecular weight impurity contaminant has been shown to compromise its protective properties and lead to batch failure. In this work we present, a reliable, sensitive, and rapid analytical method to detect and quantify the contaminant impurity in poloxamer 188. This method replaces a laborious and time-consuming functional test in the form of a shake flask assay. The method is based upon reversed-phase liquid chromatography with charged aerosol detection, simple mobile phase compositions, and a three-step gradient. The method was optimized to resolve the impurity from the main P188 fraction in less than 10 min. Analytical method qualification and functional test comparison demonstrate equivalent or better high throughput impurity screening performance. Attempts to identify the impurity and establish suitable method positive control standards are also discussed.
Collapse
Affiliation(s)
| | - Haofan Peng
- Manufacturing Sciences, Biogen, Davis, North Carolina
| | - Amr Ali
- Analytical Development, Biogen, Cambridge, Massachusetts
| | | | | |
Collapse
|
10
|
Dickens J, Khattak S, Matthews TE, Kolwyck D, Wiltberger K. Biopharmaceutical raw material variation and control. Curr Opin Chem Eng 2018. [DOI: 10.1016/j.coche.2018.10.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
11
|
Ritacco FV, Wu Y, Khetan A. Cell culture media for recombinant protein expression in Chinese hamster ovary (CHO) cells: History, key components, and optimization strategies. Biotechnol Prog 2018; 34:1407-1426. [DOI: 10.1002/btpr.2706] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 08/03/2018] [Accepted: 08/06/2018] [Indexed: 02/06/2023]
Affiliation(s)
- Frank V. Ritacco
- Biologics Process DevelopmentBristol‐Myers Squibb Pennington New Jersey United States
| | - Yongqi Wu
- Biologics Process DevelopmentBristol‐Myers Squibb Pennington New Jersey United States
| | - Anurag Khetan
- Biologics Process DevelopmentBristol‐Myers Squibb Pennington New Jersey United States
| |
Collapse
|
12
|
Chang D, Fox R, Hicks E, Ferguson R, Chang K, Osborne D, Hu W, Velev OD. Investigation of interfacial properties of pure and mixed poloxamers for surfactant-mediated shear protection of mammalian cells. Colloids Surf B Biointerfaces 2017; 156:358-365. [DOI: 10.1016/j.colsurfb.2017.05.040] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 05/10/2017] [Accepted: 05/13/2017] [Indexed: 11/27/2022]
|
13
|
Poellmann MJ, Lee RC. Repair and Regeneration of the Wounded Cell Membrane. REGENERATIVE ENGINEERING AND TRANSLATIONAL MEDICINE 2017. [DOI: 10.1007/s40883-017-0031-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
14
|
Impact of Pluronic ® F68 on hollow fiber filter-based perfusion culture performance. Bioprocess Biosyst Eng 2017; 40:1317-1326. [PMID: 28577048 DOI: 10.1007/s00449-017-1790-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2017] [Accepted: 05/24/2017] [Indexed: 10/19/2022]
Abstract
High cell density is an important factor in achieving high bioreactor productivity. To meet the oxygen demand with density at >100 × 106 cells/mL, a frit sparger is often used. In this study, the impact of Pluronic® F68 on a perfusion process using a frit sparger was studied. The perfusion process was developed using an alternating tangential flow device with a 0.2 µm PES hollow fiber filter. Pluronic® F68 at 2 g/L was sufficient in preventing cell damage at gas flow rate of ~0.20 vvm from a drilled hole sparger (0.5 mm) but inadequate at ~0.025 vvm from a frit sparger (20 µm). Increase of Pluronic® F68 concentration to 5 g/L prevented cell death at up to ~0.10 vvm from the frit sparger and was able to maintain high cell density at high viability in the range of 60-80 × 106 cells/mL. Such positive effect was demonstrated in both 3- and 200-L bioreactors. Supplementing additional Pluronic® F68 was also effective in restoring cell growth/viability from low viability cultures. Increased Pluronic® F68 concentration had no adverse impact on target antibody, HCP, and Pluronic® F68 transmissions.
Collapse
|
15
|
Peng H, Ali A, Lanan M, Hughes E, Wiltberger K, Guan B, Prajapati S, Hu W. Mechanism investigation for poloxamer 188 raw material variation in cell culture. Biotechnol Prog 2016; 32:767-75. [DOI: 10.1002/btpr.2268] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 03/22/2016] [Indexed: 02/03/2023]
Affiliation(s)
- Haofan Peng
- Cell Culture Development; Biogen; Research Triangle Park NC 27709
| | - Amr Ali
- Cell Culture Development; Biogen; Cambridge MA 02142
| | - Maureen Lanan
- Cell Culture Development; Biogen; Cambridge MA 02142
| | - Erik Hughes
- Manufacturing Sciences; Biogen; Research Triangle Park NC 27709
| | - Kelly Wiltberger
- Cell Culture Development; Biogen; Research Triangle Park NC 27709
| | - Bing Guan
- Cell Culture Development; Biogen; Cambridge MA 02142
| | | | - Weiwei Hu
- Cell Culture Development; Biogen; Research Triangle Park NC 27709
| |
Collapse
|
16
|
The role of high-throughput mini-bioreactors in process development and process optimization for mammalian cell culture. ACTA ACUST UNITED AC 2015. [DOI: 10.4155/pbp.15.22] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
17
|
Apostolidis PA, Tseng A, Koziol ME, Betenbaugh MJ, Chiang B. Investigation of low viability in sparged bioreactor CHO cell cultures points to variability in the Pluronic F-68 shear protecting component of cell culture media. Biochem Eng J 2015. [DOI: 10.1016/j.bej.2015.01.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|