Zanchetta M, Onorato E, Rigatelli G, Pedon L, Zennaro M, Carrozza A, Maiolino P. Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect.
J Am Coll Cardiol 2003;
42:1677-82. [PMID:
14607459 DOI:
10.1016/j.jacc.2003.08.023]
[Citation(s) in RCA: 72] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVES
We assessed the use of intracardiac echocardiography (ICE) as the primary means for both selection of the Amplatzer Septal Occluder (ASO) and the guidance of transcatheter closure of secundum atrial septal defects (ASDs).
BACKGROUND
The standard method for transcatheter closure of ASDs requires balloon-sizing maneuver and transesophageal echocardiographic (TEE) monitoring. The role of ICE during transcatheter closure of ASDs has not yet been established.
METHODS
In 91 patients with ASDs, two standardized orthogonal sections were used to obtain ICE-derived measurements of the fossa ovalis and to assess optimal device deployment: the transverse section on the aortic valve plane, and the longitudinal section on the four-chamber plane.
RESULTS
In all patients, ICE planes were identified with excellent resolution, providing proper measurements of the fossa ovalis, from which to derive geometric assumptions for the selection of an appropriately sized device. The ASO waist diameter was chosen on the basis of the r value (r = [square root c(2) + p(2)], where r is the radius of an ideal circle that intersects the elliptical fossa ovalis in its semi-latus rectum, c is the foci half-distance of the fossa ovalis, and p is its semi-latus rectum). During the procedure, the four-chamber plane allowed us to obtain easily interpretable images of all stages of device deployment. Midterm complete occlusion rate was 97.8%. No ICE-related complications occurred.
CONCLUSIONS
The ICE evaluation of ASDs allows quantitative and qualitative information for both proper ASO selection and optimal device placement, thus eliminating the cumbersome balloon-sizing maneuver and the need for general anesthesia during TEE monitoring.
Collapse