1
|
Pattathu J, Michel S, Tengler AI, Mandilaras G, Jakob A, Dalla Pozza R, Haas NA. Case report: Beneficial long-term effect of the atrial-flow-regulator device in a pediatric patient with idiopathic pulmonary arterial hypertension and recurring syncope. Front Cardiovasc Med 2023; 10:1197985. [PMID: 37745101 PMCID: PMC10516292 DOI: 10.3389/fcvm.2023.1197985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 07/27/2023] [Indexed: 09/26/2023] Open
Abstract
We report the long-term effect after successfully implanting an 8 mm Atrial-flow-regulator (AFR) device in a 7-year-old girl with idiopathic pulmonary hypertension with persistent syncope under triple therapy with significant improvement after implantation and absence of any further syncope. Early Implantation of the AFR device (Occlutech, Germany) can be efficient and safe interventional therapy option for pulmonary arterial hypertension with a history of syncope.
Collapse
|
2
|
Rigatelli G, Gianese F, Zuin M. Secundum atrial septal defects transcatheter closure: An updated reappraisal. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2022; 44:92-97. [PMID: 35680528 DOI: 10.1016/j.carrev.2022.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 06/03/2022] [Accepted: 06/03/2022] [Indexed: 11/30/2022]
Abstract
Transcatheter device-based closure is considered the first line therapy for congenital secundum atrial septal defect (ASD). The last 20 years literature data have been reviewed to offer an updated reappraisal of current evidences. Anatomical and functional details, appreciated at both pre-procedural and intraprocedural steps, remain of paramount importance for planning ASD transcatheter -based closure procedure. Routes for interventions should include femoral, and eventually the jugular and hepatic vein approaches. Intraprocedural transoesophageal echocardiography (TTE) or intracardiac echocardiography (ICE) is used at least in most complex cases to have the exact definition of the anatomy of the defects. The clinical outcomes are excellent also compared to surgical series with few complications even compare to surgical series. Transcatheter ASD closure represents the first line therapy in secundum ASD. Future developments of device's material and imaging tools are expected to improve safety and long-term efficacy, even in most complex cases.
Collapse
Affiliation(s)
| | - Filippo Gianese
- Division of Cardiology, Rovigo General Hospital, Rovigo, Italy
| | - Marco Zuin
- Section of Internal and Cardiopulmonary Medicine, Department of Medical Science, University of Ferrara, Ferrara, Italy
| |
Collapse
|
3
|
Mahmoud HT, Gaio G, Giordano M, Pizzuto A, Cuman M, Abdel Wahab MAK, Palladino MT, Russo MG, Santoro G. Transcatheter closure of fenestrated atrial septal aneurysm in children: Feasibility and long-term results. Catheter Cardiovasc Interv 2022; 99:2043-2053. [PMID: 35420259 DOI: 10.1002/ccd.30191] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 02/17/2022] [Accepted: 03/23/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND To date, extensive experience in transcatheter closure of fenestrated atrial septal aneurysm (ASA) in the pediatric population is limited. METHODS To report on procedural feasibility, efficacy, and long-term outcome, we enrolled all children submitted to an attempt of transcatheter closure of fenestrated ASA at two, large volume, pediatric cardiology units (Naples and Massa, Italy) between April 2000 to May 2020. RESULTS This retrospective study included 139 patients (median age 9 years [range 2-18] and weight 36 kg [range 10-102]); 19 (13.7%) children were ≤20 kg (range 10-20) and 14 (10.1%) were ≤5 years old. Single perforation was observed in 28 patients (20.1%), while 111 patients (79.9%) had multifenestrated ASA. The median size of the main defect was 15 mm (range 6-34) and 25 patients (18%) had a defect ≥20 mm. The procedural success rate was 99% (95% confidence interval [CI]: 94.9-99.8) using a single device in 75 (69%), two devices in 31 (28%), and three devices in 3 (3%) cases. Early minor adverse events (AEs) occurred in four patients (2.8%). Late minor AEs were recorded in one patient (0.7%) over a median follow-up of 5 years ([range 0-18 years; total 890.2 person-years, and with 30 patients (22%) followed ≥10 years). Neither mortality nor major AEs were recorded. Freedom from AEs was 99.1% at 10-15 years (95% CI: 93.5-99.8%), without any difference according to atrial septum anatomy or patient age and weight. CONCLUSION Transcatheter closure of fenestrated ASA is technically feasible and effective in children with excellent long-term outcomes.
Collapse
Affiliation(s)
- Heba Talat Mahmoud
- Pediatric Cardiology, University of Campania "Luigi Vanvitelli", "Ospedali dei Colli", Naples, Italy.,Cardiology Department, Minia University, Minia, Egypt
| | - Gianpiero Gaio
- Pediatric Cardiology, University of Campania "Luigi Vanvitelli", "Ospedali dei Colli", Naples, Italy
| | - Mario Giordano
- Pediatric Cardiology, University of Campania "Luigi Vanvitelli", "Ospedali dei Colli", Naples, Italy
| | - Alessandra Pizzuto
- Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", National Research Council-Tuscany Region Foundation "G. Monasterio", Massa, Italy
| | - Madgalena Cuman
- Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", National Research Council-Tuscany Region Foundation "G. Monasterio", Massa, Italy
| | | | - Maria Teresa Palladino
- Pediatric Cardiology, University of Campania "Luigi Vanvitelli", "Ospedali dei Colli", Naples, Italy
| | - Maria Giovanna Russo
- Pediatric Cardiology, University of Campania "Luigi Vanvitelli", "Ospedali dei Colli", Naples, Italy
| | - Giuseppe Santoro
- Pediatric Cardiology, University of Campania "Luigi Vanvitelli", "Ospedali dei Colli", Naples, Italy.,Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", National Research Council-Tuscany Region Foundation "G. Monasterio", Massa, Italy
| |
Collapse
|
4
|
Transcatheter closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim under echocardiography only: a feasibility and safety analysis. Cardiol Young 2022; 32:589-596. [PMID: 34247666 DOI: 10.1017/s104795112100264x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND The safe closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim is a controversial issue. Few studies have been conducted on the closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim without fluoroscopy. This study evaluated the feasibility and safety of echocardiography-guided transcatheter closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim. METHODS The data of 136 patients who underwent transcatheter atrial septal defect closure without fluoroscopy from March 2017 to March 2020 were retrospectively analysed. The patients were classified into the deficient (n = 45) and sufficient (n = 91) posterior-inferior or inferior vena cava rim groups. Procedure and the follow-up results were compared between the two groups. RESULTS Atrial septal defect indexed diameter and the device indexed diameter in the deficient rim group were both larger than that in the sufficient rim group (22.12 versus 17.38 mm/m2, p < 0.001; 24.77 versus 21.21 mm/m2, p = 0.003, respectively). There was no significant difference in the success rate of occlusion between two groups (97.78% in the deficient rim group versus 98.90% in the sufficient rim group, p = 1.000). During follow-up, the incidence of severe adverse cardiac events was not statistically significant (p = 0.551). CONCLUSIONS Atrial septal defect with deficient posterior-inferior or inferior vena cava rim can safely undergo transcatheter closure under echocardiography alone if precisely evaluated with transesophageal or transthoracic echocardiography and the size of the occluder is appropriate. The mid-term results after closure are similar to that for an atrial septal defect with sufficient rim.
Collapse
|
5
|
Fujimoto K, Kato A, Kitano M, Toyoshima Y, Sakaguchi H, Kurosaki K. Successful treatment of symptomatic first-degree atrioventricular block after Occlutech Figulla Flex II atrial septal defect occluder placement. J Cardiol Cases 2022; 25:126-129. [DOI: 10.1016/j.jccase.2021.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 07/20/2021] [Accepted: 07/28/2021] [Indexed: 11/25/2022] Open
|
6
|
Baykan A, Bilici M, Narin N, Erdem A, Uzum K, Akin A, Pamukcu O, Balik H, Ture M, Vural C, Dogan A. Percutaneous Closure of Atrial Septal Defects with the MemoPart Atrial Septal Occluder: The Early-Term Results of a Multicenter Study. Pediatr Cardiol 2022; 43:39-44. [PMID: 34401943 DOI: 10.1007/s00246-021-02688-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 07/23/2021] [Indexed: 11/28/2022]
Abstract
Atrial septal defect (ASD) is a common congenital heart disease with left-to-right shunt that may lead to pulmonary hypertension over time. Secundum ASD closure with transcatheter technique is currently the preferred method. The aim of this study was to evaluate the clinical experience and early-term outcomes of patients treated with a MemoPart ASD occluder device between June 2013 and June 2019. Fifty-six patients (35 females) with a mean age of 9.4 ± 6.6 years (range: 2-44 years) were included in the study. The diameters of the devices used to close the ASDs were 7-28 mm. The ratio of the device/defect diameter was 1.14:1. Atrial septal defect closure was applied successfully in all patients. The MemoPart septal occluder is a safe and effective device for ASD closure. In wide ASDs and cases with more than one deficient rim, weak rims, or wide and complicated cases, it can be used carefully with sufficient experience.
Collapse
Affiliation(s)
- Ali Baykan
- Department of Pediatric Cardiology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Meki Bilici
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Diyarbakır, Turkey. .,VM Medical Park Kocaeli Hastanesi, Ovacık Mah. D 100 Karayolu üzeri, Başiskele, Kocaeli, Turkey.
| | - Nazmi Narin
- Department of Pediatric Cardiology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Abdullah Erdem
- Department of Pediatric Cardiology, Medipol University Medical Faculty, İstanbul, Turkey
| | - Kazim Uzum
- Department of Pediatric Cardiology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Alper Akin
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Diyarbakır, Turkey
| | - Ozge Pamukcu
- Department of Pediatric Cardiology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Hasan Balik
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Diyarbakır, Turkey
| | - Mehmet Ture
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Diyarbakır, Turkey
| | - Cagdas Vural
- Department of Pediatric Cardiology, Erciyes University Medical Faculty, Kayseri, Turkey
| | - Alper Dogan
- Department of Pediatric Cardiology, Erciyes University Medical Faculty, Kayseri, Turkey
| |
Collapse
|
7
|
Cha SG, Kim MJ, Baek JS, Yu JJ, Kim YH. Procedural Predictors and Outcomes of Percutaneous Secundum Atrial Septal Defect Closure in Children Aged <6 Years. Circ J 2021; 85:1527-1534. [PMID: 33883381 DOI: 10.1253/circj.cj-20-1023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Percutaneous atrial septal defect (ASD) closure is the treatment of choice for patients with a suitable ASD anatomy; however, the procedural characteristics and outcomes in children aged <6 years are unclear. The feasibility and safety of percutaneous ASD closure in children aged <6 years was evaluated and the predictors of procedural failure and challenging cases were identified. METHODS AND RESULTS Patients from a single center between 2006 and 2018 (n=407) were retrospectively evaluated. There were 265 (65.1%) female patients. The median age at the time of the procedure and ASD size were 3.4 (0.9-5.9) years and 13.3 (3.8-27.0) mm, respectively. Medical records and echocardiographic images were analyzed. A challenging case was indicated by the use of non-conventional techniques. The procedure was completed in 399 patients (98.0%). Post-procedural acute complications occurred in 5 patients, including 1 with device embolization. Two patients underwent surgical device removal. During the follow up (30.3 [3.6-140.8] months), aggravated mitral regurgitation occurred in 5 patients. A multivariate logistic regression revealed large-sized ASD as a predictor of procedural failure (odds ratio=1.828, 95% confidence interval: 1.139-2.934, P=0.012) and challenging cases (odds ratio=1.371, 95% confidence interval: 1.180-1.593, P<0.001). CONCLUSIONS Percutaneous ASD closure is feasible and safe in children aged <6 years; however, patients with large-sized ASD are at high risk of procedural failure and becoming a challenging case.
Collapse
Affiliation(s)
- Seul Gi Cha
- Division of Pediatric Cardiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Mi Jin Kim
- Division of Pediatric Cardiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Jae Suk Baek
- Division of Pediatric Cardiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Jeong Jin Yu
- Division of Pediatric Cardiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Young-Hwue Kim
- Division of Pediatric Cardiology, Asan Medical Center, University of Ulsan College of Medicine
| |
Collapse
|
8
|
Prediction of arrhythmia after intervention in children with atrial septal defect based on random forest. BMC Pediatr 2021; 21:280. [PMID: 34134641 PMCID: PMC8207618 DOI: 10.1186/s12887-021-02744-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 05/27/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Using random forest to predict arrhythmia after intervention in children with atrial septal defect. METHODS We constructed a prediction model of complications after interventional closure for children with atrial septal defect. The model was based on random forest, and it solved the need for postoperative arrhythmia risk prediction and assisted clinicians and patients' families to make preoperative decisions. RESULTS Available risk prediction models provided patients with specific risk factor assessments, we used Synthetic Minority Oversampling Technique algorithm and random forest machine learning to propose a prediction model, and got a prediction accuracy of 94.65 % and an Area Under Curve value of 0.8956. CONCLUSIONS Our study was based on the model constructed by random forest, which can effectively predict the complications of arrhythmia after interventional closure in children with atrial septal defect.
Collapse
|
9
|
Diab KA, Boujemline Y, Hijazi ZM. Update on shunt closure in neonates and infants. Expert Rev Cardiovasc Ther 2021; 19:475-492. [PMID: 33899641 DOI: 10.1080/14779072.2021.1922079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Introduction: Cardiac defects that result in shunting are the most common types of congenital heart anomalies. Although these lesions can be simple, they can cause significant hemodynamic changes and can be challenging to manage in neonates and infants. Over the recent decades, the development of new transcatheter techniques and devices has made it safe and feasible to manage such defects when indicated, even in the smallest of patients. Understanding these interventional procedures is essential in order to manage those patients.Areas covered: In this article, we review the techniques and experience for closure of atrial septal defects, ventricular septal defects, patent ductus aarteriosus,as well as coronary arteriovenous malformations and fistulas in neonates and infants. Literature review of PubMed articles was performed through January 2021, with focus on the latest data and results of the usage of interventional techniques in treating these lesions specifically in this age-group.Expert opinion: Significant shunting lesions can be particularly challenging to manage in neonates and infants. Newer lower profile devices will likely continue to be developed in the future, allowing their use for transcatheter interventions in even smaller patients and those with more complex anatomy.
Collapse
Affiliation(s)
- Karim A Diab
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar
| | - Younes Boujemline
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar
| | - Ziyad M Hijazi
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar.,Weill Cornell Medical College, Doha, Qatar.,Weill Cornell Medical College, New York, NY, USA
| |
Collapse
|
10
|
Vanhie E, VandeKerckhove K, Haas NA, De Wolf D. Atrial flow regulator for drug-resistant pulmonary hypertension in a young child. Catheter Cardiovasc Interv 2021; 97:E830-E834. [PMID: 33650782 DOI: 10.1002/ccd.29590] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 02/14/2021] [Accepted: 02/15/2021] [Indexed: 11/10/2022]
Abstract
This case describes the successful implantation of an Occlutech Atrial Flow Regulator in a young child with idiopathic pulmonary hypertension and recurrent syncope despite targeted combination therapy, with subsequent relief of symptoms.
Collapse
Affiliation(s)
- Ellen Vanhie
- Department of Pediatrics, Pediatric Cardiology, Amsterdam University Hospital, Amsterdam, The Netherlands
| | - Kristof VandeKerckhove
- Department of Pediatrics, Pediatric Cardiology, Ghent University Hospital, Ghent, Belgium
| | - Nikolaus A Haas
- Department of Pediatrics, Pediatric Cardiology, LMU Klinikum, München, Germany
| | - Daniel De Wolf
- Department of Pediatrics, Pediatric Cardiology, Ghent University Hospital, Ghent, Belgium.,Department of Pediatrics, Pediatric Cardiology, Brussel University Hospital, Brussels, Belgium
| |
Collapse
|
11
|
Zhang ZQ, Ding JW. Perforation of the atrial wall and aortic sinus after closure of an atrial septal defect with an Atriasept occluder: a case report. J Cardiothorac Surg 2021; 16:53. [PMID: 33766059 PMCID: PMC7993524 DOI: 10.1186/s13019-021-01441-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 03/17/2021] [Indexed: 11/21/2022] Open
Abstract
Background While the perforation of the atrial wall and aortic sinus after closure of an atrial septal defect (ASD) is rare, it’s life-threatening, with rapid progress and high mortality. To the best of our knowledge, 21 similar cases have been reported since 1976. Case presentation We report a 16-year-old male whose atrial septal defect (ASD) was closed using a 12-mm Amplatzer septal occluder (ASO). Atrial wall and aortic sinus perforation occurred 3 months after transcatheter closure, and the patient was discharged after emergency operation. He was discharged on the 12th postoperative day in good overall condition. Conclusions With this case report, we want to illustrate that although percutaneous closure of ASD is regarded as a routine procedure, we should not forget the potentially lethal complications, especially cardiac erosion. Therefore, we should carefully evaluate the risk of erosion before surgery, and careful lifelong follow-up is needed.
Collapse
Affiliation(s)
- Zai-Qiang Zhang
- Department of Cardiology, The First College of Clinical Medical Sciences, China Three Gorges University, 183 Yiling Road, Yichang, Hubei Province, 443000, People's Republic of China.,Institute of Cardiovascular Diseases, China Three Gorges University, Yichang, Hubei Province, 443000, People's Republic of China
| | - Jia-Wang Ding
- Department of Cardiology, The First College of Clinical Medical Sciences, China Three Gorges University, 183 Yiling Road, Yichang, Hubei Province, 443000, People's Republic of China. .,Institute of Cardiovascular Diseases, China Three Gorges University, Yichang, Hubei Province, 443000, People's Republic of China.
| |
Collapse
|
12
|
Tamura Y, Yonehara Y, Horibata Y, Uesugi H, Sawamura T, Sakamoto T. The first described case of late infective endocarditis after implantation of Figulla Flex Ⅱ ASD occluder. J Cardiol Cases 2021; 23:214-217. [PMID: 33995699 DOI: 10.1016/j.jccase.2020.11.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/22/2020] [Accepted: 10/17/2020] [Indexed: 11/19/2022] Open
Abstract
Infective endocarditis is one of the complications following the percutaneous occlusion of an atrial septal defect (ASD) with a closure device. To the best of our knowledge, no case reports have been published of infective endocarditis associated with the Figulla Flex Ⅱ ASD occluder (FSO; Occlutech GmbH, Jena, Germany). We present the case of a 50-year-old woman who underwent a transcatheter closure of an ASD with FSO almost 2 years prior to presentation to our institution. Echocardiography showed a mobile vegetation (20 × 10 mm), and her blood culture grew β-hemolytic streptococci. Magnetic resonance imaging revealed acute cerebral infarction. Those findings were diagnosed as late infective endocarditis associated with the ASD closure device. The patient was treated with antibiotics and underwent surgical removal of the FSO, which showed incomplete endothelialization, and surgical repair of ASD. After surgery, the patient made a complete recovery without complications or residual shunts. This case highlights the risk of late infective endocarditis in patients after closure of ASD with an FSO with incomplete endothelialization. <Learning objective: Endothelialization of Figulla Flex Ⅱ ASD occluder (FSO) devices is presumed to be complete within 3 to 6 months. However, some patients have presented with poor endothelialization of the device. In patients who undergo percutaneous atrial septal defect closure with an FSO, delayed endothelialization of the device could be a risk for late infective endocarditis. We suggest the need to be aware of the onset of late infective endocarditis even after 6 months after placement of an FSO.>.
Collapse
Affiliation(s)
- Yudai Tamura
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| | - Yuki Yonehara
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| | - Yoko Horibata
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| | - Hideyuki Uesugi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| | - Tadashi Sawamura
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| | - Tomohiro Sakamoto
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| |
Collapse
|
13
|
Nakayama R, Takaya Y, Akagi T, Watanabe N, Miki T, Nakagawa K, Toh N, Ito H. Efficacy and safety of atrial septal defect closure using Occlutech Figulla Flex II compared with Amplatzer Septal Occluder. Heart Vessels 2021; 36:704-709. [PMID: 33386412 DOI: 10.1007/s00380-020-01739-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 11/20/2020] [Indexed: 11/25/2022]
Abstract
Few studies have reported the efficacy of Occlutech Figulla Flex II (FFII) device compared with Amplatzer Septal Occluder (ASO) device. The aim of this study was to examine the efficacy and safety of FFII compared with ASO for transcatheter atrial septal defect (ASD) closure. We retrospectively evaluated 190 patients using FFII and 190 patients using ASO who underwent transcatheter ASD closure. ASD characteristics were evaluated by transesophageal echocardiography. The prevalence of procedural complications, including erosion, device embolization, stroke, and new-onset atrial arrhythmia, and the presence of a residual shunt were evaluated between the two groups during 12-month follow-up. FFII was used more frequently than ASO in patients with a deficient aortic rim or septal malalignment (P = 0.02, P < 0.01, respectively). The procedural complications of erosion, device embolization, and stroke did not occur in any patients. New-onset atrial arrhythmia occurred in 3 patients of the FFII group and 4 patients of the ASO group, and the difference between the two groups was not significant (P = 0.70). A large residual shunt (≥ 3 mm) was observed in 6 patients of the FFII group and 5 patients of the ASO group, and the difference between the two groups was not significant (P = 0.76). FFII was used frequently in patients with high-risk ASD morphology; however, there was no difference in the prevalence of procedural complications or efficacy between patients using FFII and those using ASO.
Collapse
Affiliation(s)
- Rie Nakayama
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| | - Yoichi Takaya
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
| | - Teiji Akagi
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| | - Nobuhisa Watanabe
- Division of Medical Support, Okayama University Hospital, Okayama, Japan
| | - Takashi Miki
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| | - Koji Nakagawa
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| | - Norihisa Toh
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| | - Hiroshi Ito
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| |
Collapse
|
14
|
Haddad RN, Khraiche D, Bonnet D, Meot M, Malekzadeh-Milani S. Preliminary Experience With the New Amplatzer™ Trevisio™ Delivery System in Transcatheter Atrial Septal Defect Closures in Children. Front Pediatr 2021; 9:641742. [PMID: 33791259 PMCID: PMC8006412 DOI: 10.3389/fped.2021.641742] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/08/2021] [Indexed: 11/13/2022] Open
Abstract
Objectives: To evaluate safety, efficacy, and technical advantages of Amplatzer™ Trevisio™ intravascular delivery system (ATIDS) in percutaneous atrial septal defect (ASD) closure in children. Background: The Trevisio™ is a novel delivery system designed for accurate and facilitated implantation of Amplatzer™ devices. There are no published clinical reports so far. Methods: During September 2020, 9 children with anatomically challenging ASDs underwent attempted transcatheter closure using ATIDS to deliver Amplatzer™ Septal occluders (ASO). All interventions were performed under general anesthesia, trans-esophageal echocardiography (TOE), and fluoroscopic guidance. Standard safety, immediate, and 60-days outcomes were prospectively assessed. Results: The median age was 8.1 (5.1-16.9) years and the median bodyweight was 30 (18-63) kg. Six patients had isolated secundum-type ASDs with absent anterosuperior rims including one with an aneurysmal septum. Three patients had unclassical defects associated with complex congenital heart anomalies. Eight devices were delivered from the femoral vein and the jugular vein was accessed in one patient with interrupted inferior caval vein and azygos continuation. All implantations were successful. The shape, position, and orientation of the ASO were identical before and after release on TOE and fluoroscopy. There was no device embolization or serious complication following closure. Complete shunt closure was confirmed on follow-up. Conclusions: We report the first clinical experience with ATIDS in transcatheter ASD pediatric closures. Safety and efficacy were witnessed in our case-series. The major advantage of reduced-tension deployment and reliable precision in device positioning is highly beneficial in challenging anatomies and unusual access.
Collapse
Affiliation(s)
- Raymond N Haddad
- M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| | - Diala Khraiche
- M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| | - Damien Bonnet
- M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.,Université de Paris, Paris, France
| | - Mathilde Meot
- M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| | - Sophie Malekzadeh-Milani
- M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| |
Collapse
|
15
|
Microtransesophageal Echocardiographic Guidance during Percutaneous Interatrial Septal Closure without General Anaesthesia. J Interv Cardiol 2020; 2020:1462140. [PMID: 32982607 PMCID: PMC7492935 DOI: 10.1155/2020/1462140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 07/30/2020] [Accepted: 08/31/2020] [Indexed: 11/23/2022] Open
Abstract
Objective To study the safety and efficacy of microtransesophageal echocardiography (micro-TEE) and TEE during percutaneous atrial septal defect (ASD) and patent foramen ovale (PFO) closure. Background TEE has proven to be safe during ASD and PFO closure under general anaesthesia. Micro-TEE makes it possible to perform these procedures under local anaesthesia. We are the first to describe the safety and efficacy of micro-TEE for percutaneous closure. Methods All consecutive patients who underwent ASD and PFO closure between 2013 and 2018 were included. The periprocedural complications were registered. Residual shunts were diagnosed using transthoracic contrast echocardiography (TTCE). All data were compared between the use of TEE or micro-TEE within the ASD and PFO groups separately. Results In total, 82 patients underwent ASD closure, 46 patients (49.1 ± 15.0 years) with TEE and 36 patients (47.8 ± 12.1 years) using micro-TEE guidance. Median device diameter was, respectively, 26 mm (range 10–40 mm) and 27 mm (range 10–35 mm). PFO closure was performed in 120 patients, 55 patients (48.6 ± 9.2 years, median device diameter 25 mm, range 23–35 mm) with TEE and 65 patients (mean age 51.0 ± 11.8 years, median device diameter 27 mm, range 23–35 mm) using micro-TEE. There were no major periprocedural complications, especially no device embolizations within all groups. Six months after closure, there was no significant difference in left-to-right shunt after ASD closure and no significant difference in right-to-left shunt after PFO closure using TEE or micro-TEE. Conclusion Micro-TEE guidance without general anaesthesia during percutaneous ASD and PFO closure is as safe as TEE, without a significant difference in the residual shunt rate after closure.
Collapse
|
16
|
Barioli A, Cardaioli F, Pavei A, Tarantini G. Transcatheter closure of complex iatrogenic ventricular septal defect: a case report. EUROPEAN HEART JOURNAL-CASE REPORTS 2020; 4:1-5. [PMID: 32617468 PMCID: PMC7319813 DOI: 10.1093/ehjcr/ytaa106] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 10/15/2019] [Accepted: 04/14/2020] [Indexed: 12/03/2022]
Abstract
Background Iatrogenic membranous ventricular septal defects (VSDs) are rare complications of cardiothoracic surgery, such as septal myectomy for hypertrophic obstructive cardiomyopathy (HOCM). Transcatheter closure is considered an appealing alternative to surgery, given the increased mortality associated with repeated surgical procedures, but reports are extremely limited. Case summary We herein report the case of a 63-year-old woman with HOCM who underwent successful percutaneous closure of an iatrogenic VSD after septal myectomy. Two percutaneous techniques are discussed, namely the ‘muscular anchoring’ and the ‘buddy wire delivery’, aimed at increasing support and providing stability to the system during percutaneous intervention. Discussion Transcatheter closure represents an attractive minimally invasive approach for the management of symptomatic iatrogenic VSDs. The new techniques described could help operators to cross tortuous and tunnelled defects and to deploy closure devices in case of complex VSD anatomy.
Collapse
Affiliation(s)
- Alberto Barioli
- Department of Cardiac, Thoracic and Vascular Sciences, Cardiology Unit, University of Padua Medical School, Via Giustiniani, 2, 35128 Padua, Italy
| | - Francesco Cardaioli
- Department of Cardiac, Thoracic and Vascular Sciences, Cardiology Unit, University of Padua Medical School, Via Giustiniani, 2, 35128 Padua, Italy
| | - Andrea Pavei
- Department of Cardiac, Thoracic and Vascular Sciences, Cardiology Unit, University of Padua Medical School, Via Giustiniani, 2, 35128 Padua, Italy
| | - Giuseppe Tarantini
- Department of Cardiac, Thoracic and Vascular Sciences, Cardiology Unit, University of Padua Medical School, Via Giustiniani, 2, 35128 Padua, Italy
| |
Collapse
|
17
|
Alkashkari W, Albugami S, Hijazi ZM. Current practice in atrial septal defect occlusion in children and adults. Expert Rev Cardiovasc Ther 2020; 18:315-329. [PMID: 32441165 DOI: 10.1080/14779072.2020.1767595] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
INTRODUCTION Atrial septal defect (ASD) is one of the most common congenital heart diseases (CHD) in children and adults. This group of malformations includes several types of atrial communications allowing shunting of blood between the systemic and the pulmonary circulations. Early diagnosis and treatment carries favorable outcomes. Patients diagnosed during adulthood often present with complications related to longstanding volume overload such as pulmonary artery hypertension (PAH), atrial dysrhythmias, and right (RV) and left (LV) ventricular dysfunction. AREA COVERED This article intended to review all aspects of ASD; anatomy, pathophysiology, clinical presentation, natural history, and indication for treatment. Also, we covered the transcatheter therapy in detail, including the procedural aspect, available devices, and outcomes. EXPERT OPINION There has been a remarkable improvement in the treatment strategy of ASD over the last few decades. Transcatheter closure of ASD is currently accepted as the treatment of choice in most patients with appropriately selected secundum ASDs. This review will focus on the most recent advances in diagnosis and treatment strategy of secundum ASD.
Collapse
Affiliation(s)
- Wail Alkashkari
- Department of Cardiology, King Faisal Cardiac Center, Ministry of National Guard Health Affairs , Jeddah, Saudi Arabia.,Department of Postgraduate, King Saud Bin Abdulaziz University for Health Science , Jeddah, Saudi Arabia.,Department of Medical Research, King Abdullah International Medical Research Center , Jeddah, Saudi Arabia
| | - Saad Albugami
- Department of Postgraduate, King Saud Bin Abdulaziz University for Health Science , Jeddah, Saudi Arabia
| | - Ziyad M Hijazi
- Sidra Heart Center, Sidra Medicine , Doha, Qatar.,Weill Cornell Medicine , New York, NY, USA
| |
Collapse
|
18
|
Cardiac erosion causing an aortic dissection after a catheter closure of an atrial septal defect: first late erosion case with the Figulla Flex II septal occluder. Cardiovasc Interv Ther 2020; 36:270-272. [PMID: 32248357 DOI: 10.1007/s12928-020-00664-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 03/28/2020] [Indexed: 10/24/2022]
|
19
|
Malposition of left atrial disc and feasibility of recapturing Figulla-II Occlutech septal occluder. Cardiol Young 2020; 30:444-445. [PMID: 32066513 DOI: 10.1017/s104795112000027x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We report a case of Figulla-II Occlutech septal occluder malposition with residual shunt at posteriosuperior margin of an atrial septal defect. Improvising its bioptome type delivery cable, same system was used to recapture the device and redeploy it successfully. This report highlights a potential malfunction of Figulla-II Occlutech disc and the advantage of its delivery system for retrieval of the device.
Collapse
|
20
|
Percutaneous Atrial Septal Defect Closure Using the Occlutech Figulla Device in Adults: More than 800 Patient-Years of Follow-Up. J Interv Cardiol 2020; 2020:7136802. [PMID: 32140088 PMCID: PMC7042503 DOI: 10.1155/2020/7136802] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 01/18/2020] [Accepted: 01/25/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose The Occlutech Figulla occluder has been proven safe and effective at midterm follow-up after percutaneous atrial septal defect (ASD) closure. We describe the safety and efficacy at long-term follow-up in adults. Methods All consecutive adult patients that underwent ASD closure between 2008 and 2015 were included. All complications were registered. Residual left-to-right shunt (LRS) was diagnosed using color-Doppler transthoracic echocardiography (TTE). Right-to-left shunting was diagnosed using contrast TTE. Successful closure was defined as no LRS at follow-up. Results In total, 166 patients (mean age 56.7 ± 16.1 years; 62% female) underwent percutaneous ASD closure using the Occlutech Flex I (70%) or Flex II (30%) device (diameter 24 mm; range 10-40 mm) under general anaesthesia and transoesophageal echocardiographic guidance. Long-term follow-up data were available for 144 patients (87%) with a mean follow-up of 5.9 ± 2.6 years, a total of 814 patient-years. During hospitalization, device embolization occurred in three patients (1.8%) with successful extraction in all. During the long-term follow-up, 15 patients (9.8%) suffered new-onset atrial fibrillation and stroke occurred in 2.1%. There was no residual LRS at 12-month follow-up. No device embolization occurred during the long-term follow-up. Conclusion Percutaneous ASD closure using the Occlutech device appears to be safe at long-term follow-up with a high successful closure rate at one year.
Collapse
|
21
|
Shi D, Kang Y, Zhang G, Gao C, Lu W, Zou H, Jiang H. Biodegradable atrial septal defect occluders: A current review. Acta Biomater 2019; 96:68-80. [PMID: 31158496 DOI: 10.1016/j.actbio.2019.05.073] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 05/21/2019] [Accepted: 05/29/2019] [Indexed: 01/11/2023]
Abstract
Atrial septal defect (ASD) is a common structural congenital heart disease. With the development of interventional closure devices and transcatheter techniques, interventional closure therapy has become the most well-accepted therapeutic alternative worldwide, as it offers a number of advantages over conventional therapies such as improved safety, easier operation, lower complication rates and invasiveness, and shorter anesthetic time and hospitalizations. During the past decades, various types of occluders based on nondegradable shape memory alloys have been used in clinical applications. Considering that the permanent existence of foreign nondegradable materials in vivo can cause many potential complications in the long term, the research and development of biodegradable occluders has emerged as a crucial issue for interventional treatment of ASD. This review aims to summarize partially or fully biodegradable occlusion devices currently reported in the literature from the aspects of design, construction, and evaluation of animal experiments. Furthermore, a comparison is made on the advantages and disadvantages of the materials used in biodegradable ASD occlusion devices, followed by an analysis of the problems and limitations of the occlusion devices. Finally, several strategies are proposed for future development of biodegradable cardiac septal defect occlusion devices. STATEMENT OF SIGNIFICANCE: Although occlusion devices based on nondegradable alloys have been widely used in clinical applications and saved numerouspatients, biodegradable occlusion devices may offer some advantages such as fewer complications, acceptable biocompatibility, and particularly temporary existence, thereby leaving "native" tissue behind, which will certainly become the development trend in the long term. This review summarizes almost all partially or fully biodegradable occlusion devices currently reported in the literature from the aspects of design, construction, and evaluation of animal experiments. Furthermore, a comparison is made on the advantages and disadvantages of the materials used in biodegradable ASD occlusion devices, followed by an analysis of the problems and limitations of the occlusion devices. Finally, several strategies are proposed for future development of biodegradable cardiac septal defect occlusion devices.
Collapse
|
22
|
Abe T, Tsukano S, Tosaka Y. Pericardial tamponade due to erosion of a Figulla Flex II device after closure of an atrial septal defect. Catheter Cardiovasc Interv 2019; 94:1003-1005. [DOI: 10.1002/ccd.28367] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 05/03/2019] [Accepted: 05/28/2019] [Indexed: 11/07/2022]
Affiliation(s)
- Tadaaki Abe
- Department of PediatricsNiigata University School of Medicine Niigata Japan
| | - Shinya Tsukano
- Department of PediatricsNiigata City General Hospital Niigata Japan
| | - Yuko Tosaka
- Department of Cardiovascular SurgeryNiigata City General Hospital Niigata Japan
| |
Collapse
|
23
|
Sato J, Kato A, Takeda S, Nishikawa H. Case report: Atrioventricular block after transcatheter atrial septal closure using the Figulla® Flex II ASD occluder. Catheter Cardiovasc Interv 2019; 93:E298-E301. [PMID: 30773790 DOI: 10.1002/ccd.28148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2018] [Revised: 01/07/2019] [Accepted: 01/28/2019] [Indexed: 11/12/2022]
Abstract
We report a 7-year-old male patient who developed severe atrioventricular block after transcatheter closure of the atrial septal defect with an Occlutech Figulla® Flex II ASD occluder (FSO). He had a small aortic rim and the defect measuring 22.3 mm by balloon sizing. When a 24 mm FSO was deployed, he developed Wenckebach second-degree heart block; however, it recovered to sinus rhythm. Hence, the device was implanted. The rhythm deteriorated to a fixed 2:1 heart block within 7 hr. He underwent surgical retrieval of the device and closure of the defect. Intraoperative findings demonstrated the right atrium disk compressing the triangle of Koch, resulting in a small hematoma. The rhythm recovered completely by 7 days after the surgery. Care must be taken when a relatively large device is deployed in a patient with small rims as even "soft and flexible" device like the FSO can injure the endocardium.
Collapse
Affiliation(s)
- Jun Sato
- Department of Paediatric Cardiology, Japan Community Health Organization Chukyo Hospital, Nagoya, Japan
| | - Atsuko Kato
- Department of Paediatric Cardiology, Japan Community Health Organization Chukyo Hospital, Nagoya, Japan
| | - Sho Takeda
- Department of Paediatric Cardiology, Japan Community Health Organization Chukyo Hospital, Nagoya, Japan
| | - Hiroshi Nishikawa
- Department of Paediatric Cardiology, Japan Community Health Organization Chukyo Hospital, Nagoya, Japan
| |
Collapse
|
24
|
Amedro P, Bayburt S, Assaidi A, Kreitmann B, Habib G, Fouilloux V, Fraisse A. Should transcatheter closure of atrial septal defects with inferior-posterior deficient rim still be attempted? J Thorac Dis 2019; 11:708-716. [PMID: 31019758 DOI: 10.21037/jtd.2019.02.89] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Transcatheter closure for atrial septal defect (ASD) with inferior-posterior rim deficiency has been scarcely reported with proper identification of the indications and limits. We aimed to assess the safety and feasibility of transcatheter closure of ASDs with deficient rims, paying particular attention to cases with inferior-posterior rim deficiency. Methods From January 2008 to January 2013, 241 patients underwent transcatheter ASD closure, including 50 cases (20.7%) with deficient rims, other than the anterior-superior one. Eighteen patients (12 females) presented inferior-posterior rim deficiency. Their median age was 8 (1.4-85) years and their median weight was 24 [9-97] kg. Transcatheter closure was performed in all cases under transesophageal echocardiography (TEE) guidance in children and intracardiac echocardiography (ICE) guidance in adults. Results Out of 18 patients with inferior-posterior rim deficiency, only 8 underwent successful immediate transcatheter closure. Four cases failed to be closed. Major complications occurred in 6 patients, including 4 device embolizations, 1 pericardial effusion and 1 complete atrioventricular block that resolved after surgical removal of the device. During a median follow up of 54±13 months, a residual right-to-left shunt was documented in 2 more cases, requiring surgery in one case because of cyanosis. Transcatheter closure was successfully performed in the rest of the 223 patients, including in the 32 cases with deficient rims other than inferior-posterior. Conclusions Transcatheter closure of ASDs with inferior-posterior rim deficiency cannot be recommended.
Collapse
Affiliation(s)
- Pascal Amedro
- PhyMedExp, University of Montpellier, INSERM, CNRS, Montpellier, France.,Pediatric and Congenital Cardiology Department, M3C Regional Reference Centre, Montpellier University Hospital, Montpellier, France
| | - Selin Bayburt
- School of Medicine, Acibadem University, Istanbul, Turkey
| | - Anass Assaidi
- Pediatric and Congenital Cardiology Department, M3C Reference Regional Centre, La Timone University Hospital, Marseille, France
| | - Bernard Kreitmann
- Department of Cardiovascular Surgery, Bordeaux University Hospital, Bordeaux, France
| | | | | | - Alain Fraisse
- Pediatric Cardiology Service, Royal Brompton and Harefield Hospital Trust, London, UK
| |
Collapse
|
25
|
Kaley V, Dahdah N, El-Sisi A, Grohmann J, Rosenthal E, Jones M, Morgan G, Hayes N, Shah A, Karakurt C, Sadiq M, Sigler M, Figulla H, Becker M, Haas N, Onorato E, Rico AP, Roymanee S, Uebing A, Wiebe W, Samuel B, Hijazi Z, Vettukattil J. Atrial Septal Defect–Associated Pulmonary Hypertension: Outcomes of Closure With a Fenestrated Device. ACTA ACUST UNITED AC 2019. [DOI: 10.21693/1933-088x-18.1.4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Vishal Kaley
- Spectrum Health Helen DeVos Children's Hospital, USA
| | | | | | - Jochen Grohmann
- University Heart Center Freiburg - Bad Krozingen, Mathildenstrasse, Germany
| | | | | | | | | | - Ashish Shah
- Central Manchester University Hospitals, NHS Foundation Trust, United Kingdom
| | | | - Masood Sadiq
- The Children's Hospital Lahore and Punjab Institute of Cardiology, Pakistan
| | | | - Hans Figulla
- Universitätsklinikum Jena, Friedrich Schiller Universität Jena, Germany
| | | | - Nikolaus Haas
- Medical Hospital of the University of Munich, Germany
| | | | | | | | | | - Walter Wiebe
- Deutsches Kinderherzzentrum Sankt Augustin, Germany
| | | | - Ziyad Hijazi
- Weill Cornell Medicine, USA
- Sidra Medicine, Doha, Qatar
| | - Joseph Vettukattil
- Spectrum Health Helen DeVos Children's Hospital, USA
- Michigan State University, USA
| |
Collapse
|
26
|
Parekh DR, Krajcer Z. Percutaneous atrial septal occluders: Are we there yet? Catheter Cardiovasc Interv 2019; 93:322-323. [DOI: 10.1002/ccd.28080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Accepted: 12/29/2018] [Indexed: 11/09/2022]
Affiliation(s)
- Dhaval R. Parekh
- Department of CardiologyTexas Heart Institute Houston Texas
- Division of Cardiology, Department of Internal MedicineBaylor College of Medicine Houston Texas
- Department of Internal MedicineCHI St. Luke's Health—Baylor St. Luke's Medical Center Houston Texas
| | - Zvonimir Krajcer
- Department of CardiologyTexas Heart Institute Houston Texas
- Division of Cardiology, Department of Internal MedicineBaylor College of Medicine Houston Texas
- Department of Internal MedicineCHI St. Luke's Health—Baylor St. Luke's Medical Center Houston Texas
| |
Collapse
|
27
|
Kubicki R, Fingerhut K, Uhl M, Hummel J, Höhn R, Reineker K, Fleck T, Stiller B, Grohmann J. Wire‐frame integrity of patch‐like Gore devices following atrial septal defect closure. Catheter Cardiovasc Interv 2019; 93:E238-E243. [DOI: 10.1002/ccd.28103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Revised: 12/31/2018] [Accepted: 01/02/2019] [Indexed: 11/10/2022]
Affiliation(s)
- R. Kubicki
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - K. Fingerhut
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - M. Uhl
- Department of Diagnostic and Therapeutic RadiologySt. Josef's Hospital Freiburg Germany
| | - J. Hummel
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - R. Höhn
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - K. Reineker
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - T. Fleck
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - B. Stiller
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| | - J. Grohmann
- Department of Congenital Heart Disease and Pediatric Cardiology, University Heart Center Freiburg – Bad Krozingen, Medical Center‐University of Freiburg, Faculty of MedicineUniversity of Freiburg Freiburg Germany
| |
Collapse
|
28
|
Kim AY, Jung SY, Chang JY, Jung JW, Choi JY. Early to Mid-Term Follow-Up Outcomes of Percutaneous Closure of Atrial Septal Defects Using Recent Generation Devices: a Single-Center Experience. Korean Circ J 2018; 49:326-335. [PMID: 30808079 PMCID: PMC6428945 DOI: 10.4070/kcj.2018.0278] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Accepted: 11/27/2018] [Indexed: 11/11/2022] Open
Abstract
Background and Objectives This study aimed to describe our early to mid-term experience with transcatheter atrial septal defect (ASD) closure using the Occlutech Figulla® Flex II device (FSO), Gore® Cardioform septal occluder (GSO), and Amplatzer® septal occluder (ASO) after they were first approved in Korea in 2014, and to compare the three aforementioned kinds of ASD closure devices. Methods Between September 2014 and August 2016, 267 patients underwent transcatheter ASD closure in our institution. Baseline characteristics, hemodynamic features, comorbidities, and procedural success and complication rates were analyzed retrospectively. The unpaired Student t-test or variance analysis was used in the statistical analysis. Results The FSO was most commonly used (n=152, 56.9%), followed by the ASO (n=98, 36.7%) and GSO (n=17, 6.4%). Baseline characteristics and hemodynamic features were similar between the devices, except that the defect size and pulmonary flow-to-systemic flow ratio were lower in the GSO group than in the other groups. Overall, the procedural success rate remained at 100%, and major complication rate was <1%. No late complication occurred during the follow-up. Conclusions The FSO and GSO are feasible, safe options for use in transcatheter ASD closure, and they are comparable to the ASO.
Collapse
Affiliation(s)
- Ah Young Kim
- Division of Pediatric Cardiology, Center for Congenital Heart Disease, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Se Yong Jung
- Division of Pediatric Cardiology, Center for Congenital Heart Disease, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jenny Yeonsoo Chang
- Department of Biological Basis of Behavior, College of Arts and Sciences, University of Pennsylvania, Philadelphia, PA, USA
| | - Jo Won Jung
- Division of Pediatric Cardiology, Center for Congenital Heart Disease, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jae Young Choi
- Division of Pediatric Cardiology, Center for Congenital Heart Disease, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
29
|
Kenny D, Eicken A, Dähnert I, Boudjemline Y, Sievert H, Schneider MBE, Gori T, Hijazi ZM. A randomized, controlled, multi‐center trial of the efficacy and safety of the Occlutech Figulla Flex‐II Occluder compared to the Amplatzer Septal Occluder for transcatheter closure of secundum atrial septal defects. Catheter Cardiovasc Interv 2018; 93:316-321. [DOI: 10.1002/ccd.27899] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 08/29/2018] [Accepted: 08/29/2018] [Indexed: 11/09/2022]
Affiliation(s)
- Damien Kenny
- Department of CardiologyOur Lady's Children's Hospital Dublin Ireland
| | | | - Ingo Dähnert
- Department of Pediatric Cardiology Heart CentreUniversity of Leipzig Leipzig Germany
| | - Younes Boudjemline
- Department of Pediatric Cardiology, Centre de reference des Malformations Cardiaques Congénitales ComplexesNecker Hospital Paris France
| | - Horst Sievert
- CardioVascular Center Frankfurt, FrankfurtGermany & Anglia Ruskin University Chelmsford United Kingdom
| | - Martin BE Schneider
- Department of Pediatric Cardiology, Charitè Medical CenterHumboldt University Berlin Germany
| | - Tommaso Gori
- Zentrum für Kardiologie, Kardiologie IUniversity Medical Center, and DZHK Standort Rhein‐Main Mainz Germany
| | - Ziyad M. Hijazi
- Sidra Cardiovascular Center of ExcellenceWeil Cornell Medical College Doha Qatar
| | | |
Collapse
|
30
|
Impact of modified techniques of transcatheter closure in large atrial septal defects (⩾30 mm) with anatomic complexities. Cardiol Young 2018; 28:1122-1133. [PMID: 30033909 DOI: 10.1017/s1047951118001099] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
OBJECTIVE The outcome of transcatheter closure in ostium secundum atrial septal defects is determined by the morphology of the defects. Modified techniques such as balloon assistance, pulmonary vein deployment, left atrial roof technique, and so on are used for circumventing the anatomic complexities and increasing the success rates. METHODS We planned a prospective study looking at the outcomes of transcatheter closure in secundum atrial septal defects with modified techniques in different anatomic complexities identified in transoesophageal echocardiography and their association with outcome of transcatheter closure. RESULTS Transcatheter closure was successful in 295 out of 346 (82%) patients with modified techniques. Balloon-assisted technique offered a success rate of 87%. The mean defect size was 34.7±2.78 mm (95% confidence interval (CI) 30.67-43.1 mm) with success and 40.16±4.5 mm (95% CI 32.16-44.7) with failure (p = 0.02). The mean total septal length was 38.11±0.63 (95% CI 35.21-40.56 mm) with success and 42.54±0.34 (95% CI 38.79-43.21 mm) with failure. The defect to septal ratios were 0.82 and 0.94 in success and failure groups, respectively (p=0.02). However, the absence of a retro-aortic margin, septal aneurysm, and multiple defects did not affect the success rate. Deficient inferior vena caval margin, deficient posterior margin, and size⩾40 mm had a high risk of failure with transcatheter closure. The odds ratio for procedural failure was 25.3 (4.3-143.8) in patients with malaligned septum, 8.3(1.4-48.5) with deficient inferior vena caval margin, and 4.1(2.5-19) for size⩾40 mm. CONCLUSIONS The modified techniques for device deployment offer substantial chances of success in transcatheter closure of secundum atrial septal defects with anatomical complexity (82%). Variants such as defect size of⩾40 mm and deficient inferior and posterior margins have high failure rates with a modified technique.
Collapse
|
31
|
Rigatelli G, Zuin M, Nghia NT. Interatrial shunts: technical approaches to percutaneous closure. Expert Rev Med Devices 2018; 15:707-716. [DOI: 10.1080/17434440.2018.1526674] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Affiliation(s)
- Gianluca Rigatelli
- Section of Congenital and Structural Heart Disease Interventions, Cardiovascular Diagnosis and Endoluminal Interventions Unit, Rovigo General Hospital, Rovigo, Italy
| | - Marco Zuin
- Section of Internal and Cardiopulmonary Medicine, Department of Medical Science, University of Ferrara, Ferrara, Italy
- Department of Cardiology, Rovigo General Hospital, Rovigo, Italy
| | - Nguyen Tuong Nghia
- Department of Interventional cardiology, Cho-Ray Hospital, Ho Chi minh City, Vietnam
| |
Collapse
|
32
|
Jung SY, Choi JY. Transcatheter closure of atrial septal defect: principles and available devices. J Thorac Dis 2018; 10:S2909-S2922. [PMID: 30305951 DOI: 10.21037/jtd.2018.02.19] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
There has been a remarkable improvement in the treatment strategy of secundum atrial septal defect (ASD) over the last few decades. Indebted to the improvement in device technology and procedural techniques, transcatheter closure of ASD is currently accepted as the treatment of choice in most patients with secundum ASD. Recent generation devices enable easy and safe deployment of device with the properties of adequate flexibility, re-capturability and repositioning. Use of biocompatible materials with improved device design and refined equipment finish may promote re-endothelialization and reduce potential damage to nearby structures. Most of currently available devices show excellent efficacy and comparable outcome with its own advantages and disadvantages. In addition to improvement of device properties and performance, there has been distinct improvement in procedural technique from numerous experiences of device closure of ASD. Nowadays there are well established principles regarding patient selection, pre-procedural evaluation, step-by-step details of procedure as well as post-procedural follow-up. However, an operator may encounter pitfalls in closing complex lesions such as large defect, rim deficiencies and multiple defects, so every operator has to be familiar with each available device, general principle as well as special issues for complex lesions.
Collapse
Affiliation(s)
- Se Yong Jung
- Division of Pediatric Cardiology, Center for Congenital Heart Disease, Severance Cardiovascular Hospital, Yonsei University Health System, Seoul, Korea
| | - Jae Young Choi
- Division of Pediatric Cardiology, Center for Congenital Heart Disease, Severance Cardiovascular Hospital, Yonsei University Health System, Seoul, Korea
| |
Collapse
|
33
|
Faccini A, Butera G. Atrial septal defect (ASD) device trans-catheter closure: limitations. J Thorac Dis 2018; 10:S2923-S2930. [PMID: 30305952 DOI: 10.21037/jtd.2018.07.128] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Transcatheter closure is a widespread technique used to treat secundum atrial septal defects (ASDs). When compared to surgery, it provides a less invasive approach with quicker recovery and reduced physical and psychological impact. Nowadays, almost 85-90% of all secundum ASD can be closed by using a transcatheter approach. However, several limitations may have a significant impact on the feasibility and success of percutaneous ASD closure. Limitations can be grouped as: (I) anatomical; (II) device-related; (III) associated defects and natural history associated issues; (IV) physiological; (V) complications. Physician should be aware of potential limits of percutaneous ASD closure.
Collapse
Affiliation(s)
- Alessia Faccini
- Department of Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Gianfranco Butera
- Department of Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| |
Collapse
|
34
|
Abstract
This report describes the first clinical experience with the new Occlutech Atrial Flow Regulator (AFR®) device for implementation of a late Fontan fenestration. The AFR® device secured a defined diameter of the fenestration without spontaneous re-occlusion of this extra-anatomic perforation. This ensured a permanent clinical improvement of our failing Fontan patient.
Collapse
|
35
|
Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept. Cardiol Young 2018; 28:955-960. [PMID: 29779498 DOI: 10.1017/s1047951118000586] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVES This study aimed to develop a method for retrieval of the new meshed nitinol atrial septal defect occluders - Ceraflex and Occlutech. BACKGROUND The newly developed atrial septal defect occluders have potential benefits considering implantation, but concerns regarding their removal in case of embolisation have been raised. METHODS Over 21 years, 1449 patients underwent interventional atrial septal defect occlusion in our institution. We reviewed the cases of embolisation of the device, developed a strategy for device removal, and tested it on the benchside and in animal tests. RESULTS In 11 patients (0.8%), the intended atrial septal defect occlusion was complicated by an embolisation of the device. In contrast to the Amplatzer septal occluders, retrieval of Occlutech devices larger than 16 mm with snare techniques was impossible. In benchside tests, this was confirmed and a new method for removal of large meshed devices was developed. This involved the commercially available Maslanka® biopsy forceps. The feasibility of this technique in vivo was tested in a pig model. During animal tests, using the Maslanka biopsy forceps it was possible to interventionally retrieve embolised Ceraflex and Occlutech devices of different sizes - 10, 16, 30, and 40 mm - into a 12-F sheath. CONCLUSION It was impossible to retrieve Occlutech and Ceraflex devices larger than 16 mm into a large sheath in vivo and during benchside tests. However, this was feasible on the bench and in vivo using the Maslanka biopsy forceps even with the largest available devices.
Collapse
|
36
|
Yang MC, Wu JR. Recent review of transcatheter closure of atrial septal defect. Kaohsiung J Med Sci 2018; 34:363-369. [PMID: 30063008 DOI: 10.1016/j.kjms.2018.05.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 05/02/2018] [Accepted: 05/04/2018] [Indexed: 01/11/2023] Open
Abstract
Atrial septal defect (ASD) is one of the two most common congenital heart diseases in children and adult. After the application of catheter intervention for ASD, this became an alternative treatment other than surgery from late 1990. In 2001, the procedure was further approved by the US Food and Drug Administration (FDA), and become the first choice for most cases of secundum type of ASD worldwide. The success rate is more than 98% in literature reviews, with low complication rates in percutaneous ASD closure. Major complications are around 1%, including device embolization, cardiac erosions, new-onset atrial arrhythmia, and other comorbidities. We reviewed indications for percutaneous secundum type ASD closure, technique, successful rate and major complications in this article. To complete the catheter intervention with difficult ASD conditions, various procedural techniques have been developed recently. We also report a challenging case by a current balloon-assisted technique for huge ASD closure.
Collapse
Affiliation(s)
- Ming-Chun Yang
- Department of Pediatrics, E-Da Hospital/I-Shou University, Kaohsiung, Taiwan
| | - Jiunn-Ren Wu
- Department of Pediatrics, E-Da Hospital/I-Shou University, Kaohsiung, Taiwan.
| |
Collapse
|
37
|
Jalal Z, Hascoët S, Gronier C, Godart F, Mauri L, Dauphin C, Lefort B, Lachaud M, Piot D, Dinet ML, Levy Y, Fraisse A, Ovaert C, Pillois X, Lusson JR, Petit J, Baruteau AE, Thambo JB. Long-Term Outcomes After Percutaneous Closure of Ostium Secundum Atrial Septal Defect in the Young. JACC Cardiovasc Interv 2018; 11:795-804. [DOI: 10.1016/j.jcin.2018.01.262] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 01/16/2018] [Accepted: 01/23/2018] [Indexed: 11/24/2022]
|
38
|
Abstract
Percutaneous closure is the treatment of choice for secundum-type atrial septal defects (ASD). Balloon sizing (BS) has been the method of choice for deciding on device size. Improved 2D- and 3D-transesophageal echocardiographic (TEE) imaging challenged the necessity of BS. Balloon sizing was performed with two additional techniques to measure the stretched dimension of the ASD. The 1st method uses a stiff guide wire which stretches the ASD and 2D TEE. The second technique uses 3D TEE. Two hundred and thirty-six patients with minimum 1-year follow-up were enrolled. The population was classified into three groups: BS (group 1) n = 90, 2D-TEE (group 2) n = 87, and 3D-TEE (group 3) n = 59. All groups showed a distinct correlation between the maximum baseline dimensions and the device size (R = 0.821). The relative expansion rate did not differ between BS and 3D-TEE. Group 2 (2D-TEE) showed a significantly lower expansion rate. Procedural success and complications did not differ statistically between the 3 groups. 2D TEE sizing was the simplest method without loss of accuracy. 3D sizing offers the advantage of accurate and fast shape assessment, but resulted in more undersizing. Accurate sizing of ASDs with a floppy septum remains a challenge.
Collapse
|
39
|
Abstract
Paradoxical embolism should be suspected in front of a clinical phenomenon of thromboembolism associated with an anatomical right-to-left shunt. Others potential cardiac sources of thromboembolism must be ruled out. Strokes constitute the most frequent clinical manifestations of paradoxical embolism. Right-to-left left shunts are in connection with intracardiac defects (atrial septal defect and patent foramen ovale) or pulmonary arteriovenous malformations. The probability that a discovered PFO is stroke-related can be evaluated by a score. Therapeutic approaches for secondary prevention of recurrent stroke include antithrombotic and/or percutaneous treatments. The choice strategy begins to be clearer with the recent results of randomized controlled studies.
Collapse
Affiliation(s)
- P Aubry
- Département de cardiologie, groupe hospitalier Bichat-Claude-Bernard, Assistance publique-Hôpitaux de Paris, 46, rue Henri-Huchard, 75018 Paris, France; Service de cardiologie, centre hospitalier de Gonesse, 95500 Gonesse, France.
| | - H Demian
- Service de cardiologie, centre hospitalier de Gonesse, 95500 Gonesse, France
| | - E Brochet
- Département de cardiologie, groupe hospitalier Bichat-Claude-Bernard, Assistance publique-Hôpitaux de Paris, 46, rue Henri-Huchard, 75018 Paris, France
| | - J-M Juliard
- Département de cardiologie, groupe hospitalier Bichat-Claude-Bernard, Assistance publique-Hôpitaux de Paris, 46, rue Henri-Huchard, 75018 Paris, France
| |
Collapse
|
40
|
Abstract
BACKGROUND Transcatheter device closure has become the established standard of care for suitable atrial septal defects. Device erosion has been a recent focus and has prompted changes in the Instructions for Users documentation released by device companies. We reviewed our entire local experience with atrial septal defect device closure, focussing on the evolution of this procedure in our centre and particularly on complications. METHODS We carried out a retrospective review of 581 consecutive patients undergoing attempted transcatheter device closure of an atrial septal defect in Auckland from December 1997 to June 2014. We reviewed all complications recorded and compared our outcomes with the current literature. We sought to understand the impact of the evolution in recommendations and clinical practice on patient outcomes in our programme. RESULTS There were a total of 24 complications (4.1%), including 10 device embolisations (1.7%), nine arrhythmias (1.5%), two significant vascular access-related complications (0.3%), one device erosion (0.2%), one malposed device (0.2%), and one probable wire perforation of the left atrial appendage (0.2%). There was one mortality related to device embolisation. All device embolisations occurred following the change in Instructions for Users after publication of the first device erosion report in 2004. This increase in embolisation rate was statistically significant (p-value 0.015). CONCLUSIONS In our series, the incidence of device embolisation was higher than that anticipated, with a significant increase following changes to the Instructions for Users. This highlights the need for ongoing data collection on complication incidence and for ongoing review of the impact of changes in clinical practice on complication rates.
Collapse
|
41
|
Tada N, Mizutani Y, Matsumoto T, Sakurai M, Ootomo T. Transcatheter closure of an atrial septal defect with high risk of erosion using a Figulla Flex II atrial septal defect occluder. Cardiovasc Interv Ther 2017; 32:436-439. [PMID: 28108954 PMCID: PMC5617866 DOI: 10.1007/s12928-017-0457-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Accepted: 01/10/2017] [Indexed: 11/30/2022]
Abstract
An 85-year-old man with a high risk for open heart surgery underwent a percutaneous closure of an atrial septal defect that lacked adequate aortic and superior rims. To avoid the risk for erosion, a Figulla Flex II ASD occluder was selected for the procedure. Implantation was successful, and no complications were observed during the 6 months of follow-up.
Collapse
Affiliation(s)
- Norio Tada
- Department of Cardiology, Sendai Kousei Hospital, 4-15 Hirosemachi, Aoba, Sendai, Miyagi, 980-0873, Japan.
| | - Yukiko Mizutani
- Department of Cardiology, Sendai Kousei Hospital, 4-15 Hirosemachi, Aoba, Sendai, Miyagi, 980-0873, Japan
| | - Takashi Matsumoto
- Department of Cardiology, Sendai Kousei Hospital, 4-15 Hirosemachi, Aoba, Sendai, Miyagi, 980-0873, Japan
| | - Mie Sakurai
- Department of Cardiology, Sendai Kousei Hospital, 4-15 Hirosemachi, Aoba, Sendai, Miyagi, 980-0873, Japan
| | - Tatsushi Ootomo
- Department of Cardiology, Sendai Kousei Hospital, 4-15 Hirosemachi, Aoba, Sendai, Miyagi, 980-0873, Japan
| |
Collapse
|
42
|
Grohmann J, Wildberg C, Zartner P, Abu-Tair T, Tarusinov G, Kitzmüller E, Schmoor C, Stiller B, Kampmann C. Multicenter midterm follow-up results using the gore septal occluder for atrial septal defect closure in pediatric patients. Catheter Cardiovasc Interv 2016; 89:E226-E232. [DOI: 10.1002/ccd.26881] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Revised: 10/14/2016] [Accepted: 11/13/2016] [Indexed: 11/05/2022]
Affiliation(s)
- Jochen Grohmann
- Department of Congenital Heart Defects and Pediatric Cardiology; Heart Center, University of Freiburg; Freiburg Germany
| | - Christian Wildberg
- Department of Congenital Heart Defects and Pediatric Cardiology; Heart Center, University of Freiburg; Freiburg Germany
| | - Peter Zartner
- Department of Cardiology; German Pediatric Heart Center; Sankt Augustin Germany
| | - Tariq Abu-Tair
- Department of Pediatric Cardiology and Congenital Heart Disease; University Children's Hospital, University Medicine Mainz; Mainz Germany
| | - Gleb Tarusinov
- Department for Pediatric Cardiology and Congenital Heart Disease; Heart Center Duisburg; Duisburg Germany
| | - Erwin Kitzmüller
- Department of Pediatric Cardiology; Medical University of Vienna; Vienna Austria
| | - Claudia Schmoor
- Faculty of Medicine; Clinical Trials Unit, Medical Center - University of Freiburg; Freiburg Germany
| | - Brigitte Stiller
- Department of Congenital Heart Defects and Pediatric Cardiology; Heart Center, University of Freiburg; Freiburg Germany
| | - Christoph Kampmann
- Department of Pediatric Cardiology and Congenital Heart Disease; University Children's Hospital, University Medicine Mainz; Mainz Germany
| |
Collapse
|
43
|
Shebani SO, Rehman R, Taliotis D, Magee A, Hayes NJ, Baspinar O, Martínez Z, Haas N, Duke C. Techniques for transcatheter retrieval of the occlutech ASD device United Kingdom-European multicenter report. Catheter Cardiovasc Interv 2016; 89:690-698. [PMID: 27860188 DOI: 10.1002/ccd.26838] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 09/09/2016] [Accepted: 10/12/2016] [Indexed: 11/09/2022]
Abstract
AIMS To gather current experience in Occlutech ASD device retrieval, to determine whether snaring is an effective technique and to highlight alternative retrieval techniques; METHODS AND RESULTS: United Kingdom and European Occlutech ASD device implanters reported their experience in dealing with device embolization and retrieval. Six operators reported 12 retrieval cases. Retrieval was successful in 92% (11/12), although in most cases it was not straightforward and required multiple attempts using different techniques and equipment. When each different technique or equipment combination was considered separately, there were a total of 23 retrieval attempts. Fifteen attempts involved snaring the ball on the right atrial disc of the device ("the RA pin"). In 12/15 of these attempts the snare slipped off the RA pin. In 8/15 attempts snaring eventually failed. In two cases retrieval was facilitated by elongating the device in a blood vessel. In three cases retrieval was achieved by grasping the RA pin with the jaws of the Occlutech Flex II delivery cable; CONCLUSIONS: Snares do not grip the RA pin sufficiently to reliably retrieve the device. Funnelling the device into a blood vessel or grasping the RA pin with the jaws of the delivery cable may be successful alternatives. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Suhair O Shebani
- Department of Congenital Heart Disease, Glenfield Hospital, University Hospitals of Leicester, Leicester, United Kingdom
| | - Rizwan Rehman
- Department of Congenital Heart Disease, Glenfield Hospital, University Hospitals of Leicester, Leicester, United Kingdom
| | - Demetris Taliotis
- Department of Congenital Heart Disease, University Hospitals of Bristol, Bristol, United Kingdom
| | - Alan Magee
- Department of Congenital Heart Disease, University of Southampton NHS Foundation Trust, United Kingdom
| | - Nicholas J Hayes
- Department of Congenital Heart Disease, University of Southampton NHS Foundation Trust, United Kingdom
| | - Osman Baspinar
- Department of Paediatric Cardiology, Gaziantep University Medical Faculty, Gaziantep, Turkey
| | - Zunzunegui Martínez
- Department of Paediatric Cardiology, Gregorio Maranon General University Hospital, Madrid, Spain
| | - Nikolaus Haas
- Department of Paediatric Cardiology and Paediatric Intensive Care, Ludwig Maximilians University Munich, Germany
| | - Christopher Duke
- Department of Congenital Heart Disease, Sheikh Khalifa Medical City, Abu Dhabi, United Arab Emirates
| |
Collapse
|
44
|
Amedro P, Soulatges C, Fraisse A. Infective endocarditis after device closure of atrial septal defects: Case report and review of the literature. Catheter Cardiovasc Interv 2016; 89:324-334. [PMID: 27641431 DOI: 10.1002/ccd.26784] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 08/15/2016] [Indexed: 11/08/2022]
Abstract
We report a case of late infective endocarditis in an 8-year-old boy 3 years after transcatheter closure of an atrial septal defect with the Amplatzer Atrial Septal Occluder Device. Echocardiography showed a very thick pannus lining the left atrial disc of the prosthesis, with some mobile elements. MRI showed several cerebral microemboli. The patient had dental caries and blood cultures found Staphylococcus aureus. Patient was treated with gentamicin and oxacillin before surgical removal of the prosthesis. Twenty-one cases of infective endocarditis after atrial defect device closure have been reported in the literature (13 ostium secundum ASD and 8 patent foramen ovale). Seven pediatric cases were reported. S. aureus was the most frequent bacterium. Antibiotics were administered in all cases and most patients (n = 18) underwent surgical removal of the device. Incomplete endothelialization of the prosthesis was a suggested mechanism. Two patients died after surgery. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Pascal Amedro
- Pediatric and Congenital Cardiology Department, M3C Regional Center, University Hospital, Montpellier, France.,Physiology and Experimental Biology of Heart and Muscles Laboratory - PHYMEDEXP, UMR CNRS 9214 - INSERM U1046, Montpellier, France
| | - Camille Soulatges
- Pediatric and Congenital Cardiology Department, M3C Regional Center, University Hospital, Montpellier, France
| | - Alain Fraisse
- Pediatric Cardiology Service, Royal Brompton and Harefield Hospital Trust, London, United Kingdom
| |
Collapse
|