1
|
Bruckheimer E, Steiner K, Barak-Corren Y, Slanovic L, Levinzon M, Lowenthal A, Amir G, Dagan T, Birk E. The Amplatzer duct occluder (ADOII) and Piccolo devices for patent ductus arteriosus closure: a large single institution series. Front Cardiovasc Med 2023; 10:1158227. [PMID: 37215550 PMCID: PMC10193946 DOI: 10.3389/fcvm.2023.1158227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 04/10/2023] [Indexed: 05/24/2023] Open
Abstract
Purpose Evaluate Piccolo and ADOII devices for transcatheter patent ductus arteriosus (PDA) closure. Piccolo has smaller retention discs reducing risk of flow disturbance but residual leak and embolization risk may increase. Methods Retrospective review of all patients undergoing PDA closure with an Amplatzer device between January 2008 and April 2022 in our institution. Data from the procedure and 6 months follow-up were collected. Results 762 patients, median age 2.6 years (range 0-46.7) years and median weight 13 kg (range 3.5-92) were referred for PDA closure. Overall, 758 (99.5%) had successful implantation: 296 (38.8%) with ADOII, 418 (54.8%) with Piccolo, and 44 (5.8%) with AVPII. The ADOII patients were smaller than the Piccolo patients (15.8 vs. 20.5 kg, p < 0.001) and with larger PDA diameters (2.3 vs. 1.9 mm, p < 0.001). Mean device diameter was similar for both groups. Closure rate at follow-up was similar for all devices ADOII 295/296 (99.6%), Piccolo 417/418 (99.7%), and AVPII 44/44 (100%). Four intraprocedural embolizations occurred during the study time period: two ADOII and two Piccolo. Following retrieval the PDA was closed with an AVPII in two cases, ADOI in one case and with surgery in the fourth case. Mild stenosis of the left pulmonary artery (LPA) occurred in three patients with ADOII devices (1%) and one patient with Piccolo device (0.2%). Severe LPA stenosis occurred in one patient with ADOII (0.3%) and one with AVPII device (2.2%). Conclusions ADOII and Piccolo are safe and effective for PDA closure with a tendency to less LPA stenosis with Piccolo. There were no cases of aortic coarctation related to a PDA device in this study.
Collapse
Affiliation(s)
- Elchanan Bruckheimer
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Kristoffer Steiner
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Yuval Barak-Corren
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Leonel Slanovic
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Michael Levinzon
- Section of Pediatric Anesthesiology, Schneider Children’s, Medical Center of Israel, Petach Tikva, Israel
| | - Alexander Lowenthal
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Gabriel Amir
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Tamir Dagan
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| | - Einat Birk
- Section of Pediatric Cardiology, Schneider Children’s Medical, Center of Israel, Petach Tikva, Israel
| |
Collapse
|
2
|
Diab KA, Boujemline Y, Hijazi ZM. Update on shunt closure in neonates and infants. Expert Rev Cardiovasc Ther 2021; 19:475-492. [PMID: 33899641 DOI: 10.1080/14779072.2021.1922079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Introduction: Cardiac defects that result in shunting are the most common types of congenital heart anomalies. Although these lesions can be simple, they can cause significant hemodynamic changes and can be challenging to manage in neonates and infants. Over the recent decades, the development of new transcatheter techniques and devices has made it safe and feasible to manage such defects when indicated, even in the smallest of patients. Understanding these interventional procedures is essential in order to manage those patients.Areas covered: In this article, we review the techniques and experience for closure of atrial septal defects, ventricular septal defects, patent ductus aarteriosus,as well as coronary arteriovenous malformations and fistulas in neonates and infants. Literature review of PubMed articles was performed through January 2021, with focus on the latest data and results of the usage of interventional techniques in treating these lesions specifically in this age-group.Expert opinion: Significant shunting lesions can be particularly challenging to manage in neonates and infants. Newer lower profile devices will likely continue to be developed in the future, allowing their use for transcatheter interventions in even smaller patients and those with more complex anatomy.
Collapse
Affiliation(s)
- Karim A Diab
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar
| | - Younes Boujemline
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar
| | - Ziyad M Hijazi
- Department of Pediatrics, Sidra Heart Center, Sidra Medicine, Doha, Qatar.,Weill Cornell Medical College, Doha, Qatar.,Weill Cornell Medical College, New York, NY, USA
| |
Collapse
|
3
|
Percutaneous Closure of Patent Ductus Arteriosus in Infants 1.5 kg or Less: A Meta-Analysis. J Pediatr 2021; 230:84-92.e14. [PMID: 33098843 DOI: 10.1016/j.jpeds.2020.10.035] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To investigate technical success and safety of percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. STUDY DESIGN A systematic review and meta-analysis was performed. Data sources included Scopus, Web of Science, Embase, CINAHL, Cochrane, and PubMed from inception to April 2020. Publications were included if they had a clear definition of the intervention as percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. Data extraction was independently performed by multiple observers. Primary outcome was technical success and secondary outcomes were adverse events (AEs). Subgroup analysis was performed in infants ≤6.0 kg. Data were pooled by using a random-effects model. RESULTS We included 28 studies, including 373 infants ≤1.5 kg and 69 studies enrolling 1794 infants ≤6.0 kg. In patients ≤1.5 kg, technical success was 96% (95% CI, 93%-98%; P = .16; I2 = 23%). The overall incidence of AE was 27% (95% CI, 17%-38%; P < .001; I2 = 70%) and major AEs was 8% (95% CI, 5%-10%; P = .63; I2 = 0%). There were 5 deaths related to the procedure (2%; 95% CI, 1%-4%; P = .99; I2 = 0%); 4 of these deaths occurred in infants <0.8 kg. The probability of technical failure was inversely related to age at the time of the procedure (OR, 0.9; 95% CI, 0.830-0.974; P = .009). Weight at intervention has decreased over time and procedural success has increased. CONCLUSIONS Percutaneous patent ductus arteriosus closure is feasible in infants ≤1.5 kg with few major AEs. The procedural success rate is high, despite performing the intervention in smaller patients. PROSPERO REGISTRATION CRD42020145230.
Collapse
|
4
|
Sathanandam SK, Gutfinger D, O'Brien L, Forbes TJ, Gillespie MJ, Berman DP, Armstrong AK, Shahanavaz S, Jones TK, Morray BH, Rockefeller TA, Justino H, Nykanen DG, Zahn EM. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams. Catheter Cardiovasc Interv 2020; 96:1266-1276. [PMID: 32433821 PMCID: PMC7754477 DOI: 10.1002/ccd.28973] [Citation(s) in RCA: 81] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 04/23/2020] [Accepted: 05/04/2020] [Indexed: 01/08/2023]
Abstract
Objectives Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. Background The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. Methods This was a single arm, prospective, multicenter, non‐randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6‐month follow‐up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow‐up. Results The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. Conclusions This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.
Collapse
Affiliation(s)
- Shyam K Sathanandam
- LeBonheur Children's Hospital, University of Tennessee, Memphis, Tennessee, USA
| | - Dan Gutfinger
- Abbott Structural Heart, Santa Clara, California, USA
| | - Laura O'Brien
- Abbott Structural Heart, Santa Clara, California, USA
| | | | | | | | | | | | | | | | | | | | | | - Evan M Zahn
- Cedars-Sinai Medical Center, Los Angeles, California, USA
| |
Collapse
|
5
|
Maksymenko AV, Kuzmenko YL, Dovhaliuk AA, Motrechko OO, Herrmann FE, Haas NA, Lehner A. Percutaneous closure of patent ductus arteriosus with the Nit-Occlud ® patent ductus arteriosus device in 268 consecutive cases. Ann Pediatr Cardiol 2019; 12:206-211. [PMID: 31516276 PMCID: PMC6716305 DOI: 10.4103/apc.apc_151_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Background The pfm Nit-Occlud® patent ductus arteriosus (PDA) device is well established for interventional closure of PDA. However, there are still limited data concerning its efficacy and follow-up in larger patient groups. Aims This study aimed to evaluate the safety and efficacy of the Nit-Occlud® PDA device, implanted both through transpulmonary and transaortic approach, in a large cohort. Methods From July 2008 to December 2015, 268 consecutive patients were admitted for transcatheter closure of a PDA and were treated with the Nit-Occlud® coil. Clinical, echocardiographic, and angiographic data were evaluated. Results The median age was 5.2 years (range, 5 months to 62 years), and the median weight was 19.3 kg (range: 5.5-97 kg). Ten (3.7%) patients had weight <10 kg. The most common ductus types treated were Krichenko Type E and A (44.0% and 33.2%, respectively). Twelve (4.5%) patients were treated for residual shunting after surgical PDA closure. The median diameter at the narrowest point was 1.5 mm (range: 0.4-4 mm), the median size of the ampulla was 5 mm (range: 1-15 mm), and the median length was 9 mm (range: 2-25 mm). Device implantation could be successfully achieved in all cases. Closure rates documented immediately after the procedure, at 3-10 days, 1 month, and 6 months after intervention were 62%, 95.1%, 97.8%, and 98.5%, respectively. With the exception of one minor thromboembolic event, there were no procedure-related complications. Conclusion Closure of PDA with various anatomic variations and sizes can be performed effectively and safely using the Nit-Occlud® coil.
Collapse
Affiliation(s)
- Andrii V Maksymenko
- Department of Interventional Cardiology, Ukrainian Children's Cardiac Center, Kyiv, Ukraine
| | - Yulia L Kuzmenko
- Department of Interventional Cardiology, Ukrainian Children's Cardiac Center, Kyiv, Ukraine
| | - Arkadii A Dovhaliuk
- P. L. Shupyk National Medical Academy of Postgraduate Education, Kyiv, Ukraine
| | - Oleksandra O Motrechko
- Department of Interventional Cardiology, Ukrainian Children's Cardiac Center, Kyiv, Ukraine
| | - Florian E Herrmann
- Department of Cardiac Surgery, Ludwig Maximilians University, Klinikum der Universität München, Munich, Germany
| | - Nikolaus A Haas
- Department of Pediatric Cardiology and Intensive Care, Ludwig Maximilians University, Klinikum der Universität München, Munich, Germany
| | - Anja Lehner
- Department of Pediatric Cardiology and Intensive Care, Ludwig Maximilians University, Klinikum der Universität München, Munich, Germany
| |
Collapse
|
6
|
Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes. Pediatr Cardiol 2018; 39:627-632. [PMID: 29453685 DOI: 10.1007/s00246-018-1828-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2017] [Accepted: 02/01/2018] [Indexed: 10/18/2022]
Abstract
Transcatheter closure of arterial duct (AD) remains challenging in low-weight patients and using Amplatzer Duct Occluder devices is still considered off-label in infants < 6 kg. This study aimed to report a large, single-center experience of percutaneous AD closure in infants < 6 kg as well as to compare the most frequently used devices, Amplatzer Duct Occluder type I (ADO I) and Amplatzer Duct Occluder type II Additional Sizes devices (ADO II-AS) (St. Jude Medical Corp, St. Paul, MN, USA). From March 2000 to March 2017, among the 762 patients submitted to percutaneous closure of AD at our Institution, 33 were infants < 6 kg (age 4.8 ± 2.1 months; weight 5.0 ± 0.9 kg). Fourteen patients (45%) underwent ADO I (Group I) and 19 patients ADO II-AS (Group II) device implantation. AD diameter was 2.6 ± 0.8 (range 1.5-4.0) mm resulting in QP/QS of 2.6 ± 0.0.9 (range 1.1-4.5). Successful device deployment was achieved in all patients without procedural morbidity or mortality. Procedural and fluoroscopy times were not significantly different between the groups. However, total X-ray absorbed dose was significantly higher in Group I (121 ± 69 vs 29 ± 16 mGy/cm2, p < 0.01). Immediate, 24 h, and mid-term (46 ± 37 months, median 39) complete occlusion were recorded in 72.7, 90.9, and 97% of patients, respectively without significant difference between the groups. In conclusion, transcatheter closure of AD with Amplatzer Duct Occluder devices is feasible, safe, and effective also in infants less than 6 kg, without significant difference between the most commonly used devices, namely, ADO I and ADO II-AS.
Collapse
|