1
|
Moya-Lopez C, González-Fuentes J, Bravo I, Chapron D, Bourson P, Alonso-Moreno C, Hermida-Merino D. Polylactide Perspectives in Biomedicine: From Novel Synthesis to the Application Performance. Pharmaceutics 2022; 14:pharmaceutics14081673. [PMID: 36015299 PMCID: PMC9415503 DOI: 10.3390/pharmaceutics14081673] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/26/2022] [Accepted: 07/28/2022] [Indexed: 11/24/2022] Open
Abstract
The incessant developments in the pharmaceutical and biomedical fields, particularly, customised solutions for specific diseases with targeted therapeutic treatments, require the design of multicomponent materials with multifunctional capabilities. Biodegradable polymers offer a variety of tailored physicochemical properties minimising health adverse side effects at a low price and weight, which are ideal to design matrices for hybrid materials. PLAs emerge as an ideal candidate to develop novel materials as are endowed withcombined ambivalent performance parameters. The state-of-the-art of use of PLA-based materials aimed at pharmaceutical and biomedical applications is reviewed, with an emphasis on the correlation between the synthesis and the processing conditions that define the nanostructure generated, with the final performance studies typically conducted with either therapeutic agents by in vitro and/or in vivo experiments or biomedical devices.
Collapse
Affiliation(s)
- Carmen Moya-Lopez
- Laboratoire Matériaux Optiques Photonique et Systèmes (LMOPS), CentraleSupélec, Université de Lorraine, 57000 Metz, France
| | - Joaquín González-Fuentes
- Centro Regional de Investigaciones Biomédicas (CRIB), 02008 Albacete, Spain
- Facultad de Farmacia de Albacete, Universidad de Castilla-La Mancha, 02008 Albacete, Spain
| | - Iván Bravo
- Facultad de Farmacia de Albacete, Universidad de Castilla-La Mancha, 02008 Albacete, Spain
- Unidad NanoCRIB, Centro Regional de Investigaciones Biomédicas, 02008 Albacete, Spain
| | - David Chapron
- Laboratoire Matériaux Optiques Photonique et Systèmes (LMOPS), CentraleSupélec, Université de Lorraine, 57000 Metz, France
| | - Patrice Bourson
- Laboratoire Matériaux Optiques Photonique et Systèmes (LMOPS), CentraleSupélec, Université de Lorraine, 57000 Metz, France
| | - Carlos Alonso-Moreno
- Facultad de Farmacia de Albacete, Universidad de Castilla-La Mancha, 02008 Albacete, Spain
- Unidad NanoCRIB, Centro Regional de Investigaciones Biomédicas, 02008 Albacete, Spain
| | - Daniel Hermida-Merino
- DUBBLE@ESRF BP CS40220, 38043 Grenoble, France
- Departamento de Física Aplicada, CINBIO, Lagoas-Marcosende Campus, Universidade de Vigo, 36310 Vigo, Spain
- Correspondence: ; Tel.: +33-(0)476882375
| |
Collapse
|
2
|
Tijssen RYG, Annink ME, Kraak RP, Koch KT, Baan J, Vis MM, Piek JJ, Henriques JPS, de Winter RJ, Beijk MAM, Wykrzykowska JJ. The Absorb bioresorbable vascular scaffold in real-world practice: long-term follow-up of the AMC Single Centre Real World PCI Registry. Neth Heart J 2020; 28:153-160. [PMID: 31953774 PMCID: PMC7052095 DOI: 10.1007/s12471-019-01362-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Bioresorbable scaffolds have been introduced to overcome the shortcomings of drug-eluting stents. Higher rates of device thrombosis, however, have been reported up to 3 years after implantation of the Absorb bioresorbable vascular scaffold (BVS). In the current article, we therefore report long-term clinical outcomes of the AMC Absorb Registry. METHODS AND RESULTS In the AMC Absorb Registry, all patients who underwent a percutaneous coronary intervention with Absorb BVS implantation between 30 August 2012 and 5 August 2013 at the Amsterdam University Medical Centre-Academic Medical Centre were included. The composite endpoint of this analysis was target-vessel failure (TVF). The median follow-up of the study cohort of the AMC Absorb Registry was 1534 days. At the time of the cross-sectional data sweep the clinical status at 4 years was known in 124 of 135 patients (91.9%). At long-term follow-up, the composite endpoint of TVF had occurred in 27 patients. The 4‑year Kaplan-Meier estimate of TVF was 19.8%. At 4 years cardiac death had occurred in 4 patients (3.2%) and target-vessel myocardial infarction in 9 (6.9%) patients. Definite scaffold thrombosis occurred in 5 (3.8%) patients. We found 1 case of very late scaffold thrombosis that occurred at 911 days after device implantation in a patient who was not on dual anti-platelet therapy. CONCLUSION In a patient population reflecting routine clinical practice, we found that cases of TVF continued to accrue beyond 2 years after Absorb BVS implantation.
Collapse
Affiliation(s)
- R Y G Tijssen
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - M E Annink
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - R P Kraak
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands.,Department of Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
| | - K T Koch
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - J Baan
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - M M Vis
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - J J Piek
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - J P S Henriques
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - R J de Winter
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - M A M Beijk
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands
| | - J J Wykrzykowska
- Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Heart Centre, University of Amsterdam, Amsterdam, The Netherlands.
| |
Collapse
|
3
|
Kerkmeijer LS, Tijssen RYG, Hofma SH, van der Schaaf RJ, Arkenbout KE, Kraak RP, Weevers A, Piek JJ, de Winter RJ, Tijssen JG, Henriques JP, Wykrzykowska JJ, Ijsselmuiden A, Kauer F, Beijk MA, Vis M, Koch K. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in routine PCI: three-year clinical outcomes from the AIDA trial. EUROINTERVENTION 2019; 15:603-606. [DOI: 10.4244/eij-d-19-00325] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
4
|
Incidental Finding of Strut Malapposition Is a Predictor of Late and Very Late Thrombosis in Coronary Bioresorbable Scaffolds. J Clin Med 2019; 8:jcm8050580. [PMID: 31035602 PMCID: PMC6571797 DOI: 10.3390/jcm8050580] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 04/16/2019] [Accepted: 04/25/2019] [Indexed: 12/11/2022] Open
Abstract
Malapposition is a common finding in stent and scaffold thrombosis (ScT). Evidence from studies with prospective follow-up, however, is scarce. We hypothesized that incidental observations of strut malapposition might be predictive of late ScT during subsequent follow-up. One hundred ninety-seven patients were enrolled in a multicentre registry with prospective follow-up. Optical coherence tomography (OCT), performed in an elective setting, was available in all at 353 (0–376) days after bioresorbable scaffold (BRS) implantation. Forty-four patients showed evidence of malapposition that was deemed not worthy of intervention. Malapposition was not associated with any clinical or procedural parameter except for a higher implantation pressure (p = 0.0008). OCT revealed that malapposition was associated with larger vessel size, less eccentricity (all p < 0.01), and a tendency for more uncovered struts (p = 0.06). Late or very late ScT was recorded in seven of these patients 293 (38–579) days after OCT. OCT-diagnosed malapposition was a predictor of late and very late scaffold thrombosis (p < 0.001) that was independent of the timing of diagnosis. We provide evidence that an incidental finding of malapposition—regardless of the timing of diagnosis of the malapposition—during an elective exam is a predictor of late and very late ScT. Our data provide a rationale to consider prolonged dual antiplatelet therapy if strut malapposition is observed.
Collapse
|
5
|
Rahim HM, Shlofmitz E, Gore A, Hakemi E, Mintz GS, Maehara A, Jeremias A, Ben-Yehuda O, Stone GW, Shlofmitz RA, Ali ZA. IVUS- Versus OCT-Guided Coronary Stent Implantation: a Comparison of Intravascular Imaging for Stent Optimization. CURRENT CARDIOVASCULAR IMAGING REPORTS 2018. [DOI: 10.1007/s12410-018-9475-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
6
|
Tijssen RYG, Kraak RP, Hofma SH, van der Schaaf RJ, Arkenbout EK, Weevers A, Elias J, van Dongen IM, Koch KT, Baan J, Vis M, de Winter RJ, Piek JJ, Tijssen JG, Henriques JP, Wykrzykowska JJ. Complete two-year follow-up with formal non-inferiority testing on primary outcomes of the AIDA trial comparing the Absorb bioresorbable scaffold with the XIENCE drug-eluting metallic stent in routine PCI. EUROINTERVENTION 2018; 14:e426-e433. [DOI: 10.4244/eij-d-18-00335] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|