1
|
Gallo F, Gallone G, Kim WK, Reifart J, Veulemans V, Zeus T, Toggweiler S, De Backer O, Søndergaard L, De Marco F, Regazzoli D, Reimers B, Muntané-Carol G, Estevez-Loureiro R, Hernandez U, Moscarelli M, Airale L, D'Ascenzo F, Armario X, Mylotte D, Bhadra OD, Conradi L, Donday LAM, Nombela-Franco L, Barbanti M, Reddavid C, Criscione E, Brugaletta S, Nicolini E, Piva T, Tzanis G, Ronco F, Barbierato M, Rodes-Cabau J, Mangieri A, Colombo A, Giannini F. Procedural outcomes of the 34 mm EvolutR Transcatheter valve in a real-world population insights from the HORSE multicenter collaborative registry. Int J Cardiol 2022; 361:55-60. [PMID: 35500820 DOI: 10.1016/j.ijcard.2022.04.079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 04/23/2022] [Accepted: 04/27/2022] [Indexed: 01/07/2023]
Abstract
OBJECTIVES The aim of this study was to evaluate outcomes of real-world patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with the 34 mm Evolut R (Medtronic, Minneapolis, Minnesota). BACKGROUND Larger aortic annulus has been associated with increased incidence of paravalvular leaks (PVLs) after TAVR. However, little is known, so far, about the performance of the 34 mm Evolut R in this setting. METHODS From the multicenter, international, retrospective Horizontal Aorta in Transcatheter Self-expanding Valves (HORSE) registry, including patients who underwent TAVR for native severe AS, we selected patients treated with the 34 mm Evolut R evaluating procedural characteristics and VARC-2 defined device success. We also compared 34 mm Evolut R with other Evolut R sizes. RESULTS Among the 4434 patients included in the registry, 572 (13%) received the 34 mm Evolut R valve. Mean age was 80.8 ± 6.5 years and the median STS PROM score was 4 [interquartile range 2-6]. Device success was achieved in 87.4% with 7.7% of PVLs; moreover, the rate of permanent pacemaker implantation (PPMI) was 22.4%. Patients who underwent 34 mm Evolut R implantation experienced more in-hospital permanent pacemaker implantation (22.4% vs. 15%; p < 0.001). At multivariate analysis, 34 mm Evolut R did not affect device success (OR: 0.81 [0.60-1.09]; p = 0.151). Device success was consistent with other THVs sizes (87.4% vs. 89.6%; p = 0.157). CONCLUSIONS THV replacement in patients requiring 34 mm Evolut R has an acceptable performance. Compared to other Medtronic sizes it demonstrated to be comparable in terms of device success, despite an increased rate of pacemaker implantation.
Collapse
Affiliation(s)
- Francesco Gallo
- Interventional Cardiology, Department of Cardio-Thoracic and Vascular Sciences, Ospedale dell'Angelo, AULSS3 Serenissima, Mestre, Venezia, Italy
| | - Guglielmo Gallone
- Azienda Ospedaliera Universitaria Città della Salute e della Scienza di Torino, Turin, Italy
| | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart and Thorax Centre, Bad Nauheim, Germany
| | - Jörg Reifart
- Department of Cardiology, Kerckhoff Heart and Thorax Centre, Bad Nauheim, Germany
| | - Verena Veulemans
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Düsseldorf, Germany
| | - Tobias Zeus
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Düsseldorf, Germany
| | | | - Ole De Backer
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Lars Søndergaard
- Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Federico De Marco
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | | | - Bernhard Reimers
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | | | | | - Ubaldo Hernandez
- Interventional Cardiology Unit, Hospital Álvaro Cunqueiro, Vigo, Spain
| | - Marco Moscarelli
- Department of Cardiovascular Surgery, GVM Care & Research, Bari, Italy
| | - Lorenzo Airale
- Azienda Ospedaliera Universitaria Città della Salute e della Scienza di Torino, Turin, Italy
| | - Fabrizio D'Ascenzo
- Azienda Ospedaliera Universitaria Città della Salute e della Scienza di Torino, Turin, Italy
| | - Xavier Armario
- Department of Cardiology, National University of Ireland, Galway, (NUIG), Galway, Ireland
| | - Darren Mylotte
- Department of Cardiology, National University of Ireland, Galway, (NUIG), Galway, Ireland
| | - Oliver Daniel Bhadra
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Lenard Conradi
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | | | - Luis Nombela-Franco
- Cardiovascular Institute, Hospital Clínico San Carlos, IdISSC, Madrid, Spain
| | - Marco Barbanti
- Division of Cardiology, A.O.U. Policlinico-Vittorio Emanuele, Catania, Italy
| | - Claudia Reddavid
- Division of Cardiology, A.O.U. Policlinico-Vittorio Emanuele, Catania, Italy
| | - Enrico Criscione
- Division of Cardiology, A.O.U. Policlinico-Vittorio Emanuele, Catania, Italy
| | - Salvatore Brugaletta
- Cardiovascular Institute, Hospital Clinic, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Elisa Nicolini
- Interventional Cardiology, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Tommaso Piva
- Interventional Cardiology, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Giorgos Tzanis
- Department of Interventional Cardiology, Henry Dunant Hospital Center, Athens, Greece
| | - Federico Ronco
- Interventional Cardiology, Department of Cardio-Thoracic and Vascular Sciences, Ospedale dell'Angelo, AULSS3 Serenissima, Mestre, Venezia, Italy
| | - Marco Barbierato
- Interventional Cardiology, Department of Cardio-Thoracic and Vascular Sciences, Ospedale dell'Angelo, AULSS3 Serenissima, Mestre, Venezia, Italy
| | - Josep Rodes-Cabau
- Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - Antonio Mangieri
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Antonio Colombo
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Francesco Giannini
- Interventional Cardiology Unit, Maria Cecilia Hospital, GVM Care and Research.
| |
Collapse
|
2
|
Ali Z, Sharma P, Mengesha T, Dalmar A, Ammar KA, Allaqaband SQ, O'Hair DP, Khandheria BK, Jain R, Bajwa T. Early clinical and procedural outcomes in large series of 34-mm self-expanding transcatheter aortic valve replacement. Catheter Cardiovasc Interv 2020; 96:940-946. [PMID: 31797524 DOI: 10.1002/ccd.28634] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 10/17/2019] [Accepted: 11/21/2019] [Indexed: 11/07/2022]
Abstract
OBJECTIVES We aimed to evaluate early clinical and procedural outcomes with the 34-mm Evolut R transcatheter aortic valve replacement (TAVR) prosthesis. BACKGROUND The 34-mm Evolut R (Medtronic, Minneapolis, MN) self-expanding TAVR prosthesis was designed to treat patients with larger annuli. METHODS Clinical, demographic, procedural, and echocardiographic data on consecutive patients who underwent TAVR with a 34-mm Evolut R prosthesis at our institution were collected and analyzed. RESULTS One hundred ninety-six patients underwent TAVR with this prosthesis from November 2016 to July 2018, a majority (n = 188, 96%) through transfemoral access and with conscious sedation (n = 182, 93%). Mean age, Society of Thoracic Surgery risk score, and follow-up were 82 ± 8 years, 5.4 ± 5%, and 8.2 ± 5.3 months, respectively. Mean aortic valve (AV) peak velocity was 4.0 ± 0.6 m/s, mean AV gradient was 38 ± 13 mmHg, AV area was 0.79 ± 0.23 cm2 ; calcium score was 3,503 ± 1,970 Agatston units, and perimeter was 85 ± 4.3 mm. Device implantation was successful in all but one patient. Postprocedure mean AV peak velocity, AV mean gradient, and AV area were 1.9 ± 0.4 m/s, 7 ± 3 mmHg, and 2.6 ± 0.7 cm2 , respectively. New pacemaker requirement rate was 16%, and moderate paravalvular leak was present in six patients (3%), which improved to mild in three patients at 6-month follow-up. In-hospital, 30-day, 6-month, and 12-month survival rates were 98%, 96% (hospital discharge), 96% (30-day), 89% (6-month), and 83% (12-month). CONCLUSION These data demonstrate high success and good procedural, echocardiographic, and clinical outcomes of 34-mm Evolut R in patients with large annuli.
Collapse
Affiliation(s)
- Zuber Ali
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Payal Sharma
- Department of Internal Medicine, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Tadele Mengesha
- Advocate Aurora Research, Advocate Aurora Health, Milwaukee, Wisconsin
| | - Ahmed Dalmar
- Advocate Aurora Research, Advocate Aurora Health, Milwaukee, Wisconsin
| | - Khawaja Afzal Ammar
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Suhail Q Allaqaband
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Daniel P O'Hair
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Bijoy K Khandheria
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Renuka Jain
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| | - Tanvir Bajwa
- Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin
| |
Collapse
|
3
|
Tang GHL, Reardon MJ, Kodali SK, Hermiller JB, Sorajja P, Szeto WY, Zhang A, Popma JJ. Comparison of Clinical and Echocardiographic Outcomes After Transcatheter Aortic Valve Implantation With 31-mm CoreValve Versus 34-mm Evolut R Bioprostheses from the STS/ACC TVT Registry. Am J Cardiol 2019; 124:1091-1098. [PMID: 31362879 DOI: 10.1016/j.amjcard.2019.07.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 06/26/2019] [Accepted: 07/02/2019] [Indexed: 11/18/2022]
Abstract
Transcatheter aortic valve implantation with a bioprosthetic valve of insufficient size is associated with a higher risk of aortic regurgitation (AR). The 31-mm CoreValve and the next generation 34-mm Evolut R bioprostheses were designed to address the need for larger diameter aortic annuli. This analysis examined the clinical and hemodynamic outcomes following commercial transcatheter aortic valve implantation with the 31-mm CoreValve and 34-mm Evolut R in the Society of Thoracic Surgeons/the American College of Cardiology Transcatheter Valve Therapy Registry. Patients receiving a 31-mm CoreValve or 34-mm Evolut R valve for symptomatic severe native aortic stenosis from January 2014 to September 2017 in the Transcatheter Valve Therapy Registry underwent propensity score matching using baseline demographics, clinical and frailty measures, and procedural variables. Procedural characteristics, in-hospital and 30-day clinical and echocardiographic outcomes were compared. Of 4545 patients implanted with a 31-mm CoreValve and 3036 patients with a 34-mm Evolut R valve, matching resulted in 1813 patient sets. Most patients were male (>92%), elderly (∼80 years) with the Society of Thoracic Surgeons score of 6.6%. Use of the 34-mm versus 31-mm valve resulted in shorter median procedural time (113.0 [85.0, 150.0] vs 93.0 [71.0, 126.0] min, p <0.001), higher device success (98.1% vs 93.9%, p <0.001), fewer pacemakers (16.7% vs 24.6%, p <0.001), less ≥moderate AR with the 34-mm (5.5% vs 13.7%), p <0.001) and shorter hospital stay (3.0 [2.0, 4.0] vs 4.0 [3.0, 6.0] days, p <0.001). In conclusion, this largest experience with the 34-mm Evolut R valve showed higher device success, reduced hospital stay, lower pacemaker rates and less ≥moderate AR compared with the 31-mm CoreValve bioprosthesis.
Collapse
Affiliation(s)
| | - Michael J Reardon
- Houston Methodist DeBakey Heart and Vascular Institute, Houston, Texas
| | - Susheel K Kodali
- Columbia University Medical Center - New York Presbyterian Hospital, New York, New York
| | | | - Paul Sorajja
- Valve Science Center, Minneapolis Heart Institute Foundation, Abbott-Northwestern Hospital, Minneapolis, Minnesota
| | - Wilson Y Szeto
- University of Pennsylvania Medical Center, Philadelphia, Pennsylvania
| | - Angie Zhang
- Medtronic, Department of Statistical Services, Minneapolis, Minnesota
| | - Jeffrey J Popma
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
4
|
Takagi H, Hari Y, Nakashima K, Kuno T, Ando T. Network meta-analysis of new-generation valves for transcatheter aortic valve implantation. Heart Vessels 2019; 34:1984-1992. [PMID: 31144096 DOI: 10.1007/s00380-019-01442-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 05/24/2019] [Indexed: 11/29/2022]
Abstract
To comprehensively compare and rank new-generation valves (NGVs) for transcatheter aortic valve implantation, we performed a network meta-analysis (NMA) of all eligible comparative studies. MEDLINE and EMBASE were searched through September 2018. We included all studies comparing 4 NGVs (ACURATE, Evolut R, Lotus, and SAPIEN 3) and an early generation valve (CoreValve) as the reference transcatheter heart valve (THV) each other and reporting at least one of postprocedural incidence of all-cause death, ≥ moderate aortic regurgitation (AR), and new permanent pacemaker implantation (PMI). To compare different THVs, a random-effects restricted-maximum-likelihood NMA based on a frequentist framework for indirect and mixed comparisons was used. Using surface under the cumulative ranking curve (SUCRA), the relative ranking probability of each THV was estimated and the hierarchy of competing THVs was obtained. We identified 29 eligible studies enrolling a total of 17,817 patients. In accordance with the estimated SUCRA probability, SAPIEN 3 was the best effective for a reduction in death (80.6%) and the second best for decreased ≥ moderate AR (74.4%) and PMI (74.1%) compared with the other THVs. Lotus was ranked the best for a reduction in ≥ moderate AR (94.5%;), whereas the worst for decreased PMI (1.2%) and the second worst for a reduction in mortality (38.6%). ACURATE was the best for decreased PMI (99.2%) and the second best for a reduction in mortality (77.9%). As a whole, SAPIEN 3 may be the best effective NGV among the 4 examined NGVs (ACURATE, Evolut R, Lotus, and SAPIEN 3).
Collapse
Affiliation(s)
- Hisato Takagi
- Department of Cardiovascular Surgery, Shizuoka Medical Center, 762-1 Nagasawa, Shimizu-cho, Sunto-gun, Shizuoka, 411-8611, Japan. .,Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Japan.
| | - Yosuke Hari
- Department of Cardiovascular Surgery, Shizuoka Medical Center, 762-1 Nagasawa, Shimizu-cho, Sunto-gun, Shizuoka, 411-8611, Japan.,Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Japan
| | - Kouki Nakashima
- Department of Cardiovascular Surgery, Shizuoka Medical Center, 762-1 Nagasawa, Shimizu-cho, Sunto-gun, Shizuoka, 411-8611, Japan.,Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Japan
| | - Toshiki Kuno
- Department of Medicine, Mount Sinai Beth Israel Medical Center, New York, NY, USA
| | - Tomo Ando
- Department of Cardiology, Detroit Medical Center, Detroit, MI, USA
| | | |
Collapse
|