1
|
Hascoet S, Baruteau AE, Jalal Z, Demkow M, de Winter R, Gaio G, Clerc JM, Sabiniewicz R, Eberli F, Santoro G, Dauphin C, Schubert S, Smolka G, Lutz M, Moreno R, Pan M, Gutierrez-Larraya F, Godart F, Carminati M, Ovaert C, Batteux C, Guerin P, Thambo JB, Ewert P. Safety and efficacy of the Amplatzer™ Trevisio™ intravascular delivery system: Post-approval study results. Arch Cardiovasc Dis 2023; 116:580-589. [PMID: 37951755 DOI: 10.1016/j.acvd.2023.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 10/12/2023] [Accepted: 10/13/2023] [Indexed: 11/14/2023]
Abstract
BACKGROUND The Amplatzer™ Trevisio™ Intravascular Delivery System (Trevisio DS; Abbott Laboratories, Chicago, IL, USA) facilitates the delivery of Amplatzer™ Occluders and features an ultraflexible tip, which improves assessment of occluder position before release. AIMS To assess the safety and efficacy of the Trevisio DS for transcatheter closure of patent foramen ovale and atrial septal defect. METHODS The Amplatzer™ Trevisio™ Intravascular Delivery System Post-Approval Study was a prospective, postmarket, single-arm, multicentre, observational study of the Trevisio DS. Enrolled patients were indicated for transcatheter closure of patent foramen ovale or atrial septal defect. In all procedures, the Trevisio DS was used to deliver Amplatzer™ Occluders. Technical success was defined as successful deployment and release of at least one occluder. Device- or procedure-related serious adverse events were tracked until discharge or day 7, whichever occurred earlier. RESULTS The study enrolled 144 patients with patent foramen ovale and 107 patients with atrial septal defect at 22 European sites; 53 patients with atrial septal defect (49.6%) were aged<18years. The rate of technical success was 98.4% (97.2% for atrial septal defect, 99.3% for patent foramen ovale). There was one serious adverse event (0.4%), an acute periprocedural device embolization that occurred after occluder release in a patient with atrial septal defect; the device was retrieved percutaneously. This was determined by the implanter to be unrelated to the performance of the Trevisio DS. CONCLUSIONS The Trevisio DS exhibited a high rate of technical success and an excellent safety profile during transcatheter closure of patent foramen ovale and atrial septal defect.
Collapse
Affiliation(s)
- Sebastien Hascoet
- Hôpital Marie-Lannelongue, Groupe Hospitalier Paris Saint-Joseph, Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Centre Constitutif Réseau Maladies Rares Cardiopathies Congénitales Complexes (M3C), BME Lab, 92350 Le Plessis-Robinson, France.
| | - Alban-Elouen Baruteau
- Nantes Université, CHU de Nantes, Department of Paediatric Cardiology and Paediatric Cardiac Surgery, FHU PRECICARE, 44000 Nantes, France; Nantes Université, CHU de Nantes, Inserm, CIC FEA 1413, 44000 Nantes, France; Nantes Université, CHU de Nantes, CNRS, Inserm, l'Institut du Thorax, 44000 Nantes, France
| | - Zakaria Jalal
- Department of Paediatric and Adult Congenital Cardiology, CHU de Bordeaux, 33000 Bordeaux, France; Centre Constitutif Réseau Maladies Rares Cardiopathies Congénitales Complexes (M3C), 92350 Le Plessis-Robinson, France; Electrophysiology and Heart Modelling Institute, IHU Liryc, Fondation Bordeaux Université, 33000 Bordeaux, France
| | - Marcin Demkow
- The Cardinal Stefan Wyszynski Institute of Cardiology, Alpejska 42, 04-628 Warsaw, Poland
| | - Robbert de Winter
- Amsterdam Academic Medical Centre (AMC), 1105 AZ Amsterdam, The Netherlands
| | | | | | | | | | | | | | - Stephan Schubert
- Deutsches Herzzentrum Berlin, 13353 Berlin, Germany; Herz-und Diabetes Zentrum NRW, University Clinic of Ruhr-University Bochum, 32545 Bad Oeynhausen, Germany
| | | | - Matthias Lutz
- Universitätsklinikum Schleswig-Holstein Campus Kiel, 24105 Kiel, Germany
| | - Raul Moreno
- Hospital Universitario de la Paz, 28046 Madrid, Spain
| | - Manuel Pan
- Hospital Universitario Reina Sofia, 14004 Cordoba, Spain
| | | | | | | | | | - Clement Batteux
- Hôpital Marie-Lannelongue, Groupe Hospitalier Paris Saint-Joseph, Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Centre Constitutif Réseau Maladies Rares Cardiopathies Congénitales Complexes (M3C), BME Lab, 92350 Le Plessis-Robinson, France
| | | | - Jean-Benoit Thambo
- Centre Constitutif Réseau Maladies Rares Cardiopathies Congénitales Complexes (M3C), 92350 Le Plessis-Robinson, France; Electrophysiology and Heart Modelling Institute, IHU Liryc, Fondation Bordeaux Université, 33000 Bordeaux, France
| | - Peter Ewert
- Deutsches Herzzentrum München des Freistaates Bayern, 80636 München, Germany
| |
Collapse
|
2
|
Santoro G, Pizzuto A, Cuman M, Haxhiademi D, Marchese P, Franchi E, Marrone C, Pak V, Assanta N, Cantinotti M. Transcatheter closure of "Surgical" ostium secundum atrial septal defects with GORE® Cardioform ASD Occluder. J Card Surg 2022; 37:3200-3206. [PMID: 35900295 DOI: 10.1111/jocs.16786] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/12/2022] [Accepted: 06/22/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To evaluate the GORE® Cardioform ASD Occluder (GCA)(WL Gore & Associates) device for closure of ostium secundum atrial septal defects (ASDs) with predicted indication for surgical correction. BACKGROUND Closure of large ASD in small children by transcatheter approach is still challenging. This study evaluated the results of GCA in this subset of patients in a tertiary referral center. METHODS Between January 2020 and March 2022, 97 children underwent transcatheter ASD closure at our Institution. Of them, 38 had a large defect (diameter/weight > 1.2 or diameter/body surface area > 20 mm/m2 ), predicted suitable for surgery and underwent closure with GCA. Procedure results and midterm outcome are reported. RESULTS Patients' age and weight were 5.5 ± 1.5 years and 19.7 ± 4.7 kg, respectively. Absolute and relative ASD size was 21.5 ± 3.6 mm, 1.1 ± 0.2 mm/kg, and 27.7 ± 4.6 mm/m2 , respectively, resulting in QP/QS of 2.0 ± 0.8. Three patients were sent to surgery after balloon sizing. Four of the remaining 35 patients who underwent device deployment, needed rescue or elective surgery due to device embolization (n = 1), device instability (n = 2) or new-onset tricuspid valve regurgitation (n = 1). Procedure feasibility was 88.6%. Major complications were recorded in two patients (5.7%). Minor complications were recorded in five patients (14.3%). Complete closure at discharge was 90.3% (28/31 pts) rising to 100% at the last follow-up evaluation. Wireframe fracture rate at the 6 months examination was 52%, without clinical and instrumental consequences. CONCLUSIONS Percutaneous treatment with GCA device is effective and safe in a high percentage of ASD children with predicted indications for surgical correction.
Collapse
Affiliation(s)
- Giuseppe Santoro
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Alessandra Pizzuto
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Magdalena Cuman
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Dorela Haxhiademi
- Anesthesia and Intensive Care Unit, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Pietro Marchese
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Eliana Franchi
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Chiara Marrone
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Vitali Pak
- Pediatric Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Nadia Assanta
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| | - Massimiliano Cantinotti
- Pediatric Cardiology and Cardiac Surgery, Heart Hospital "G. Pasquinucci," National Research Council-Tuscany Foundation "G. Monasterio", Massa, Italy
| |
Collapse
|