• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4612470)   Today's Articles (20)   Subscriber (49386)
For: Flores E, Patel M, Orme G, Su W. Successful implantation of a Micra leadless pacemaker via collateral femoral vein and inferior vena cava filter. Clin Case Rep 2018. [PMID: 29531727 PMCID: PMC5838272 DOI: 10.1002/ccr3.1386] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]  Open
Number Cited by Other Article(s)
1
Chau EMC, Wong RKP. Bilateral external iliac vein compression-An important consideration in implantation of leadless permanent pacemaker. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021;44:1636-1640. [PMID: 34018224 DOI: 10.1111/pace.14259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 04/21/2021] [Accepted: 05/02/2021] [Indexed: 11/28/2022]
2
Shah K, Patel S, Hanson I, Williamson B, Kutinsky I, Dixon S, Haines DE, Mehta NK. Navigating inferior vena cava filters in invasive cardiology procedures: A systematic review. J Cardiovasc Electrophysiol 2021;32:1440-1448. [PMID: 33772931 DOI: 10.1111/jce.15010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 02/25/2021] [Accepted: 03/10/2021] [Indexed: 12/29/2022]
3
Houmsse M, Karki R, Gabriels J, Reinig M, Patel D, Hussain SK, Gandhi GD, Lloyd MS, Makary MS, Okabe T, Tamirisa K, Joza J, Patel A, Afzal MR, Epstein LM, Cha Y. Implantation of leadless pacemakers via inferior vena cava filters is feasible and safe: Insights from a multicenter experience. J Cardiovasc Electrophysiol 2020;31:3277-3285. [DOI: 10.1111/jce.14776] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Revised: 09/03/2020] [Accepted: 09/10/2020] [Indexed: 12/15/2022]
4
Direct Femoral Vein Leadless Pacemaker Implantation. JACC Clin Electrophysiol 2020;5:639-640. [PMID: 31122389 DOI: 10.1016/j.jacep.2019.01.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 01/17/2019] [Indexed: 11/24/2022]
5
Matsuhashi N, Suzuki N, Goto E, Murayama Y, Hasegawa K, Horinaka S. Successful implantation of leadless pacemaker in patient with the Günther Tulip inferior vena cava filter. J Cardiol Cases 2019;19:70-73. [PMID: 31193668 DOI: 10.1016/j.jccase.2018.11.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 11/02/2018] [Accepted: 11/06/2018] [Indexed: 10/27/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA