1
|
Sakata T. Signal transduction interfaces for field-effect transistor-based biosensors. Commun Chem 2024; 7:35. [PMID: 38374200 PMCID: PMC10876964 DOI: 10.1038/s42004-024-01121-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 02/06/2024] [Indexed: 02/21/2024] Open
Abstract
Biosensors based on field-effect transistors (FETs) are suitable for use in miniaturized and cost-effective healthcare devices. Various semiconductive materials can be applied as FET channels for biosensing, including one- and two-dimensional materials. The signal transduction interface between the biosample and the channel of FETs plays a key role in translating electrochemical reactions into output signals, thereby capturing target ions or biomolecules. In this Review, distinctive signal transduction interfaces for FET biosensors are introduced, categorized as chemically synthesized, physically structured, and biologically induced interfaces. The Review highlights that these signal transduction interfaces are key in controlling biosensing parameters, such as specificity, selectivity, binding constant, limit of detection, signal-to-noise ratio, and biocompatibility.
Collapse
Affiliation(s)
- Toshiya Sakata
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.
| |
Collapse
|
2
|
Kim Y, Inoue Y, Hasegawa H, Yoshida Y, Sakata T. In Situ Electrical Monitoring of Methylated DNA Based on Its Conformational Change to G-Quadruplex Using a Solution-Gated Field-Effect Transistor. Anal Chem 2021; 93:16709-16717. [PMID: 34859677 DOI: 10.1021/acs.analchem.1c04466] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Methylated DNA is not only a diagnostic but also a prognostic biomarker for early-stage cancer. However, sodium bisulfite sequencing as a "gold standard" method for detection of methylation markers has some drawbacks such as its time-consuming and labor-intensive procedures. Therefore, simple and reliable methods are required to analyze DNA sequences with or without methylated residues. Herein, we propose a simple and direct method for detecting DNA methylation through its conformation transition to G-quadruplex using a solution-gated field-effect transistor (SG-FET) without using labeled materials. The BCL-2 gene, which is involved in the development of various human tumors, contains G-rich segments and undergoes a conformational change to G-quadruplex depending on the K+ concentration. Stacked G-quadruplex strands move close to the SG-FET sensor surface, resulting in large electrical signals based on intrinsic molecular charges. In addition, a dense hydrophilic polymer brush is grafted using surface-initiated atom transfer radical polymerization onto the SG-FET sensor surface to reduce electrical noise based on nonspecific adsorption of interfering species. In particular, control of the polymer brush thickness induces electrical signals based on DNA molecular charges in the diffusion layer, according to the Debye length limit. A platform based on the SG-FET sensor with a well-defined polymer brush is suitable for in situ monitoring of methylated DNA and realizes a point-of-care device with a high signal-to-noise ratio and without the requirement for additional processes such as bisulfite conversion and polymerase chain reaction.
Collapse
Affiliation(s)
- Yeji Kim
- Advanced Technology Research Dept., LG Japan Lab Inc., Glass Cube Shinagawa, 4-13-14 Higashi Shinagawa, Shinagawa-ku, Tokyo 140-0002, Japan
| | - Yuuki Inoue
- Advanced Technology Research Dept., LG Japan Lab Inc., Glass Cube Shinagawa, 4-13-14 Higashi Shinagawa, Shinagawa-ku, Tokyo 140-0002, Japan
| | - Hijiri Hasegawa
- Advanced Technology Research Dept., LG Japan Lab Inc., Glass Cube Shinagawa, 4-13-14 Higashi Shinagawa, Shinagawa-ku, Tokyo 140-0002, Japan
| | | | - Toshiya Sakata
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| |
Collapse
|
3
|
Sakata T. Biologically Coupled Gate Field-Effect Transistors Meet in Vitro Diagnostics. ACS OMEGA 2019; 4:11852-11862. [PMID: 31460295 PMCID: PMC6682067 DOI: 10.1021/acsomega.9b01629] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 06/26/2019] [Indexed: 05/22/2023]
Abstract
In this paper, recent works on biologically coupled gate field-effect transistor (bio-FET) sensors are introduced and compared to provide a perspective. Most biological phenomena are closely related to behaviors of ions and biomolecules. This is why biosensing devices for detecting ionic and biomolecular charges contribute to the direct analysis of biological phenomena in a label-free and enzyme-free manner. Potentiometric biosensors such as bio-FET sensors, which allow the direct detection of these charges on the basis of the field effect, meet this requirement and have been developed as simple devices for in vitro diagnostics (IVD). A variety of biological ionic behaviors generated by biomolecular recognition events and cellular activities are being targeted for clinical diagnostics as well as the study of neuroscience using the bio-FET sensors. To realize these applications, bioelectrical interfaces should be formed between the electrolyte solution and the gate electrode by modifying artificially synthesized and biomimetic membranes, resulting in the selective detection of targets based on intrinsic molecular charges. Various types of semiconducting materials, not only inorganic semiconductors but also organic semiconductors, can be selected for use in bio-FET sensors, depending on the application field. In addition, a semiconductor integrated circuit device is ideal for the massively parallel detection of multiple samples. Thus, platforms based on bio-FET sensors are suitable for use in simple and miniaturized electrical circuit systems for IVD to enable the prevention and early detection of diseases.
Collapse
|
4
|
Kajisa T, Sakata T. Molecularly Imprinted Artificial Biointerface for an Enzyme-Free Glucose Transistor. ACS APPLIED MATERIALS & INTERFACES 2018; 10:34983-34990. [PMID: 30234958 DOI: 10.1021/acsami.8b13317] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A platform based on a highly selective and sensitive detection device functionalized with a well-designed artificial biointerface is required for versatile biosensors. We develop a molecularly imprinted polymer (MIP)-coated gate field-effect transistor (FET) biosensor for low-concentration glucose detection in biological fluid samples such as tears in an enzyme-free manner. The MIP includes glucose templates (GluMIP), in which glucose binds to vinylphenylboronic acid in the copolymerized membrane, resulting in the change in the density of molecular charges of the phenylboronic acid (PBA)/glucose complex. The FET biosensor can detect small biomolecules as long as biomolecular recognition events cause intrinsic changes in the density of molecular charges. As a result, the changes in the output voltage detected using the GluMIP-based FET sensor are fitted to the Langmuir adsorption isotherm equation at various concentrations of sugars, showing the low detection limit of 3 μM and the high sensitivity of 115 mV/decade from 100 μM to 4 mM glucose. On the basis of the equation, the stability constant ( Ka) of PBA with glucose is calculated and found to markedly increase to Ka = 1192 M-1, which is higher by a factor of a few hundreds than Ka = 4.6 M-1 obtained by nonelectrical detection methods. Moreover, the GluMIP-coated gate FET sensor shows an approximately 200-fold higher selectivity for glucose than for fructose. This is because glucose binds to PBA more selectively than fructose in the templates, resulting in the generation of negative charges. The electrical properties of the MIP-coated electrode are also evaluated by measuring capacitance. Our work suggests a new strategy of designing a platform based on the MIP-coated gate FET biosensor, which is suitable for a highly selective, sensitive, enzyme-free biosensing system.
Collapse
|
5
|
Lowe BM, Sun K, Zeimpekis I, Skylaris CK, Green NG. Field-effect sensors - from pH sensing to biosensing: sensitivity enhancement using streptavidin-biotin as a model system. Analyst 2018; 142:4173-4200. [PMID: 29072718 DOI: 10.1039/c7an00455a] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Field-Effect Transistor sensors (FET-sensors) have been receiving increasing attention for biomolecular sensing over the last two decades due to their potential for ultra-high sensitivity sensing, label-free operation, cost reduction and miniaturisation. Whilst the commercial application of FET-sensors in pH sensing has been realised, their commercial application in biomolecular sensing (termed BioFETs) is hindered by poor understanding of how to optimise device design for highly reproducible operation and high sensitivity. In part, these problems stem from the highly interdisciplinary nature of the problems encountered in this field, in which knowledge of biomolecular-binding kinetics, surface chemistry, electrical double layer physics and electrical engineering is required. In this work, a quantitative analysis and critical review has been performed comparing literature FET-sensor data for pH-sensing with data for sensing of biomolecular streptavidin binding to surface-bound biotin systems. The aim is to provide the first systematic, quantitative comparison of BioFET results for a single biomolecular analyte, specifically streptavidin, which is the most commonly used model protein in biosensing experiments, and often used as an initial proof-of-concept for new biosensor designs. This novel quantitative and comparative analysis of the surface potential behaviour of a range of devices demonstrated a strong contrast between the trends observed in pH-sensing and those in biomolecule-sensing. Potential explanations are discussed in detail and surface-chemistry optimisation is shown to be a vital component in sensitivity-enhancement. Factors which can influence the response, yet which have not always been fully appreciated, are explored and practical suggestions are provided on how to improve experimental design.
Collapse
Affiliation(s)
- Benjamin M Lowe
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| | - Kai Sun
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| | - Ioannis Zeimpekis
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| | | | - Nicolas G Green
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| |
Collapse
|
6
|
Lowe BM, Skylaris CK, Green NG, Shibuta Y, Sakata T. Molecular dynamics simulation of potentiometric sensor response: the effect of biomolecules, surface morphology and surface charge. NANOSCALE 2018; 10:8650-8666. [PMID: 29700545 DOI: 10.1039/c8nr00776d] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The silica-water interface is critical to many modern technologies in chemical engineering and biosensing. One technology used commonly in biosensors, the potentiometric sensor, operates by measuring the changes in electric potential due to changes in the interfacial electric field. Predictive modelling of this response caused by surface binding of biomolecules remains highly challenging. In this work, through the most extensive molecular dynamics simulation of the silica-water interfacial potential and electric field to date, we report a novel prediction and explanation of the effects of nano-morphology on sensor response. Amorphous silica demonstrated a larger potentiometric response than an equivalent crystalline silica model due to increased sodium adsorption, in agreement with experiments showing improved sensor response with nano-texturing. We provide proof-of-concept that molecular dynamics can be used as a complementary tool for potentiometric biosensor response prediction. Effects that are conventionally neglected, such as surface morphology, water polarisation, biomolecule dynamics and finite-size effects, are explicitly modelled.
Collapse
Affiliation(s)
- B M Lowe
- Department of Materials Engineering, School of Engineering, The University of Tokyo 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | | | | | | | | |
Collapse
|
7
|
Lowe BM, Maekawa Y, Shibuta Y, Sakata T, Skylaris CK, Green NG. Dynamic behaviour of the silica-water-bio electrical double layer in the presence of a divalent electrolyte. Phys Chem Chem Phys 2017; 19:2687-2701. [DOI: 10.1039/c6cp04101a] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Molecular dynamics simulation of the electric double layer at the silica-water-bio interface in mixed electrolyte. Water orientation and charge distribution showed a significant effect on the electrostatics at the interface.
Collapse
Affiliation(s)
- B. M. Lowe
- Institute for Complex Systems Simulation and the Electronics and Computer Science Department
- University of Southampton
- UK
| | - Y. Maekawa
- Department of Materials Engineering School of Engineering
- The University of Tokyo
- Tokyo 113-8656
- Japan
| | - Y. Shibuta
- Department of Materials Engineering School of Engineering
- The University of Tokyo
- Tokyo 113-8656
- Japan
| | - T. Sakata
- Department of Materials Engineering School of Engineering
- The University of Tokyo
- Tokyo 113-8656
- Japan
| | | | - N. G. Green
- Department of Electronics and Computer Science
- Nano Research Group
- University of Southampton
- UK
| |
Collapse
|
8
|
Maekawa Y, Shibuta Y. Dewetting dynamics of nickel thin film on alpha-quartz substrate: A molecular dynamics study. Chem Phys Lett 2016. [DOI: 10.1016/j.cplett.2016.06.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
9
|
Lowe BM, Skylaris CK, Green NG. Acid-base dissociation mechanisms and energetics at the silica-water interface: An activationless process. J Colloid Interface Sci 2015; 451:231-44. [PMID: 25898118 DOI: 10.1016/j.jcis.2015.01.094] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2014] [Revised: 01/23/2015] [Accepted: 01/26/2015] [Indexed: 10/23/2022]
Abstract
HYPOTHESIS Silanol groups at the silica-water interface determine not only the surface charge, but also have an important role in the binding of ions and biomolecules. As the pH is increased above pH 2, the silica surface develops a net negative charge primarily due to deprotonation of the silanol group. An improved understanding of the energetics and mechanisms of this fundamentally important process would further understanding of the relevant dynamics. SIMULATIONS Density Functional Theory ab initio molecular dynamics and geometry optimisations were used to investigate the mechanisms of surface neutralisation and charging in the presence of OH(-) and H3O(+) respectively. This charging mechanism has received little attention in the literature. FINDINGS The protonation or deprotonation of isolated silanols in the presence of H3O(+) or OH(-), respectively, was shown to be a highly rapid, exothermic reaction with no significant activation energy. This process occurred via a concerted motion of the protons through 'water wires'. Geometry optimisations of large water clusters at the silica surface demonstrated proton transfer to the surface occurring via the rarely discussed 'proton holes' mechanism. This indicates that surface protonation is possible even when the hydronium ion is distant (at least 4 water molecules separation) from the surface.
Collapse
Affiliation(s)
- Benjamin M Lowe
- Complex Systems Simulation and the Electronics and Computer Science Department, University of Southampton, UK.
| | | | - Nicolas G Green
- Department of Electronics and Computer Science, Nano Research Group, University of Southampton, UK.
| |
Collapse
|
10
|
Maekawa Y, Shibuta Y, Sakata T. Effect of double-stranded DNA on electrical double layer structure at oxide/electrolyte interface in classical molecular dynamics simulation. Chem Phys Lett 2015. [DOI: 10.1016/j.cplett.2014.11.068] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|