Sopoušek J, Věžník J, Skládal P, Lacina K. Blocking the Nanopores in a Layer of Nonconductive Nanoparticles: Dominant Effects Therein and Challenges for Electrochemical Impedimetric Biosensing.
ACS APPLIED MATERIALS & INTERFACES 2020;
12:14620-14628. [PMID:
32134623 DOI:
10.1021/acsami.0c02650]
[Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Blockage of a nanopore by an analyte molecule has emerged as a promising concept for electrochemical biosensing. Nanoporous structures can be formed on the electrode surface simply by packing spherical nanoparticles in a dense planar arrangement. Modification of the nanoparticles with human serum albumin (HSA) and its interaction with the corresponding antibody (anti-HSA) can induce nanopore-blockage which significantly hinders permeation of the redox probe ([Fe(CN6)]4-/3-). Interfaces of different parameters were studied using Electrochemical Impedance Spectroscopy (EIS), and counterintuitively, the influence of charge of the nanoparticles and other immobilized entities played a substantial role in the measurement. Our study reveals dominant effects including the presence of mixed output signal and resolves corresponding EIS biosensing-related challenges. Consequently, blocking the nanopores was introduced as an efficient technique which enables the application of EIS-based biosensing to real-world analytical issues.
Collapse