1
|
Fan X, Walther A. 1D Colloidal chains: recent progress from formation to emergent properties and applications. Chem Soc Rev 2022; 51:4023-4074. [PMID: 35502721 DOI: 10.1039/d2cs00112h] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Integrating nanoscale building blocks of low dimensionality (0D; i.e., spheres) into higher dimensional structures endows them and their corresponding materials with emergent properties non-existent or only weakly existent in the individual building blocks. Constructing 1D chains, 2D arrays and 3D superlattices using nanoparticles and colloids therefore continues to be one of the grand goals in colloid and nanomaterial science. Amongst these higher order structures, 1D colloidal chains are of particular interest, as they possess unique anisotropic properties. In recent years, the most relevant advances in 1D colloidal chain research have been made in novel synthetic methodologies and applications. In this review, we first address a comprehensive description of the research progress concerning various synthetic strategies developed to construct 1D colloidal chains. Following this, we highlight the amplified and emergent properties of the resulting materials, originating from the assembly of the individual building blocks and their collective behavior, and discuss relevant applications in advanced materials. In the discussion of synthetic strategies, properties, and applications, particular attention will be paid to overarching concepts, fresh trends, and potential areas of future research. We believe that this comprehensive review will be a driver to guide the interdisciplinary field of 1D colloidal chains, where nanomaterial synthesis, self-assembly, physical property studies, and material applications meet, to a higher level, and open up new research opportunities at the interface of classical disciplines.
Collapse
Affiliation(s)
- Xinlong Fan
- Institute for Macromolecular Chemistry, Albert-Ludwigs-University Freiburg, Stefan-Meier-Str. 31, 79104, Freiburg, Germany.
| | - Andreas Walther
- A3BMS Lab, Department of Chemistry, University of Mainz, Duesbergweg 10-14, 55128 Mainz, Germany.
| |
Collapse
|
2
|
Mahmoudian F, Akbariqomi M, Heidari R, Ghahremani MH, Roshan N, Adabi M, Absalan M, Karimi F, Bahrami S, Fathi S, Tavoosidana G. Designing a fluorescence padlock probe-based biosensor and colorimetric assay for the detection of G12D KRAS mutation. Biomark Med 2021; 15:1741-1754. [PMID: 34784779 DOI: 10.2217/bmm-2021-0333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Aim: Cell-free DNA in the plasma is known to be a potential biomarker for noninvasive diagnosis of oncogenic mutations. The authors aimed to design an optimized padlock probe-based hyperbranched rolling circle amplification biosensor to detect the KRAS G12D mutation using fluorescence and colorimetric methods. Methods: Single-factor experiments, Plackett-Burman design and response surface methodology were applied to optimize the padlock probe-based hyperbranched rolling circle amplification reaction. Results: The maximum fluorescence intensity was achieved at a padlock probe concentration of 1.5 pM and target concentration of 9 pM at 38°C ligation temperature. The proposed biosensor has a low detection limit of 60 fM of target DNA and a linear response in the concentration range of 60 fM to 0.2 pM. Conclusion: The results indicated the power of these assays to detect KRAS point mutations in liquid state reactions.
Collapse
Affiliation(s)
- Fatemeh Mahmoudian
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mostafa Akbariqomi
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Reza Heidari
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad H Ghahremani
- Department of Toxicology and Pharmacology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Nader Roshan
- Department of Internal Medicine, Division of Gastroenterology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahdi Adabi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Moloud Absalan
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Fatemeh Karimi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Samira Bahrami
- Department of Biotechnology, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Samaneh Fathi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Gholamreza Tavoosidana
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
3
|
Wang ZY, Li P, Cui L, Qiu JG, Jiang B, Zhang CY. Integration of nanomaterials with nucleic acid amplification approaches for biosensing. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115959] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
4
|
Nguyen TTV, Xie X, Xu J, Wu Y, Hong M, Liu X. Plasmonic bimetallic nanodisk arrays for DNA conformation sensing. NANOSCALE 2019; 11:19291-19296. [PMID: 31560008 DOI: 10.1039/c9nr06101k] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The integration of large-scale 2D bimetallic Ag/Au nanodisk arrays with gold nanoparticles is developed for sensing DNA conformation with the assistance of 3D finite-difference time-domain simulation. The optimized system comprising Ag/Au nanodisk arrays and gold nanoparticles offers a more than 6-fold enhancement in surface plasmon resonance shift, enabling the feasibility for sensitive DNA detection with a detection limit down to 100 femtomolar. Importantly, owing to the distance-dependent nature of the surface plasmon signal, sensitive differentiation of DNA conformations can be achieved with a conventional optical measurement. This platform could provide new exciting capabilities for a reliable, reproducible, and label-free assay analysis for investigating the conformations of DNA and other biological molecules.
Collapse
Affiliation(s)
- Thanh Thi Van Nguyen
- Advanced Materials for Micro- and Nano-Systems Programme, Singapore-MIT Alliance, 117576, Singapore
| | - Xiaoji Xie
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, 117543, Singapore.
| | - Jiahui Xu
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, 117543, Singapore.
| | - Yiming Wu
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, 117543, Singapore.
| | - Minghui Hong
- Department of Electrical and Computer Engineering, National University of Singapore, 117576, Singapore
| | - Xiaogang Liu
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, 117543, Singapore. and The N.1 Institute for Health, National University of Singapore, 28 Medical Dr. #05-COR, 117456, Singapore and Joint School of National University of Singapore and Tianjin University, International Campus of Tianjin University, Fuzhou, 350207, P. R. China
| |
Collapse
|
5
|
Yuan X, Xiao F, Zhao H, Huang Y, Shao C, Weizmann Y, Tian L. High-Yield Method To Fabricate and Functionalize DNA Nanoparticles from the Products of Rolling Circle Amplification. ACS APPLIED BIO MATERIALS 2018; 1:511-519. [DOI: 10.1021/acsabm.8b00238] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Xuexia Yuan
- Department of Materials Science and Engineering, Southern University of Science and Technology, 1088 Xueyuan Boulevard, Nanshan District, Shenzhen, Guangdong 518055, People’s Republic of China
| | - Fan Xiao
- Department of Materials Science and Engineering, Southern University of Science and Technology, 1088 Xueyuan Boulevard, Nanshan District, Shenzhen, Guangdong 518055, People’s Republic of China
| | - Haoran Zhao
- Department of Materials Science and Engineering, Southern University of Science and Technology, 1088 Xueyuan Boulevard, Nanshan District, Shenzhen, Guangdong 518055, People’s Republic of China
| | - Yishun Huang
- Department of Materials Science and Engineering, Southern University of Science and Technology, 1088 Xueyuan Boulevard, Nanshan District, Shenzhen, Guangdong 518055, People’s Republic of China
| | - Chen Shao
- Department of Materials Science and Engineering, Southern University of Science and Technology, 1088 Xueyuan Boulevard, Nanshan District, Shenzhen, Guangdong 518055, People’s Republic of China
| | - Yossi Weizmann
- Department of Chemistry, The University of Chicago, 929 East 57th Street, Chicago, Illinois 60637, United States
| | - Leilei Tian
- Department of Materials Science and Engineering, Southern University of Science and Technology, 1088 Xueyuan Boulevard, Nanshan District, Shenzhen, Guangdong 518055, People’s Republic of China
| |
Collapse
|
6
|
Jeong J, Kim H, Lee DJ, Jung BJ, Lee JB. RCA-Based Biosensor for Electrical and Colorimetric Detection of Pathogen DNA. NANOSCALE RESEARCH LETTERS 2016; 11:242. [PMID: 27142880 PMCID: PMC4854857 DOI: 10.1186/s11671-016-1440-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Accepted: 04/15/2016] [Indexed: 06/05/2023]
Abstract
For the diagnosis and prevention of diseases, a range of strategies for the detection of pathogens have been developed. In this study, we synthesized the rolling circle amplification (RCA)-based biosensor that enables detection of pathogen DNA in two analytical modes. Only in the presence of the target DNA, the template DNA can be continuously polymerized by simply carrying out RCA, which gives rise to a change of surface structure of Au electrodes and the gap between the electrodes. Electrical signal was generated after introducing hydrogen tetrachloroaurate (HAuCl4) to the DNA-coated biosensor for the improvement of the conductivity of DNA, which indicates that the presence of the pathogen DNA can be detected in an electrical approach. Furthermore, the existence of the target DNA was readily detected by the naked eyes through change in colors of the electrodes from bright yellow to orange-red after RCA reaction. The RCA-based biosensor offers a new platform for monitoring of pathogenic DNA with two different detection modes in one system.
Collapse
Affiliation(s)
- Jaepil Jeong
- Department of Chemical Engineering, University of Seoul, Seoul, 130-743, South Korea
| | - Hyejin Kim
- Department of Chemical Engineering, University of Seoul, Seoul, 130-743, South Korea
| | - Dong Jun Lee
- Department of Materials Science and Engineering, University of Seoul, Seoul, 130-743, South Korea
| | - Byung Jun Jung
- Department of Materials Science and Engineering, University of Seoul, Seoul, 130-743, South Korea
| | - Jong Bum Lee
- Department of Chemical Engineering, University of Seoul, Seoul, 130-743, South Korea.
| |
Collapse
|
7
|
Jiang HX, Liang ZZ, Ma YH, Kong DM, Hong ZY. G-quadruplex fluorescent probe-mediated real-time rolling circle amplification strategy for highly sensitive microRNA detection. Anal Chim Acta 2016; 943:114-122. [PMID: 27769370 DOI: 10.1016/j.aca.2016.09.019] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 09/13/2016] [Accepted: 09/15/2016] [Indexed: 11/24/2022]
Abstract
Real-time PCR has revolutionized PCR from qualitative to quantitative. As an isothermal DNA amplification technique, rolling circular amplification (RCA) has been demonstrated to be a versatile tool in many fields. Development of a simple, highly sensitive, and specific strategy for real-time monitoring of RCA will increase its usefulness in many fields. The strategy reported here utilized the specific fluorescence response of thioflavin T (ThT) to G-quadruplexes formed by RCA products. Such a real-time monitoring strategy works well in both traditional RCA with linear amplification efficiency and modified RCA proceeded in an exponential manner, and can be readily performed in commercially available real-time PCR instruments, thereby achieving high-throughput detection and making the proposed technique more suitable for biosensing applications. As examples, real-time RCA-based sensing platforms were designed and successfully used for quantitation of microRNA over broad linear ranges (8 orders of magnitude) with a detection limit of 4 aM (or 0.12 zmol). The feasibility of microRNA analysis in human lung cancer cells was also demonstrated. This work provides a new method for real-time monitoring of RCA by using unique nucleic acid secondary structures and their specific fluorescent probes. It has the potential to be extended to other isothermal single-stranded DNA amplification techniques.
Collapse
Affiliation(s)
- Hong-Xin Jiang
- State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, 300071, PR China; Collaborative Innovation Centre of Chemical Science and Engineering (Tianjin), Tianjin, 300071, PR China; Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Centre for Analytical Sciences, Nankai University, Tianjin, 300071, PR China
| | - Zhen-Zhen Liang
- State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, 300071, PR China; College of Life Science, Nankai University, Tianjin, 300071, PR China
| | - Yan-Hong Ma
- State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, 300071, PR China; College of Life Science, Nankai University, Tianjin, 300071, PR China
| | - De-Ming Kong
- State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, 300071, PR China; Collaborative Innovation Centre of Chemical Science and Engineering (Tianjin), Tianjin, 300071, PR China; Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Centre for Analytical Sciences, Nankai University, Tianjin, 300071, PR China.
| | - Zhang-Yong Hong
- State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, 300071, PR China; College of Life Science, Nankai University, Tianjin, 300071, PR China.
| |
Collapse
|
8
|
Akiyama Y, Shikagawa H, Kanayama N, Takarada T, Maeda M. Modulation of Interparticle Distance in Discrete Gold Nanoparticle Dimers and Trimers by DNA Single-Base Pairing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2015; 11:3153-3161. [PMID: 25739374 DOI: 10.1002/smll.201500045] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 02/06/2015] [Indexed: 06/04/2023]
Abstract
Self-assembled structures of metallic nanoparticles with dynamically changeable interparticle distance hold promise for the regulation of collective physical properties. This paper describes gold nanoparticle dimers and trimers that exhibit spontaneous and reversible changes in interparticle distance. To exploit this property, a gold nanoparticle is modified with precisely one long DNA strand and approximately five short DNA strands. The long DNA serves to align the nanoparticles on a template DNA via hybridization, while the short DNAs function to induce the interparticle distance changes. The obtained dimer and trimer are characterized with gel electrophoresis, dynamic light scattering measurements, and transmission electron microscopy (TEM). When the complementary short DNA is added to form the fully matched duplexes on the particle surface in the presence of MgCl2 , spontaneous reduction of the interparticle distance is observed with TEM and cryo-electron microscopy. By contrast, when the terminal-mismatched DNA is added, no structural change occurs under the same conditions. Therefore, the single base pairing/unpairing at the outermost surface of the nanoparticle impacts the interparticle distance. This unique feature could be applied to the regulation of structures and properties of various DNA-functionalized nanoparticle assemblies.
Collapse
Affiliation(s)
- Yoshitsugu Akiyama
- Bioengineering Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan
| | - Hiroto Shikagawa
- Bioengineering Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan
| | - Naoki Kanayama
- Bioengineering Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan
| | - Tohru Takarada
- Bioengineering Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan
| | - Mizuo Maeda
- Bioengineering Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama, 351-0198, Japan
| |
Collapse
|
9
|
Zhang ZM, Meng YF, Zhu ML, Wang ZF, Jiang Y. Threading different metal nanomaterials on natural PhiX174 DNA to assemble a necklace. RSC Adv 2014. [DOI: 10.1039/c4ra06722c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
10
|
Ali MM, Li F, Zhang Z, Zhang K, Kang DK, Ankrum JA, Le XC, Zhao W. Rolling circle amplification: a versatile tool for chemical biology, materials science and medicine. Chem Soc Rev 2014; 43:3324-41. [DOI: 10.1039/c3cs60439j] [Citation(s) in RCA: 650] [Impact Index Per Article: 65.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
11
|
Valentini P, Pompa PP. Gold nanoparticles for naked-eye DNA detection: smart designs for sensitive assays. RSC Adv 2013. [DOI: 10.1039/c3ra43729a] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
|
12
|
Xu W, Xie X, Li D, Yang Z, Li T, Liu X. Ultrasensitive colorimetric DNA detection using a combination of rolling circle amplification and nicking endonuclease-assisted nanoparticle amplification (NEANA). SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2012; 8:1846-50. [PMID: 22461378 DOI: 10.1002/smll.201200263] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2012] [Indexed: 05/18/2023]
Abstract
A combination of rolling circle amplification and nicking endonuclease-assisted nanoparticle amplification (NEANA) is used for the rapid, colorimetric detection of DNA. The integration of rolling circle amplification into the NEANA approach allows for detection of oligonucleotides with arbitrary sequences at ultralow concentrations.
Collapse
Affiliation(s)
- Wei Xu
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543
| | | | | | | | | | | |
Collapse
|