Otomo K, Suyama K, Okamura H, Noda T, Satomi K, Shimizu W, Kurita T, Aihara N, Kamakura S. Implications of 2:1 atrioventricular block during typical atrioventricular nodal reentrant tachycardia.
J Interv Card Electrophysiol 2007;
19:109-19. [PMID:
17668303 DOI:
10.1007/s10840-007-9147-4]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2007] [Accepted: 06/26/2007] [Indexed: 12/01/2022]
Abstract
OBJECTIVE
The effects of 2:1 AV block (AVB) on AV nodal reentrant tachycardia (AVNRT) remain to be elucidated. This study was performed to localize the site of 2:1 AVB and elucidate the effects of 2:1 AVB on typical AVNRT.
METHODS
The His bundle (HB) electrograms during typical AVNRT with 2:1 AV block were reviewed in 24 patients. It was hypothesized that if 2:1 AVB at the HB or below changed tachycardia cycle length (TCL), the lower turnaround point of the reentrant circuit (RC) might be located within the HB and parts of the HB might be involved in the RC.
RESULTS
A HB potential was absent in blocked beats during 2:1 AVB in four patients (supra-Hisian block), and the maximal amplitude of the HB potential in blocked beats was the same as that in conducted beats in four patients (infra-Hisian block), and was significantly smaller than that in conducted beats (0.1 +/- 0.1 versus 0.5 +/- 0.2 mV, P < 0.05) in 16 patients (intra-Hisian block). Eight patients (33%) with intra-Hisian block had a nearly identical prolongation of the H-A and A-A intervals in blocked beats (12 +/- 3 and 13 +/- 2 ms, respectively) with unchanged A-H intervals, while the remaining 16 patients (67%) exhibited invariable A-A and/or H-A intervals.
CONCLUSION
The site of 2:1 AVB during typical AVNRT was estimated to be at the HB or below in 83% of the cases. Two-to-one intra-Hisian block transiently prolonged TCL, possibly indicating involvement of the proximal HB in the RC in one-third of typical the AVNRT cases with 2:1 AVB.
Collapse