1
|
Ganipineni LP, Ucakar B, Joudiou N, Bianco J, Danhier P, Zhao M, Bastiancich C, Gallez B, Danhier F, Préat V. Magnetic targeting of paclitaxel-loaded poly(lactic- co-glycolic acid)-based nanoparticles for the treatment of glioblastoma. Int J Nanomedicine 2018; 13:4509-4521. [PMID: 30127603 PMCID: PMC6092128 DOI: 10.2147/ijn.s165184] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Introduction Glioblastoma (GBM) therapy is highly challenging, as the tumors are very aggressive due to infiltration into the surrounding normal brain tissue. Even a combination of the available therapeutic regimens may not debulk the tumor completely. GBM tumors are also known for recurrence, resulting in survival rates averaging <18 months. In addition, systemic chemotherapy for GBM has been challenged for its minimal desired therapeutic effects and unwanted side effects. Purpose We hypothesized that paclitaxel (PTX) and superparamagnetic iron oxide (SPIO)-loaded PEGylated poly(lactic-co-glycolic acid) (PLGA)-based nanoparticles (NPs; PTX/SPIO-NPs) can serve as an effective nanocarrier system for magnetic targeting purposes, and we aimed to demonstrate the therapeutic efficacy of this system in an orthotopic murine GBM model. Materials and methods PTX/SPIO-NPs were prepared by emulsion–diffusion–evaporation method and characterized for physicochemical properties. In vitro cellular uptake of PTX/SPIO-NPs was evaluated by fluorescence microscopy and Prussian blue staining. Orthotopic U87MG tumor model was used to evaluate blood–brain barrier disruption using T1 contrast agent, ex vivo biodistribution, in vivo toxicity and in vivo antitumor efficacy of PTX/SPIO-NPs. Results PTX/SPIO-NPs were in the size of 250 nm with negative zeta potential. Qualitative cellular uptake studies showed that the internalization of NPs was concentration dependent. Through magnetic resonance imaging, we observed that the blood–brain barrier was disrupted in the GBM area. An ex vivo biodistribution study showed enhanced accumulation of NPs in the brain of GBM-bearing mice with magnetic targeting. Short-term in vivo safety evaluation showed that the NPs did not induce any systemic toxicity compared with Taxol® (PTX). When tested for in vivo efficacy, the magnetic targeting treatment significantly prolonged the median survival time compared with the passive targeting and control treatments. Conclusion Overall, PTX/SPIO-NPs with magnetic targeting could be considered as an effective anticancer targeting strategy for GBM chemotherapy.
Collapse
Affiliation(s)
- Lakshmi Pallavi Ganipineni
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| | - Bernard Ucakar
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| | - Nicolas Joudiou
- Université catholique de Louvain, Louvain Drug Research Institute, NEST Nuclear and Electron Spin Technologies Platform, Brussels, Belgium
| | - John Bianco
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| | - Pierre Danhier
- Université catholique de Louvain, Louvain Drug Research Institute, NEST Nuclear and Electron Spin Technologies Platform, Brussels, Belgium
| | - Mengnan Zhao
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| | - Chiara Bastiancich
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| | - Bernard Gallez
- Université catholique de Louvain, Louvain Drug Research Institute, NEST Nuclear and Electron Spin Technologies Platform, Brussels, Belgium
| | - Fabienne Danhier
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| | - Véronique Préat
- Université catholique de Louvain, Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Brussels, Belgium,
| |
Collapse
|
2
|
Contribution of macrophages in the contrast loss in iron oxide-based MRI cancer cell tracking studies. Oncotarget 2018; 8:38876-38885. [PMID: 28467814 PMCID: PMC5503579 DOI: 10.18632/oncotarget.17103] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Accepted: 03/29/2017] [Indexed: 12/26/2022] Open
Abstract
Magnetic resonance imaging (MRI) cell tracking of cancer cells labeled with superparamagnetic iron oxides (SPIO) allows visualizing metastatic cells in preclinical models. However, previous works showed that the signal void induced by SPIO on T2(*)-weighted images decreased over time. Here, we aim at characterizing the fate of iron oxide nanoparticles used in cell tracking studies and the role of macrophages in SPIO metabolism. In vivo MRI cell tracking of SPIO positive 4T1 breast cancer cells revealed a quick loss of T2* contrast after injection. We next took advantage of electron paramagnetic resonance (EPR) spectroscopy and inductively coupled plasma mass spectroscopy (ICP-MS) for characterizing the evolution of superparamagnetic and non-superparamagnetic iron pools in 4T1 breast cancer cells and J774 macrophages after SPIO labeling. These in vitro experiments and histology studies performed on 4T1 tumors highlighted the quick degradation of iron oxides by macrophages in SPIO-based cell tracking experiments. In conclusion, the release of SPIO by dying cancer cells and the subsequent uptake of iron oxides by tumor macrophages are limiting factors in MRI cell tracking experiments that plead for the use of (MR) reporter-gene based imaging methods for the long-term tracking of metastatic cells.
Collapse
|
3
|
Jiang J, Tian S, Wang K, Wang Y, Zang S, Yu A, Zhang Z. Electron spin resonance spectroscopy for immunoassay using iron oxide nanoparticles as probe. Anal Bioanal Chem 2017; 410:1817-1824. [PMID: 29279988 DOI: 10.1007/s00216-017-0837-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 12/09/2017] [Accepted: 12/15/2017] [Indexed: 11/29/2022]
Abstract
With the help of iron oxide nanoparticles, electron spin resonance spectroscopy (ESR) was applied to immunoassay. Iron oxide nanoparticles were used as the ESR probe in order to achieve an amplification of the signal resulting from the large amount of Fe3+ ion enclosed in each nanoparticle. Rabbit IgG was used as antigen to test this method. Polyclonal antibody of rabbit IgG was used as antibody to detect the antigen. Iron oxide nanoparticle with a diameter of either 10 or 30 nm was labeled to the antibody, and Fe3+ in the nanoparticle was probed for ESR signal. The sepharose beads were used as solid phase to which rabbit IgG was conjugated. The nanoparticle-labeled antibody was first added in the sample containing antigen, and the antigen-conjugated sepharose beads were then added into the sample. The nanoparticle-labeled antibody bound to the antigen on sepharose beads was separated from the sample by centrifugation and measured. We found that the detection ranges of the antigen obtained with nanoparticles of different sizes were different because the amount of antibody on nanoparticles of 10 nm was about one order of magnitude higher than that on nanoparticles of 30 nm. When 10 nm nanoparticle was used as probe, the upper limit of detection was 40.00 μg mL-1, and the analytical sensitivity was 1.81 μg mL-1. When 30 nm nanoparticle was used, the upper limit of detection was 3.00 μg mL-1, and the sensitivity was 0.014 and 0.13 μg mL-1 depending on the ratio of nanoparticle to antibody. Graphical abstract Schematic diagram of procedure and ESR spectra.
Collapse
Affiliation(s)
- Jia Jiang
- College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, Jilin, 130012, China
| | - Sizhu Tian
- College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, Jilin, 130012, China
| | - Kun Wang
- College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, Jilin, 130012, China
| | - Yang Wang
- Department of Materials Science and Engineering, Jilin Institute of Chemical Technology, Jilin, Jilin, 132022, China
| | - Shuang Zang
- College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, Jilin, 130012, China
| | - Aimin Yu
- College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, Jilin, 130012, China
| | - Ziwei Zhang
- College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, Jilin, 130012, China.
| |
Collapse
|
4
|
Abstract
Iron oxide nanoparticles are of interest in a wide range of biomedical applications due to their response to applied magnetic fields and their unique magnetic properties. Magnetization measurements in constant and time-varying magnetic field are often carried out to quantify key properties of iron oxide nanoparticles. This chapter describes the importance of thorough magnetic characterization of iron oxide nanoparticles intended for use in biomedical applications. A basic introduction to relevant magnetic properties of iron oxide nanoparticles is given, followed by protocols and conditions used for measurement of magnetic properties, along with examples of data obtained from each measurement, and methods of data analysis.
Collapse
|
5
|
Gallez B. Contribution of Harold M. Swartz to In Vivo EPR and EPR Dosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:16-37. [PMID: 27421469 DOI: 10.1093/rpd/ncw157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In 2015, we are celebrating half a century of research in the application of Electron Paramagnetic Resonance (EPR) as a biodosimetry tool to evaluate the dose received by irradiated people. During the EPR Biodose 2015 meeting, a special session was organized to acknowledge the pioneering contribution of Harold M. (Hal) Swartz in the field. The article summarizes his main contribution in physiology and medicine. Four emerging themes have been pursued continuously along his career since its beginning: (1) radiation biology; (2) oxygen and oxidation; (3) measuring physiology in vivo; and (4) application of these measurements in clinical medicine. The common feature among all these different subjects has been the use of magnetic resonance techniques, especially EPR. In this article, you will find an impressionist portrait of Hal Swartz with the description of the 'making of' this pioneer, a time-line perspective on his career with the creation of three National Institutes of Health-funded EPR centers, a topic-oriented perspective on his career with a description of his major contributions to Science, his role as a mentor and his influence on his academic children, his active role as founder of scientific societies and organizer of scientific meetings, and the well-deserved international recognition received so far.
Collapse
Affiliation(s)
- Bernard Gallez
- Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Avenue Mounier 73.08, B-1200, Brussels, Belgium
| |
Collapse
|
6
|
Edge D, Shortt CM, Gobbo OL, Teughels S, Prina-Mello A, Volkov Y, MacEneaney P, Radomski MW, Markos F. Pharmacokinetics and bio-distribution of novel super paramagnetic iron oxide nanoparticles (SPIONs) in the anaesthetized pig. Clin Exp Pharmacol Physiol 2016; 43:319-26. [PMID: 26707795 DOI: 10.1111/1440-1681.12533] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Revised: 12/17/2015] [Accepted: 12/18/2015] [Indexed: 11/29/2022]
Abstract
Manufactured nanomaterials have a variety of medical applications, including diagnosis and targeted treatment of cancer. A series of experiments were conducted to determine the pharmacokinetic, biodistribution and biocompatibility of two novel magnetic nanoparticles (MNPs) in the anaesthetized pig. Dimercaptosuccinic acid (DMSA) coated superparamagnetic iron oxide nanoparticles (MF66-labelled 12 nm, core nominal diameter and OD15 15 nm); at 0.5, or 2.0 mg/kg) were injected intravenously. Particles induced a dose-dependent decrease in blood pressure following administration which recovered to control levels several minutes after injection. Blood samples were collected for a 5-h period and stored for determination of particle concentration using particle electron paramagnetic resonance (pEPR). Organs were harvested post-mortem for magnetic resonance imaging (MRI at 1.5 T field strength) and histology. OD15 (2.0 mg/kg) MNP had a plasma half-life of approximately 15 min. Both doses of the MF66 (0.5 and 2.0 mg/kg) MNP were below detection limits. MNP accumulation was observed primarily in the liver and spleen with MRI scans which was confirmed by histology. MRI also showed that both MNPs were present in the lungs. The results show that further modifications may be required to improve the biocompatibility of these particles for use as diagnostic and therapeutic agents.
Collapse
Affiliation(s)
- Deirdre Edge
- Department of Physiology, School of Medicine, Trinity Biomedical Sciences Institute, Trinity College Dublin, Ireland
| | | | - Oliviero L Gobbo
- School of Pharmacy and Pharmaceutical Sciences and Trinity Biomedical Sciences Institute, Dublin, Ireland
| | | | - Adriele Prina-Mello
- School of Medicine, Trinity College Dublin, Dublin, Ireland.,CRANN, Trinity College Dublin, Dublin, Ireland
| | - Yuri Volkov
- School of Medicine, Trinity College Dublin, Dublin, Ireland.,CRANN, Trinity College Dublin, Dublin, Ireland
| | | | - Marek W Radomski
- School of Pharmacy and Pharmaceutical Sciences and Trinity Biomedical Sciences Institute, Dublin, Ireland
| | - Farouk Markos
- Department of Physiology, University College Cork, Cork, Ireland
| |
Collapse
|
7
|
Korchinski DJ, Taha M, Yang R, Nathoo N, Dunn JF. Iron Oxide as an MRI Contrast Agent for Cell Tracking. MAGNETIC RESONANCE INSIGHTS 2015; 8:15-29. [PMID: 26483609 PMCID: PMC4597836 DOI: 10.4137/mri.s23557] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Revised: 08/17/2015] [Accepted: 08/19/2015] [Indexed: 01/07/2023]
Abstract
Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation.
Collapse
Affiliation(s)
- Daniel J. Korchinski
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.,Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - May Taha
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Runze Yang
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.,Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Nabeela Nathoo
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.,Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Jeff F. Dunn
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.,Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.,Experimental Imaging Centre, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.,CORRESPONDENCE:
| |
Collapse
|
8
|
Gobbo OL, Wetterling F, Vaes P, Teughels S, Markos F, Edge D, Shortt CM, Crosbie-Staunton K, Radomski MW, Volkov Y, Prina-Mello A. Biodistribution and pharmacokinetic studies of SPION using particle electron paramagnetic resonance, MRI and ICP-MS. Nanomedicine (Lond) 2015; 10:1751-60. [DOI: 10.2217/nnm.15.22] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Aim: Superparamagnetic iron oxide nanoparticles (SPIONs) may play an important role in nanomedicine by serving as drug carriers and imaging agents. In this study, we present the biodistribution and pharmacokinetic properties of SPIONs using a new detection method, particle electron paramagnetic resonance (pEPR). Materials & methods: The pEPR technique is based on a low-field and low-frequency electron paramagnetic resonance. pEPR was compared with inductively coupled plasma mass spectrometry and MRI, in in vitro and in vivo. Results: The pEPR, inductively coupled plasma mass spectrometry and MRI results showed a good correlation between the techniques. Conclusion: The results indicate that pEPR can be used to detect SPIONs in both preclinical and clinical studies.
Collapse
Affiliation(s)
- Oliviero L Gobbo
- School of Pharmacy & Pharmaceutical Sciences, Dublin, Ireland
- Institute of Neuroscience, Trinity College Dublin, Dublin, Ireland
| | | | | | | | - Farouk Markos
- Department of Physiology, University College Cork, Cork, Ireland
| | - Deirdre Edge
- Department of Physiology, University College Cork, Cork, Ireland
| | | | | | | | - Yuri Volkov
- School of Medicine, Dublin, Ireland
- CRANN, Trinity College Dublin, Dublin, Ireland
| | - Adriele Prina-Mello
- School of Medicine, Dublin, Ireland
- CRANN, Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
9
|
Danhier P, Magat J, Levêque P, De Preter G, Porporato PE, Bouzin C, Jordan BF, Demeur G, Haufroid V, Feron O, Sonveaux P, Gallez B. In vivo visualization and ex vivo quantification of murine breast cancer cells in the mouse brain using MRI cell tracking and electron paramagnetic resonance. NMR IN BIOMEDICINE 2015; 28:367-375. [PMID: 25611487 DOI: 10.1002/nbm.3259] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 11/10/2014] [Accepted: 12/19/2014] [Indexed: 06/04/2023]
Abstract
Cell tracking could be useful to elucidate fundamental processes of cancer biology such as metastasis. The aim of this study was to visualize, using MRI, and to quantify, using electron paramagnetic resonance (EPR), the entrapment of murine breast cancer cells labeled with superparamagnetic iron oxide particles (SPIOs) in the mouse brain after intracardiac injection. For this purpose, luciferase-expressing murine 4 T1-luc breast cancer cells were labeled with fluorescent Molday ION Rhodamine B SPIOs. Following intracardiac injection, SPIO-labeled 4 T1-luc cells were imaged using multiple gradient-echo sequences. Ex vivo iron oxide quantification in the mouse brain was performed using EPR (9 GHz). The long-term fate of 4 T1-luc cells after injection was characterized using bioluminescence imaging (BLI), brain MRI and immunofluorescence. We observed hypointense spots due to SPIO-labeled cells in the mouse brain 4 h after injection on T2 *-weighted images. Histology studies showed that SPIO-labeled cancer cells were localized within blood vessels shortly after delivery. Ex vivo quantification of SPIOs showed that less than 1% of the injected cells were taken up by the mouse brain after injection. MRI experiments did not reveal the development of macrometastases in the mouse brain several days after injection, but immunofluorescence studies demonstrated that these cells found in the brain established micrometastases. Concerning the metastatic patterns of 4 T1-luc cells, an EPR biodistribution study demonstrated that SPIO-labeled 4 T1-luc cells were also entrapped in the lungs of mice after intracardiac injection. BLI performed 6 days after injection of 4 T1-luc cells showed that this cell line formed macrometastases in the lungs and in the bones. Conclusively, EPR and MRI were found to be complementary for cell tracking applications. MRI cell tracking at 11.7 T allowed sensitive detection of isolated SPIO-labeled cells in the mouse brain, whereas EPR allowed the assessment of the number of SPIO-labeled cells in organs shortly after injection.
Collapse
Affiliation(s)
- Pierre Danhier
- Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Université catholique de Louvain, Brussels, Belgium
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Danhier P, Gallez B. Electron paramagnetic resonance: a powerful tool to support magnetic resonance imaging research. CONTRAST MEDIA & MOLECULAR IMAGING 2014; 10:266-81. [PMID: 25362845 DOI: 10.1002/cmmi.1630] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Accepted: 09/18/2014] [Indexed: 12/31/2022]
Abstract
The purpose of this paper is to describe some of the areas where electron paramagnetic resonance (EPR) has provided unique information to MRI developments. The field of application mainly encompasses the EPR characterization of MRI paramagnetic contrast agents (gadolinium and manganese chelates, nitroxides) and superparamagnetic agents (iron oxide particles). The combined use of MRI and EPR has also been used to qualify or disqualify sources of contrast in MRI. Illustrative examples are presented with attempts to qualify oxygen sensitive contrast (i.e. T1 - and T2 *-based methods), redox status or melanin content in tissues. Other areas are likely to benefit from the combined EPR/MRI approach, namely cell tracking studies. Finally, the combination of EPR and MRI studies on the same models provides invaluable data regarding tissue oxygenation, hemodynamics and energetics. Our description will be illustrative rather than exhaustive to give to the readers a flavour of 'what EPR can do for MRI'.
Collapse
Affiliation(s)
- Pierre Danhier
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| |
Collapse
|
11
|
Comparison of active, passive and magnetic targeting to tumors of multifunctional paclitaxel/SPIO-loaded nanoparticles for tumor imaging and therapy. J Control Release 2014; 194:82-91. [DOI: 10.1016/j.jconrel.2014.07.059] [Citation(s) in RCA: 164] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Revised: 07/28/2014] [Accepted: 07/30/2014] [Indexed: 01/22/2023]
|
12
|
Danhier P, De Preter G, Magat J, Godechal Q, Porporato PE, Jordan BF, Feron O, Sonveaux P, Gallez B. Multimodal cell tracking of a spontaneous metastasis model: comparison between MRI, electron paramagnetic resonance and bioluminescence. CONTRAST MEDIA & MOLECULAR IMAGING 2014; 9:143-53. [PMID: 24523059 DOI: 10.1002/cmmi.1553] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Revised: 05/03/2013] [Accepted: 06/03/2013] [Indexed: 12/22/2022]
Abstract
MRI cell tracking is a promising technique for tracking various cell types in living animals. Usually, cells are incubated with iron oxides so that the particles are taken up before the cells are injected in vivo. In the present study, we aimed to monitor migration of luciferase-expressing mouse renal cancer cells (RENCA-luc) after intrarenal or intrasplenic injection. These cells were labelled using Molday Ion Rhodamine B (MIRB) fluorescent superparamagnetic iron oxide particles. Their fate after injection was first assessed using ex vivo X-band electron paramagnetic resonance (EPR) spectroscopy. This biodistribution study showed that RENCA-luc cells quickly colonized the lungs and the liver after intrarenal and intrasplenic injection, respectively. Bioluminescence imaging (BLI) studies confirmed that this cell line preferentially metastasized to these organs. Early tracking of labelled RENCA-luc cells in the liver using high-field MRI (11.7 T) was not feasible because of a lack of sensitivity. MRI of MIRB-labelled RENCA-luc cells after injection in the left kidney was then performed. T2 - and T2 *-weighted images showed that the labelled cells induced hypointense signals at the injection site. Nevertheless, the hypointense regions tended to disappear after several days, mainly owing to dilution of the MIRB iron oxides with cell proliferation. In conclusion, EPR is well adapted to ex vivo analysis of tissues after cell tracking experiments and allows short-term monitoring of metastasizing cells. MRI is a suitable tool for checking labelled cells at their injection site, but dilution of the iron oxides owing to cell division remains a major limitation. BLI remains the most suitable technique for long-term monitoring of metastatic cells.
Collapse
Affiliation(s)
- Pierre Danhier
- Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Université catholique de Louvain, Brussels, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Schleich N, Sibret P, Danhier P, Ucakar B, Laurent S, Muller R, Jérôme C, Gallez B, Préat V, Danhier F. Dual anticancer drug/superparamagnetic iron oxide-loaded PLGA-based nanoparticles for cancer therapy and magnetic resonance imaging. Int J Pharm 2013; 447:94-101. [DOI: 10.1016/j.ijpharm.2013.02.042] [Citation(s) in RCA: 165] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2013] [Revised: 02/15/2013] [Accepted: 02/18/2013] [Indexed: 01/17/2023]
|
14
|
Dadashzadeh ER, Hobson M, Bryant LH, Dean DD, Frank JA. Rapid spectrophotometric technique for quantifying iron in cells labeled with superparamagnetic iron oxide nanoparticles: potential translation to the clinic. CONTRAST MEDIA & MOLECULAR IMAGING 2013; 8:50-6. [PMID: 23109392 PMCID: PMC3490434 DOI: 10.1002/cmmi.1493] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Labeling cells with superparamagnetic iron oxide (SPIO) nanoparticles provides the ability to track cells by magnetic resonance imaging. Quantifying intracellular iron concentration in SPIO labeled cells would allow for the comparison of agents and techniques used to magnetically label cells. Here we describe a rapid spectrophotometric technique (ST) to quantify iron content of SPIO-labeled cells, circumventing the previous requirement of an overnight acid digestion. Following lysis with 10% sodium dodecyl sulfate (SDS) of magnetically labeled cells, quantification of SPIO doped or labeled cells was performed using commonly available spectrophotometric instrument(s) by comparing absorptions at 370 and 750 nm with correction for turbidity of cellular products to determine the iron content of each sample. Standard curves demonstrated high linear correlation (R(2) = 0.998) between absorbance spectra of iron oxide nanoparticles and concentration in known SPIO-doped cells. Comparisons of the ST with inductively coupled plasma-mass spectroscopy (ICP-MS) or nuclear magnetic resonance relaxometric (R(2)) determinations of intracellular iron contents in SPIO containing samples resulted in significant linear correlation between the techniques (R(2) vs ST, R(2) > 0.992, p < 0.0001; ST vs ICP-MS, R(2) > 0.995, p < 0.0001) with the limit of detection of ST for iron = 0.66 µg ml(-1) for 10(6) cells ml(-1). We have developed a rapid straightforward protocol that does not require overnight acid digestion for quantifying iron oxide content in magnetically labeled cells using readily available analytic instrumentation that should greatly expedite advances in comparing SPIO agents and protocols for labeling cells.
Collapse
Affiliation(s)
- Esmaeel R. Dadashzadeh
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
- Howard Hughes Medical Scholar, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Matthew Hobson
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - L. Henry Bryant
- Laboratory of Diagnostic Radiology Research, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Dana D. Dean
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Joseph A. Frank
- Frank Laboratory, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
- Laboratory of Diagnostic Radiology Research, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
- Intramural Research Program, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland 20892
| |
Collapse
|