Danielli F, Berti F, Fanni BM, Gasparotti E, Celi S, Pennati G, Petrini L. Left atrial appendage occlusion: On the need of a numerical model to simulate the implant procedure. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3814. [PMID: 38504482 DOI: 10.1002/cnm.3814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 01/23/2024] [Accepted: 03/10/2024] [Indexed: 03/21/2024]
Abstract
Left atrial appendage occlusion (LAAO) is a percutaneous procedure to prevent thromboembolism in patients affected by atrial fibrillation. Despite its demonstrated efficacy, the LAA morphological complexity hinders the procedure, resulting in postprocedural drawbacks (device-related thrombus and peri-device leakage). Local anatomical features may cause difficulties in the device's positioning and affect the effectiveness of the device's implant. The current work proposes a detailed FE model of the LAAO useful to investigate implant scenarios and derive clinical indications. A high-fidelity model of the Watchman FLX device and simplified parametric conduits mimicking the zone of the LAA where the device is deployed were developed. Device-conduit interactions were evaluated by looking at clinical indicators such as device-wall gap, possible cause of leakage, and device protrusion. As expected, the positioning of the crimped device before the deployment was found to significantly affect the implant outcomes: clinician's choices can be improved if FE models are used to optimize the pre-operative planning. Remarkably, also the wall mechanical stiffness plays an important role. However, this parameter value is unknown for a specific LAA, a crucial point that must be correctly defined for developing an accurate FE model. Finally, numerical simulations outlined how the device's configuration on which the clinician relies to assess the implant success (i.e., the deployed configuration with the device still attached to the catheter) may differ from the actual final device's configuration, relevant for achieving a safe intervention.
Collapse
Affiliation(s)
- Francesca Danielli
- LaBS - Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesca Berti
- LaBS - Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | | | | | - Simona Celi
- BioCardioLab, Fondazione Toscana G. Monasterio, Massa, Italy
| | - Giancarlo Pennati
- LaBS - Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Lorenza Petrini
- Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
2
|
Ramella A, Lissoni V, Bridio S, Rodriguez Matas JF, Trimarchi S, Grossi B, Stefanini GG, Migliavacca F, Luraghi G. On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures. Biomech Model Mechanobiol 2024; 23:525-537. [PMID: 38063955 DOI: 10.1007/s10237-023-01789-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 10/27/2023] [Indexed: 03/26/2024]
Abstract
Transcatheter aortic valve implantation (TAVI) and thoracic endovascular aortic repair (TEVAR) are minimally invasive procedures for treating aortic valves and diseases. Finite element simulations have proven to be valuable tools in predicting device-related complications. In the literature, the inclusion of aortic pre-stress has not been widely investigated. It plays a crucial role in determining the biomechanical response of the vessel and the device-tissue interaction. This study aims at demonstrating how and when to include the aortic pre-stress in patient-specific TAVI and TEVAR simulations. A percutaneous aortic valve and a stent-graft were implanted in aortic models reconstructed from patient-specific CT scans. Two scenarios for each patient were compared, i.e., including and neglecting the wall pre-stress. The neglection of pre-stress underestimates the contact pressure of 48% and 55%, the aorta stresses of 162% and 157%, the aorta strains of 77% and 21% for TAVI and TEVAR models, respectively. The stent stresses are higher than 48% with the pre-stressed aorta in TAVI simulations; while, similar results are obtained in TEVAR cases. The distance between the device and the aorta is similar with and without pre-stress. The inclusion of the aortic wall pre-stress has the capability to give a better representation of the biomechanical behavior of the arterial tissues and the implanted device. It is suggested to include this effect in patient-specific simulations replicating the procedures.
Collapse
Affiliation(s)
- Anna Ramella
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Vittorio Lissoni
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Sara Bridio
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Jose Felix Rodriguez Matas
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Santi Trimarchi
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, Milan, Italy
- Department of Clinical Sciences and Community Health, University of Milan, Via Della Commenda 19, 20122, Milan, Italy
| | - Benedetta Grossi
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Giulio G Stefanini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni 56, 20089, Rozzano, Milan, Italy
| | - Francesco Migliavacca
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Giulia Luraghi
- Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy.
| |
Collapse
|
3
|
Kan X, Ma T, Jiang X, Holzapfel GA, Dong Z, Xu XY. Towards biomechanics-based pre-procedural planning for thoracic endovascular aortic repair of aortic dissection. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107994. [PMID: 38159449 DOI: 10.1016/j.cmpb.2023.107994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/17/2023] [Accepted: 12/21/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND AND OBJECTIVE Although thoracic aortic endovascular repair (TEVAR) has shown promising outcomes in the treatment of patients with complicated type B aortic dissection, complications still occur after TEVAR that can lead to catastrophic events. Biomechanical interactions between the stent-graft (SG) and the local aortic tissue play a critical role in determining the outcome of TEVAR. Different SG design may cause different biomechanical responses in the treated aorta, but such information is not known at the time of pre-procedural planning. By developing patient-specific virtual stent-graft deployment tools, it is possible to analyse and compare the biomechanical impact of different SGs on the local aorta for individual patients. METHODS A finite element based virtual SG deployment model was employed in this study. Computational simulations were performed on a patient-specific model of type B aortic dissection, accounting for details of the SG design and the hyperelastic behaviour of the aortic wall. Based on the geometry reconstructed from the pre-TEVAR CTA scan, the patient-specific aortic dissection model was created and pre-stressed. Parametric models of three different SG products (SG1, SG2 and SG3) were built with two different lengths for each design. The SG models incorporated different stent and graft materials, stent strut patterns, and assembly approaches. Using our validated SG deployment simulation framework, virtual trials were performed on the patient-specific aortic dissection model using different SG products and varying SG lengths. CONCLUSION Simulation results for different SG products suggest that SG3 with a longer length (SG3-long) would be the most appropriate device for the individual patient. Compared to SG1-short (the SG deployed in the patient), SG3-long followed the true lumen tortuosity closely, resulted in a more uniform true lumen expansion and a significant reduction in peak stress in the distal landing zone. These simulation results are promising and demonstrate the feasibility of using the virtual SG deployment model to assist clinicians in pre-procedural planning.
Collapse
Affiliation(s)
- Xiaoxin Kan
- Centre for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China; Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Tao Ma
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; Institute of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xiaolang Jiang
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; Institute of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Norwegian University of Science and Technology (NTNU), Department of Structural Engineering, Trondheim, Norway
| | - Zhihui Dong
- Centre for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China; Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; Institute of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom.
| |
Collapse
|
4
|
Brand M, Yoel B, Eichler E, Speter C, Halak M, Marom G. The effect of stent graft curvature on the hemodynamic displacement force after abdominal aortic aneurysm endovascular repair. ROYAL SOCIETY OPEN SCIENCE 2023; 10:230563. [PMID: 37416831 PMCID: PMC10320339 DOI: 10.1098/rsos.230563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 06/12/2023] [Indexed: 07/08/2023]
Abstract
Endovascular aortic aneurysm repair is a minimally invasive procedure with low mortality and morbidity. Clinical studies have revealed that a displacement force (DF) can cause stent graft (SG) migration in some circumstances requiring repeated intervention. This study aims to determine the relationship between the SG curvature and the calculated DF from four patient-specific computational fluid dynamics models. The SG's curvature was defined according to the centrelines of the implanted SG's branches. The centrelines were defined as either intersecting or separated lines. The centreline curvature (CLC) metrics were calculated based on the local curvature radii and the distances from the centrelines of idealized straight branches. The average CLC value and average variation were calculated to represent the entire graft's curvature. These CLC calculations were compared, and the method that gave the best correlation to the calculated DF was found. The optimal correlation is obtained from calculating the CLC average variation using separated centrelines and distance from straight lines, with an R2 = 0.89. Understanding the relationship between vascular morphology and DF can help identify at-risk patients before the procedure. In these cases, we can provide appropriate treatment and follow up with the patient to prevent future failure.
Collapse
Affiliation(s)
| | | | | | - Chen Speter
- Department of Vascular Surgery, The Chaim Sheba Medical Centre, Tel Hashomer, Israel
| | - Moshe Halak
- Department of Vascular Surgery, The Chaim Sheba Medical Centre, Tel Hashomer, Israel
| | - Gil Marom
- Tel Aviv University, Ramat Aviv, Tel Aviv, Israel
| |
Collapse
|
5
|
Shahbazian N, Doyle MG, Forbes TL, Amon CH. A modeling framework for computational simulations of thoracic endovascular aortic repair. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3578. [PMID: 35107881 DOI: 10.1002/cnm.3578] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 01/29/2022] [Indexed: 05/12/2023]
Abstract
Thoracic endovascular aortic repair (TEVAR) is a minimally invasive treatment for thoracic aortic conditions including aneurysms and is associated with a number of postoperative stent graft related complications. Computational simulations of TEVAR have the potential to predict surgical outcomes and complications preoperatively. When using simulations for stent graft design and prediction of complications in a population, it is difficult to generalize patient-specific TEVAR computational models due to patient variability. This study proposes a novel modeling framework for creating realistic population-based computational models of TEVAR focused on aneurysms that allow for developing various clinically relevant geometric configurations and scenarios that are not easily attainable with limited patient data. The framework includes a methodology for developing population-based thoracic aortic geometries and defining age-dependent aortic tissue material models, as well as detailed steps and boundary conditions for finite element modeling of stent graft deployment during TEVAR. The simulation framework is illustrated for predicting the formation of a bird-beak configuration, a wedge-shaped gap at the proximal end of the deployed stent graft in TEVAR that leads to incomplete seal. A baseline TEVAR simulation model was developed along with three simulations in which the value of aortic curvature, aortic arch angle, or aortic tissue properties varied from the baseline model. Analyzing the length and angle of the bird-beak configuration in each case shows that the bird-beak size is sensitive to different values of the aortic geometry highlighting the importance of using realistic parameter values.
Collapse
Affiliation(s)
- Negin Shahbazian
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Matthew G Doyle
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada
- Department of Surgery, Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network, University of Toronto, Toronto, Ontario, Canada
| | - Thomas L Forbes
- Department of Surgery, Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network, University of Toronto, Toronto, Ontario, Canada
| | - Cristina H Amon
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
6
|
Derycke L, Avril S, Millon A. Patient-Specific Numerical Simulations of Endovascular Procedures in Complex Aortic Pathologies: Review and Clinical Perspectives. J Clin Med 2023; 12:jcm12030766. [PMID: 36769418 PMCID: PMC9917982 DOI: 10.3390/jcm12030766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/13/2023] [Accepted: 01/16/2023] [Indexed: 01/20/2023] Open
Abstract
The endovascular technique is used in the first line treatment in many complex aortic pathologies. Its clinical outcome is mostly determined by the appropriate selection of a stent-graft for a specific patient and the operator's experience. New tools are still needed to assist practitioners with decision making before and during procedures. For this purpose, numerical simulation enables the digital reproduction of an endovascular intervention with various degrees of accuracy. In this review, we introduce the basic principles and discuss the current literature regarding the use of numerical simulation for endovascular management of complex aortic diseases. Further, we give the future direction of everyday clinical applications, showing that numerical simulation is about to revolutionize how we plan and carry out endovascular interventions.
Collapse
Affiliation(s)
- Lucie Derycke
- Department of Cardio-Vascular and Vascular Surgery, Hôpital Européen Georges Pompidou, F-75015 Paris, France
- Centre CIS, Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France
| | - Stephane Avril
- Centre CIS, Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France
| | - Antoine Millon
- Department of Vascular and Endovascular Surgery, Hospices Civils de Lyon, Louis Pradel University Hospital, F-69500 Bron, France
- Correspondence:
| |
Collapse
|
7
|
Avril S, Gee MW, Hemmler A, Rugonyi S. Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3529. [PMID: 34490740 DOI: 10.1002/cnm.3529] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 08/30/2021] [Indexed: 06/13/2023]
Abstract
Endovascular aortic repair (EVAR) has become the preferred intervention option for aortic aneurysms and dissections. This is because EVAR is much less invasive than the alternative open surgery repair. While in-hospital mortality rates are smaller for EVAR than open repair (1%-2% vs. 3%-5%), the early benefits of EVAR are lost after 3 years due to larger rates of complications in the EVAR group. Clinicians follow instructions for use (IFU) when possible, but are left with personal experience on how to best proceed and what choices to make with respect to stent-graft (SG) model choice, sizing, procedural options, and their implications on long-term outcomes. Computational modeling of SG deployment in EVAR and tissue remodeling after intervention offers an alternative way of testing SG designs in silico, in a personalized way before intervention, to ultimately select the strategies leading to better outcomes. Further, computational modeling can be used in the optimal design of SGs in cases of complex geometries. In this review, we address some of the difficulties and successes associated with computational modeling of EVAR procedures. There is still work to be done in all areas of EVAR in silico modeling, including model validation, before models can be applied in the clinic, but much progress has already been made. Critical to clinical implementation are current efforts focusing on developing fast algorithms that can achieve (near) real-time solutions, as well as ways of dealing with inherent uncertainties related to patient aortic wall degradation on an individualized basis. We are optimistic that EVAR modeling in the clinic will soon become a reality to help clinicians optimize EVAR interventions and ultimately reduce EVAR-associated complications.
Collapse
Affiliation(s)
- Stéphane Avril
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, Saint-Étienne, France
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - André Hemmler
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - Sandra Rugonyi
- Biomedical Engineering Department, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
8
|
Kan X, Ma T, Lin J, Wang L, Dong Z, Xu XY. Patient-specific simulation of stent-graft deployment in type B aortic dissection: model development and validation. Biomech Model Mechanobiol 2021; 20:2247-2258. [PMID: 34431034 PMCID: PMC8595232 DOI: 10.1007/s10237-021-01504-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 08/11/2021] [Indexed: 11/29/2022]
Abstract
Thoracic endovascular aortic repair (TEVAR) has been accepted as the mainstream treatment for type B aortic dissection, but post-TEVAR biomechanical-related complications are still a major drawback. Unfortunately, the stent-graft (SG) configuration after implantation and biomechanical interactions between the SG and local aorta are usually unknown prior to a TEVAR procedure. The ability to obtain such information via personalised computational simulation would greatly assist clinicians in pre-surgical planning. In this study, a virtual SG deployment simulation framework was developed for the treatment for a complicated aortic dissection case. It incorporates patient-specific anatomical information based on pre-TEVAR CT angiographic images, details of the SG design and the mechanical properties of the stent wire, graft and dissected aorta. Hyperelastic material parameters for the aortic wall were determined based on uniaxial tensile testing performed on aortic tissue samples taken from type B aortic dissection patients. Pre-stress conditions of the aortic wall and the action of blood pressure were also accounted for. The simulated post-TEVAR configuration was compared with follow-up CT scans, demonstrating good agreement with mean deviations of 5.8% in local open area and 4.6 mm in stent strut position. Deployment of the SG increased the maximum principal stress by 24.30 kPa in the narrowed true lumen but reduced the stress by 31.38 kPa in the entry tear region where there was an aneurysmal expansion. Comparisons of simulation results with different levels of model complexity suggested that pre-stress of the aortic wall and blood pressure inside the SG should be included in order to accurately predict the deformation of the deployed SG.
Collapse
Affiliation(s)
- Xiaoxin Kan
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Tao Ma
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Jing Lin
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, Shanghai, China
| | - Lu Wang
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|
9
|
Hemmler A, Lin A, Thierfelder N, Franz T, Gee MW, Bezuidenhout D. Customized stent-grafts for endovascular aneurysm repair with challenging necks: A numerical proof of concept. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3316. [PMID: 32022404 DOI: 10.1002/cnm.3316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 12/05/2019] [Accepted: 01/23/2020] [Indexed: 06/10/2023]
Abstract
Endovascular aortic repair (EVAR) is a challenging intervention whose long-term success strongly depends on the appropriate stent-graft (SG) selection and sizing. Most off-the-shelf SGs are straight and cylindrical. Especially in challenging vessel morphologies, the morphology of off-the-shelf SGs is not able to meet the patient-specific demands. Advanced manufacturing technologies facilitate the development of highly customized SGs. Customized SGs that have the same morphology as the luminal vessel surface could considerably improve the quality of the EVAR outcome with reduced likelihoods of EVAR related complications such as endoleaks type I and SG migration. In this contribution, we use an in silico EVAR methodology that approximates the deployed state of the elastically deformable SG in a hyperelastic, anisotropic vessel. The in silico EVAR results of off-the-shelf SGs and customized SGs are compared qualitatively and quantitatively in terms of mechanical and geometrical parameters such as stent stresses, contact tractions, SG fixation forces and the SG-vessel attachment. In a numerical proof of concept, eight different vessel morphologies, such as a conical vessel, a barrel shaped vessel and a curved vessel, are used to demonstrate the added value of customized SGs compared to off-the-shelf SGs. The numerical investigation has shown large benefits of the highly customized SGs compared to off-the-shelf SGs with respect to a better SG-vessel attachment and a considerable increase in SG fixation forces of up to 50% which indicate decreased likelihoods of EVAR related complications. Hence, this numerical proof of concept motivates further research and development of highly customized SGs for the use in challenging vessel morphologies.
Collapse
Affiliation(s)
- André Hemmler
- Mechanics & High Performance Computing Group, Technische Universität München, Garching bei München, Germany
| | - Andrew Lin
- Chris Barnard Division of Cardiothoracic Surgery, University of Cape Town, Observatory, South Africa
| | - Nikolaus Thierfelder
- Herzchirurgische Klinik und Poliklinik, Ludwig-Maximilians-Universität München, München, Germany
| | - Thomas Franz
- Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Observatory, South Africa
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Technische Universität München, Garching bei München, Germany
| | - Deon Bezuidenhout
- Chris Barnard Division of Cardiothoracic Surgery, University of Cape Town, Observatory, South Africa
| |
Collapse
|
10
|
Hemmler A, Reeps C, Lutz B, Gee MW. Der digitale Zwilling in der endovaskulären Versorgung. GEFÄSSCHIRURGIE 2019. [DOI: 10.1007/s00772-019-00569-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|