1
|
Sharma S, Buist ML. The origin of intraluminal pressure waves in gastrointestinal tract. Med Biol Eng Comput 2024; 62:3151-3161. [PMID: 38787486 DOI: 10.1007/s11517-024-03128-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 05/10/2024] [Indexed: 05/25/2024]
Abstract
The gastrointestinal (GI) peristalsis is an involuntary wave-like contraction of the GI wall that helps to propagate food along the tract. Many GI diseases, e.g., gastroparesis, are known to cause motility disorders in which the physiological contractile patterns of the wall get disrupted. Therefore, to understand the pathophysiology of these diseases, it is necessary to understand the mechanism of GI motility. We present a coupled electromechanical model to describe the mechanism of GI motility and the transduction pathway of cellular electrical activities into mechanical deformation and the generation of intraluminal pressure (IP) waves in the GI tract. The proposed model consolidates a smooth muscle cell (SMC) model, an actin-myosin interaction model, a hyperelastic constitutive model, and a Windkessel model to construct a coupled model that can describe the origin of peristaltic contractions in the intestine. The key input to the model is external electrical stimuli, which are converted into mechanical contractile waves in the wall. The model recreated experimental observations efficiently and was able to establish a relationship between change in luminal volume and pressure with the compliance of the GI wall and the peripheral resistance to bolus flow. The proposed model will help us understand the GI tract's function in physiological and pathophysiological conditions.
Collapse
Affiliation(s)
- Swati Sharma
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Martin L Buist
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore.
| |
Collapse
|
2
|
Durcan C, Hossain M, Chagnon G, Perić D, Girard E. Mechanical experimentation of the gastrointestinal tract: a systematic review. Biomech Model Mechanobiol 2024; 23:23-59. [PMID: 37935880 PMCID: PMC10901955 DOI: 10.1007/s10237-023-01773-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 09/10/2023] [Indexed: 11/09/2023]
Abstract
The gastrointestinal (GI) organs of the human body are responsible for transporting and extracting nutrients from food and drink, as well as excreting solid waste. Biomechanical experimentation of the GI organs provides insight into the mechanisms involved in their normal physiological functions, as well as understanding of how diseases can cause disruption to these. Additionally, experimental findings form the basis of all finite element (FE) modelling of these organs, which have a wide array of applications within medicine and engineering. This systematic review summarises the experimental studies that are currently in the literature (n = 247) and outlines the areas in which experimentation is lacking, highlighting what is still required in order to more fully understand the mechanical behaviour of the GI organs. These include (i) more human data, allowing for more accurate modelling for applications within medicine, (ii) an increase in time-dependent studies, and (iii) more sophisticated in vivo testing methods which allow for both the layer- and direction-dependent characterisation of the GI organs. The findings of this review can also be used to identify experimental data for the readers' own constitutive or FE modelling as the experimental studies have been grouped in terms of organ (oesophagus, stomach, small intestine, large intestine or rectum), test condition (ex vivo or in vivo), number of directions studied (isotropic or anisotropic), species family (human, porcine, feline etc.), tissue condition (intact wall or layer-dependent) and the type of test performed (biaxial tension, inflation-extension, distension (pressure-diameter), etc.). Furthermore, the studies that investigated the time-dependent (viscoelastic) behaviour of the tissues have been presented.
Collapse
Affiliation(s)
- Ciara Durcan
- Zienkiewicz Centre for Modelling, Data and AI, Faculty of Science and Engineering, Swansea University, Swansea, SA1 8EN, UK
- Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, 38000, Grenoble, France
| | - Mokarram Hossain
- Zienkiewicz Centre for Modelling, Data and AI, Faculty of Science and Engineering, Swansea University, Swansea, SA1 8EN, UK.
| | - Grégory Chagnon
- Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, 38000, Grenoble, France
| | - Djordje Perić
- Zienkiewicz Centre for Modelling, Data and AI, Faculty of Science and Engineering, Swansea University, Swansea, SA1 8EN, UK
| | - Edouard Girard
- Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, 38000, Grenoble, France
- Laboratoire d'Anatomie des Alpes Françaises, Université Grenoble Alpes, Grenoble, France
| |
Collapse
|
3
|
Panda SK, Tan RKY, Tun TA, Buist ML, Nongpiur M, Baskaran M, Aung T, Girard MJA. Changes in Iris Stiffness and Permeability in Primary Angle Closure Glaucoma. Invest Ophthalmol Vis Sci 2021; 62:29. [PMID: 34714323 PMCID: PMC8558521 DOI: 10.1167/iovs.62.13.29] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Purpose To evaluate the biomechanical properties of the iris by evaluating iris movement during pupil constriction and to compare such properties between healthy and primary angle-closure glaucoma (PACG) subjects. Methods A total of 140 subjects were recruited for this study. In a dark room, the anterior segments of one eye per subject were scanned using anterior segment optical coherence tomography imaging during induced pupil constriction with an external white light source of 1700 lux. Using a custom segmentation code, we automatically isolated the iris segments from the AS-OCT images, which were then discretized and transformed into a three-dimensional point cloud. For each iris, a finite element (FE) mesh was constructed from the point cloud, and an inverse FE simulation was performed to match the clinically observed iris constriction in the AS-OCT images. Through this optimization process, we were able to identify the elastic modulus and permeability of each iris. Results For all 140 subjects (95 healthy and 45 PACG of Indian/Chinese ethnicity; age 60.2 ± 8.7 for PACG subjects and 57.7 ± 10.1 for healthy subjects), the simulated deformation pattern of the iris during pupil constriction matched well with OCT images. We found that the iris stiffness was higher in PACG than in healthy controls (24.5 ± 8.4 kPa vs. 17.1 ± 6.6 kPa with 40 kPa of active stress specified in the sphincter region; P < 0.001), whereas iris permeability was lower (0.41 ± 0.2 mm2/kPa s vs. 0.55 ± 0.2 mm2/kPa s; p = 0.142). Conclusions This study suggests that the biomechanical properties of the iris in PACG are different from those in healthy controls. An improved understanding of the biomechanical behavior of the iris may have implications for the understanding and management of angle-closure glaucoma.
Collapse
Affiliation(s)
- Satish K Panda
- Ophthalmic Engineering & Innovation Laboratory (OEIL), Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Department of Biomedical Engineering, National University of Singapore, Singapore
| | - Royston K Y Tan
- Ophthalmic Engineering & Innovation Laboratory (OEIL), Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Department of Biomedical Engineering, National University of Singapore, Singapore
| | - Tin A Tun
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Martin L Buist
- Department of Biomedical Engineering, National University of Singapore, Singapore
| | - Monisha Nongpiur
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Mani Baskaran
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Sankara Nethralaya, Chennai, India
| | - Tin Aung
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Duke-NUS Medical School, Singapore.,Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Michaël J A Girard
- Ophthalmic Engineering & Innovation Laboratory (OEIL), Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Duke-NUS Medical School, Singapore.,Institute of Molecular & Clinical Ophthalmology, Basel, Switzerland
| |
Collapse
|
4
|
Panda SK, Buist ML. A viscoelastic framework for inflation testing of gastrointestinal tissue. J Mech Behav Biomed Mater 2020; 103:103569. [DOI: 10.1016/j.jmbbm.2019.103569] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 11/26/2019] [Accepted: 11/29/2019] [Indexed: 12/01/2022]
|