1
|
El Moçayd N, Belhamadia Y, Seaid M. Unsupervised stochastic learning and reduced order modeling for global sensitivity analysis in cardiac electrophysiology models. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 255:108311. [PMID: 39032242 DOI: 10.1016/j.cmpb.2024.108311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2024] [Revised: 06/25/2024] [Accepted: 06/26/2024] [Indexed: 07/23/2024]
Abstract
BACKGROUND AND OBJECTIVE Numerical simulations in electrocardiology are often affected by various uncertainties inherited from the lack of precise knowledge regarding input values including those related to the cardiac cell model, domain geometry, and boundary or initial conditions used in the mathematical modeling. Conventional techniques for uncertainty quantification in modeling electrical activities of the heart encounter significant challenges, primarily due to the high computational costs associated with fine temporal and spatial scales. Additionally, the need for numerous model evaluations to quantify ubiquitous uncertainties increases the computational challenges even further. METHODS In the present study, we propose a non-intrusive surrogate model to perform uncertainty quantification and global sensitivity analysis in cardiac electrophysiology models. The proposed method combines an unsupervised machine learning technique with the polynomial chaos expansion to reconstruct a surrogate model for the propagation and quantification of uncertainties in the electrical activity of the heart. The proposed methodology not only accurately quantifies uncertainties at a very low computational cost but more importantly, it captures the targeted quantity of interest as either the whole spatial field or the whole temporal period. In order to perform sensitivity analysis, aggregated Sobol indices are estimated directly from the spectral mode of the polynomial chaos expansion. RESULTS We conduct Uncertainty Quantification (UQ) and global Sensitivity Analysis (SA) considering both spatial and temporal variations, rather than limiting the analysis to specific Quantities of Interest (QoIs). To assess the comprehensive performance of our methodology in simulating cardiac electrical activity, we utilize the monodomain model. Additionally, sensitivity analysis is performed on the parameters of the Mitchell-Schaeffer cell model. CONCLUSIONS Unlike conventional techniques for uncertainty quantification in modeling electrical activities, the proposed methodology performs at a low computational cost the sensitivity analysis on the cardiac electrical activity parameters. The results are fully reproducible and easily accessible, while the proposed reduced-order model represents a significant contribution to enhancing global sensitivity analysis in cardiac electrophysiology.
Collapse
Affiliation(s)
- Nabil El Moçayd
- College of Agriculture and Environmental Sciences, University Mohammed VI Polytechnique, Ben Guerir, Morocco.
| | - Youssef Belhamadia
- Department of Mathematics and Statistics, American University of Sharjah, United Arab Emirates.
| | - Mohammed Seaid
- Department of Engineering, University of Durham, South Road, Durham DH1 3LE, United Kingdom.
| |
Collapse
|
2
|
Schäfer F, Schiavazzi DE, Hellevik LR, Sturdy J. Global sensitivity analysis with multifidelity Monte Carlo and polynomial chaos expansion for vascular haemodynamics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3836. [PMID: 38837871 DOI: 10.1002/cnm.3836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/04/2024] [Accepted: 05/12/2024] [Indexed: 06/07/2024]
Abstract
Computational models of the cardiovascular system are increasingly used for the diagnosis, treatment, and prevention of cardiovascular disease. Before being used for translational applications, the predictive abilities of these models need to be thoroughly demonstrated through verification, validation, and uncertainty quantification. When results depend on multiple uncertain inputs, sensitivity analysis is typically the first step required to separate relevant from unimportant inputs, and is key to determine an initial reduction on the problem dimensionality that will significantly affect the cost of all downstream analysis tasks. For computationally expensive models with numerous uncertain inputs, sample-based sensitivity analysis may become impractical due to the substantial number of model evaluations it typically necessitates. To overcome this limitation, we consider recently proposed Multifidelity Monte Carlo estimators for Sobol' sensitivity indices, and demonstrate their applicability to an idealized model of the common carotid artery. Variance reduction is achieved combining a small number of three-dimensional fluid-structure interaction simulations with affordable one- and zero-dimensional reduced-order models. These multifidelity Monte Carlo estimators are compared with traditional Monte Carlo and polynomial chaos expansion estimates. Specifically, we show consistent sensitivity ranks for both bi- (1D/0D) and tri-fidelity (3D/1D/0D) estimators, and superior variance reduction compared to traditional single-fidelity Monte Carlo estimators for the same computational budget. As the computational burden of Monte Carlo estimators for Sobol' indices is significantly affected by the problem dimensionality, polynomial chaos expansion is found to have lower computational cost for idealized models with smooth stochastic response.
Collapse
Affiliation(s)
- Friederike Schäfer
- Division of Biomechanics, Norwegian University of Science and Technology (NTNU), Norway
| | - Daniele E Schiavazzi
- Department of Applied and Computational Mathematics and Statistics, University of Notre Dame, Notre Dame, Indiana, USA
| | - Leif Rune Hellevik
- Division of Biomechanics, Norwegian University of Science and Technology (NTNU), Norway
| | - Jacob Sturdy
- Division of Biomechanics, Norwegian University of Science and Technology (NTNU), Norway
| |
Collapse
|
3
|
Signorelli L, Manzoni A, Sætra MJ. Uncertainty quantification and sensitivity analysis of neuron models with ion concentration dynamics. PLoS One 2024; 19:e0303822. [PMID: 38771746 PMCID: PMC11108148 DOI: 10.1371/journal.pone.0303822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 05/01/2024] [Indexed: 05/23/2024] Open
Abstract
This paper provides a comprehensive and computationally efficient case study for uncertainty quantification (UQ) and global sensitivity analysis (GSA) in a neuron model incorporating ion concentration dynamics. We address how challenges with UQ and GSA in this context can be approached and solved, including challenges related to computational cost, parameters affecting the system's resting state, and the presence of both fast and slow dynamics. Specifically, we analyze the electrodiffusive neuron-extracellular-glia (edNEG) model, which captures electrical potentials, ion concentrations (Na+, K+, Ca2+, and Cl-), and volume changes across six compartments. Our methodology includes a UQ procedure assessing the model's reliability and susceptibility to input uncertainty and a variance-based GSA identifying the most influential input parameters. To mitigate computational costs, we employ surrogate modeling techniques, optimized using efficient numerical integration methods. We propose a strategy for isolating parameters affecting the resting state and analyze the edNEG model dynamics under both physiological and pathological conditions. The influence of uncertain parameters on model outputs, particularly during spiking dynamics, is systematically explored. Rapid dynamics of membrane potentials necessitate a focus on informative spiking features, while slower variations in ion concentrations allow a meaningful study at each time point. Our study offers valuable guidelines for future UQ and GSA investigations on neuron models with ion concentration dynamics, contributing to the broader application of such models in computational neuroscience.
Collapse
Affiliation(s)
- Letizia Signorelli
- Department of Mathematics, Politecnico di Milano, Milano, Italy
- Department of Numerical Analysis and Scientific Computing, Simula Research Laboratory, Oslo, Norway
| | - Andrea Manzoni
- MOX, Department of Mathematics, Politecnico di Milano, Milano, Italy
| | - Marte J. Sætra
- Department of Numerical Analysis and Scientific Computing, Simula Research Laboratory, Oslo, Norway
| |
Collapse
|
4
|
Jennings MW, Nithiarasu P, Pant S. Quantifying the efficacy of voltage protocols in characterising ion channel kinetics: A novel information-theoretic approach. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3815. [PMID: 38544355 DOI: 10.1002/cnm.3815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 02/20/2024] [Accepted: 02/27/2024] [Indexed: 05/15/2024]
Abstract
Voltage-clamp experiments are commonly utilised to characterise cellular ion channel kinetics. In these experiments, cells are stimulated using a known time-varying voltage, referred to as the voltage protocol, and the resulting cellular response, typically in the form of current, is measured. Parameters of models that describe ion channel kinetics are then estimated by solving an inverse problem which aims to minimise the discrepancy between the predicted response of the model and the actual measured cell response. In this paper, a novel framework to evaluate the information content of voltage-clamp protocols in relation to ion channel model parameters is presented. Additional quantitative information metrics that allow for comparisons among various voltage protocols are proposed. These metrics offer a foundation for future optimal design frameworks to devise novel, information-rich protocols. The efficacy of the proposed framework is evidenced through the analysis of seven voltage protocols from the literature. By comparing known numerical results for inverse problems using these protocols with the information-theoretic metrics, the proposed approach is validated. The essential steps of the framework are: (i) generate random samples of the parameters from chosen prior distributions; (ii) run the model to generate model output (current) for all samples; (iii) construct reduced-dimensional representations of the time-varying current output using proper orthogonal decomposition (POD); (iv) estimate information-theoretic metrics such as mutual information, entropy equivalent variance, and conditional mutual information using non-parametric methods; (v) interpret the metrics; for example, a higher mutual information between a parameter and the current output suggests the protocol yields greater information about that parameter, resulting in improved identifiability; and (vi) integrate the information-theoretic metrics into a single quantitative criterion, encapsulating the protocol's efficacy in estimating model parameters.
Collapse
Affiliation(s)
- Matthew W Jennings
- Zienkiewicz Institute for Modelling, Data and AI, Swansea University, Swansea, UK
| | - Perumal Nithiarasu
- Zienkiewicz Institute for Modelling, Data and AI, Swansea University, Swansea, UK
| | - Sanjay Pant
- Zienkiewicz Institute for Modelling, Data and AI, Swansea University, Swansea, UK
| |
Collapse
|
5
|
Regazzoni F, Pagani S, Salvador M, Dede' L, Quarteroni A. Learning the intrinsic dynamics of spatio-temporal processes through Latent Dynamics Networks. Nat Commun 2024; 15:1834. [PMID: 38418469 PMCID: PMC11258335 DOI: 10.1038/s41467-024-45323-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 01/19/2024] [Indexed: 03/01/2024] Open
Abstract
Predicting the evolution of systems with spatio-temporal dynamics in response to external stimuli is essential for scientific progress. Traditional equations-based approaches leverage first principles through the numerical approximation of differential equations, thus demanding extensive computational resources. In contrast, data-driven approaches leverage deep learning algorithms to describe system evolution in low-dimensional spaces. We introduce an architecture, termed Latent Dynamics Network, capable of uncovering low-dimensional intrinsic dynamics in potentially non-Markovian systems. Latent Dynamics Networks automatically discover a low-dimensional manifold while learning the system dynamics, eliminating the need for training an auto-encoder and avoiding operations in the high-dimensional space. They predict the evolution, even in time-extrapolation scenarios, of space-dependent fields without relying on predetermined grids, thus enabling weight-sharing across query-points. Lightweight and easy-to-train, Latent Dynamics Networks demonstrate superior accuracy (normalized error 5 times smaller) in highly-nonlinear problems with significantly fewer trainable parameters (more than 10 times fewer) compared to state-of-the-art methods.
Collapse
Affiliation(s)
| | - Stefano Pagani
- MOX, Department of Mathematics, Politecnico di Milano, Milan, Italy
| | - Matteo Salvador
- MOX, Department of Mathematics, Politecnico di Milano, Milan, Italy
- Institute for Computational and Mathematical Engineering, Stanford University, Stanford, CA, USA
| | - Luca Dede'
- MOX, Department of Mathematics, Politecnico di Milano, Milan, Italy
| | - Alfio Quarteroni
- MOX, Department of Mathematics, Politecnico di Milano, Milan, Italy
- École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
6
|
Salvador M, Marsden AL. Branched Latent Neural Maps. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING 2024; 418:116499. [PMID: 37872974 PMCID: PMC10588816 DOI: 10.1016/j.cma.2023.116499] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
We introduce Branched Latent Neural Maps (BLNMs) to learn finite dimensional input-output maps encoding complex physical processes. A BLNM is defined by a simple and compact feedforward partially-connected neural network that structurally disentangles inputs with different intrinsic roles, such as the time variable from model parameters of a differential equation, while transferring them into a generic field of interest. BLNMs leverage latent outputs to enhance the learned dynamics and break the curse of dimensionality by showing excellent in-distribution generalization properties with small training datasets and short training times on a single processor. Indeed, their in-distribution generalization error remains comparable regardless of the adopted discretization during the testing phase. Moreover, the partial connections, in place of a fully-connected structure, significantly reduce the number of tunable parameters. We show the capabilities of BLNMs in a challenging test case involving biophysically detailed electrophysiology simulations in a biventricular cardiac model of a pediatric patient with hypoplastic left heart syndrome. The model includes a 1D Purkinje network for fast conduction and a 3D heart-torso geometry. Specifically, we trained BLNMs on 150 in silico generated 12-lead electrocardiograms (ECGs) while spanning 7 model parameters, covering cell-scale, organ-level and electrical dyssynchrony. Although the 12-lead ECGs manifest very fast dynamics with sharp gradients, after automatic hyperparameter tuning the optimal BLNM, trained in less than 3 hours on a single CPU, retains just 7 hidden layers and 19 neurons per layer. The resulting mean square error is on the order of 10 - 4 on an independent test dataset comprised of 50 additional electrophysiology simulations. In the online phase, the BLNM allows for 5000x faster real-time simulations of cardiac electrophysiology on a single core standard computer and can be employed to solve inverse problems via global optimization in a few seconds of computational time. This paper provides a novel computational tool to build reliable and efficient reduced-order models for digital twinning in engineering applications. The Julia implementation is publicly available under MIT License at https://github.com/StanfordCBCL/BLNM.jl.
Collapse
Affiliation(s)
- Matteo Salvador
- Institute for Computational and Mathematical Engineering, Stanford University, California, USA
- Cardiovascular Institute, Stanford University, California, USA
- Pediatric Cardiology, Stanford University, California, USA
| | - Alison Lesley Marsden
- Department of Bioengineering, Stanford University, California, USA
- Institute for Computational and Mathematical Engineering, Stanford University, California, USA
- Cardiovascular Institute, Stanford University, California, USA
- Pediatric Cardiology, Stanford University, California, USA
| |
Collapse
|
7
|
Hohendanner F, Bock M, Keznickl-Pulst J, Furundzija V, Scholz S, Schöppenthau D, Hrytsyna Y, Falk V, Pieske B, Hindricks G, Potapov E, Gerds-Li JH. Mechanistic assessment and ablation of left ventricular assist device related ventricular tachycardia in patients with severe heart failure. Front Physiol 2023; 14:1086730. [PMID: 37123254 PMCID: PMC10130641 DOI: 10.3389/fphys.2023.1086730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 03/27/2023] [Indexed: 05/02/2023] Open
Abstract
Aims: Left-ventricular-assist-devices (lvad) are an established treatment for patients with severe heart failure with reduced ejection fraction (HF) and reduce mortality. However, HF patients have significant substrate for ventricular tachycardia (VT) and the lvad itself might be pro-arrhythmogenic. We investigated the mechanism of VT in lvad-patients in relation to the underlying etiology and provide in silico and ex-vivo data for ablation in these HF patients. Methods and Results: We retrospectively analyzed invasive electrophysiological (EP) studies of 17 patients with VT and lvad. The mechanism of VT was determined using electroanatomical, entrainment and activation time mapping. Ischemic cardiomyopathy was present in 70% of patients. VT originated from the lvad region in >30%. 1/6 patients with VT originating from the lvad region had episodes before lvad implantation, while 7/11 patients with VT originating from other regions had episodes before implantation. Number and time of radiofrequency (RF)-ablation lesions were not different between VTs originating from the lvad or other regions. Long-term freedom from VT was 50% upon ablation in patients with VT originating from the lvad region and 64% if ablation was conducted in other regions. To potentially preemptively mitigate lvad related VT in patients undergoing lvad implantation, we obtained in silico derived data and performed ex-vivo experiments targeting ventricular myocardium. Of the tested settings, application of 25 W for 30 s was safe and associated with optimal lesion characteristics. Conclusion: A significant percentage of patients with lvad undergoing VT ablation exhibit arrhythmia originating in close vicinity to the device and recurrence rates are high. Based on in silico and ex-vivo data, we propose individualized RF-ablation in selected patients at risk for/with lvad related VT.
Collapse
Affiliation(s)
- Felix Hohendanner
- Deutsches Herzzentrum der Charité, Klinik für Kardiologie, Angiologie und Intensivmedizin, Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
- *Correspondence: Felix Hohendanner,
| | - Matthias Bock
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | | | - Vesna Furundzija
- Deutsches Herzzentrum der Charité, Klinik für Kardiologie, Angiologie und Intensivmedizin, Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Sebastian Scholz
- Department of Cardiology, German Heart Center Berlin, Berlin, Germany
| | - Doreen Schöppenthau
- Deutsches Herzzentrum der Charité, Klinik für Kardiologie, Angiologie und Intensivmedizin, Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Yuriy Hrytsyna
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Deutsches Herzzentrum der Charité, Klinik für Herz, Thorax- und Gefäßchirurgie, Berlin, Germany
| | - Volkmar Falk
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
- Deutsches Herzzentrum der Charité, Klinik für Herz, Thorax- und Gefäßchirurgie, Berlin, Germany
- Translational Cardiovascular Technologies, Institute of Translational Medicine, Department of Health Sciences and Technology, Swiss Federal Institute of Technology (ETH) Zurich, Berlin, Germany
| | - Burkert Pieske
- Department of Cardiology, German Heart Center Berlin, Berlin, Germany
| | - Gerhard Hindricks
- Deutsches Herzzentrum der Charité, Klinik für Kardiologie, Angiologie und Intensivmedizin, Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Evgenij Potapov
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany
| | - Jin-Hong Gerds-Li
- Deutsches Herzzentrum der Charité, Klinik für Kardiologie, Angiologie und Intensivmedizin, Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
8
|
Lazarus A, Dalton D, Husmeier D, Gao H. Sensitivity analysis and inverse uncertainty quantification for the left ventricular passive mechanics. Biomech Model Mechanobiol 2022; 21:953-982. [PMID: 35377030 PMCID: PMC9132878 DOI: 10.1007/s10237-022-01571-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 02/28/2022] [Indexed: 01/08/2023]
Abstract
Personalized computational cardiac models are considered to be a unique and powerful tool in modern cardiology, integrating the knowledge of physiology, pathology and fundamental laws of mechanics in one framework. They have the potential to improve risk prediction in cardiac patients and assist in the development of new treatments. However, in order to use these models for clinical decision support, it is important that both the impact of model parameter perturbations on the predicted quantities of interest as well as the uncertainty of parameter estimation are properly quantified, where the first task is a priori in nature (meaning independent of any specific clinical data), while the second task is carried out a posteriori (meaning after specific clinical data have been obtained). The present study addresses these challenges for a widely used constitutive law of passive myocardium (the Holzapfel-Ogden model), using global sensitivity analysis (SA) to address the first challenge, and inverse-uncertainty quantification (I-UQ) for the second challenge. The SA is carried out on a range of different input parameters to a left ventricle (LV) model, making use of computationally efficient Gaussian process (GP) surrogate models in place of the numerical forward simulator. The results of the SA are then used to inform a low-order reparametrization of the constitutive law for passive myocardium under consideration. The quality of this parameterization in the context of an inverse problem having observed noisy experimental data is then quantified with an I-UQ study, which again makes use of GP surrogate models. The I-UQ is carried out in a Bayesian manner using Markov Chain Monte Carlo, which allows for full uncertainty quantification of the material parameter estimates. Our study reveals insights into the relation between SA and I-UQ, elucidates the dependence of parameter sensitivity and estimation uncertainty on external factors, like LV cavity pressure, and sheds new light on cardio-mechanic model formulation, with particular focus on the Holzapfel-Ogden myocardial model.
Collapse
Affiliation(s)
- Alan Lazarus
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| | - David Dalton
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| | - Dirk Husmeier
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| | - Hao Gao
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| |
Collapse
|
9
|
Woodworth LA, Cansız B, Kaliske M. Balancing conduction velocity error in cardiac electrophysiology using a modified quadrature approach. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3589. [PMID: 35266643 DOI: 10.1002/cnm.3589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 01/20/2022] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
Conduction velocity error is often the main culprit behind the need for very fine spatial discretizations and high computational effort in cardiac electrophysiology problems. In light of this, a novel approach for simulating an accurate conduction velocity in coarse meshes with linear elements is suggested based on a modified quadrature approach. In this approach, the quadrature points are placed at arbitrary offsets of the isoparametric coordinates. A numerical study illustrates the dependence of the conduction velocity on the spatial discretization and the conductivity when using different quadrature rules and calculation approaches. Additionally, examples using the modified quadrature in coarse meshes for wave propagation demonstrate the improved accuracy of the conduction velocity with this method. This novel approach possesses great potential in reducing the computational effort required but remains limited to specific linear elements and experiences a reduction in accuracy for irregular meshes and heterogeneous conductivities. Further research can focus on developing an adaptive quadrature and extending the approach to other element formulations in order to make the approach more generally applicable.
Collapse
Affiliation(s)
- Lucas A Woodworth
- Institute for Structural Analysis, Technische Universität Dresden, Dresden, Germany
| | - Barış Cansız
- Institute for Structural Analysis, Technische Universität Dresden, Dresden, Germany
| | - Michael Kaliske
- Institute for Structural Analysis, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
10
|
Gander L, Pezzuto S, Gharaviri A, Krause R, Perdikaris P, Sahli Costabal F. Fast Characterization of Inducible Regions of Atrial Fibrillation Models With Multi-Fidelity Gaussian Process Classification. Front Physiol 2022; 13:757159. [PMID: 35330935 PMCID: PMC8940533 DOI: 10.3389/fphys.2022.757159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 01/31/2022] [Indexed: 11/13/2022] Open
Abstract
Computational models of atrial fibrillation have successfully been used to predict optimal ablation sites. A critical step to assess the effect of an ablation pattern is to pace the model from different, potentially random, locations to determine whether arrhythmias can be induced in the atria. In this work, we propose to use multi-fidelity Gaussian process classification on Riemannian manifolds to efficiently determine the regions in the atria where arrhythmias are inducible. We build a probabilistic classifier that operates directly on the atrial surface. We take advantage of lower resolution models to explore the atrial surface and combine seamlessly with high-resolution models to identify regions of inducibility. We test our methodology in 9 different cases, with different levels of fibrosis and ablation treatments, totalling 1,800 high resolution and 900 low resolution simulations of atrial fibrillation. When trained with 40 samples, our multi-fidelity classifier that combines low and high resolution models, shows a balanced accuracy that is, on average, 5.7% higher than a nearest neighbor classifier. We hope that this new technique will allow faster and more precise clinical applications of computational models for atrial fibrillation. All data and code accompanying this manuscript will be made publicly available at: https://github.com/fsahli/AtrialMFclass.
Collapse
Affiliation(s)
- Lia Gander
- Center for Computational Medicine in Cardiology, Euler Institute, Università della Svizzera italiana, Lugano, Switzerland
| | - Simone Pezzuto
- Center for Computational Medicine in Cardiology, Euler Institute, Università della Svizzera italiana, Lugano, Switzerland
| | - Ali Gharaviri
- Center for Computational Medicine in Cardiology, Euler Institute, Università della Svizzera italiana, Lugano, Switzerland
| | - Rolf Krause
- Center for Computational Medicine in Cardiology, Euler Institute, Università della Svizzera italiana, Lugano, Switzerland
| | - Paris Perdikaris
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, United States
| | - Francisco Sahli Costabal
- Department of Mechanical and Metallurgical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.,Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile.,Millennium Nucleus for Cardiovascular Magnetic Resonance, Santiago, Chile
| |
Collapse
|
11
|
Regazzoni F, Quarteroni A. Accelerating the convergence to a limit cycle in 3D cardiac electromechanical simulations through a data-driven 0D emulator. Comput Biol Med 2021; 135:104641. [PMID: 34298436 DOI: 10.1016/j.compbiomed.2021.104641] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 07/06/2021] [Accepted: 07/06/2021] [Indexed: 01/19/2023]
Abstract
The results of numerical simulations of cardiac electromechanics are typically characterized by a long transient before reaching a periodic solution known as limit cycle. This yields a serious computational overhead, as the only clinically relevant output is associated with such limit cycle. To accelerate the convergence to the limit cycle, we propose a strategy based on a surrogate model, wherein the computationally demanding 3D components are replaced by a 0D emulator, built through an automated data-driven algorithm on the basis of pressure-volume transients of as few as three heartbeats simulated with the 3D model. The 0D emulator, consisting of a time-dependent pressure-volume relationship, can provide the 3D model with an initial guess, such that in just two heartbeats a solution is reached that is as close to the limit cycle as the one obtained after more than 20 heartbeats with the 3D model. The 0D emulator is also recommended in many-query settings (e.g. when performing sensitivity analysis, parameter estimation and uncertainty quantification), that call for the repeated solution of the model for different values of the parameters. Indeed, the construction of the emulator does not have to be repeated when the parameters of the circulation model it is coupled with vary. Finally, should the parameters of the 3D electromechanical model vary as well, we propose a parametric emulator, obtained by interpolation of emulators constructed for given values of the parameters. This paper is accompanied by a Python library implementing the proposed algorithm, open to integration with existing cardiac solvers.
Collapse
Affiliation(s)
- F Regazzoni
- MOX - Dipartimento di Matematica, Politecnico di Milano, P.zza Leonardo da Vinci 32, 20133, Milano, Italy.
| | - A Quarteroni
- MOX - Dipartimento di Matematica, Politecnico di Milano, P.zza Leonardo da Vinci 32, 20133, Milano, Italy; Mathematics Institute, École Polytechnique Fédérale de Lausanne, Av. Piccard, CH-1015, Lausanne, Switzerland (Professor Emeritus)
| |
Collapse
|